Radiol Clin North Am ; 61(6): 945-961, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37758362

RESUMEN

Compared to conventional single-energy CT (SECT), dual-energy CT (DECT) provides additional information to better characterize imaged tissues. Approaches to DECT acquisition vary by vendor and include source-based and detector-based systems, each with its own advantages and disadvantages. Despite the different approaches to DECT acquisition, the most utilized DECT images include routine SECT equivalent, virtual monoenergetic, material density (eg, iodine map), and virtual non-contrast images. These images are generated either through reconstructions in the projection or image domains. Designing and implementing an optimal DECT workflow into routine clinical practice depends on radiologist and technologist input with special considerations including appropriate patient and protocol selection and workflow automation. In addition to better tissue characterization, DECT provides numerous advantages over SECT such as the characterization of incidental findings and dose reduction in radiation and iodinated contrast.


Asunto(s)
Yodo , Imagen Radiográfica por Emisión de Doble Fotón , Humanos , Tomografía Computarizada por Rayos X/métodos , Medios de Contraste , Dosis de Radiación , Imagen Radiográfica por Emisión de Doble Fotón/métodos
2.
Diagnostics (Basel) ; 13(13)2023 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-37443673

RESUMEN

We compared the image quality of abdominopelvic single-energy CT with 100 kVp (SECT-100 kVp) and dual-energy CT with 65 keV (DECT-65 keV) obtained with customized injection protocols to standard abdominopelvic CT scans (SECT-120 kVp) with fixed volumes of contrast media (CM). We retrospectively included 91 patients (mean age, 60.7 ± 15.8 years) with SECT-100 kVp and 83 (mean age, 60.3 ± 11.7 years) patients with DECT-65 keV in portovenous phase. Total body weight-based customized injection protocols were generated by a software using the following formula: patient weight (kg) × 0.40/contrast concentration (mgI/mL) × 1000. Patients had a prior abdominopelvic SECT-120 kVp with fixed injection. Iopamidol-370 was administered for all examinations. Quantitative and qualitative image quality comparisons were made between customized and fixed injection protocols. Compared to SECT-120 kVp, customized injection yielded a significant reduction in CM volume (mean difference = 9-12 mL; p ≤ 0.001) and injection rate (mean differences = 0.2-0.4 mL/s; p ≤ 0.001) in all weight categories. Improvements in attenuation, noise, signal-to-noise and contrast-to-noise ratios were observed for both SECT-100 kVp and DECT-65 keV compared to SECT-120 kVp in all weight categories (e.g., pancreas DECT-65 keV, 1.2-attenuation-fold increase vs. SECT-120 kVp; p < 0.001). Qualitative scores were ≥4 in 172 cases (98.8.4%) with customized injections and in all cases with fixed injections (100%). These findings suggest that customized CM injection protocols may substantially reduce iodine dose while yielding higher image quality in SECT-100 kVp and DECT-65 keV abdominopelvic scans compared to SECT-120 kVp using fixed CM volumes.

3.
Abdom Radiol (NY) ; 48(4): 1514-1525, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36799998

RESUMEN

Computed tomography (CT) has witnessed tremendous growth in utilization. Despite its immense benefits, there is a growing concern from the general public and the medical community about the detrimental consequences of ionizing radiation from CT. Anxiety from the perceived risks associated with CT can deter referring physicians from ordering clinically indicated CT scans and patients from undergoing medically necessary exams. This article discusses various strategies for educating patients and healthcare providers on the benefits and risks of CT scanning and salient techniques for effective communication.


Asunto(s)
Personal de Salud , Tomografía Computarizada por Rayos X , Humanos , Dosis de Radiación , Tomografía Computarizada por Rayos X/efectos adversos
4.
Eur Radiol ; 33(2): 1318-1328, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36074261

RESUMEN

OBJECTIVES: To assess the impact of dual-energy CT (DECT) utilization in practice by measuring the readers' confidence, the need for additional image requests, and diagnostic performance in renal lesion assessment, compared to single-energy CT (SECT) using contrast-enhanced MRI to establish the reference standard. MATERIALS AND METHODS: Sixty-nine patients (M/F = 47/22) who underwent a dual-phase renal SECT (n = 34) or DECT (n = 35) and had a contrast-enhanced MRI within 180 days were retrospectively collected. Three radiologists assessed images on different sessions (SECT, DECT, and MRI) for (1) likely diagnosis (enhancing/non-enhancing); (2) diagnostic confidence (5-point Likert scale); (3) need for additional imaging test (yes/no); and (4) need for follow-up imaging (yes/no). Diagnostic accuracy was compared using AUC; p value < 0.05 was considered significant. RESULTS: One hundred fifty-six lesions consisting of 18% enhancing (n = 28/156, mean size: 30.37 mm, range: 9.9-94 mm) and 82% non-enhancing (n = 128/156, mean size: 23.91 mm, range: 5.0-94.2 mm) were included. The confidence level was significantly lower for SECT than their MRI (4.50 vs. 4.80, p value < 0.05) but not significantly different for DECT and the corresponding MRI (4.78 vs. 4.78, p > 0.05). There were significantly more requests for additional imaging in the SECT session than the corresponding MRI (20% vs. 4%), which was not significantly different between DECT and their MRI counterpart session (5.7% vs. 4.9%). Inter-reader agreement was almost perfect for DECT and MRI (kappa: 0.8-1) and substantial in SECT sessions (kappa: 0.6-0.8) with comparable diagnostic accuracy between SECT, DECT, and MRI (p value > 0.05). CONCLUSION: Single-phase DECT allows confident and reproducible characterization of renal masses with fewer recommendation for additional and follow-up imaging tests than dual-phase SECT and a performance similar to MRI. KEY POINTS: • DECT utilization leads to similar additional image requests to MRI (5.7% vs. 4.9%, p value > 0.05), whereas single-energy CT utilization leads to significantly higher image requests (20% vs. 4%, p value < 0.05). • DECT and MRI utilization bring highly reproducible results with almost perfect inter-reader agreement (kappa: 0.8-1), better than the inter-reader agreement in SECT utilization (kappa: 0.6-0.8). • Readers' confidence was not significantly altered between DECT and their MRI readout session (p value > 0.05). In contrast, confidence in the diagnosis was significantly lower in the SECT session than their MRI readout (p value < 0.05).


Asunto(s)
Imagen Radiográfica por Emisión de Doble Fotón , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Medios de Contraste , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Estudios Retrospectivos , Dosis de Radiación , Imagen por Resonancia Magnética
5.
AJR Am J Roentgenol ; 219(4): 614-623, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35441533

RESUMEN

BACKGROUND. Prior studies have provided mixed results for the ability to replace true unenhanced (TUE) images with virtual unenhanced (VUE) images when characterizing renal lesions by dual-energy CT (DECT). Detector-based dual-layer DECT (dlDECT) systems may optimize performance of VUE images for this purpose. OBJECTIVE. The purpose of this article was to compare dual-phase dlDECT examinations evaluated using VUE and TUE images in differentiating cystic and solid renal masses. METHODS. This retrospective study included 110 patients (mean age, 64.3 ± 11.8 years; 46 women, 64 men) who underwent renal-mass protocol dlDECT between July 2018 and February 2022. TUE, VUE, and nephrographic phase image sets were reconstructed. Lesions were diagnosed as solid masses by histopathology or MRI. Lesions were diagnosed as cysts by composite criteria reflecting findings from MRI, ultrasound, and the TUE and nephrographic phase images of the dlDECT examinations. One radiologist measured lesions' attenuation on all dlDECT image sets. Lesion characterization was compared between use of VUE and TUE images, including when considering enhancement of 20 HU or greater to indicate presence of a solid mass. RESULTS. The analysis included 219 lesions (33 solid masses; 186 cysts [132 simple, 20 septate, 34 hyperattenuating]). TUE and VUE attenuation were significantly different for solid masses (33.4 ± 7.1 HU vs 35.4 ± 8.6 HU, p = .002), simple cysts (10.8 ± 5.6 HU vs 7.1 ± 8.1 HU, p < .001), and hyperattenuating cysts (56.3 ± 21.0 HU vs 47.6 ± 16.3 HU, p < .001), but not septate cysts (13.6 ± 8.1 HU vs 14.0 ± 6.8 HU, p = .79). Frequency of enhancement 20 HU or greater when using TUE and VUE images was 90.9% and 90.9% in solid masses, 0.0% and 9.1% in simple cysts, 15.0% and 10.0% in septate cysts, and 11.8% and 38.2% in hyperattenuating cysts. All solid lesions were concordant in terms of enhancement 20 HU or greater when using TUE and VUE images. Twelve simple cysts and nine hyperattenuating cysts showed enhancement of 20 HU or greater when using VUE but not TUE images. CONCLUSION. Use of VUE images reliably detected enhancement in solid masses. However, VUE images underestimated attenuation of simple and hyperattenuating cysts, leading to false-positive findings of enhancement by such lesions. CLINICAL IMPACT. The findings do not support replacement of TUE acquisitions with VUE images when characterizing renal lesions by dlDECT.


Asunto(s)
Quistes , Imagen Radiográfica por Emisión de Doble Fotón , Anciano , Medios de Contraste , Femenino , Humanos , Aumento de la Imagen , Riñón , Masculino , Persona de Mediana Edad , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
8.
Abdom Radiol (NY) ; 47(9): 3003-3018, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-34468796

RESUMEN

Advances in dual-energy CT (DECT) technology and spectral techniques are catalyzing the widespread implementation of this technology across multiple radiology subspecialties. The inclusion of energy- and material-specific datasets has ushered overall improvements in CT image contrast and noise as well as artifacts reduction, leading to considerable progress in radiologists' ability to detect and characterize pathologies in the abdomen. The scope of this article is to provide an overview of various quantitative clinical DECT applications in the abdomen and pelvis. Several of the reviewed applications have not reached mainstream clinical use and are considered investigational. Nonetheless awareness of such applications is critical to having a fully comprehensive knowledge base to DECT and fostering future clinical implementation.


Asunto(s)
Abdomen , Tomografía Computarizada por Rayos X , Abdomen/diagnóstico por imagen , Artefactos , Medios de Contraste , Humanos , Tomografía Computarizada por Rayos X/métodos
10.
Radiographics ; 41(2): 509-523, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33606565

RESUMEN

Dual-energy CT (DECT) is an exciting innovation in CT technology with profound capabilities to improve diagnosis and add value to patient care. Significant advances in this technology over the past decade have improved our ability to successfully adopt DECT into the clinical routine. To enable effective use of DECT, one must be aware of the pitfalls and artifacts related to this technology. Understanding the underlying technical basis of artifacts and the strategies to mitigate them requires optimization of scan protocols and parameters. The ability of radiologists and technologists to anticipate their occurrence and provide recommendations for proper selection of patients, intravenous and oral contrast media, and scan acquisition parameters is key to obtaining good-quality DECT images. In addition, choosing appropriate reconstruction algorithms such as image kernel, postprocessing parameters, and appropriate display settings is critical for preventing quantitative and qualitative interpretive errors. Therefore, knowledge of the appearances of these artifacts is essential to prevent errors and allows maximization of the potential of DECT. In this review article, the authors aim to provide a comprehensive and practical overview of possible artifacts that may be encountered at DECT across all currently available commercial clinical platforms. They also provide a pictorial overview of the diagnostic pitfalls and outline strategies for mitigating or preventing the occurrence of artifacts, when possible. The broadening scope of DECT applications necessitates up-to-date familiarity with these technologies to realize their full diagnostic potential.


Asunto(s)
Artefactos , Imagen Radiográfica por Emisión de Doble Fotón , Algoritmos , Medios de Contraste , Humanos , Tomografía Computarizada por Rayos X
11.
Radiographics ; 41(1): 98-119, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33411614

RESUMEN

Dual-energy CT (DECT) is a tremendous innovation in CT technology that allows creation of numerous imaging datasets by enabling discrete acquisitions at more than one energy level. The wide range of images generated from a single DECT acquisition provides several benefits such as improved lesion detection and characterization, superior determination of material composition, reduction in the dose of iodine, and more robust quantification. Technological advances and the proliferation of various processing methods have led to the availability of diverse vendor-based DECT approaches, each with a different acquisition and image reconstruction process. The images generated from various DECT scanners differ from those from conventional single-energy CT because of differences in their acquisition techniques, material decomposition methods, image reconstruction algorithms, and postprocessing methods. DECT images such as virtual monochromatic images, material density images, and virtual unenhanced images have different imaging appearances, texture features, and quantitative capabilities. This heterogeneity creates challenges in their routine interpretation and has certain associated pitfalls. Some artifacts such as residual iodine on virtual unenhanced images and an appearance of pseudopneumatosis in a gas-distended bowel loop on material-density iodine images are specific to DECT, while others such as pseudoenhancement seen on virtual monochromatic images are also observed at single-energy CT. Recognizing the potential pitfalls associated with DECT is necessary for appropriate and accurate interpretation of the results of this increasingly important imaging tool. Online supplemental material is available for this article. ©RSNA, 2021.


Asunto(s)
Yodo , Imagen Radiográfica por Emisión de Doble Fotón , Artefactos , Humanos , Procesamiento de Imagen Asistido por Computador , Tomografía Computarizada por Rayos X
12.
Radiology ; 296(2): E26-E31, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32687455

RESUMEN

The coronavirus disease 2019 (COVID-19) pandemic initially manifested in the United States in the greater Seattle area and has rapidly progressed across the nation in the past 2 months, with the United States having the highest number of cases in the world. Radiology departments play a critical role in policy and guideline development both for the department and for the institutions, specifically in planning diagnostic screening, triage, and management of patients. In addition, radiology workflows, volumes, and access must be optimized in preparation for the expected surges in the number of patients with COVID-19. In this article, the authors discuss the processes that have been implemented at the University of Washington in managing the COVID-19 pandemic as well in preparing for patient surges, which may provide important guidance for other radiology departments who are in the early stages of preparation and management.


Asunto(s)
Betacoronavirus , Infecciones por Coronavirus/diagnóstico por imagen , Control de Infecciones/organización & administración , Neumonía Viral/diagnóstico por imagen , Servicio de Radiología en Hospital/organización & administración , Contaminantes Ocupacionales del Aire/análisis , COVID-19 , Prueba de COVID-19 , Técnicas de Laboratorio Clínico/métodos , Infecciones por Coronavirus/diagnóstico , Infecciones por Coronavirus/epidemiología , Infecciones por Coronavirus/prevención & control , Infecciones por Coronavirus/transmisión , Política de Salud , Humanos , Transmisión de Enfermedad Infecciosa de Paciente a Profesional/prevención & control , Tamizaje Masivo/métodos , Pandemias/prevención & control , Equipo de Protección Personal , Neumonía Viral/epidemiología , Neumonía Viral/prevención & control , Neumonía Viral/transmisión , Guías de Práctica Clínica como Asunto , SARS-CoV-2 , Washingtón
15.
Radiology ; 296(2): E26-E31, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32267209

RESUMEN

The coronavirus disease 2019 (COVID-19) pandemic initially manifested in the United States in the greater Seattle area and has rapidly progressed across the nation in the past 2 months, with the United States having the highest number of cases in the world. Radiology departments play a critical role in policy and guideline development both for the department and for the institutions, specifically in planning diagnostic screening, triage, and management of patients. In addition, radiology workflows, volumes, and access must be optimized in preparation for the expected surges in the number of patients with COVID-19. In this article, the authors discuss the processes that have been implemented at the University of Washington in managing the COVID-19 pandemic as well in preparing for patient surges, which may provide important guidance for other radiology departments who are in the early stages of preparation and management.


Asunto(s)
COVID-19 , Política de Salud , COVID-19/diagnóstico , COVID-19/terapia , Planificación en Desastres , Hospitalización , Hospitales Universitarios , Humanos , Pandemias , Guías de Práctica Clínica como Asunto , Servicio de Radiología en Hospital/legislación & jurisprudencia , Servicio de Radiología en Hospital/organización & administración , Servicio de Radiología en Hospital/estadística & datos numéricos , SARS-CoV-2 , Washingtón
16.
Abdom Radiol (NY) ; 45(9): 2902-2909, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-31996988

RESUMEN

PURPOSE: To assess the diagnostic image quality and material decomposition characteristics of portal venous phase abdominal CT scans performed on rapid kVp-switching DECT (rsDECT) in patients with large body habitus. METHODS: We retrospectively included consecutive patients with large body habitus (≥ 90 kg) undergoing portal venous phase abdominal CT scans on rsDECT scanners between Sep 2014 and March 2018. Qualitative and quantitative assessment of the DECT data sets [65 keV monoenergetic, material density iodine (MD-I) and material density water (MD-W) images] was performed for determination of image quality (IQ) and image noise. Correlation of qualitative assessment scores with weight, BMI and patients' diameter were calculated using Pearson correlation test. Optimal thresholds were calculated using AUC and Youden index to define most appropriate size cut off, below which the IQ of material density images is largely acceptable. RESULTS: The 65 keV monoenergetic images were of diagnostic quality (diagnostic acceptability, DA ≥ 3) in 97.8% of patients (n = 91/93). However, there was significant IQ degradation of MD-I images in 20.4% (n = 19/93, DA < 3) of patients. Similarly, there was significant degradation (DA < 3) of MD-W images in 26.9% (25/92). Clinically significant artifacts (PA ≥ 3/4) were seen in 31% (n = 29/93) and 32.3% (30/93) of MD-I and MD-W images respectively. Optimal threshold for diagnostic acceptability of MD-I images were 110 kg for weight and 33.5 kg/m2 for BMI. CONCLUSION: Rapid kVp-switching DECT provides diagnostically acceptable monoenergetic images for patients with large body habitus (≥ 90 kg). There is degradation of IQ in the material density specific images particularly in patients weighing > 110 kg and with BMI > 33.5 kg/m2, due to higher number of artifacts.


Asunto(s)
Imagen Radiográfica por Emisión de Doble Fotón , Abdomen , Humanos , Vena Porta , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
17.
Radiol Imaging Cancer ; 2(5): e190084, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-33778733

RESUMEN

Purpose: To explore the potential of radiomics texture features as potential biomarkers to enable detection of the presence of BRAF mutation and prediction of 5-year overall survival (OS) in stage IV colorectal cancer (CRC). Materials and Methods: In this retrospective study, a total of 145 patients (mean age, 61 years ± 14 [standard deviation {SD}]; 68 female patients and 77 male patients) with stage IV CRC who underwent molecular profiling and pretreatment contrast material-enhanced CT scans between 2004 and 2018 were included. Tumor radiomics texture features, including the mean, the SD, the mean value of positive pixels (MPP), skewness, kurtosis, and entropy, were extracted from regions of interest on CT images after applying three Laplacian-of-Gaussian filters known as spatial scaling factors (SSFs) (SSF = 2, fine; SSF = 4, medium; SSF = 6, coarse) by using specialized software; values of these parameters were also obtained without filtration (SSF = 0). The Wilcoxon rank sum test was used to assess differences between mutated versus wild-type BRAF tumors. Associations between radiomics texture features and 5-year OS were determined by using Kaplan-Meier estimators using the log-rank test and multivariate Cox proportional-hazards regression analysis. Results: The SDs and MPPs of radiomic texture features were significantly lower in BRAF mutant tumors than in wild-type BRAF tumors at SSFs of 0, 4, and 6 (P = .006, P = .007, and P = .005, respectively). Patients with skewness less than or equal to -0.75 at an SSF of 0 and a mean of greater than or equal to 17.76 at an SSF of 2 showed better 5-year OS (hazard ratio [HR], 0.53 [95% confidence interval {CI}: 0.29, 0.94]; HR, 0.40 [95% CI: 0.22, 0.71]; log-rank P = .025 and P = .002, respectively). Tumor location (right colon vs left colon vs rectum) had no significant impact on the clinical outcome (log-rank P = .53). Conclusion: Radiomics texture features can serve as potential biomarkers for determining BRAF mutation status and as predictors of 5-year OS in patients with advanced-stage CRC.Keywords: Abdomen/GI, CT, Comparative Studies, Large BowelSupplemental material is available for this article.© RSNA, 2020.


Asunto(s)
Neoplasias Colorrectales , Proteínas Proto-Oncogénicas B-raf , Anciano , Neoplasias Colorrectales/diagnóstico por imagen , Neoplasias Colorrectales/genética , Femenino , Humanos , Masculino , Persona de Mediana Edad , Mutación , Proteínas Proto-Oncogénicas B-raf/genética , Estudios Retrospectivos , Tasa de Supervivencia , Tomografía Computarizada por Rayos X
18.
Eur J Nucl Med Mol Imaging ; 47(8): 1871-1884, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-31705172

RESUMEN

PURPOSE: Intrahepatic cholangiocarcinoma (ICC) is associated with a poor prognosis with surgical resection offering the best chance for long-term survival and potential cure. However, in up to 36% of patients who undergo surgery, more extensive disease is found at time of operation requiring cancellation of surgery. PET/MR is a novel hybrid technology that might improve local and whole-body staging in ICC patients, potentially influencing clinical management. This study was aimed to investigate the possible management implications of PET/MR, relative to conventional imaging, in patients affected by untreated intrahepatic cholangiocarcinoma. METHODS: Retrospective review of the clinicopathologic features of 37 patients with iCCC, who underwent PET/MR between September 2015 and August 2018, was performed to investigate the management implications that PET/MR had exerted on the affected patients, relative to conventional imaging. RESULTS: Of the 37 patients enrolled, median age 63.5 years, 20 (54%) were female. The same day PET/CT was performed in 26 patients. All patients were iCCC-treatment-naïve. Conventional imaging obtained as part of routine clinical care demonstrated early-stage resectable disease for 15 patients and advanced stage disease beyond the scope of surgical resection for 22. PET/MR modified the clinical management of 11/37 (29.7%) patients: for 5 patients (13.5%), the operation was cancelled due to identification of additional disease, while 4 "inoperable" patients (10.8%) underwent an operation. An additional 2 patients (5.4%) had a significant change in their operative plan based on PET/MR. CONCLUSIONS: When compared with standard imaging, PET/MR significantly influenced the treatment plan in 29.7% of patients with iCCC. TRIAL REGISTRATION: 2018P001334.


Asunto(s)
Neoplasias de los Conductos Biliares , Colangiocarcinoma , Neoplasias de los Conductos Biliares/diagnóstico por imagen , Neoplasias de los Conductos Biliares/patología , Neoplasias de los Conductos Biliares/cirugía , Colangiocarcinoma/diagnóstico por imagen , Colangiocarcinoma/patología , Femenino , Fluorodesoxiglucosa F18 , Humanos , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones , Radiofármacos , Estudios Retrospectivos
19.
Cardiovasc Diagn Ther ; 9(Suppl 1): S97-S115, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31559157

RESUMEN

Innovations in surgical techniques coupled with advances in medical and pharmacological management in the past few decades have enabled organ transplantation to become integral to the management of end stage organ failure. In this review article, we will review the role of the radiologist in the work up of liver and pancreas donors during evaluation of their donor candidacy. The critical role of imaging in assessing the parenchymal, biliary and vascular anatomy in liver donor candidates will be reviewed, as well as highlighting the anatomical findings that may pose a contraindication to transplantation. The limited role of imaging in pancreas donor evaluation is also covered, as well as a brief overview of the surgical techniques available and how the radiologist's findings influence operative technique selection.

20.
Radiology ; 291(3): 620-629, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30964423

RESUMEN

Background Substantial gain in the attenuation of iodine on low-kVp and dual-energy CT processed low-keV virtual monochromatic images provides an opportunity for customization of positive oral contrast media administration. Purpose To perform an intrapatient comparison of bowel labeling, opacification, and taste preference with iodinated oral contrast medium (ICM) in standard (sICM) and 25%-reduced (rICM) concentrations at low tube voltage (100 kVp) or on low-energy (50-70 keV) virtual monochromatic images compared with barium-based oral contrast medium (BCM) at 120 kVp. Materials and Methods In this prospective clinical trial, 200 adults (97 men, 103 women; mean age, 63 years ± 13 [standard deviation]) who weighed less than 113 kg and who were undergoing oncologic surveillance (from April 2017 to July 2018) and who had previously undergone 120-kVp abdominopelvic CT with BCM randomly received sICM (7.2 g iodine) or rICM (5.4 g iodine) and underwent 100-kVp CT or dual-energy CT (80/140 kVp) scans to be in one of four groups (n = 50 each): sICM/100 kVp, rICM/100 kVp, sICM/dual-energy CT, and rICM/dual-energy CT. Qualitative analysis was performed for image quality (with a five-point scale), extent of bowel labeling, and homogeneity of opacification (with a four-point scale). Intraluminal attenuation of opacified small bowel was measured. A post-CT patient survey was performed to indicate contrast medium preference, taste of ICM (with a five-point scale), and adverse effects. Data were analyzed with analogs of analysis of variance. Results All CT studies were of diagnostic image quality (3.4 ± 0.3), with no difference in the degree of bowel opacification between sICM and rICM (P > .05). Compared with BCM/120 kVp (282 HU ± 73), mean attenuation was 78% higher with sICM/100 kVp (459 HU ± 282) and 26%-121% higher at sICM/50-65 keV (50 keV = 626 HU ± 285; 65 keV = 356 HU ± 171). With rICM, attenuation was 46% higher for 100 kVp (385 HU ± 215) and 19%-108% higher for 50-65 keV (50 keV = 567 HU ± 270; 65 keV = 325 HU ± 156) compared with BCM (P < .05). A total of 171 of 200 study participants preferred ICM to BCM, with no taste differences between sICM and rICM (3.9 ± 0.6). Fifteen participants had diarrhea with BCM, but none had diarrhea with ICM. Conclusion A 25%-reduced concentration of iodinated oral contrast medium resulted in acceptable bowel labeling while yielding substantially higher luminal attenuation at low-kVp and low-keV CT examinations with improved preference in patients undergoing treatment for cancer. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Laghi in this issue.


Asunto(s)
Medios de Contraste , Neoplasias/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Anciano , Bario/administración & dosificación , Bario/efectos adversos , Medios de Contraste/administración & dosificación , Medios de Contraste/efectos adversos , Medios de Contraste/química , Diarrea , Femenino , Humanos , Yodo/administración & dosificación , Yodo/efectos adversos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Radiografía Abdominal , Tomografía Computarizada por Rayos X/efectos adversos