Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Plant Dis ; 105(11): 3610-3622, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34743538

RESUMEN

Quantitative PCR (qPCR), loop-mediated amplification (LAMP), and lateral flow strip-based recombinase polymerase amplification (RPA-LFS) assays were assessed for early detection of Phytophthora infestans, the global causal agent of potato and tomato late blight, on passive wind-powered spore traps known as Spornados. Spore traps were deployed in potato and tomato fields during the 2018, 2019, and 2020 growing seasons in the provinces of Alberta, British Columbia, Manitoba, Prince Edward Island, and Ontario. All assays used DNA extracts from Spornado cassette membranes targeting the P. infestans nuclear ribosomal internal transcribed spacer. A total of 1,003 Spornado samples were qPCR tested, yielding 115 positive samples for P. infestans spores. In further assessment of these samples, LAMP detected P. infestans in 108 (93.9%) of 115 qPCR positive samples, and RPA-LFS detected it in 103 (89.6%). None of the assays showed cross-reaction with other Phytophthora species or pathogenic fungi known to infect potato and tomato. The qPCR detected ≤1 fg of P. infestans DNA, and LAMP and RPA-LFS amplified 10 fg in as little as 10 min. All assays detected P. infestans before the first report of late blight symptoms in commercial potato or tomato fields within each region or province. The combination of Spornado passive samplers with qPCR, LAMP, or RPA-LFS proved a valuable spore trapping system for early surveillance of late blight in potato and tomato. Both LAMP and RPA-LFS showed potential as alternative approaches to qPCR for in-field monitoring of P. infestans.


Asunto(s)
Phytophthora infestans , Solanum lycopersicum , Solanum tuberosum , Alberta , ADN , Phytophthora infestans/genética , Esporas , Viento
2.
J Dent Educ ; 77(9): 1122-8, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24002849

RESUMEN

MedEdPORTAL is a unique web-based peer-reviewed publication venue for clinical health educators sponsored by the Association of American Medical Colleges (AAMC). The open exchange of educational resources promotes professional collaboration across health professions. In 2008, the American Dental Education Association (ADEA) collaborated with AAMC to allow dental educators to use the platform to publish dental curriculum resources. Oral health is integral to general health; hence, collaboration among health care professionals brings enormous value to patient-centered care. The aim of this study was to conduct a current survey of metrics and submission statistics of MedEdPORTAL resources. The data were collected using the MedEdPORTAL search engine and ADEA and AAMC staff. The data collected were categorized and reported in tables and charts. Results showed that at the time of this study there were over 2,000 medical and dental resources available to anyone worldwide. Oral health resources constituted approximately 30 percent of the total resources, which included cross-indexing with information relevant to both medical and dental audiences. There were several types of dental resources available; the most common were the ones focusing on critical thinking. The usage of MedEdPORTAL has been growing, with participation from over 190 countries and 10,000 educational institutions around the world. The findings of this report suggest that MedEdPORTAL is succeeding in its aim to foster global collaborative education, professional education, and educational scholarship. As such, MedEdPORTAL is providing a new forum for collaboration and opens venues for promising future work in professional education.


Asunto(s)
Educación en Odontología , Docentes de Odontología , Educadores en Salud/educación , Recursos en Salud , Almacenamiento y Recuperación de la Información , Internet , Acceso a la Información , Humanos , Almacenamiento y Recuperación de la Información/métodos , Internacionalidad , Relaciones Interprofesionales , Revisión de la Investigación por Pares , Edición , Estados Unidos
3.
Simul Healthc ; 7(6): 329-33, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22902605

RESUMEN

SUMMARY STATEMENT: In September 2011, the Association of American Medical Colleges released the results of a survey conducted in 2010 on simulation activities at its member medical schools and teaching hospitals. In this commentary, we offer a synthesis of data and conclude that (1) simulation is used broadly at Association of American Medical Colleges member institutions, for many types of learners, including other health care professionals; (2) it addresses core training competencies and has many educational purposes; (3) its use in learner assessment is more prevalent at medical schools but is still significant at teaching hospitals; and (4) it requires a considerable investment of money, space, personnel, and time. These data confirm general perceptions about the state of simulation in North America for physician training. Future endeavors should include a more granular examination of how simulation is integrated into curricula, a similar survey of other health care-related institutions and professions, and a periodic assessment to characterize trends over time.


Asunto(s)
Competencia Clínica , Simulación por Computador/estadística & datos numéricos , Educación Médica/estadística & datos numéricos , Hospitales de Enseñanza/estadística & datos numéricos , Facultades de Medicina/estadística & datos numéricos , Canadá , Recolección de Datos , Educación Médica/métodos , Educación Médica/tendencias , Evaluación Educacional/métodos , Evaluación Educacional/estadística & datos numéricos , Hospitales de Enseñanza/métodos , Hospitales de Enseñanza/tendencias , Humanos , Facultades de Medicina/tendencias , Estados Unidos
4.
J Pediatr Orthop B ; 19(5): 441-5, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20389258

RESUMEN

Is the articular cartilage of the immature ankle joint damaged by tibial lengthening? Sixteen immature rabbits underwent a 30% diaphyseal lengthening by tibial callotasis. Damage was assessed by scanning electronic microscopy and histomorphometry at the completion of distraction and after an additional 5 weeks. Despite joint contracture, little damage in the articular cartilage was observed in contrast to the knee joint. The findings show that the immature ankle joint is more resilient to stress than the knee and implies that reduced weight bearing and decreased joint movement alone are not sufficient to cause cartilage damage, at least in the ankle.


Asunto(s)
Traumatismos del Tobillo/fisiopatología , Articulación del Tobillo/fisiopatología , Cartílago Articular/lesiones , Osteogénesis por Distracción/efectos adversos , Tibia/cirugía , Animales , Articulación del Tobillo/crecimiento & desarrollo , Cartílago Articular/patología , Cartílago Articular/ultraestructura , Masculino , Microscopía Electrónica de Rastreo , Modelos Animales , Conejos , Rodilla de Cuadrúpedos/crecimiento & desarrollo , Rodilla de Cuadrúpedos/lesiones , Rodilla de Cuadrúpedos/fisiopatología , Estrés Mecánico , Soporte de Peso
5.
J Pediatr Orthop B ; 16(6): 403-7, 2007 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17909337

RESUMEN

Limb lengthening by tibial callotasis is usually performed in the metaphysis but may cause growth inhibition. Is diaphyseal lengthening more advantageous? Sixteen immature rabbits underwent 30% diaphyseal lengthening by tibial callotasis. The tibial length was measured on radiographs at the end of the distraction period and after an additional 5 weeks. The proximal and distal growth plates were assessed histomorphometrically. Osteotomy stimulated tibial elongation; however, combined with diaphyseal lengthening the stimulation was suppressed resulting in longitudinal growth that matched the control side. In longer lengthenings of limbs diaphyseal callotasis may be more advantageous than metaphyseal by not inhibiting longitudinal growth.


Asunto(s)
Alargamiento Óseo/métodos , Diáfisis/cirugía , Tibia/cirugía , Animales , Callo Óseo/diagnóstico por imagen , Callo Óseo/crecimiento & desarrollo , Callo Óseo/cirugía , Diáfisis/diagnóstico por imagen , Diáfisis/patología , Modelos Animales de Enfermedad , Placa de Crecimiento/crecimiento & desarrollo , Placa de Crecimiento/patología , Placa de Crecimiento/cirugía , Masculino , Osteogénesis por Distracción , Osteotomía , Conejos , Radiografía , Tibia/diagnóstico por imagen , Tibia/crecimiento & desarrollo
6.
J Pediatr Orthop B ; 16(5): 305-11, 2007 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17762667

RESUMEN

Bone-screw loosening in monolateral external fixators is a significant problem. This study classifies the radiographic appearance of the bone-screw interface and predicts which screws will become loose and those that will remain solidly fixed to bone. Five radiographic features were identified at the bone-screw interface. The classification of these features was validated using interobserver and intraobserver studies. The reliability of the classification was improved by image enhancement with simple filters. Some radiographic features predicted which screws would eventually become loose, allowing the clinician to make earlier management decisions regarding the adjustment of screws.


Asunto(s)
Tornillos Óseos , Fijadores Externos , Técnica de Ilizarov/instrumentación , Pediatría/métodos , Falla de Prótesis , Tibia/diagnóstico por imagen , Tibia/cirugía , Niño , Femenino , Humanos , Masculino , Variaciones Dependientes del Observador , Complicaciones Posoperatorias/diagnóstico por imagen , Radiografía , Estudios Retrospectivos
7.
J Pediatr Orthop B ; 16(3): 233-5, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17414790

RESUMEN

The Vilarrubias method of limb lengthening is a percutaneous procedure with soft tissue releases. This reduces soft tissue tension and prevents joint contractures during longer lengthenings. This method has been used for 99 lower limb lengthenings. The mean length gained was 92 mm and the mean Bone Healing Index was 41.3 days/cm. There were 45 pin site problems, 33 flexion contractures, 33 angular deformities and 15 stress fractures. This complication rate compares well with other techniques. We recommend that the Vilarrubias method can be considered for lengthenings, where the aim is greater than 15% of the bone length with potential soft tissue problems.


Asunto(s)
Fémur/cirugía , Peroné/cirugía , Osteogénesis por Distracción/métodos , Tibia/cirugía , Adolescente , Adulto , Niño , Preescolar , Femenino , Humanos , Masculino
8.
J Orthop Res ; 24(11): 2080-6, 2006 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-16944472

RESUMEN

We studied the influence of different parameters of bone quality on the fixation strength of bicondylar tibial plateau fractures and examined the relationship between these parameters. Bone quality was measured in the plateau of 16 cadaveric tibias using three modalities: dual-energy X-ray absorptiometry (DXA), peripheral quantitative computer tomography (pQCT), and spectral analysis of digitized radiographs (SADR). The tibias were divided into two groups by the median bone mineral density (BMD) and randomized to receive either dual plating or external fixator for the stabilization of a standardized bicondylar tibial fracture. The fixed fractures were subjected to axial compression until failure. DXA BMD correlated most significantly with the failure load (r>or=0.79, p<0.001), followed by the pQCT parameters of cancellous bone (0.52>or=r>or=0.73, p<0.01). Similar strong correlations were also evident in both fixation methods. For parameters derived from SADR, only those including both longitudinal and transverse trabecular orientations had modest correlation with the fixation strength (0.53>or=r>or=0.71, p<0.01). The failure loads of the two fixation techniques were not significantly different (mean+/-SD=3522+/-1386 N and 3710+/-1356 N, respectively, p=0.78). However, BMD in the dual-plating group influenced the failure load significantly (p=0.03), whereas in the external fixation group this was less evident (p=0.100). The majority of bone quality parameters that correlated with fixation strength were also strongly correlated with each other, particularly the BMDs measured by DXA and pQCT. This is the first study that relates fixation strength of bicondylar tibial plateau fractures to bone quality assessed at the same anatomical site. BMD around the fracture site had the best correlation with the failure load regardless of the fixation technique. The two fixation methods tested performed equally well, and the choice between them depends on the soft tissue condition and surgeon preference.


Asunto(s)
Fijadores Externos , Fijación de Fractura/instrumentación , Fijadores Internos , Tibia/cirugía , Fracturas de la Tibia/cirugía , Fenómenos Biomecánicos , Densidad Ósea , Fuerza Compresiva , Humanos , Resistencia a la Tracción , Tibia/metabolismo , Tibia/fisiopatología , Fracturas de la Tibia/metabolismo , Fracturas de la Tibia/fisiopatología
9.
J Orthop Res ; 24(3): 339-47, 2006 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-16479566

RESUMEN

Successful limb lengthening requires serial radiological evaluation of the progression of healing of the regenerate bone. However, there is no radiographic classification system that shows how the regenerate should progress during treatment in adults. The study aimed to address this need.A series of radiographs were studied from 92 patients (125 segments) who had undergone bone lengthening. A radiographic classification of osteogenesis was developed based on callus shape and radiographic features that occur between osteotomy and fixator removal. This classification system used both shape and type of feature to condense and record the radiographic information, but type of feature alone was sufficient to predict outcome. The concurrence and reproducibility of the classification system was tested by inter- and intra-observer studies. The degree of consistent repetition and agreement between observers suggests that the classification system is reliable, reproducible, and therefore should be robust in use. This classification system provides an insight into osteogenesis; it allows the progress of the bone healing to be assessed against a successful pattern of healing. Hence, potential problems can be predicted and clinical changes made to improve outcome. The classification can be simplified to make it more appropriate for clinical use.


Asunto(s)
Callo Óseo , Fémur/fisiología , Osteogénesis por Distracción/clasificación , Tibia/fisiología , Adolescente , Adulto , Callo Óseo/diagnóstico por imagen , Fémur/diagnóstico por imagen , Fémur/cirugía , Humanos , Persona de Mediana Edad , Radiografía , Reproducibilidad de los Resultados , Tibia/diagnóstico por imagen , Tibia/cirugía
10.
J Biomech ; 39(3): 544-50, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16389095

RESUMEN

Hybrid external fixators have become more popular over recent years, and although biomechanical tests show varying results from paper to paper, a consistent finding is shear motion occurring at the fracture/osteotomy site during loading. This can be reduced to some extent by frame configuration, and with the use of olive stop wires, but both of these have limitations. We have investigated the use of threaded fine wires in a circular hybrid fixator. A reliable tensioning method is described which minimises movement at the wire-bone interface during tensioning, and threaded wires are seen to offer a significant improvement in fracture site shear stiffness when compared to smooth fine wires.


Asunto(s)
Hilos Ortopédicos , Fijadores Externos , Animales , Fenómenos Biomecánicos , Porcinos
11.
J Biomech ; 39(7): 1355-60, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-15936763

RESUMEN

Although adequate reduction and stable fixation have been recognized to be the prime goals in the treatment of displaced tibial plateau fractures, the optimal fixation technique remains controversial. The lack of a reliable model and a standard methodology contribute to this situation. The purpose of this study is to develop an experimental model of a tibial plateau fracture and a testing methodology that reproduces the failure mode commonly seen in the clinical setting. Using solid-foam and composite Sawbones tibiae, three different models of bi-condylar tibial plateau fracture (solid-foam, reinforced solid-foam and composite), six specimens for each model, were created and stabilized with double plating. The specimens were subjected to cyclic axial compression with increasing maximum load until failure. A femoral component of a total knee replacement of similar size and shape to the synthetic tibial surface was used as a load applicator. The experiment was repeated on six specimens of human cadaver tibiae. Among the Sawbones specimens, only the reinforced solid-foam model was found to produce a consistent failure mode (collapse in the medial plateau) comparable to that reported clinically in the literature. This mode of failure was also confirmed by the cadaver experiments. The failure load of the reinforced solid-foam model ranged from 4150 to 4260 N with a mean +/- SD of 4201 +/- 44 N and a coefficient of variance of 0.01, whereas for the cadaver model the failure load ranged from 1675 to 6096 N with a mean +/- SD of 3768 +/- 1482 N and a coefficient of variance of 0.39. We recommend the reinforced-foam model for future mechanical tests to compare different fixation methods for tibial plateau fractures.


Asunto(s)
Fenómenos Biomecánicos/métodos , Articulación de la Rodilla/fisiopatología , Modelos Biológicos , Tibia/fisiopatología , Fracturas de la Tibia/fisiopatología , Simulación por Computador , Elasticidad , Humanos , Estrés Mecánico
12.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-544839

RESUMEN

[Objective]To evaluated the distraction-resisting force contributed by gastrocnemius during tibial lengthening.The force contributed by gastrocnemius during both the distraction and consolidation phases in a rabbit model of tibial lengthening were measured by an in-line strain gauged bilateral fixator.[Method]Sixteen immature New Zealand White rabbits underwent 30% (left) tibial diaphyseal lengthening at a rate of two 0.4 mm increments per day.[Result]The contribution of the gastrocnemius distraction-resisting force at the end of lengthening (11?5N,25%?7%) was statistically higher than that of 5 weeks later (3?1 N,13%?5%)(P

13.
Foot Ankle Int ; 26(3): 251-5, 2005 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15766430

RESUMEN

BACKGROUND: Both clinical and radiographic techniques have been used to evaluate foot and ankle position and orientation. Clinical measurements have been shown to be less reliable than radiographic measurements. Because midfoot equinus deformity may coexist with ankle joint equinus deformity, a radiographic method of separating and measuring these two components is desirable. The purpose of this study was to evaluate a new radiographic technique, the Lateral Mid-Tibia to Toes (LMTT), weightbearing view of the foot and ankle. METHOD: Twenty LMTT images were randomly selected from the study population of patients treated in our center for lower limb equinus deformity. Validation was achieved by a study involving three observers, assessing 20 images on two consecutive occasions, 4 weeks apart. Analysis was performed using Kappa statistics. RESULTS: The plantigrade and midfoot equinus angles provided substantial (p = 0.000) and moderate (p = 0.005) agreement, respectively. CONCLUSIONS: Awareness of midfoot equinus and its correction may avoid residual deformity when surgery is performed to correct equinus deformity of the ankle.


Asunto(s)
Tobillo/diagnóstico por imagen , Deformidades del Pie/diagnóstico por imagen , Pie/diagnóstico por imagen , Humanos , Radiografía , Valores de Referencia , Reproducibilidad de los Resultados , Soporte de Peso
14.
Clin Biomech (Bristol, Avon) ; 20(1): 91-6, 2005 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-15567542

RESUMEN

BACKGROUND: Although clear differences in fracture site displacement have previously been demonstrated between transverse and oblique fracture models stabilised by an asymmetrical method, the direction of the obliquity has not been examined biomechanically. METHODS: Eight Sawbones tibiae were cut to represent oblique fractures: four ran from antero-inferior to postero-superior and four from antero-superior to postero-inferior. These were fixed with a Sheffield Ring Fixator and cyclically loaded in axial and off-axis compression. Direct measurements were taken of inter-fragmentary displacement. RESULTS: Significant differences were detected between the fracture directions (P < 0.01) and inter-fragmentary displacements were generally reduced in antero-superior to postero-inferior fractures compared with antero-inferio to postero-superior fractures. INTERPRETATION: Fixation asymmetries need to be tailored to specific fracture orientation to improve fracture site mechanics.


Asunto(s)
Fijadores Externos , Fijación de Fractura/instrumentación , Fijación de Fractura/métodos , Movimiento , Fracturas de la Tibia/fisiopatología , Fracturas de la Tibia/cirugía , Soporte de Peso , Anisotropía , Humanos , Radiografía , Fracturas de la Tibia/diagnóstico por imagen , Resultado del Tratamiento
15.
Clin Biomech (Bristol, Avon) ; 19(7): 733-7, 2004 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-15288460

RESUMEN

BACKGROUND: Distraction-resisting force is generated in the soft tissues and callus during limb lengthening. Monitoring this force may offer a method of studying the behaviour of soft tissue and detecting the distraction osteogenesis related problems, and help to prevent complications. Changes in the post distraction period have not been previously investigated and there are no reports on the contribution of gastrocnemius to the distraction-resisting force. METHODS: Sixteen immature New Zealand White rabbits underwent 30% (left) tibial diaphyseal lengthening at a rate of two 0.4 mm increments per day. Using an instrumented bilateral fixator, the passive distraction-resisting force and the contribution made by gastrocnemius were measured at the end of lengthening and 5 weeks after lengthening. FINDINGS: The distraction-resisting force at the end of lengthening (mean 44 N (SD 10)) was statistically higher (p < 0.01) than that five weeks after lengthening (mean 20 N (SD 8)), so was the contribution of the gastrocnemius to the force (mean 11 N (SD 5 N) or 25% (SD 7) at the end of lengthening and 3 N (SD 1) or 13% (SD 5.2) five weeks later). INTERPRETATION: The callus rather than the surrounding muscles generates most of the passive DRF and its share of the force increased during consolidation period.


Asunto(s)
Alargamiento Óseo/métodos , Diáfisis/fisiología , Músculo Esquelético/fisiología , Tibia/fisiología , Animales , Diseño de Equipo , Conejos
16.
J Biomech ; 37(7): 1053-9, 2004 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-15165875

RESUMEN

The in vivo passive knee joint reaction force was measured in a rabbit model of tibial diaphyseal lengthening. This was based on the assumption that limb lengthening creates soft tissue tension that compresses the joint surface and generates the joint contact force. A measurement method was developed that involved the distraction of the joint and the determination of the distraction force that just separates the joint surfaces. Sixteen immature (mean+/-SD age=9+/-0.6 weeks) New Zealand White rabbits underwent 30% (left) tibial diaphyseal lengthening at a rate of two 0.4mm incremental lengthenings per day. The knee joint reaction force was measured at the end of lengthening (8 rabbits, mean+/-SD age=14+/-0.6 weeks) and five weeks after lengthening (8 rabbits, mean+/-SD age=19+/-0.7 weeks). An instrumented bilateral distractor and an extensometer were fixed cross the knee joint. The joint distraction force and distraction displacement were measured when the joint was distracted in steps and after the section of the Achilles tendon. The joint reaction force on the lengthened side was significantly higher than the control side at both time points (mean+/-SD 44.4+/-7.8 N v. 27.2+/-4.0 N at the end of lengthening, 44.3+/-S6.5 N v. 31.3+/-3.0 N at 5 weeks after lengthening). The contribution of the gastrocnemius to the joint reaction force on the lengthened side was also significantly higher than the control side at both time points (mean+/-SD 9.0+/-1.3N v. 2.8+/-0.8 N at the end of lengthening, 5.3+/-1.4N v. 2.7+/-0.5N at 5 weeks after lengthening). There were significant knee and ankle joint contractures at the end of lengthening, as evidenced by decreased range of motion (mean+/-SD 27+/-8 degrees and 36+/-13 degrees, respectively), which remained 5 weeks after lengthening (mean+/-SD 26+/-6 degrees and 35+/-8 degrees, respectively). The gastrocnemius contributed about 20% of the joint reaction force, indicating that changes in the other intra- and extra-articular structures due to joint contracture may be more important in generating the joint reaction force.


Asunto(s)
Diáfisis/fisiología , Articulación de la Rodilla/fisiología , Modelos Animales , Tibia/fisiología , Animales , Diáfisis/anatomía & histología , Conejos , Tibia/anatomía & histología
17.
Clin Orthop Relat Res ; (415): 193-201, 2003 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-14612646

RESUMEN

The authors evaluated the effect of the foot on the loading axis of the lower limb measured from radiographs in 30 pediatric patients. Deviation at the knee was calculated for the hip-ankle (traditional) and the hip-foot lines (heel lined up with a metal wire). A trigonometric model of the limb loading axis was developed with predicted mechanical axis deviations at the knee. Statistics were based on the methods of Bland and Altman. Mechanical axis deviation at the knee in the frontal plane varies with foot height, foot-tibial angle, and genu valgum. The predicted trigonometric model was found to be in agreement with measured radiographic values. Including the foot in the radiographic measurement of limb alignment may increase validity of surgical planning for correction of malalignment and for evaluation of degenerative arthritis risk at the knee level.


Asunto(s)
Antropometría/métodos , Desviación Ósea/diagnóstico por imagen , Pie/diagnóstico por imagen , Extremidad Inferior/diagnóstico por imagen , Modelos Biológicos , Adolescente , Factores de Edad , Sesgo , Fenómenos Biomecánicos , Estatura , Desviación Ósea/etiología , Desviación Ósea/fisiopatología , Niño , Femenino , Pie/fisiología , Humanos , Extremidad Inferior/fisiología , Masculino , Matemática , Valor Predictivo de las Pruebas , Radiografía , Rango del Movimiento Articular , Rotación , Soporte de Peso
18.
Clin Orthop Relat Res ; (415): 214-20, 2003 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-14612648

RESUMEN

Quadricepsplasty has been described by Thompson and Judet to improve flexion in severely ankylosed knees. Judet's technique has potential advantages because it is less damaging to the quadriceps mechanism and addresses the problem of external fixator pin site tethering on the lateral side of the thigh. The outcome of Judet's quadricepsplasty was assessed in 10 consecutive patients who were treated with external fixation either as a primary treatment (three patients) or as a secondary treatment for nonunion or malunion (seven patients) in a limb reconstruction unit. The patients were reviewed and examined at a minimal followup of 20 months. Their average prequadricepsplasty flexion of 33 degrees was improved to 105 degrees in the operating room and to 88 degrees on final review after an average followup of 24 months. According to Judet's criteria, there were one fair, seven good, and two excellent results. Two patients had postoperative complications, one hematoma and one infection. A minimal extension lag (10 degrees ) developed in one patient. Judet quadricepsplasty successfully increases flexion range with minimum impairment of quadriceps function. Familiarity with this technique might lower the surgeon's threshold for considering quadricepsplasty in patients with severe knee ankylosis after severe femoral fractures and in particular after a prolonged period of external fixation.


Asunto(s)
Anquilosis/cirugía , Contractura/cirugía , Disección/métodos , Articulación de la Rodilla , Recuperación del Miembro/métodos , Músculo Esquelético/cirugía , Rango del Movimiento Articular , Muslo , Adulto , Anquilosis/etiología , Anquilosis/fisiopatología , Contractura/etiología , Contractura/fisiopatología , Disección/efectos adversos , Fijadores Externos/efectos adversos , Fracturas del Fémur/complicaciones , Fracturas del Fémur/cirugía , Estudios de Seguimiento , Fracturas no Consolidadas/complicaciones , Fracturas no Consolidadas/cirugía , Hematoma/etiología , Humanos , Recuperación del Miembro/efectos adversos , Monitoreo Intraoperatorio , Terapia Pasiva Continua de Movimiento , Índice de Severidad de la Enfermedad , Infección de la Herida Quirúrgica/etiología , Resultado del Tratamiento
19.
Clin Biomech (Bristol, Avon) ; 18(9): 864-70, 2003 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-14527814

RESUMEN

OBJECTIVE: To compare the mechanical strength of fixation of bicondylar tibial plateau fractures using internal and external fixation techniques. DESIGN: A randomised laboratory testing of fixation methods currently in clinical use. BACKGROUND: To reduce the high complication rate associated with the double plating, many surgeons have started to use less invasive techniques. However the literature comparing the mechanical performance of these methods is still scarce. METHODS: Bicondylar tibial plateau fractures were simulated on Sawbones tibiae and fixed with one of the five fixation methods: dual plating, a two-ring hybrid fixator with inter-fragmentary screws, a ring-bar hybrid fixator with inter-fragmentary screws, lateral plate and medial monolateral external fixator, lateral plate and medial inter-fragmentary screws. Following statistical power calculations, seven tibiae were used for each fixation method. The specimens were tested in cyclical compression to failure. The vertical subsidence in the medial or lateral plateau was measured using extensometers. RESULTS: In all cases the mode of failure was consistent with collapse occurring in the medial plateau. There was no significant difference in the failure load between dual plating and the two-ring hybrid fixator (4218 N and 4184 N respectively; P=0.28, t-test). Failure was seen at significantly lower loads with the other fixation systems. CONCLUSION: Weight-bearing mobilisation of the patient may be undertaken earlier with more confidence by using the double plating or two-ring hybrid fixator rather than other less strong techniques. The choice on which of these two methods to use may depend on tissue viability and surgeon preference.


Asunto(s)
Análisis de Falla de Equipo/métodos , Fijación de Fractura/instrumentación , Dispositivos de Fijación Ortopédica , Tibia/fisiopatología , Tibia/cirugía , Fracturas de la Tibia/fisiopatología , Fracturas de la Tibia/cirugía , Fuerza Compresiva , Elasticidad , Humanos , Falla de Prótesis , Soporte de Peso
20.
J Bone Joint Surg Br ; 85(5): 691-9, 2003 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-12892192

RESUMEN

Fine-wire external fixation is accepted as a minimally invasive technique, which can provide better outcomes than traditional open methods in the management of complex fractures of the tibial plateau. Available fixators vary in their biomechanical stability, and we believe that a stable beam-loading system is essential for consistently good outcomes. We assessed, prospectively, the clinical, radiological and general health status of 20 of 21 consecutive patients with complex fractures of the tibial plateau who had been treated using a standard protocol, with percutaneous screw fixation and a neutralisation concept with a fine wire beam-loading fixator allowing early weight-bearing. Bony union was achieved in all patients, with 85% having good or excellent results. Full weight-bearing started during the first six weeks in 60% of patients. The general health status assessment correlated well with the knee scores and reflected a satisfactory outcome.


Asunto(s)
Fijadores Externos , Fijación de Fractura/instrumentación , Fracturas de la Tibia/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Densidad Ósea/fisiología , Femenino , Fijación de Fractura/métodos , Humanos , Masculino , Persona de Mediana Edad , Movimiento/fisiología , Complicaciones Posoperatorias/etiología , Estudios Prospectivos , Radiografía , Reoperación , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/fisiopatología , Resultado del Tratamiento , Soporte de Peso/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...