Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Am Soc Mass Spectrom ; 35(8): 1826-1837, 2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39057601

RESUMEN

Labeling with deuterium oxide (D2O) has emerged as one of the preferred approaches for measuring the synthesis of individual proteins in vivo. In these experiments, the synthesis rates of proteins are determined by modeling mass shifts in peptides during the labeling period. This modeling depends on a theoretical maximum enrichment determined by the number of labeling sites (NEH) of each amino acid in the peptide sequence. Currently, NEH is determined from one set of published values. However, it has been demonstrated that NEH can differ between species and potentially tissues. The goal of this work was to determine the number of NEH for each amino acid within a given experiment to capture the conditions unique to that experiment. We used four methods to compute the NEH values. To test these approaches, we used two publicly available data sets. In a de novo approach, we compute NEH values and the label enrichment from the abundances of three mass isotopomers. The other three methods use the complete isotope profiles and body water enrichment in deuterium as an input parameter. They determine the NEH values by (1) minimizing the residual sum of squares, (2) from the mole percent excess of labeling, and (3) the time course profile of the depletion of the relative isotope abundance of monoisotope. In the test samples, the method using residual sum of squares performed the best. The methods are implemented in a tool for determining the NEH for each amino acid within a given experiment to use in the determination of protein synthesis rates using D2O.


Asunto(s)
Cromatografía Líquida con Espectrometría de Masas , Animales , Aminoácidos/química , Aminoácidos/análisis , Aminoácidos/metabolismo , Óxido de Deuterio , Cromatografía Líquida con Espectrometría de Masas/métodos , Péptidos/química , Péptidos/análisis , Proteínas/química , Proteínas/análisis , Proteínas/metabolismo
2.
J Proteome Res ; 23(6): 2298-2305, 2024 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-38809146

RESUMEN

Multiple hypothesis testing is an integral component of data analysis for large-scale technologies such as proteomics, transcriptomics, or metabolomics, for which the false discovery rate (FDR) and positive FDR (pFDR) have been accepted as error estimation and control measures. The pFDR is the expectation of false discovery proportion (FDP), which refers to the ratio of the number of null hypotheses to that of all rejected hypotheses. In practice, the expectation of ratio is approximated by the ratio of expectation; however, the conditions for transforming the former into the latter have not been investigated. This work derives exact integral expressions for the expectation (pFDR) and variance of FDP. The widely used approximation (ratio of expectations) is shown to be a particular case (in the limit of a large sample size) of the integral formula for pFDR. A recurrence formula is provided to compute the pFDR for a predefined number of null hypotheses. The variance of FDP was approximated for a practical application in peptide identification using forward and reversed protein sequences. The simulations demonstrate that the integral expression exhibits better accuracy than the approximate formula in the case of a small number of hypotheses. For large sample sizes, the pFDRs obtained by the integral expression and approximation do not differ substantially. Applications to proteomics data sets are included.


Asunto(s)
Proteómica , Proteómica/métodos , Algoritmos , Reacciones Falso Positivas , Péptidos/análisis , Péptidos/química , Péptidos/metabolismo , Simulación por Computador , Humanos
3.
Int J Mol Sci ; 24(21)2023 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-37958536

RESUMEN

Bioinformatics tools are used to estimate in vivo protein turnover rates from the LC-MS data of heavy water labeled samples in high throughput. The quantification includes peak detection and integration in the LC-MS domain of complex input data of the mammalian proteome, which requires the integration of results from different experiments. The existing software tools for the estimation of turnover rate use predefined, built-in, stringent filtering criteria to select well-fitted peptides and determine turnover rates for proteins. The flexible control of filtering and quality measures will help to reduce the effects of fluctuations and interferences to the signals from target peptides while retaining an adequate number of peptides. This work describes an approach for flexible error control and filtering measures implemented in the computational tool d2ome for automating protein turnover rates. The error control measures (based on spectral properties and signal features) reduced the standard deviation and tightened the confidence intervals of the estimated turnover rates.


Asunto(s)
Péptidos , Programas Informáticos , Animales , Péptidos/química , Espectrometría de Masas/métodos , Proteoma/metabolismo , Control de Calidad , Mamíferos/metabolismo
4.
Sci Data ; 10(1): 635, 2023 09 19.
Artículo en Inglés | MEDLINE | ID: mdl-37726365

RESUMEN

Metabolic stable isotope labeling with heavy water followed by liquid chromatography coupled with mass spectrometry (LC-MS) is a powerful tool for in vivo protein turnover studies. Several algorithms and tools have been developed to determine the turnover rates of peptides and proteins from time-course stable isotope labeling experiments. The availability of benchmark mass spectrometry data is crucial to compare and validate the effectiveness of newly developed techniques and algorithms. In this work, we report a heavy water-labeled LC-MS dataset from the murine liver for protein turnover rate analysis. The dataset contains eighteen mass spectral data with their corresponding database search results from nine different labeling durations and quantification outputs from d2ome+ software. The dataset also contains eight mass spectral data from two-dimensional fractionation experiments on unlabeled samples.


Asunto(s)
Hígado , Proteoma , Animales , Ratones , Cromatografía Liquida , Óxido de Deuterio , Espectrometría de Masas en Tándem
5.
Commun Chem ; 6(1): 72, 2023 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-37069333

RESUMEN

Heavy water metabolic labeling followed by liquid chromatography coupled with mass spectrometry is a powerful high throughput technique for measuring the turnover rates of individual proteins in vivo. The turnover rate is obtained from the exponential decay modeling of the depletion of the monoisotopic relative isotope abundance. We provide theoretical formulas for the time course dynamics of six mass isotopomers and use the formulas to introduce a method that utilizes partial isotope profiles, only two mass isotopomers, to compute protein turnover rate. The use of partial isotope profiles alleviates the interferences from co-eluting contaminants in complex proteome mixtures and improves the accuracy of the estimation of label enrichment. In five different datasets, the technique consistently doubles the number of peptides with high goodness-of-fit characteristics of the turnover rate model. We also introduce a software tool, d2ome+, which automates the protein turnover estimation from partial isotope profiles.

6.
J Proteome Res ; 22(2): 410-419, 2023 02 03.
Artículo en Inglés | MEDLINE | ID: mdl-36692003

RESUMEN

Retention time (RT) alignment has been important for robust protein identification and quantification in proteomics. In data-dependent acquisition mode, whereby the precursor ions are semistochastically chosen for fragmentation in MS/MS, the alignment is used in an approach termed matched between runs (MBR). MBR transfers peptides, which were fragmented and identified in one experiment, to a replicate experiment where they were not identified. Before the MBR transfer, the RTs of experiments are aligned to reduce the chance of erroneous transfers. Despite its widespread use in other areas of quantitative proteomics, RT alignment has not been applied in data analyses for protein turnover using an atom-based stable isotope-labeling agent such as metabolic labeling with deuterium oxide, D2O. Deuterium incorporation changes isotope profiles of intact peptides in full scans and their fragment ions in tandem mass spectra. It reduces the peptide identification rates in current database search engines. Therefore, the MBR becomes more important. Here, we report on an approach to incorporate RT alignment with peptide quantification in studies of proteome turnover using heavy water metabolic labeling and LC-MS. The RT alignment uses correlation-optimized time warping. The alignment, followed by the MBR, improves labeling time point coverage, especially for long labeling durations.


Asunto(s)
Péptidos , Espectrometría de Masas en Tándem , Óxido de Deuterio , Proteoma/metabolismo , Isótopos , Marcaje Isotópico
7.
Int J Mol Sci ; 23(23)2022 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-36498948

RESUMEN

Metabolic stable isotope labeling followed by liquid chromatography coupled with mass spectrometry (LC-MS) is a powerful tool for in vivo protein turnover studies of individual proteins on a large scale and with high throughput. Turnover rates of thousands of proteins from dozens of time course experiments are determined by data processing tools, which are essential components of the workflows for automated extraction of turnover rates. The development of sophisticated algorithms for estimating protein turnover has been emphasized. However, the visualization and annotation of the time series data are no less important. The visualization tools help to validate the quality of the model fits, their goodness-of-fit characteristics, mass spectral features of peptides, and consistency of peptide identifications, among others. Here, we describe a graphical user interface (GUI) to visualize the results from the protein turnover analysis tool, d2ome, which determines protein turnover rates from metabolic D2O labeling followed by LC-MS. We emphasize the specific features of the time series data and their visualization in the GUI. The time series data visualized by the GUI can be saved in JPEG format for storage and further dissemination.


Asunto(s)
Programas Informáticos , Espectrometría de Masas en Tándem , Cromatografía Liquida/métodos , Óxido de Deuterio , Espectrometría de Masas en Tándem/métodos , Marcaje Isotópico/métodos , Proteínas , Péptidos/química
8.
Brief Bioinform ; 23(2)2022 03 10.
Artículo en Inglés | MEDLINE | ID: mdl-35062023

RESUMEN

Protein turnover is vital for cellular functioning and is often associated with the pathophysiology of a variety of diseases. Metabolic labeling with heavy water followed by liquid chromatography coupled to mass spectrometry is a powerful tool to study in vivo protein turnover in high throughput and large scale. Heavy water is a cost-effective and easy to use labeling agent. It labels all nonessential amino acids. Due to its toxicity in high concentrations (20% or higher), small enrichments (8% or smaller) of heavy water are used with most organisms. The low concentration results in incomplete labeling of peptides/proteins. Therefore, the data processing is more challenging and requires accurate quantification of labeled and unlabeled forms of a peptide from overlapping mass isotopomer distributions. The work describes the bioinformatics aspects of the analysis of heavy water labeled mass spectral data, available software tools and current challenges and opportunities.


Asunto(s)
Péptidos , Espectrometría de Masas en Tándem , Cromatografía Liquida/métodos , Óxido de Deuterio/análisis , Óxido de Deuterio/metabolismo , Marcaje Isotópico/métodos , Péptidos/metabolismo , Proteolisis , Espectrometría de Masas en Tándem/métodos
10.
J Proteome Res ; 20(4): 2035-2041, 2021 04 02.
Artículo en Inglés | MEDLINE | ID: mdl-33661639

RESUMEN

Metabolic labeling followed by LC-MS-based proteomics is a powerful tool to study proteome dynamics in high-throughput experiments both in vivo and in vitro. High mass resolution and accuracy allow differentiation in isotope profiles and the quantification of partially labeled peptide species. Metabolic labeling duration introduces a time domain in which the gradual incorporation of labeled isotopes is recorded. Different stable isotopes are used for labeling. Labeling with heavy water has advantages because it is cost-effective and easy to use. The protein degradation rate constant has been modeled using exponential decay models for the relative abundances of mass isotopomers. The recently developed closed-form equations were applied to study the analytic behavior of the heavy mass isotopomers in the time domain of metabolic labeling. The predictions from the closed-form equations are compared with the practices that have been used to extract degradation rate constants from the time-course profiles of heavy mass isotopomers. It is shown that all mass isotopomers, except for the monoisotope, require data transformations to obtain the exponential depletion, which serves as a basis for the rate constant model. Heavy mass isotopomers may be preferable choices for modeling high-mass peptides or peptides with a high number of labeling sites. The results are also applicable to stable isotope labeling with other atom-based labeling agents.


Asunto(s)
Espectrometría de Masas en Tándem , Cromatografía Liquida , Óxido de Deuterio , Marcaje Isotópico , Proteolisis
11.
Bioinformatics ; 37(6): 837-844, 2021 05 05.
Artículo en Inglés | MEDLINE | ID: mdl-33067612

RESUMEN

MOTIVATION: Inferring the direct relationships between biomolecules from omics datasets is essential for the understanding of biological and disease mechanisms. Gaussian Graphical Model (GGM) provides a fairly simple and accurate representation of these interactions. However, estimation of the associated interaction matrix using data is challenging due to a high number of measured molecules and a low number of samples. RESULTS: In this article, we use the thermodynamic entropy of the non-equilibrium system of molecules and the data-driven constraints among their expressions to derive an analytic formula for the interaction matrix of Gaussian models. Through a data simulation, we show that our method returns an improved estimation of the interaction matrix. Also, using the developed method, we estimate the interaction matrix associated with plasma proteome and construct the corresponding GGM and show that known NAFLD-related proteins like ADIPOQ, APOC, APOE, DPP4, CAT, GC, HP, CETP, SERPINA1, COLA1, PIGR, IGHD, SAA1 and FCGBP are among the top 15% most interacting proteins of the dataset. AVAILABILITY AND IMPLEMENTATION: The supplementary materials can be found in the following URL: http://dynamic-proteome.utmb.edu/PrecisionMatrixEstimater/PrecisionMatrixEstimater.aspx. SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online.


Asunto(s)
Algoritmos , Proteoma , Simulación por Computador , Entropía , Distribución Normal
12.
Int J Mol Sci ; 21(21)2020 Oct 22.
Artículo en Inglés | MEDLINE | ID: mdl-33105654

RESUMEN

Cellular proteins are continuously degraded and synthesized. The turnover of proteins is essential to many cellular functions. Combined with metabolic labeling using stable isotopes, LC-MS estimates proteome dynamics in high-throughput and on a large scale. Modern mass spectrometers allow a range of instrumental settings to optimize experimental output for specific research goals. One such setting which affects the results for dynamic proteome studies is the mass resolution. The resolution is vital for distinguishing target species from co-eluting contaminants with close mass-to-charge ratios. However, for estimations of proteome dynamics from metabolic labeling with stable isotopes, the spectral accuracy is highly important. Studies examining the effects of increased mass resolutions (in modern mass spectrometers) on the proteome turnover output and accuracy have been lacking. Here, we use a publicly available heavy water labeling and mass spectral data sets of murine serum proteome (acquired on Orbitrap Fusion and Agilent 6530 QToF) to analyze the effect of mass resolution of the Orbitrap mass analyzer on the proteome dynamics estimation. Increased mass resolution affected the spectral accuracy and the number acquired tandem mass spectra.


Asunto(s)
Proteínas Sanguíneas/análisis , Deuterio/química , Espectrometría de Masas/métodos , Proteómica/métodos , Animales , Proteínas Sanguíneas/metabolismo , Marcaje Isotópico , Ratones Endogámicos C57BL , Albúmina Sérica/análisis , Albúmina Sérica/química
13.
Anal Chem ; 92(21): 14747-14753, 2020 11 03.
Artículo en Inglés | MEDLINE | ID: mdl-33084301

RESUMEN

Metabolic labeling with atom-based heavy isotopes, followed by liquid chromatography coupled with mass spectrometry (LC-MS), has been a powerful technique for studies of proteome and metabolome. In proteomics, the protein turnover of thousands of proteins can be estimated from the gradual incorporation of 2H or 15N in the diet. Software tools have been developed to automate the estimation of protein turnover. Traditionally, the turnover has been estimated using the time course of the depletion of the normalized abundance of monoisotopes. While the bioinformatic aspects of peak detection and integration, time course modeling, and uncertainty estimation have progressed, mass isotopomer dynamics during label incorporation has only been modeled from approximate approaches or numerical simulations. We derive closed-form equations that describe the dynamics of mass isotopomers during metabolic labeling with an atom-based stable isotope. The derived equations create an alternative method for estimating label incorporation. They also provide opportunities for estimation of precursor-product relationships in species or systems where they are unknown. The equations are useful in bioinformatic tools for analyzing mass spectral data from metabolic labeling.


Asunto(s)
Metabolómica/métodos , Cromatografía Liquida , Marcaje Isotópico , Espectrometría de Masas en Tándem
14.
J Proteome Res ; 19(5): 2105-2112, 2020 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-32183509

RESUMEN

Protein homeostasis, proteostasis, is essential for healthy cell functioning and is dysregulated in many diseases. Metabolic labeling with heavy water followed by liquid chromatography coupled online to mass spectrometry (LC-MS) is a powerful high-throughput technique to study proteome dynamics in vivo. Longer labeling duration and dense timepoint sampling (TPS) of tissues provide accurate proteome dynamics estimations. However, the experiments are expensive, and they require animal housing and care, as well as labeling with stable isotopes. Often, the animals are sacrificed at selected timepoints to collect tissues. Therefore, it is necessary to optimize TPS for a given number of sampling points and labeling duration and target a specific tissue of study. Currently, such techniques are missing in proteomics. Here, we report on a formula-based stochastic simulation strategy for TPS for in vivo studies with heavy water metabolic labeling and LC-MS. We model the rate constant (lognormal), measurement error (Laplace), peptide length (gamma), relative abundance of the monoisotopic peak (beta regression), and the number of exchangeable hydrogens (gamma regression). The parameters of the distributions are determined using the corresponding empirical probability density functions from a large-scale dataset of murine heart proteome. The models are used in the simulations of the rate constant to minimize the root-mean-square error (rmse). The rmse for different TPSs shows structured patterns. They are analyzed to elucidate common features in the patterns.


Asunto(s)
Proteoma , Espectrometría de Masas en Tándem , Animales , Cromatografía Liquida , Óxido de Deuterio , Marcaje Isotópico , Ratones
15.
Anal Chem ; 91(22): 14340-14351, 2019 11 19.
Artículo en Inglés | MEDLINE | ID: mdl-31638786

RESUMEN

Rate constant estimation with heavy water requires a long-term experiment with data collection at multiple time points (3-4 weeks for mitochondrial proteome dynamics in mice and much longer in other species). When tissue proteins are analyzed, this approach requires euthanizing animals at each time point or multiple tissue biopsies in humans. Although short-term protocols are available, they require knowledge of the maximum number of isotope labels (N) and accurate quantification of observed 2H-enrichment in the peptide. The high-resolution accurate mass spectrometers used for proteome dynamics studies are characterized by a systematic spectral error that compromises these measurements. To circumvent these issues, we developed a simple algorithm for the rate constant calculation based on a single labeled sample and comparable unlabeled (time 0) sample. The algorithm determines N for all proteogenic amino acids from a long-term experiment to calculate the predicted plateau 2H-labeling of peptides for a short-term protocol and estimates the rate constant based on the measured baseline and the predicted plateau 2H-labeling of peptides. The method was validated based on the rate constant estimation in a long-term experiment in mice and dogs. The improved 2 time-point method enables the rate constant calculation with less than 10% relative error compared to the bench-marked multi-point method in mice and dogs and allows us to detect diet-induced subtle changes in ApoAI turnover in mice. In conclusion, we have developed and validated a new algorithm for protein rate constant calculation based on 2-time point measurements that could also be applied to other biomolecules.


Asunto(s)
Aminoácidos/análisis , Péptidos/química , Proteínas/química , Proteómica/métodos , Algoritmos , Aminoácidos/metabolismo , Animales , Deuterio/análisis , Deuterio/metabolismo , Perros , Marcaje Isotópico/métodos , Masculino , Ratones , Ratones Endogámicos C57BL , Péptidos/metabolismo , Proteínas/metabolismo , Espectrometría de Masas en Tándem/métodos
16.
Bioinformatics ; 35(22): 4748-4753, 2019 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-31081021

RESUMEN

MOTIVATION: High throughput technologies are widely employed in modern biomedical research. They yield measurements of a large number of biomolecules in a single experiment. The number of experiments usually is much smaller than the number of measurements in each experiment. The simultaneous measurements of biomolecules provide a basis for a comprehensive, systems view for describing relevant biological processes. Often it is necessary to determine correlations between the data matrices under different conditions or pathways. However, the techniques for analyzing the data with a low number of samples for possible correlations within or between conditions are still in development. Earlier developed correlative measures, such as the RV coefficient, use the trace of the product of data matrices as the most relevant characteristic. However, a recent study has shown that the RV coefficient consistently overestimates the correlations in the case of low sample numbers. To correct for this bias, it was suggested to discard the diagonal elements of the outer products of each data matrix. In this work, a principled approach based on the matrix decomposition generates three trace-independent parts for every matrix. These components are unique, and they are used to determine different aspects of correlations between the original datasets. RESULTS: Simulations show that the decomposition results in the removal of high correlation bias and the dependence on the sample number intrinsic to the RV coefficient. We then use the correlations to analyze a real proteomics dataset. AVAILABILITY AND IMPLEMENTATION: The python code can be downloaded from http://dynamic-proteome.utmb.edu/MatrixCorrelations.aspx. SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online.


Asunto(s)
Algoritmos , Proteómica
17.
Int J Mass Spectrom ; 4452019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32055233

RESUMEN

Protein homeostasis (proteostasis) is a result of a dynamic equilibrium between protein synthesis and degradation. It is important for healthy cell/organ functioning and is often associated with diseases such as neurodegenerative diseases and non-Alcoholic Fatty Liver disease. Heavy water metabolic labeling, combined with liquid-chromatography and mass spectrometry (LC-MS), is a powerful approach to study proteostasis in vivo in high throughput. Traditionally, intact peptide signals are used to estimate stable isotope incorporation in time-course experiments. The time-course of label incorporation is used to extract protein decay rate constant (DRC). Intact peptide signals, computed from integration in chromatographic time and mass-to-charge ratio (m/z) domains, usually, provide an accurate estimate of label incorporation. However, sample complexity (co-elution), limited dynamic range, and low signal-to-noise ratio (S/N) may adversely interfere with the peptide signals. These artifacts complicate the DRC estimations by distorting peak shape in chromatographic time and m/z domains. Fragment ions, on the other hand, are less prone to these artifacts and are potentially well suited in aiding DRC estimations. Here, we show that the label incorporation encoded into the isotope distributions of fragment ions reflect the isotope enrichment during the metabolic labeling with heavy water. We explore the label incorporation statistics for devising practical approaches for DRC estimations.

18.
Mol Cell Proteomics ; 17(12): 2371-2386, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30171159

RESUMEN

Nonalcoholic fatty liver disease (NAFLD) is associated with hepatic mitochondrial dysfunction characterized by reduced ATP synthesis. We applied the 2H2O-metabolic labeling approach to test the hypothesis that the reduced stability of oxidative phosphorylation proteins contributes to mitochondrial dysfunction in a diet-induced mouse model of NAFLD. A high fat diet containing cholesterol (a so-called Western diet (WD)) led to hepatic oxidative stress, steatosis, inflammation and mild fibrosis, all markers of NAFLD, in low density cholesterol (LDL) receptor deficient (LDLR-/-) mice. In addition, compared with controls (LDLR-/- mice on normal diet), livers from NAFLD mice had reduced citrate synthase activity and ATP content, suggesting mitochondrial impairment. Proteome dynamics study revealed that mitochondrial defects are associated with reduced average half-lives of mitochondrial proteins in NAFLD mice (5.41 ± 0.46 versus 5.15 ± 0.49 day, p < 0.05). In particular, the WD reduced stability of oxidative phosphorylation subunits, including cytochrome b-c1 complex subunit 1 (5.9 ± 0.1 versus 3.4 ± 0.8 day), ATP synthase subunit α (6.3 ± 0.4 versus 5.5 ± 0.4 day) and ATP synthase F(0) complex subunit B1 of complex V (8.5 ± 0.6 versus 6.5 ± 0.2 day) (p < 0.05). These changes were associated with impaired complex III and F0F1-ATP synthase activities. Markers of mitophagy were increased, but proteasomal degradation activity were reduced in NAFLD mice liver, suggesting that ATP deficiency because of reduced stability of oxidative phosphorylation complex subunits contributed to inhibition of ubiquitin-proteasome and activation of mitophagy. In conclusion, the 2H2O-metabolic labeling approach shows that increased degradation of hepatic oxidative phosphorylation subunits contributed to mitochondrial impairment in NAFLD mice.


Asunto(s)
Hígado/patología , Mitocondrias/metabolismo , Proteínas Mitocondriales/metabolismo , Mitofagia , Enfermedad del Hígado Graso no Alcohólico/metabolismo , Animales , Autofagia , Dieta Occidental/efectos adversos , Modelos Animales de Enfermedad , Ácidos Grasos/metabolismo , Semivida , Masculino , Ratones , Ratones Endogámicos C57BL , Ratones Noqueados , Mitocondrias/patología , Enfermedad del Hígado Graso no Alcohólico/inducido químicamente , Fosforilación Oxidativa , Estrés Oxidativo , Proteolisis , Proteómica/métodos , Especies Reactivas de Oxígeno/metabolismo , Espectrometría de Masas en Tándem
19.
J Proteome Res ; 17(11): 3740-3748, 2018 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-30265007

RESUMEN

Metabolic labeling with heavy water followed by LC-MS is a high throughput approach to study proteostasis in vivo. Advances in mass spectrometry and sample processing have allowed consistent detection of thousands of proteins at multiple time points. However, freely available automated bioinformatics tools to analyze and extract protein decay rate constants are lacking. Here, we describe d2ome-a robust, automated software solution for in vivo protein turnover analysis. d2ome is highly scalable, uses innovative approaches to nonlinear fitting, implements Grubbs' outlier detection and removal, uses weighted-averaging of replicates, applies a data dependent elution time windowing, and uses mass accuracy in peak detection. Here, we discuss the application of d2ome in a comparative study of protein turnover in the livers of normal vs Western diet-fed LDLR-/- mice (mouse model of nonalcoholic fatty liver disease), which contained 256 LC-MS experiments. The study revealed reduced stability of 40S ribosomal protein subunits in the Western diet-fed mice.


Asunto(s)
Óxido de Deuterio/metabolismo , Hígado/metabolismo , Enfermedad del Hígado Graso no Alcohólico/metabolismo , Proteoma/metabolismo , Proteínas Ribosómicas/metabolismo , Programas Informáticos , Animales , Cromatografía Liquida , Óxido de Deuterio/química , Dieta Occidental/efectos adversos , Modelos Animales de Enfermedad , Expresión Génica , Semivida , Marcaje Isotópico/métodos , Hígado/química , Hígado/patología , Ratones , Ratones Endogámicos C57BL , Ratones Noqueados , Enfermedad del Hígado Graso no Alcohólico/etiología , Enfermedad del Hígado Graso no Alcohólico/genética , Enfermedad del Hígado Graso no Alcohólico/patología , Mapeo de Interacción de Proteínas/estadística & datos numéricos , Proteolisis , Proteoma/química , Proteoma/genética , Proteoma/aislamiento & purificación , Proteostasis/genética , Receptores de LDL/deficiencia , Receptores de LDL/genética , Proteínas Ribosómicas/química , Proteínas Ribosómicas/genética , Proteínas Ribosómicas/aislamiento & purificación , Espectrometría de Masas en Tándem
20.
J Proteome Res ; 17(1): 751-758, 2018 01 05.
Artículo en Inglés | MEDLINE | ID: mdl-29202576

RESUMEN

We introduce a simplified computational algorithm for computing isotope distributions (relative abundances and masses) of biomolecules. The algorithm is based on Poisson approximation to binomial and multinomial distributions. It leads to a small number of arithmetic operations to compute isotope distributions of molecules. The approach uses three embedded loops to compute the isotope distributions, as compared with the eight embedded loops in exact calculations. The speed improvement is about 3-fold compared to the fast Fourier transformation-based isotope calculations, often termed as ultrafast isotope calculation. The approach naturally incorporates the determination of the masses of each molecular isotopomer. It is applicable to high mass accuracy and resolution mass spectrometry data. The application to tryptic peptides in a UniProt protein database revealed that the mass accuracy of the computed isotopomers is better than 1 ppm. Even better mass accuracy (below 1 ppm) is achievable when the method is paired with the exact calculations, which we term a hybrid approach. The algorithms have been implemented in a freely available C/C++ code.


Asunto(s)
Bases de Datos de Proteínas , Marcaje Isotópico , Distribución de Poisson , Algoritmos , Espectrometría de Masas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA