Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Neuromodulation ; 20(6): 553-557, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28726312

RESUMEN

INTRODUCTION: Surgical site infection is a potential complication of spinal cord stimulator (SCS) implantation. Current understanding of the epidemiology, diagnosis, and treatment of these infections is based largely on small clinical studies, many of which are outdated. Evidence-based guidelines for management of SCS-related infections thus rely instead on expert opinion, case reports, and case series. In this study, we aim to provide a large scale retrospective study of infection management techniques specifically for SCS implantation. METHODS: A multicenter retrospective study of SCS implants performed over a seven-year period at 11 unique academic and non-academic institutions in the United States. All infections and related complications in this cohort were analyzed. RESULTS: Within our study of 2737 SCS implant procedures, we identified all procedures complicated by infection (2.45%). Localized incisional pain and wound erythema were the most common presenting signs. Laboratory studies were performed in the majority of patients, but an imaging study was performed in less than half of these patients. The most common causative organism was Staphylococcus aureus and the IPG pocket was the most common site of an SCS-related infection. Explantation was ultimately performed in 52 of the 67 patients (77.6%). Non-explantation salvage therapy was attempted in 24 patients and was successful in resolving the infection in 15 patients without removal of SCS hardware components. DISCUSSION: This study provides current data regarding SCS related infections, including incidence, diagnosis, and treatment.


Asunto(s)
Contaminación de Equipos , Prótesis e Implantes/efectos adversos , Estimulación de la Médula Espinal/efectos adversos , Estimulación de la Médula Espinal/instrumentación , Infección de la Herida Quirúrgica/diagnóstico , Antibacterianos/uso terapéutico , Contaminación de Equipos/prevención & control , Femenino , Estudios de Seguimiento , Humanos , Prótesis e Implantes/microbiología , Estudios Retrospectivos , Infecciones Estafilocócicas/diagnóstico , Infecciones Estafilocócicas/epidemiología , Infecciones Estafilocócicas/terapia , Staphylococcus aureus/aislamiento & purificación , Infección de la Herida Quirúrgica/tratamiento farmacológico , Infección de la Herida Quirúrgica/epidemiología
2.
Neuromodulation ; 20(6): 558-562, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28493599

RESUMEN

OBJECTIVES: Spinal cord stimulation is an evidence-based treatment for a number of chronic pain conditions. While this therapy offers improvement in pain and function it is not without potential complications. These complications include device failure, migration, loss of therapeutic paresthesia, and infection. This article looked to establish a modern infection rate for spinal cord stimulators, assess the impact of known risk factors for surgical site infections and to determine the impact of certain preventative measures on the rate of infection. METHODS: After institutional review board approval, a multisite, retrospective review was conducted on 2737 unique implants or revisions of SCS systems. Patient demographics, risk factors including diabetes, tobacco use, obesity, revision surgery, trial length, implant location, implant type, surgeon background, prophylactic antibiotic use, utilization of a occlusive dressing, and post-operative antibiotic use were recorded and analyzed. RESULTS: The overall infection rate was 2.45% (n = 67). Diabetes, tobacco use, and obesity did not independently increase the rate of infection. Revision surgeries had a trend toward higher infection rate; however, this did not meet statistical significance. There was no difference in the rate of infection between implants performed by physicians of different base specialties, cylinder leads vs. paddle leads, or between different prophylactic antibiotics. Implants performed at academic centers had a higher rate of infection when compared to implants performed in nonacademic settings. When patients received an occlusive dressing or post-operative antibiotics they had a lower rate of infection. CONCLUSIONS: The infection rate (2.45%) reported in this study is lower than the previously reported rates (3-6%) and are on par with other surgical specialties. This study did not show an increased rate of infection for patients that used tobacco, had diabetes or were obese. It's possible that given the low overall infection rate a larger study is needed to establish the true impact of these factors on infection. In addition, this study did not address the impact of poorly controlled diabetes mellitus (elevated hemoglobin A1c) vs. well-controlled diabetes. It can be concluded from this study that utilizing an occlusive dressing over the incision in the post-operative period decreases the rate of infection and should become the standard of care. This study also demonstrated the positive impact of post-operative antibiotics in decreasing the rate of infection. Studies in other surgical specialties have not shown this impact which would suggest that further research is needed.


Asunto(s)
Electrodos Implantados/tendencias , Contaminación de Equipos , Estimulación de la Médula Espinal/tendencias , Infección de la Herida Quirúrgica/diagnóstico , Infección de la Herida Quirúrgica/etiología , Adulto , Anciano , Antibacterianos/uso terapéutico , Electrodos Implantados/efectos adversos , Electrodos Implantados/microbiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Estimulación de la Médula Espinal/efectos adversos , Estimulación de la Médula Espinal/instrumentación , Infección de la Herida Quirúrgica/tratamiento farmacológico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...