Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
2.
J Geriatr Cardiol ; 15(8): 519-522, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30344531

RESUMEN

BACKGROUND: Cardiovascular diseases and insufficient levels of vitamin D are risk factors for adverse surgical outcomes, and they are both commonly present among older adults undergoing orthopaedic surgery. Giving the cardiovascular effects of vitamin D, pre-operative diagnosis of hypovitaminosis D would be a valuable step for the implementation of supplementation protocols. We investigated if the normalization of serum 25 [OH] D could ameliorate cardiac performance of older adults suffering from cardiovascular diseases. METHODS: We enrolled 47 older adults scheduled for major orthopaedic surgery and suffering from hypovitaminosis D. Patients underwent 6-months calcifediol supplementation with a starting dose at first post-operative day of 50 µg/die in liquid preparation. Down-titration to 20 µg/die at 3-months assessment was planned. Cardiac performance was evaluated by measuring left ventricular ejection fraction (LVEF) and global longitudinal strain (GLS) during pre-operative assessments and at 1-month, 3-months, 6-months follow-ups. RESULTS: Six months of calcifediol supplementation were associated with a significant improvement of both LVEF (+ 3.94%; 95% CI: -4.0789 to -0.8232; P < 0.01) and GLS (+ 18.56%; Z = -5.895; P < 0.0001). CONCLUSIONS: Calcifediol supplementation normalized serum 25 [OH] D concentration after 1-month treatment. GLS offered better insights into myocardial contractile amelioration than LVEF, thus being useful for detecting earlier subclinical changes that may anticipate hemodynamic modifications.

3.
Hypertens Res ; 40(6): 573-580, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28077860

RESUMEN

During blood pressure (BP) measurement, the recommended positioning of the cuff bladder center is directly above the brachial artery. We investigated the relevance of incorrect cuff positioning during (1) auscultatory measurement with an appropriate or improperly small cuff and (2) oscillometric measurement with a wide-range cuff designed to guarantee accurate measurements regardless of position. In subjects with wide BP and arm circumference ranges, (1) auscultatory BP was repeatedly measured with a properly positioned cuff (reference) and, simultaneously, with an identical cuff placed on the other arm in either a correct or an incorrect position (test). The measurements were performed with a properly sized (N=57) or an improperly small cuff (N=33). (2) Auscultatory measurements obtained with a properly positioned and sized cuff were compared with oscillometric measurements obtained with a specially designed wide-range cuff (Omron IntelliWrap) placed on the contralateral arm either in a correct or an incorrect position. Auscultatory BP measures were unaffected by incorrect positioning of a properly sized cuff, whereas with undercuffing, BP was overestimated with the cuff displaced by 90° laterally (systolic/diastolic BP differences: 4.9±4.6/4.0±4.6 mm Hg, P<0.01) or by 180° (3.9±5.4/4.2±5.1 mm Hg, P<0.01) in relation to the correct position. Incorrect placement of the oscillometric cuff had no significant effect on the accuracy of the measurements (difference with correct position <1.5 mm Hg). Incorrect cuff positioning introduces a systematic overestimation of auscultatory BP when the cuff is too small in relation to arm circumference but not when it is correctly sized. No systematic error was observed with oscillometric measurements obtained with a specially designed wide-range cuff.


Asunto(s)
Determinación de la Presión Sanguínea/normas , Esfigmomanometros , Adulto , Anciano , Determinación de la Presión Sanguínea/instrumentación , Determinación de la Presión Sanguínea/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
5.
Psicol. USP ; 9(1): 185-186, 1998.
Artículo en Portugués | Index Psicología - Revistas | ID: psi-18976
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA