1.
Rev Sci Instrum ; 86(1): 013502, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25638081

RESUMEN

The paper concerns fast protons and neutrons from D-D fusion reactions in a Plasma-Focus-1000U facility. Measurements were performed with nuclear-track detectors arranged in "sandwiches" of an Al-foil and two PM-355 detectors separated by a polyethylene-plate. The Al-foil eliminated all primary deuterons, but was penetrable for fast fusion protons. The foil and first PM-355 detector were penetrable for fast neutrons, which were converted into recoil-protons in the polyethylene and recorded in the second PM-355 detector. The "sandwiches" were irradiated by discharges of comparable neutron-yields. Analyses of etched tracks and computer simulations of the fusion-products behavior in the detectors were performed.

2.
Rev Sci Instrum ; 84(1): 016107, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23387713

RESUMEN

The Note reports on experimental studies of ripple born fast electrons within the TORE-SUPRA facility, which were performed by means of a modified measuring head equipped with diamond detectors designed especially for recording the electron-induced Cherenkov radiation. There are presented signals produced by fast electrons in the TORE-SUPRA machine, which were recorded during two experimental campaigns performed in 2010. Shapes of these electron-induced signals are considerably different from those observed during the first measurements carried out by the prototype Cherenkov probe in 2008. An explanation of the observed differences is given.

3.
Rev Sci Instrum ; 83(8): 083505, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22938292

RESUMEN

A diagnostic technique based on the Cherenkov effect is proposed for detection and characterization of fast (super-thermal and runaway) electrons in fusion devices. The detectors of Cherenkov radiation have been specially designed for measurements in the ISTTOK tokamak. Properties of several materials have been studied to determine the most appropriate one to be used as a radiator of Cherenkov emission in the detector. This technique has enabled the detection of energetic electrons (70 keV and higher) and the determination of their spatial and temporal variations in the ISTTOK discharges. Measurement of hard x-ray emission has also been carried out in experiments for validation of the measuring capabilities of the Cherenkov-type detector and a high correlation was found between the data of both diagnostics. A reasonable agreement was found between experimental data and the results of numerical modeling of the runaway electron generation in ISTTOK.

4.
Rev Sci Instrum ; 81(10): 10D304, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21033830

RESUMEN

A diagnostics capable of characterizing the runaway and superthermal electrons has been developing on the ISTTOK tokamak. In previous paper, a use of single-channel Cherenkov-type detector with titanium filter for runaway electron studies in ISTTOK was reported. To measure fast electron populations with different energies, a prototype of a four-channel detector with molybdenum filters was designed. Test-stand studies of filters with different thicknesses (1, 3, 7, 10, 20, 50, and 100 µm) have shown that they should allow the detection of electrons with energies higher than 69, 75, 87, 95, 120, 181, and 260 keV, respectively. First results of measurements with the four-channel detector revealed the possibility to measure reliably different fast electrons populations simultaneously.

5.
Rev Sci Instrum ; 81(1): 013504, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20113097

RESUMEN

The paper presents a schematic design and tests of a system applicable for measurements of fast electron pulses emitted from high-temperature plasma generated inside magnetic confinement fusion machines, and particularly in the TORE-SUPRA facility. The diagnostic system based on the registration of the Cherenkov radiation induced by fast electrons within selected solid radiators is considered, and electron low-energy thresholds for different radiators are given. There are some estimates of high thermal loads, which might be deposited by intense electron beams upon parts of the diagnostic equipment within the TORE-SUPRA device. There are some proposed measures to overcome this difficulty by the selection of appropriate absorption filters and Cherenkov radiators, and particularly by the application of a fast-moving reciprocating probe. The paper describes the measuring system, its tests, as well as some results of the preliminary measurements of fast electrons within TORE-SUPRA facility.

6.
Rev Sci Instrum ; 80(5): 053504, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19485504

RESUMEN

The paper presents an improved version of a miniature mass-spectrometer of the Thomson-type, which has been adopted for ion analysis near the dense plasma region inside a vacuum chamber. Problems connected with the separation of ions from plasma streams are considered. Input diaphragms and pumping systems, needed to ensure good vacuum inside the analyzing region, are described. The application of the miniature Thomson-type analyzer is illustrated by ion parabolas recorded in plasma-focus facility and rod plasma injector experiment. A quantitative analysis of the recorded ion parabolas is presented. Factors influencing accuracy of the ion analysis are discussed and methods of the spectrometer calibration are described.

7.
Rev Sci Instrum ; 79(10): 10F505, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19044650

RESUMEN

Gas, fluid, or solid Cherenkov-type detectors have been widely used in high-energy physics for determination of parameters of charged particles, which are moving with relativistic velocities. This paper presents experimental results on the detection of runaway electrons using Cherenkov-type detectors in the ISTTOK tokamak discharges. Such detectors have been specially designed for measurements of energetic electrons in tokamak plasma. The technique based on the use of the Cherenkov-type detectors has enabled the detection of energetic electrons (energies higher than 80 keV) and determination of their spatial and temporal parameters in the ISTTOK discharges. Obtained experimental data were found in adequate agreement to the results of numerical modeling of the runaway electron generation in ISTTOK.