1.
Clin Hemorheol Microcirc ; 79(1): 19-26, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34420947

RESUMEN

BACKGROUND: Mechanical thrombectomy (MT) is a standard stroke treatment for patients with large vessel occlusions (LVOs). A decisive factor for a successful outcome is, among other things, timely treatment. OBJECTIVE: The objective was to analyze several time points in relation to outcomes and/or surrogate parameters. Furthermore, our data was placed in the context of other clinical trial data. METHODS: We retrospectively evaluated 133 data sets from patients who underwent MT. The correlation of various time periods with parameters, such as the ASPECTS, NIHSS, mRS, and, particularly, the TICI score, was investigated. RESULTS: A correlation was found for both the NIHSS score at discharge and the TICI score with the time periods of arrival and/or start to groin puncture as well as with arrival to the end of the intervention and the duration of the intervention. CONCLUSIONS: This retrospective study is consistent with large randomized clinical trials investigating stroke management and provides data from daily clinical practice.


Asunto(s)
Isquemia Encefálica , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Isquemia Encefálica/cirugía , Humanos , Estudios Retrospectivos , Accidente Cerebrovascular/cirugía , Trombectomía , Resultado del Tratamiento
2.
World Neurosurg ; 110: e766-e775, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29180089

RESUMEN

BACKGROUND: Treating wide-necked aneurysms is challenging for the interventional neuroradiologist. Recently, numerous devices dedicated to the treatment of these aneurysms have become available. We report our early experience using the pCONus2 device and present the technical success rate, clinical outcomes, and immediate angiographic occlusion rates. METHODS: We performed a retrospective review of prospectively collected data to identify patients treated with the pCONus2 device between February 2015 and February 2017. RESULTS: We identified 12 patients (10 females) treated with the pCONus2 device. The average patient age was 56.6 ± 15.8 years (range, 13-71 years). The average aneurysm dome width was 8.83 ± 5.3 mm (range, 3.8-20 mm), the average dome height was 7.23 ± 4.06 mm (range, 3.36-15 mm), and the average neck width was 5.88 ± 2.92 mm (range, 2.77-11 mm). The angulation of the aneurysm to the parent vessel varied between 0 and 78° (mean, 32.2°). Ten aneurysms were located in the anterior circulation, and 2 were in the posterior circulation. Immediate posttreatment angiography showed 11 aneurysms with modified Raymond-Roy classification (mRRC) grade I occlusion and 1 aneurysm with mRRC grade II occlusion. There were no deaths or hemorrhagic complications. Three patients developed small thrombi during treatment, all of whom were successfully treated with glycoprotein IIb/IIIa antagonists. Early angiographic follow-up data for 6 patients showed adequate aneurysm occlusion in 5 patients and aneurysm recanalization in 1 patient. CONCLUSIONS: The early results on the use of the pCONus2 device suggest that it can be useful for treating wide-necked aneurysms; however, larger studies with longer-term follow-up data are needed.


Asunto(s)
Angiografía Cerebral , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Stents , Adolescente , Adulto , Anciano , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Neuroquirúrgicos , Estudios Prospectivos , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven