Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
J Endovasc Ther ; : 15266028241248600, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38708986

RESUMEN

PURPOSE: The primary aim of this study was to assess the 3-dimensional flare geometry of the Gore Viabahn VBX balloon-expandable covered stent (BECS) after fenestrated endovascular aortic repair (FEVAR) and to determine and visualize BECS-associated complications. METHODS: This multicenter retrospective study included patients who underwent FEVAR between 2018 and 2022 in 3 vascular centers participating in the VBX Expand Registry. Patients with at least one visceral artery treated with the VBX and with availability of 2 post-FEVAR computed tomography angiography (CTA) scans (follow-up [FU] 1: 0-6 months; FU2: 9-24 months) were included. The flare geometry of the VBX, including flare-to-fenestration distance, flare-to-fenestration diameter ratio, flare angle, and apposition with the target artery were assessed using a vascular workstation and dedicated CTA applied software. RESULTS: In total, 90 VBX BECS were analyzed in 43 FEVAR patients. The median CTA FU for FU1 and FU2 was 35 days (interquartile range [IQR], 29-51 days) and 14 months (IQR, 13-15 months), respectively. The mean flare-to-fenestration distance was 5.6±2.0 mm on FU1 and remained unchanged at 5.7±2.0 mm on FU2 (p=.417). The flare-to-fenestration diameter ratio was 1.19±0.17 on FU1 and remained unchanged at 1.21±0.19 (p=.206). The mean apposition length was 18.6±5.3 mm on FU1 and remained 18.6±5.3 mm (p=.550). The flare angle was 31°±15° on FU1 and changed to 33°±16° (p=.009). On FU1, the BECS-associated complication rate was 1%, and the BECS-associated reintervention rate was 0%. On FU2, the BECS-associated complication rate was 3%, and the BECS-associated reintervention rate was 1%. CONCLUSIONS: The flare geometry of the VBX bridging stent did not change significantly during 14 months follow-up in this study. Three-dimensional geometric analysis of the flare may contribute to identify the origin of endoleaks and occlusions, but this should be confirmed in a larger study including enough patients and BECS to compare complicated and uncomplicated cases. CLINICAL IMPACT: The three-dimensional flare geometry of the Gore Viabahn VBX BECS was assessed on the first and second postoperative CTA scans, and geometrical changes during this period were identified. For BECS that were diagnosed with a type 3c endoleak or occlusion, the BECS geometry was analyzed to detect geometrical components that were related to the complication. Geometric analysis of the flare may help to better detect and identify the cause of such complications.

2.
World J Surg ; 48(3): 758-766, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38323728

RESUMEN

BACKGROUND: Currently, the type of patch used for carotid endarterectomy closure depends on the preference of the operating surgeon. Various materials are available, including autologous venous patches, bovine pericardial patches (BPP), and synthetic patches. The purpose of this study was to compare the long-term outcomes. METHODS: All patients who underwent primary carotid endarterectomy with patch angioplasty using a venous, bovine, or polyester patch between 2010 and 2020 at two high-volume medical centers were included in this retrospective analysis on largely prospectively collected data. Study endpoints included long-term ipsilateral transient ischemic attack or cerebrovascular accident, restenosis, reintervention, and all-cause mortality. Cox proportional hazard models were fitted to assess the effect of patch type to each outcome. RESULTS: In total, 1481 CEAs were performed with a follow-up of 32 (13-65) months. Venous patch was used in 309 patients (20.9%), BPP in 1000 patients (67.5%), and polyester patch in 172 patients (11.6%). A preoperative symptomatic carotid artery stenosis of >50% was observed in 91.9% (n = 284) of the patients who received a venous patch, 92.1% (n = 921) of the patients who received BPP, and 90.7% (n = 156) of the patients who received a polyester patch (p = 0.799). Only in selected patients with an asymptomatic stenosis of >70% surgery was considered. Multivariable analyses showed no significant differences between the three patch types regarding long-term outcomes after adjusting for confounders. CONCLUSIONS: In patients undergoing primary carotid endarterectomy, the use of venous, bovine pericardial, or polyester patches seems equally safe and durable in terms of comparability in long-term outcomes.


Asunto(s)
Estenosis Carotídea , Endarterectomía Carotidea , Accidente Cerebrovascular , Humanos , Bovinos , Animales , Endarterectomía Carotidea/efectos adversos , Poliésteres , Estudios Retrospectivos , Resultado del Tratamiento , Estenosis Carotídea/cirugía , Accidente Cerebrovascular/etiología , Recurrencia
4.
Eur J Nucl Med Mol Imaging ; 50(13): 3880-3889, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37507493

RESUMEN

PURPOSE: 18F-fluoro-D-deoxyglucose positron emission tomography with low dose and/or contrast enhanced computed tomography ([18F]FDG-PET/CT) scan reveals high sensitivity for the diagnosis of vascular graft and endograft infection (VGEI), but lower specificity. Reporting [18F]FDG-PET/CT scans of suspected VGEI is challenging, reader dependent, and reporting standards are lacking. The aim of this study was to evaluate variability of [18F]FDG-PET/low dose CT (LDCT) reporting of suspected VGEI using a proposed standard reporting format. METHODS: A retrospective cohort study was conducted including all patients with a suspected VGEI (according to the MAGIC criteria) without need for urgent surgical treatment who underwent an additional [18F]FDG-PET/LDCT scan between 2006 and 2022 at a tertiary referral centre. All [18F]FDG-PET/LDCT reports were scored following pre-selected criteria that were formulated based on literature and experts in the field. The aim was to investigate the completeness of [18F]FDG-PET/LDCT reports for diagnosing VGEI (proven according to the MAGIC criteria) and to evaluate if incompleteness of reports influenced the diagnostic accuracy. RESULTS: Hundred-fifty-two patients were included. Median diagnostic interval from the index vascular surgical procedure until [18F]FDG-PET/LDCT scan was 35.5 (7.3-73.3) months. Grafts were in 65.1% located centrally and 34.9% peripherally. Based on the pre-selected reporting criteria, 45.7% of the reports included all items. The least frequently assessed criterion was FDG-uptake pattern (40.6%). Overall, [18F]FDG-PET/LDCT showed a sensitivity of 91%, a specificity of 72%, and an accuracy of 88% when compared to the gold standard (diagnosed VGEI). Lower sensitivity and specificity in reports including ≤ 8 criteria compared to completely evaluated reports were found (83% and 50% vs. 92% and 77%, respectively). CONCLUSION: Less than half of the [18F]FDG-PET/LDCT reports of suspected VGEI met all pre-selected criteria. Incompleteness of reports led to lower sensitivity and specificity. Implementing a recommendation with specific criteria for VGEI reporting is needed in the VGEI-guideline update. This study provides a first recommendation for a concise and complete [18F]FDG-PET/LDCT report in patients with suspected VGEI.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Enfermedades Vasculares , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Fluorodesoxiglucosa F18 , Estudios Retrospectivos , Tomografía de Emisión de Positrones , Tomografía Computarizada por Rayos X , Sensibilidad y Especificidad , Radiofármacos
5.
J Cardiovasc Surg (Torino) ; 64(6): 634-644, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37306682

RESUMEN

BACKGROUND: Evidence regarding the outcomes of Omniflow® II prosthesis in peripheral arterial revascularization at different anatomical sites and for different indications is scarce. Therefore, the aim of this study was to evaluate the outcomes of the Omniflow® II used at various positions within the femoral tract both in infected and non-infected setting. METHODS: Patients who underwent reconstructive lower leg vascular surgery with implantation of an Omniflow® II from 2014 until 2021 at five medical centers were retrospectively included (N.=142). Patients were subdivided into the following categories: femoro-femoral crossover (N.=19), femoral interposition (N.=18), femoro-popliteal (above-the-knee [N.=25; AK] or below-the-knee [N.=47; BK]), and femoro-crural bypass grafts (N.=33). Primary outcome was primary patency and secondary outcomes included primary assisted patency, secondary patency, major amputation, vascular graft infection, and mortality. Outcomes were compared according to different subgroups and the surgical setting (infected versus non-infected). RESULTS: The median follow-up was 35.0 (17.5-54.3) months. Three years primary patency of 58% was observed for femoro-femoral crossover bypass, 75% for femoral interposition graft, 44% for femoro-popliteal above-the-knee bypass, 42% for femoro-popliteal below-the-knee bypass, and 27% in the femoro-crural position (P=0.006). Freedom from major amputation at three years were 84% for femoro-femoral crossover bypass, 88% for femoral interposition bypass, 90% for femoro-popliteal AK bypass, 83% for femoro-popliteal BK bypass, and 50% for femoro-crural bypass (P<0.001). CONCLUSIONS: This study demonstrates the safety and feasibility of the use of Omniflow® II for femoro-femoral crossover-, femoral interposition-, and femoro-popliteal (AK and BK) bypass. Omniflow® II seems to be less suitable for femoro-crural bypass with a significantly lower patency compared to other positions.


Asunto(s)
Implantación de Prótesis Vascular , Arteria Poplítea , Humanos , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/cirugía , Implantación de Prótesis Vascular/efectos adversos , Estudios Retrospectivos , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Prótesis Vascular , Grado de Desobstrucción Vascular , Resultado del Tratamiento
6.
Ann Vasc Surg ; 95: 116-124, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37295670

RESUMEN

BACKGROUND: Vascular graft and endograft infections (VGEI) and native vessel infections (NVI) remain considerable challenges in vascular surgery, leading to high mortality and morbidity rates. Although in situ reconstruction is the preferred treatment, the material of choice is still a source of debate. Autologous veins are considered the first choice; however, xenografts may be an acceptable alternative. The performance of a biomodified bovine pericardial graft is assessed when implemented in an infected vascular area. METHODS: This is a prospective multicenter cohort study. Patients who underwent reconstruction for VGEI or NVI with a biomodified bovine pericardial bifurcated or straight tube graft were included from December 2017 until June 2021. The primary outcome measure was reinfection at mid-term follow-up. Secondary outcome measures included mortality, patency, and amputation rate. RESULTS: Thirty-four patients with vascular infections were included, of which 23 (68%) had an infected Dacron prosthesis after primary open repair and 8 (24%) had an infected endovascular graft. The remaining 3 (9%) had infected native vessels. At secondary repair, 3 (7%) patients had an in situ aortic tube reconstruction, 29 (66%) had an aortic bifurcated reconstruction, and 2 (5%) had an iliac-femoral reconstruction. At 1-year follow-up after the BioIntegral bovine pericardial graft reconstruction, the reinfection rate was 9%. The 1-year infection-related and procedure-related mortality rate was 16%. The occlusion rate was 6% and in total 3 patients underwent a lower limb amputation during the 1-year follow-up period. CONCLUSIONS: In situ reconstruction as treatment of (endo)graft and native vessel infections remains a challenge and reinfection looms as a potential consequence. In cases where time is of essence or when autologous venous repair is not feasible, a swift available solution is needed. The BioIntegral biomodified bovine pericardial graft may be an option as it shows reasonable results in terms of reinfection, in aortic tube and bifurcated grafts.


Asunto(s)
Implantación de Prótesis Vascular , Infecciones Relacionadas con Prótesis , Enfermedades Vasculares , Humanos , Bovinos , Animales , Prótesis Vascular/efectos adversos , Estudios de Cohortes , Reinfección , Estudios Prospectivos , Resultado del Tratamiento , Enfermedades Vasculares/cirugía , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/cirugía , Estudios Retrospectivos , Reoperación
7.
Diagnostics (Basel) ; 13(10)2023 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-37238153

RESUMEN

Inflammatory abdominal aortic aneurysms (iAAA) are a form of noninfectious aortitis in patients with abdominal aortic aneurysms (AAA). Ultrasound could help to detect iAAA early. This retrospective observational study assessed the potential of using ultrasound to detect iAAA in a case series of iAAA patients, and the diagnostic value of ultrasound to detect iAAA in consecutive patients in a follow-up for AAA, referred to as a feasibility study. In both studies, diagnosis of iAAA was based on a cuff surrounding the aneurysm using CT (golden standard). The case series included 13 patients (age 64 (61; 72) years; 100% male). The feasibility study included 157 patients (age 75 (67; 80) years; 84% male). In the case series, all iAAA patients showed a cuff surrounding the aortic wall on ultrasound. In the feasibility study with AAA patients, ultrasound yielded no cuff in 147 (93.6%; CT negative in all cases), a typic cuff in 8 (5.1%; CT positive in all cases), and an inconclusive cuff in 2 (1.3%; CT negative in both cases) patients. Sensitivity and specificity were 100% and 98.7%, respectively. This study indicates that iAAA can be identified with ultrasound, and safely ruled out. In positive ultrasound cases, additional CT imaging might still be warranted.

8.
Ann Vasc Surg ; 97: 410-418, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37244480

RESUMEN

BACKGROUND: Vascular graft/endograft infection is a rare but life-threatening complication of cardiovascular surgery and remains a surgical challenge. Several different graft materials are available for the treatment of vascular graft/endograft infection, each having its own advantages and disadvantages. Biosynthetic vascular grafts have shown low reinfection rates and could be a potential second best after autologous veins in the treatment of vascular graft/endograft infection. Therefore, the aim of our study was to evaluate the efficacy and morbidity of Omniflow® II for the treatment of vascular graft/endograft infection. METHODS: A multicenter retrospective cohort study was performed to evaluate the use of Omniflow® II in the abdominal and peripheral region to treat vascular graft/endograft infection between January 2014 and December 2021. Primary outcome was recurrent vascular graft infection. Secondary outcomes included primary patency, primary assisted patency, secondary patency, all-cause mortality, and major amputation. RESULTS: Fifty-two patients were included with a median follow-up duration of 26.5 (10.8-54.8) months. Nine (17%) grafts were implanted in intracavitary position and 43 (83%) in peripheral position. Most grafts were used as femoral interposition (n = 12, 23%), femoro-femoral crossover (n = 10, 19%), femoro-popliteal (n = 8, 15%), and aorto-bifemoral (n = 8, 15%) graft. Fifteen (29%) grafts were implanted extra-anatomically and 37 (71%) in situ. Eight patients (15%) presented with reinfection during follow-up, most of these patients received an aorto-bifemoral graft (n = 3, 38%). Intracavitary vascular grafting had a 33% (n = 3) reinfection rate and peripheral grafting 12% (n = 5; P = 0.025). The estimated primary patencies at 1, 2, and 3 years were 75%, 72%, and 72% for peripherally located grafts and 58% (at all timepoints) for intracavitary grafts (P = 0.815). Secondary patencies at 1, 2, and 3 years were 77% (at all timepoints) for peripherally located prostheses and 75% (at all timepoints) for intracavitary prostheses (P = 0.731). A significantly higher mortality during follow-up was observed in patients who received an intracavitary graft compared to patients with a peripheral graft (P = 0.003). CONCLUSIONS: This study highlights the efficacy and safety of the Omniflow® II biosynthetic prosthesis for the treatment of vascular graft/endograft infection, in absence of suitable venous material, with acceptable reinfection, patency, and freedom of amputation prevalences, especially in replacing peripheral vascular graft/endograft infection. However, a control group with either venous reconstruction or another alternative graft is needed to make firmer conclusions.


Asunto(s)
Implantación de Prótesis Vascular , Infecciones Relacionadas con Prótesis , Enfermedades Vasculares , Humanos , Implantación de Prótesis Vascular/efectos adversos , Reinfección , Estudios Retrospectivos , Resultado del Tratamiento , Prótesis Vascular/efectos adversos , Enfermedades Vasculares/cirugía , Infecciones Relacionadas con Prótesis/cirugía , Grado de Desobstrucción Vascular
9.
Vasc Endovascular Surg ; 57(6): 555-563, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36802836

RESUMEN

OBJECTIVES: Fenestrated endovascular repair (FEVAR) has become a widely used treatment option for complex abdominal aortic aneurysms (AAA) but long-term survival and quality of life (QoL) outcomes are scarce. This single center cohort study aims to evaluate both long-term survival and QoL after FEVAR. METHODS: All juxtarenal and suprarenal AAA patients treated with FEVAR in a single-center between 2002 and 2016 were included. QoL scores, measured by the RAND 36-Item Short Form Survey (SF-36), were compared with baseline data of the SF-36 provided by RAND. RESULTS: A total of 172 patients were included at a median follow-up of 5.9 years (IQR 3.0-8.8). Follow-up at 5 and 10 years post-FEVAR yielded survival rates of 59.9% and 18%, respectively. Younger patient age at surgery had a positive influence on 10-year survival and most patients died due to cardiovascular pathology. Emotional well-being was better in the research group as compared to baseline RAND SF-36 1.0 data (79.2 ± 12.4 vs 70.4 ± 22.0; P < 0.001). Physical functioning (50 (IQR 30-85) vs 70.6 ± 27.4; P = 0.007) and health change (51.6 ± 17.0 vs 59.1 ± 23.1; P = 0.020) were worse in the research group as compared to reference values. CONCLUSIONS: Long-term survival was 60% at 5-years follow-up, which is lower than reported in recent literature. An adjusted positive influence of younger age at surgery was found on long-term survival. This could have consequences for future treatment indication in complex AAA surgery but further large-scale validation is necessary.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Calidad de Vida , Stents , Estudios de Cohortes , Factores de Riesgo , Resultado del Tratamiento , Complicaciones Posoperatorias , Estudios Retrospectivos , Procedimientos Endovasculares/efectos adversos , Diseño de Prótesis , Factores de Tiempo , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía
10.
Biology (Basel) ; 12(2)2023 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-36829528

RESUMEN

Vascular graft and endograft infections (VGEI) cause a serious morbidity and mortality burden. 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) imaging is frequently used in the diagnostic workup, but the additional value of abnormal (18F-FDG active and/or enlarged) locoregional lymph nodes is unknown. In this retrospective study, the additional diagnostic value of abnormal locoregional lymph nodes on 18F-FDG PET/CT imaging for VGEI was evaluated, including 54 patients with a culture-proven VGEI (defined according to the Management of Aortic Graft Infection [MAGIC] group classification) and 25 patients without VGEI. 18F-FDG PET/CT was qualitatively and quantitatively assessed for tracer uptake and pattern at the location of the vascular graft, and locoregional lymph node uptake and enlargement (>10 mm). 18F-FDG uptake intensity and pattern independently predicted the presence of VGEI by logistic regression (Χ2: 46.19, p < 0.001), with an OR of 7.38 (95% CI [1.65, 32.92], p = 0.009) and 18.32 (95% CI [3.95, 84.88], p < 0.001), respectively. Single visual assessment of abnormal locoregional lymph nodes predicted the presence of VGEI with a sensitivity of 35%, specificity of 96%, PPV of 95%, and NPV of 41%. The visual assessment of abnormal lymph nodes after qualitative assessment of 18F-FDG uptake intensity and pattern at the vascular graft location did not independently predict the presence of VGEI by logistic regression (Χ2: 3.60, p = 0.058; OR: 8.25, 95% CI [0.74, 63.37], p = 0.096). In conclusion, detection of abnormal locoregional lymph nodes on 18F-FDG PET/CT has a high specificity (96%) and PPV (95%) for VGEI. However, it did not add to currently used 18F-FDG PET/CT interpretation criteria.

11.
J Vasc Surg ; 77(2): 666-667, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36681492
12.
J Vasc Surg ; 77(2): 559-566.e1, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36208708

RESUMEN

OBJECTIVE: Patch angioplasty during carotid endarterectomy (CEA) is commonly used to treat carotid artery stenosis. However, the choice of which patch to use remains a matter of debate. Autologous venous material has disadvantages such as wound-related problems at the harvest site and a prolonged intervention time. These limitations can be bypassed when synthetic or biological patches are used. Both materials have been associated with divergent advantages and disadvantages. Therefore, the aim of our study was to compare the long-term follow-up outcomes in patients who underwent CEA and closure with either a bovine pericardial patch (BPP) or polyester patch. METHODS: A retrospective cohort study was conducted including all patients who underwent primary CEA and closure with a BPP or a polyester patch between January 2010 and December 2020 at our tertiary referral center. In 2015, the BPP was introduced as an alternative for polyester. The primary outcome was the occurrence of transient ischemic attack (TIA) or cerebrovascular accident (CVA) during follow-up and secondary outcomes included restenosis, reintervention, all-cause mortality, and patch infection. Cox proportional hazard models were used and hazard ratios with 95% confidence intervals were used to predict these outcomes. RESULTS: We included 417 CEA patients; 254 patients (61%) received a BPP and 163 received (39%) a polyester patch. The mean age was 70.2 ± 8.7 years and 67% were male. The median follow-up time was 15 months (range, 12-27 months) for BPP and 42 months (range, 16-60 months) for polyester (P < .001). Postoperative hematoma (≤30 days) was significantly lower in the BPP cohort (2% BPP vs 6% polyester; P = .047). No other significant differences on short-term outcomes were found. Univariable Cox regression analyses showed no significant differences between the effect estimates of polyester and BPP on TIA or CVA (P = .106), restenosis (P = .211), reintervention (P = .549), or all-cause mortality (P = .158). No significant differences were found after adjusting for confounders in the multivariable analyses: TIA or CVA (P = .939), restenosis (P = .057), reintervention (P = .193) and all-cause mortality (P = .742). Three patients with a polyester patch had patch infection compared with none of the patients in the group who received a BPP. CONCLUSIONS: This large retrospective study showed comparable safety and durability of both BPP and polyester suggesting that both patch types can be safely applied for CEA with patch angioplasty. Patch infection was rare and was absent in the BPP group.


Asunto(s)
Estenosis Carotídea , Endarterectomía Carotidea , Ataque Isquémico Transitorio , Accidente Cerebrovascular , Humanos , Masculino , Bovinos , Animales , Persona de Mediana Edad , Anciano , Femenino , Endarterectomía Carotidea/efectos adversos , Estudios Retrospectivos , Ataque Isquémico Transitorio/etiología , Resultado del Tratamiento , Estenosis Carotídea/diagnóstico por imagen , Estenosis Carotídea/cirugía , Estenosis Carotídea/complicaciones , Accidente Cerebrovascular/etiología , Angioplastia/efectos adversos , Poliésteres , Recurrencia
13.
Int J Infect Dis ; 126: 22-27, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36375692

RESUMEN

A vascular graft or endograft infection (VGEI) is a severe complication that can occur after vascular graft or endograft surgery and is associated with high morbidity and mortality rates. A multidisciplinary approach, consisting of a team of vascular surgeons, infectious diseases specialists, medical microbiologists, radiologists, nuclear medicine specialists, and hospital pharmacists, is needed to adequately diagnose and treat VGEI. A structured diagnostic, antibiotic, and surgical treatment algorithm helps clinical decision making and ultimately aims to improve the clinical outcome of patients with a VGEI.


Asunto(s)
Implantación de Prótesis Vascular , Procedimientos Endovasculares , Infecciones Relacionadas con Prótesis , Enfermedades Vasculares , Injerto Vascular , Humanos , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/tratamiento farmacológico , Infecciones Relacionadas con Prótesis/cirugía , Procedimientos Endovasculares/efectos adversos , Enfermedades Vasculares/etiología , Resultado del Tratamiento
14.
EJVES Vasc Forum ; 55: 64-67, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35620416

RESUMEN

Introduction: Mycotic aortic aneurysm is defined as dilatation of the aortic wall due to infection caused by a variety of microorganisms and is associated with high mortality rates. This case report describes a patient with a rapid growing mycotic infrarenal aneurysm caused by Capnocytophaga canimorsus following a dog bite. Report: A 61 year old male professional dog handler presented with a history of progressive abdominal pain and constitutional symptoms. He had been bitten by a Pit Bull Terrier dog that was attacking a young girl three weeks prior to the onset of complaints. Investigations revealed a mycotic infrarenal aortic aneurysm that grew 0.5 cm in only three days. Open surgical repair consisting of an infrarenal aorto-aortic bypass with a 21 mm × 15 cm bovine bioprosthesis was performed successfully. All cultures and biopsies were negative and the subsequent 16S-23S rRNA intergenic spacer region based polymerase chain reaction (IS-pro) technique revealed C. canimorsus, a Gram negative bacterial pathogen that lives as a commensal in the gingival flora of dogs and cats that can cause a variety of severe infections, as the causative agent. Identification made it possible to treat the patient with eight weeks of intravenous followed by four weeks of oral antibiotics. At the last follow up over a year after surgery, the patient was symptom free, without infection and on ultrasound examination there were no signs of complications or aneurysm formation. Discussion: This case highlights C. canimorsus as a rare cause of a rapid growing mycotic aortic aneurysm following a dog bite. 16S-23S rRNA profiling (IS-pro) led to the identification of the bacterial pathogen. The use of biological grafts should be considered in the management of mycotic aortic aneurysms.

15.
Ann Vasc Surg ; 84: 225-238, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35104593

RESUMEN

BACKGROUND: The existing literature on mycotic aortic aneurysm is scarce and focuses on treatment. This study evaluates the clinical characteristics, diagnostics, treatment and outcome of patients with a mycotic abdominal aortic aneurysm treated in a tertiary referral center. METHODS: A retrospective cohort study was conducted including all patients with a proven mycotic abdominal aortic aneurysm admitted between May 2010 and July 2020. Primary outcome was mortality and secondary outcome included complications such as vascular graft/endograft infection. RESULTS: Twenty-four patients with a mycotic abdominal aortic aneurysm were included. Patients had a mean age of 68 ± 9 years and 20 (83%) were male. Thirteen patients (57%) had positive preoperative blood cultures. Streptococcus pneumoniae was most frequently isolated by blood culturing, pus, and vascular, or perivascular tissue cultures (17%). In 19 (83%) patients the mycotic abdominal aortic aneurysm was located infrarenally, in three (13%) patients suprarenally, and in one (4%) patient juxtarenally. Median follow-up was 20 (7-42) months. In 8 patients (33%) vascular graft and or endograft infection was diagnosed after surgical repair. Ten (42%) patients died during the follow-up period. The main causes of death were vascular graft/endograft infection-related (n = 4) and rupture of the mycotic abdominal aortic aneurysm (n = 3). No patient characteristics could be identified as predictive for mortality. CONCLUSIONS: This study shows a large variation in presentation, diagnostic approaches, and surgical and antibiotic treatment of mycotic abdominal aortic aneurysm. The detailed information about the diagnostic approaches to this rare disease and its antibiotic and/or other treatment contributes to existing knowledge of mycotic abdominal aortic aneurysm. Because of the individual variation patients should be discussed in a multidisciplinary team with a vascular surgeon, infectious disease specialist, and clinical microbiologist.


Asunto(s)
Aneurisma Infectado , Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Anciano , Aneurisma Infectado/diagnóstico por imagen , Aneurisma Infectado/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/etiología , Aneurisma de la Aorta Abdominal/cirugía , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
16.
Surg Technol Int ; 40: 249-256, 2022 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-35015899

RESUMEN

INTRODUCTION: Complex pathologies involving the aortic arch can be treated using the frozen elephant trunk (FET) technique, which is versatile and continues to be improved with different innovations to further reduce, for example, circulatory arrest time and the need for hypothermia. FET may or may not be a definitive repair, however. Distal extension or completion-especially endovascular-is common but not well described in the literature. This review describes the considerations that are necessary during FET planning and preparation, how pathology specifics and sizing decisions will affect the subsequent need for treatment, and how outcomes might be better reported to improve understanding of the advantages and limitations of the technique. MATERIALS AND METHODS: This literature review was performed to identify reports of second-stage endovascular completion after FET repair, and included any literature that described such interventions after index FET, for any aortic arch pathology. RESULTS: Secondary intervention after FET is an important parameter to establish the success or failure of the index procedure. However, unplanned extensions are often reported with insufficient detail and follow up, and studies rarely differentiate between unplanned or adjunctive procedures. In addition, prediction of the need for extension is complicated by the response of the pathology to the index procedure. CONCLUSION: FET is a versatile, established surgical technique that allows for several applications in different pathologies and innovative adaptations. How, when, and why FET is extended needs to be reported in greater detail, with specific consideration given to the interaction of FET and endovascular devices in sizing, integrity, and possible complications.


Asunto(s)
Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular , Procedimientos Endovasculares/métodos , Humanos , Estudios Retrospectivos , Resultado del Tratamiento
17.
Ann Transl Med ; 9(14): 1213, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34430654

RESUMEN

Carotid endarterectomy (CEA) with patch angioplasty is a widely used method for treating carotid artery stenosis. Patch infections are extremely rare, but the consequences may be serious. The current gold standard for treatment is patch excision and reconstruction with autologous material. However, no consensus has been reached and other options may be valuable as well in certain cases. The objective of this study was to evaluate the various treatment options for carotid patch infection after CEA with patch angioplasty on the basis of their outcomes (reinfection, ischemic stroke, and infection-related mortality). This systematic review was conducted in accordance with the PRISMA statement. The electronic bibliographic databases PubMed, Cochrane, and EMBASE were searched. Case series and case reports were included. Studies in languages other than English were excluded. Patients who developed a post-operative patch infection of CEA with patch angioplasty were included. Angioplasty could be performed with any type of patch. Patch infection needed to be confirmed by clinical presentation in combination with imaging, culture, or during the operation. The primary outcome measures were reinfection, ischemic stroke, and infection-related mortality. Eleven retrospective case series, two prospective case series, and seventeen case reports were included. The study size was 165 patients (mean age 69.7 years, M/F ratio 1.75:1). One hundred and seventy-one patches developed a patch infection after CEA with patch angioplasty and needed treatment. Treatment strategies included conservative treatment (14.0%), endovascular treatment (4.7%), and open surgery (81.4%). Mean follow-up was 34.8 months and extended up to 180 months. Reinfection rate was 4.7%, ischemic stroke rate 5.8%, and infection-related mortality rate 2.3%. No statistical comparison between treatment options could be performed, because of the heterogeneity of the included studies. Autologous material should be the primary choice of treatment if patch infection is diagnosed after CEA with patch angioplasty. In emergency situations, endovascular treatment, carotid ligation, or abscess drainage could be considered. Endovascular treatment and abscess drainage are temporary solutions. After the patient has recovered sufficiently, a more durable treatment i.e., open surgery is advised. Endo vacuum assisted closure (EndoVAC) seems to be promising. Further research is needed to determine the applicability of each treatment option.

18.
Ann Vasc Surg ; 77: e7-e13, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34454017

RESUMEN

The Mediterranean Federation for the Advancing of Vascular Surgery (MeFAVS) was founded in 2018, with the aim to promote cooperation among vascular professionals within Mediterranean countries. Due to its prominent social and economic impact on national health systems, diabetic peripheral artery was selected as the very first topic to be investigated by the federation. In this second paper, different experiences from delegates of participating countries were shared to define common strategies to harmonize, standardize, and optimize education and training in the Vascular Surgery specialty.


Asunto(s)
Angiopatías Diabéticas/cirugía , Educación de Postgrado en Medicina , Internado y Residencia , Enfermedad Arterial Periférica/cirugía , Cirujanos/educación , Procedimientos Quirúrgicos Vasculares/educación , Competencia Clínica , Curriculum , Angiopatías Diabéticas/diagnóstico , Angiopatías Diabéticas/epidemiología , Humanos , Curva de Aprendizaje , Región Mediterránea/epidemiología , Enfermedad Arterial Periférica/diagnóstico , Enfermedad Arterial Periférica/epidemiología , Evaluación de Programas y Proyectos de Salud , Especialización
20.
J Vasc Surg ; 72(6): 2174-2185.e2, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32645420

RESUMEN

OBJECTIVE: Vascular graft and endograft infection (VGEI) has high morbidity and mortality rates. Diagnosis is complicated because symptoms vary and can be nonspecific. A meta-analysis identified 18F-fluoro-d-deoxyglucose positron emission tomography-computed tomography (18F-FDG PET/CT) as the most valuable tool for diagnosis of VGEI and favorable to computed tomography as the current standard. However, the availability and varied use of several interpretation methods, without consensus on which interpretation method is best, complicate clinical use. The aim of this study was to evaluate the diagnostic performance of different interpretation methods of 18F-FDG PET/CT in diagnosis of VGEI. METHODS: A systematic review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Data sources included PubMed/MEDLINE, Embase, and Cochrane Library. A meta-analysis was conducted on the different interpretation methods for 18F-FDG PET/CT in diagnosis of VGEI, including visual FDG uptake intensity, visual FDG uptake pattern, and quantitative maximum standardized uptake (SUVmax). RESULTS: Of 613 articles, 13 were included (10 prospective and 3 retrospective articles). The FDG uptake pattern method (I2 = 26.2%) showed negligible heterogeneity, whereas the FDG uptake intensity (I2 = 42.2%) and SUVmax (I2 = 42.1%) methods showed moderate heterogeneity. The pooled sensitivity for FDG uptake intensity was 0.90 (95% confidence interval [CI], 0.79-0.96); for uptake pattern, 0.94 (95% CI, 0.89-0.97); and for SUVmax, 0.95 (95% CI, 0.76-0.99). The pooled specificity for FDG uptake intensity was 0.59 (95% CI, 0.38-0.78); for FDG uptake pattern, 0.81 (95% CI, 0.71-0.88); and for SUVmax, 0.77 (95% CI, 0.63-0.87). The uptake pattern interpretation method demonstrated the best positive and negative post-test probability, 82% and 10%, respectively. CONCLUSIONS: This meta-analysis identified the FDG uptake pattern as the most accurate assessment method of 18F-FDG PET/CT for diagnosis of VGEI. The optimal SUVmax cutoff, depending on the vendor, demonstrated strong sensitivity and moderate specificity.


Asunto(s)
Implantación de Prótesis Vascular/efectos adversos , Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Fluorodesoxiglucosa F18 , Tomografía Computarizada por Tomografía de Emisión de Positrones , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Radiofármacos , Implantación de Prótesis Vascular/instrumentación , Procedimientos Endovasculares/instrumentación , Humanos , Valor Predictivo de las Pruebas , Infecciones Relacionadas con Prótesis/etiología , Reproducibilidad de los Resultados , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...