1.
J Med Imaging (Bellingham) ; 9(Suppl 1): 012205, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35309720

RESUMEN

Purpose: For 50 years now, SPIE Medical Imaging (MI) conferences have been the premier forum for disseminating and sharing new ideas, technologies, and concepts on the physics of MI. Approach: Our overarching objective is to demonstrate and highlight the major trajectories of imaging physics and how they are informed by the community and science present and presented at SPIE MI conferences from its inception to now. Results: These contributions range from the development of image science, image quality metrology, and image reconstruction to digital x-ray detectors that have revolutionized MI modalities including radiography, mammography, fluoroscopy, tomosynthesis, and computed tomography (CT). Recent advances in detector technology such as photon-counting detectors continue to enable new capabilities in MI. Conclusion: As we celebrate the past 50 years, we are also excited about what the next 50 years of SPIE MI will bring to the physics of MI.

2.
Radiology ; 282(1): 236-250, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27439324

RESUMEN

Purpose To conduct a multi-institutional, multireader study to compare the performance of digital tomosynthesis, dual-energy (DE) imaging, and conventional chest radiography for pulmonary nodule detection and management. Materials and Methods In this binational, institutional review board-approved, HIPAA-compliant prospective study, 158 subjects (43 subjects with normal findings) were enrolled at four institutions. Informed consent was obtained prior to enrollment. Subjects underwent chest computed tomography (CT) and imaging with conventional chest radiography (posteroanterior and lateral), DE imaging, and tomosynthesis with a flat-panel imaging device. Three experienced thoracic radiologists identified true locations of nodules (n = 516, 3-20-mm diameters) with CT and recommended case management by using Fleischner Society guidelines. Five other radiologists marked nodules and indicated case management by using images from conventional chest radiography, conventional chest radiography plus DE imaging, tomosynthesis, and tomosynthesis plus DE imaging. Sensitivity, specificity, and overall accuracy were measured by using the free-response receiver operating characteristic method and the receiver operating characteristic method for nodule detection and case management, respectively. Results were further analyzed according to nodule diameter categories (3-4 mm, >4 mm to 6 mm, >6 mm to 8 mm, and >8 mm to 20 mm). Results Maximum lesion localization fraction was higher for tomosynthesis than for conventional chest radiography in all nodule size categories (3.55-fold for all nodules, P < .001; 95% confidence interval [CI]: 2.96, 4.15). Case-level sensitivity was higher with tomosynthesis than with conventional chest radiography for all nodules (1.49-fold, P < .001; 95% CI: 1.25, 1.73). Case management decisions showed better overall accuracy with tomosynthesis than with conventional chest radiography, as given by the area under the receiver operating characteristic curve (1.23-fold, P < .001; 95% CI: 1.15, 1.32). There were no differences in any specificity measures. DE imaging did not significantly affect nodule detection when paired with either conventional chest radiography or tomosynthesis. Conclusion Tomosynthesis outperformed conventional chest radiography for lung nodule detection and determination of case management; DE imaging did not show significant differences over conventional chest radiography or tomosynthesis alone. These findings indicate performance likely achievable with a range of reader expertise. © RSNA, 2016 Online supplemental material is available for this article.


Asunto(s)
Nódulos Pulmonares Múltiples/diagnóstico por imagen , Nódulos Pulmonares Múltiples/terapia , Intensificación de Imagen Radiográfica/métodos , Imagen Radiográfica por Emisión de Doble Fotón , Radiografía Torácica , Adulto , Anciano , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad , Suecia , Tomografía Computarizada por Rayos X , Estados Unidos , Pantallas Intensificadoras de Rayos X
3.
Radiographics ; 36(3): 735-50, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27163590

RESUMEN

With flat-panel detector mammography, radiography, and fluoroscopy systems, digital tomosynthesis (DT) has been recently introduced as an advanced clinical application that removes overlying structures, enhances local tissue separation, and provides depth information about structures of interest by providing high-quality tomographic images. DT images are generated from projection image data, typically using filtered back-projection or iterative reconstruction. These low-dose x-ray projection images are easily and swiftly acquired over a range of angles during a single linear or arc sweep of the x-ray tube assembly. DT is advantageous in a variety of clinical contexts, including breast, chest, head and neck, orthopedic, emergency, and abdominal imaging. Specifically, compared with conventional mammography, radiography, and fluoroscopy, as a result of reduced tissue overlap DT can improve detection of breast cancer, pulmonary nodules, sinonasal mucosal thickening, and bone fractures and delineation of complex anatomic structures such as the ostiomeatal unit, atlantoaxial joint, carpal and tarsal bones, and pancreatobiliary and gastrointestinal tracts. Compared with computed tomography, DT offers reduced radiation exposure, better in-plane resolution to improve assessment of fine bony changes, and less metallic artifact, improving postoperative evaluation of patients with metallic prostheses and osteosynthesis materials. With more flexible patient positioning, DT is also useful for functional, weight-bearing, and stress tests. To optimize patient management, a comprehensive understanding of the clinical applications and limitations of whole-body DT applications is important for improvement of diagnostic quality, workflow, and cost-effectiveness. Online supplemental material is available for this article. (©)RSNA, 2016.


Asunto(s)
Intensificación de Imagen Radiográfica/métodos , Imagen de Cuerpo Entero , Humanos , Dosis de Radiación , Pantallas Intensificadoras de Rayos X
4.
Med Phys ; 41(9): 091501, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25186375

RESUMEN

The radiation dose involved in any medical imaging modality that uses ionizing radiation needs to be well understood by the medical physics and clinical community. This is especially true of screening modalities. Digital breast tomosynthesis (DBT) has recently been introduced into the clinic and is being used for screening for breast cancer in the general population. Therefore, it is important that the medical physics community have the required information to be able to understand, estimate, and communicate the radiation dose levels involved in breast tomosynthesis imaging. For this purpose, the American Association of Physicists in Medicine Task Group 223 on Dosimetry in Tomosynthesis Imaging has prepared this report that discusses dosimetry in breast imaging in general, and describes a methodology and provides the data necessary to estimate mean breast glandular dose from a tomosynthesis acquisition. In an effort to maximize familiarity with the procedures and data provided in this Report, the methodology to perform the dose estimation in DBT is based as much as possible on that used in mammography dose estimation.


Asunto(s)
Mamografía/métodos , Intensificación de Imagen Radiográfica/métodos , Radiometría/métodos , Algoritmos , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/diagnóstico por imagen , Simulación por Computador , Humanos , Mamografía/instrumentación , Modelos Biológicos , Método de Montecarlo , Intensificación de Imagen Radiográfica/instrumentación , Sociedades Médicas , Estados Unidos
5.
Jpn J Radiol ; 31(7): 465-70, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23744489

RESUMEN

PURPOSE: To investigate the feasibility of dual-energy subtraction (DES) in patients with moderate-severe cervical spondylosis for improving delineation of the larynx on flat panel detector (FPD) radiography. MATERIALS AND METHODS: For 118 patients, we graded conventional/DES anterior-posterior views for delineation of the vocal cords, subglottis, and pyriform sinus using a 5-point scale and lateral views from conventional laryngeal FPD radiography to determine cervical spondylosis severity on a scale from 0 (none) to 3 (severe). We compared the delineation of each anatomical structure in both groups of grades 0-1 and grades 2-3 of spondylosis severity between conventional and DES methods and the improved delineation rate for each anatomical structure by DES compared to the conventional method between both groups. RESULTS: With DES, the delineation of each anatomical structure was significantly better than with conventional radiography for both groups (P < 0.0001). The improved delineation rate of the vocal cord and subglottis using DES was significantly higher in grades 2-3 than in grades 0-1 (P < 0.05), although there was no significant difference in the delineation rate of the pyriform sinus between the groups (P = 0.847). CONCLUSION: DES provides better delineation of the laryngeal anatomy than conventional FPD radiography predominantly in patients with moderate-severe cervical spondylosis.


Asunto(s)
Laringe/diagnóstico por imagen , Espondilosis/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radiografía , Estudios Retrospectivos , Técnica de Sustracción , Pantallas Intensificadoras de Rayos X
6.
J Comput Assist Tomogr ; 37(2): 252-6, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23493215

RESUMEN

OBJECTIVE: We investigated the diagnostic accuracy of digital tomosynthesis (DT) radiography for detecting sinus opacification. METHODS: For 31 adult patients with signs suggestive of sinusitis who underwent both sinus multi-detector-row computed tomography and DT, 2 readers independently assessed opacification in the maxillary, ethmoid, frontal, and sphenoid sinuses by DT and in consensus determined the presence of opacification in each sinus by multi-detector-row computed tomography as a reference. We assessed the diagnostic accuracy of DT and interreader agreement with DT using Cohen κ statistics. RESULTS: For the maxillary, ethmoid, frontal, and sphenoid sinuses, opacification was identified in 81.7%, 75.9%, 59.3%, and 40.7%; the sensitivity/specificity for detecting opacification by DT were 93.9/72.7%, 79.5/71.4%, 93.8/72.7%, and 90.9/75.0% for reader 1 and 95.9/100.0%, 95.5/92.9%, 100.0/81.8%, and 81.8/75.0% for reader 2; the interreader agreement was 0.79, 0.42, 0.67, and 0.63, respectively. CONCLUSIONS: Digital tomosynthesis allows relatively accurate detection of sinus opacification with substantial interreader agreement for all the sinuses except the ethmoid sinuses.


Asunto(s)
Senos Paranasales/diagnóstico por imagen , Sinusitis/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estudios Retrospectivos , Sensibilidad y Especificidad
7.
Eur J Radiol ; 81(6): 1140-5, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21515010

RESUMEN

OBJECTIVE: Using an anthropomorphic phantom, we have investigated the feasibility of digital tomosynthesis (DT) of flat-panel detector (FPD) radiography to reduce radiation dose for sinonasal examination compared to multi-detector computed tomography (MDCT). MATERIALS AND METHODS: A female Rando phantom was scanned covering frontal to maxillary sinus using the clinically routine protocol by both 64-detector CT (120 kV, 200 mAs, and 1.375-pitch) and DT radiography (80 kV, 1.0 mAs per projection, 60 projections, 40° sweep, and posterior-anterior projections). Glass dosimeters were used to measure the radiation dose to internal organs including the thyroid gland, brain, submandibular gland, and the surface dose at various sites including the eyes during those scans. We compared the radiation dose to those anatomies between both modalities. RESULTS: In DT radiography, the doses of the thyroid gland, brain, submandibular gland, skin, and eyes were 230 ± 90 µGy, 1770 ± 560 µGy, 1400 ± 80 µGy, 1160 ± 2100 µGy, and 112 ± 6 µGy, respectively. These doses were reduced to approximately 1/5, 1/8, 1/12, 1/17, and 1/290 of the respective MDCT dose. CONCLUSION: For sinonasal examinations, DT radiography enables dramatic reduction in radiation exposure and dose to the head and neck region, particularly to the lens of the eye.


Asunto(s)
Senos Paranasales/diagnóstico por imagen , Dosis de Radiación , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada Espiral/métodos , Estudios de Factibilidad , Humanos , Fantasmas de Imagen
8.
Med Phys ; 38(12): 6672-82, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22149849

RESUMEN

PURPOSE: Digital x-ray tomosynthesis (DTS) has the potential to provide 3D information about the knee joint in a load-bearing posture, which may improve diagnosis and monitoring of knee osteoarthritis compared with projection radiography, the current standard of care. Manually quantifying and visualizing the joint space width (JSW) from 3D tomosynthesis datasets may be challenging. This work developed a semiautomated algorithm for quantifying the 3D tibiofemoral JSW from reconstructed DTS images. The algorithm was validated through anthropomorphic phantom experiments and applied to three clinical datasets. METHODS: A user-selected volume of interest within the reconstructed DTS volume was enhanced with 1D multiscale gradient kernels. The edge-enhanced volumes were divided by polarity into tibial and femoral edge maps and combined across kernel scales. A 2D connected components algorithm was performed to determine candidate tibial and femoral edges. A 2D joint space width map (JSW) was constructed to represent the 3D tibiofemoral joint space. To quantify the algorithm accuracy, an adjustable knee phantom was constructed, and eleven posterior-anterior (PA) and lateral DTS scans were acquired with the medial minimum JSW of the phantom set to 0-5 mm in 0.5 mm increments (VolumeRad™, GE Healthcare, Chalfont St. Giles, United Kingdom). The accuracy of the algorithm was quantified by comparing the minimum JSW in a region of interest in the medial compartment of the JSW map to the measured phantom setting for each trial. In addition, the algorithm was applied to DTS scans of a static knee phantom and the JSW map compared to values estimated from a manually segmented computed tomography (CT) dataset. The algorithm was also applied to three clinical DTS datasets of osteoarthritic patients. RESULTS: The algorithm segmented the JSW and generated a JSW map for all phantom and clinical datasets. For the adjustable phantom, the estimated minimum JSW values were plotted against the measured values for all trials. A linear fit estimated a slope of 0.887 (R² = 0.962) and a mean error across all trials of 0.34 mm for the PA phantom data. The estimated minimum JSW values for the lateral adjustable phantom acquisitions were found to have low correlation to the measured values (R² = 0.377), with a mean error of 2.13 mm. The error in the lateral adjustable-phantom datasets appeared to be caused by artifacts due to unrealistic features in the phantom bones. JSW maps generated by DTS and CT varied by a mean of 0.6 mm and 0.8 mm across the knee joint, for PA and lateral scans. The tibial and femoral edges were successfully segmented and JSW maps determined for PA and lateral clinical DTS datasets. CONCLUSIONS: A semiautomated method is presented for quantifying the 3D joint space in a 2D JSW map using tomosynthesis images. The proposed algorithm quantified the JSW across the knee joint to sub-millimeter accuracy for PA tomosynthesis acquisitions. Overall, the results suggest that x-ray tomosynthesis may be beneficial for diagnosing and monitoring disease progression or treatment of osteoarthritis by providing quantitative images of JSW in the load-bearing knee.


Asunto(s)
Algoritmos , Imagenología Tridimensional/métodos , Articulación de la Rodilla/diagnóstico por imagen , Reconocimiento de Normas Patrones Automatizadas/métodos , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Fémur/diagnóstico por imagen , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tibia/diagnóstico por imagen
9.
Jpn J Radiol ; 29(8): 583-6, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21928001

RESUMEN

Digital tomosynthesis with flat-panel detector radiography is a novel application that allows easy, swift volume data acquisition of any anatomical site of interest with arbitrary patient posture. A single sweep of the X-ray tube provides multiple tomographic images of high resolution. We present the first patient with olecranon fracture who underwent internal fixation and 1-year postoperative follow-up with tomosynthesis. The minimal metallic artifact by this modality successfully provided detailed information regarding the healing process of the fracture.


Asunto(s)
Fijación Interna de Fracturas/métodos , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía , Olécranon/diagnóstico por imagen , Olécranon/lesiones , Olécranon/cirugía , Intensificación de Imagen Radiográfica/instrumentación , Pantallas Intensificadoras de Rayos X , Accidentes por Caídas , Hilos Ortopédicos , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X
10.
Korean J Radiol ; 11(3): 320-6, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20461186

RESUMEN

OBJECTIVE: To investigate the clinical feasibility of dual energy subtraction (DES) imaging to improve the delineation of the vocal cord and diagnostic accuracy of vocal cord paralysis as compared with the anterior-posterior view of flat panel detector (FPD) neck radiography. MATERIALS AND METHODS: For 122 consecutive patients who underwent both a flexible laryngoscopy and conventional/DES FPD radiography, three blinded readers retrospectively graded the radiographs during phonation and inspiration on a scale of 1 (poor) to 5 (excellent) for the delineation of the vocal cord, and in consensus, reviewed the diagnostic accuracy of vocal cord paralysis employing the laryngoscopy as the reference. We compared vocal cord delineation scores and accuracy of vocal cord paralysis diagnosis by both conventional and DES techniques using kappa statistics and assessing the area under the receiver operating characteristic curve (AUC). RESULTS: Vocal cord delineation scores by DES (mean, 4.2 +/- 0.4) were significantly higher than those by conventional imaging (mean, 3.3 +/- 0.5) (p < 0.0001). Sensitivity for diagnosing vocal cord paralysis by the conventional technique was 25%, whereas the specificity was 94%. Sensitivity by DES was 75%, whereas the specificity was 96%. The diagnostic accuracy by DES was significantly superior (kappa = 0.60, AUC = 0.909) to that by conventional technique (kappa = 0.18, AUC = 0.852) (p = 0.038). CONCLUSION: Dual energy subtraction is a superior method compared to the conventional FPD radiography for delineating the vocal cord and accurately diagnosing vocal cord paralysis.


Asunto(s)
Absorciometría de Fotón/instrumentación , Absorciometría de Fotón/métodos , Parálisis de los Pliegues Vocales/diagnóstico por imagen , Pantallas Intensificadoras de Rayos X , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Técnica de Sustracción , Pliegues Vocales/diagnóstico por imagen , Adulto Joven
11.
Radiographics ; 30(2): 549-62, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20228334

RESUMEN

Digital tomosynthesis is a novel technique that allows easy and swift volume data acquisition in selected regions of the body. However, many radiologists and technologists are unfamiliar with this technique and the potential artifacts related to data acquisition. Digital tomosynthesis requires a single linear sweep of the x-ray tube assembly with corresponding tomographic reconstruction of large-area flat-panel detector radiographic data. Standard acquisition parameters include sweep angle, sweep direction, patient barrier-object distance, number of projections, and total radiation dose. Potential acquisition-related artifacts include blurring-ripple, ghost artifact-distortion, poor spatial resolution, image noise, and metallic artifact. A comprehensive understanding of the relationships between acquisition parameters and potential associated artifacts is critical to optimizing acquisition technique and avoiding misinterpretation of artifacts. Sweep direction should be chosen on the basis of the anatomy of interest and the purpose of the examination so as to reduce the influence of blurring-ripple, ghost artifact-distortion, and metallic artifact. Adjusting the sweep angle, number of projections, and radiation dose will optimize depth resolution, avoid ripple in the sections of interest, and reduce unnecessary radiation exposure without compromising image quality. Thus, it is important that the radiologist and technologist establish appropriate protocols for different examination types to allow optimal utilization of this novel imaging technique.


Asunto(s)
Intensificación de Imagen Radiográfica/instrumentación , Intensificación de Imagen Radiográfica/métodos , Pantallas Intensificadoras de Rayos X , Diseño de Equipo , Humanos
12.
Med Phys ; 36(12): 5480-7, 2009 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-20095260

RESUMEN

PURPOSE: The recent introduction of digital tomosynthesis imaging into routine clinical use has enabled the acquisition of volumetric patient data within a standard radiographic examination. Tomosynthesis requires the acquisition of multiple projection views, requiring additional dose compared to a standard projection examination. Knowledge of the effective dose is needed to make an appropriate decision between standard projection, tomosynthesis, and CT for thoracic x-ray examinations. In this article, the effective dose to the patient of chest tomosynthesis is calculated and compared to a standard radiographic examination and to values published for thoracic CT. METHODS: Radiographic technique data for posterior-anterior (PA) and left lateral (LAT) radiographic chest examinations of medium-sized adults was obtained from clinical sites. From these data, the average incident air kerma for the standard views was determined. A commercially available tomosynthesis system was used to define the acquisition technique and geometry for each projection view. Using Monte Carlo techniques, the effective dose of the PA, LAT, and each tomosynthesis projection view was calculated. The effective dose for all projections of the tomosynthesis sweep was summed and compared to the calculated PA and LAT values and to the published values for thoracic CT. RESULTS: The average incident air kerma for the PA and left lateral clinical radiographic examinations were found to be 0.10 and 0.40 mGy, respectively. The effective dose for the PA view of a patient of the size of an average adult male was determined to be 0.017 mSv (ICRP 60) [0.018 mSv (ICRP 103)]. For the left lateral view of the same sized patient, the effective dose was determined to be 0.039 mSv (ICRP 60) [0.050 mSv (ICRP 103)]. The cumulative mA s for a tomosynthesis examination is recommended to be ten times the mA s of the PA image. With this technique, the effective dose for an average tomosynthesis examination was calculated to be 0.124 mSv (ICRP60) [0.134 mSv (ICRP103)]. This is less than 75% of that predicted by scaling of the PA mA s ratio. This lower dose was due to changes in the focal-spot-to-skin distance, effective changes in collimation with projection angle, rounding down of the mA s step, and variations in organ exposure to the primary x-ray beam for each view. Large errors in dose estimation can occur if these factors are not accurately modeled. CONCLUSIONS: The effective dose of a chest examination with this chest tomosynthesis system is about twice that of a two-view chest examination and less than 2% of the published average values for thoracic CT. It is shown that complete consideration of the tomosynthesis acquisition technique and geometry is required for accurate determination of the effective dose to the patient. Tomosynthesis provides three-dimensional imaging at a dose level comparable to a two-view chest x-ray examination and may provide a low dose alternative to thoracic CT for obtaining depth information in chest imaging.


Asunto(s)
Método de Montecarlo , Dosis de Radiación , Intensificación de Imagen Radiográfica , Radiografía Torácica , Adulto , Humanos , Masculino
13.
Conf Proc IEEE Eng Med Biol Soc ; 2006: 1976-9, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-17945687

RESUMEN

We are investigating image processing and analysis techniques to improve the ability of dual-energy digital radiography (DR) for the detection of cardiac calcification. Computed tomography (CT) is an established tool for the diagnosis of coronary artery diseases. Dual-energy digital radiography could be a cost-effective alternative. In this study, we use three-dimensional (3D) CT images as the "gold standard" to evaluate the DR X-ray images for calcification detection. To this purpose, we developed an automatic registration method for 3D CT volumes and two-dimensional (2D) X-ray images. We call this 3D-to-2D registration. We first use a 3D CT image volume to simulate X-ray projection images and then register them with X-ray images. The registered CT projection images are then used to aid the interpretation dual-energy X-ray images for the detection of cardiac calcification. We acquired both CT and X-ray images from patients with coronary artery diseases. Experimental results show that the 3D-to-2D registration is accurate and useful for this new application.


Asunto(s)
Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Imagenología Tridimensional/métodos , Intensificación de Imagen Radiográfica/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Técnica de Sustracción , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Inteligencia Artificial , Calcinosis/diagnóstico por imagen , Humanos , Enfermedades Pulmonares/diagnóstico por imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad