Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Anal Chem ; 2024 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-38862388

RESUMEN

The diversity of cannabinoid isomers and complexity of Cannabis products pose significant challenges for analytical methodologies. In this study, we developed a method to analyze 14 different cannabinoid isomers in diverse samples within milliseconds by leveraging the unique adduct-forming behavior of silver ions in advanced cyclic ion mobility spectrometry-mass spectrometry. The developed method achieved the separation of isomers from four groups of cannabinoids: Δ3-tetrahydrocannabinol (THC) (1), Δ8-THC (2), Δ9-THC (3), cannabidiol (CBD) (4), Δ8-iso-THC (5), and Δ(4)8-iso-THC (6) (all MW = 314); 9α-hydroxyhexahydrocannabinol (7), 9ß-hydroxyhexahydrocannabinol (8), and 8-hydroxy-iso-THC (9) (all MW = 332); tetrahydrocannabinolic acid (THCA) (10) and cannabidiolic acid (CBDA) (11) (both MW = 358); Δ8-tetrahydrocannabivarin (THCV) (12), Δ8-iso-THCV (13), and Δ9-THCV (14) (all MW = 286). Moreover, experimental and theoretical traveling wave collision cross section values in nitrogen (TWCCSN2) of cannabinoid-Ag(I) species were obtained for the first time with an average error between experimental and theoretical values of 2.6%. Furthermore, a workflow for the identification of cannabinoid isomers in Cannabis and Cannabis-derived samples was established based on three identification steps (m/z and isotope pattern of Ag(I) adducts, TWCCSN2, and MS/MS fragments). Afterward, calibration curves of three major cannabinoids were established with a linear range of 1-250 ng·ml-1 for Δ8-THC (2) (R2 = 0.9999), 0.1-25 ng·ml-1 for Δ9-THC (3) (R2 = 0.9987), and 0.04-10 ng·ml-1 for CBD (4) (R2 = 0.9986) as well as very low limits of detection (0.008-0.2 ng·ml-1). Finally, relative quantification of Δ8-THC (2), Δ9-THC (3), and CBD (4) in eight complex acid-treated CBD mixtures was achieved without chromatographic separation. The results showed good correspondence (R2 = 0.999) with those obtained by gas chromatography-flame ionization detection/mass spectrometry.

2.
Adv Food Nutr Res ; 110: 67-144, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38906592

RESUMEN

Natural toxins (NTs) are poisonous secondary metabolites produced by living organisms developed to ward off predators. Especially low molecular weight NTs (MW<∼1 kDa), such as mycotoxins, phycotoxins, and plant toxins, are considered an important and growing food safety concern. Therefore, accurate risk assessment of food and feed for the presence of NTs is crucial. Currently, the analysis of NTs is predominantly performed with targeted high pressure liquid chromatography tandem mass spectrometry (HPLC-MS/MS) methods. Although these methods are highly sensitive and accurate, they are relatively expensive and time-consuming, while unknown or unexpected NTs will be missed. To overcome this, novel on-site screening methods and non-targeted HPLC high resolution mass spectrometry (HRMS) methods have been developed. On-site screening methods can give non-specialists the possibility for broad "scanning" of potential geographical regions of interest, while also providing sensitive and specific analysis at the point-of-need. Non-targeted chromatography-HRMS methods can detect unexpected as well as unknown NTs and their metabolites in a lab-based approach. The aim of this chapter is to provide an insight in the recent advances, challenges, and perspectives in the field of NTs analysis both from the on-site and the laboratory perspective.


Asunto(s)
Contaminación de Alimentos , Toxinas Biológicas , Toxinas Biológicas/análisis , Contaminación de Alimentos/análisis , Cromatografía Líquida de Alta Presión/métodos , Espectrometría de Masas en Tándem/métodos , Humanos , Animales
3.
Anal Chim Acta ; 1285: 342000, 2024 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-38057054

RESUMEN

BACKGROUND: The increasing demand for food and feed products is stretching the capacity of the food value chain to its limits. A key step for ensuring food safety is checking for mycotoxin contamination of wheat. However, this analysis is typically performed by rather complex and expensive chromatographic methods, such as liquid chromatography-tandem mass spectrometry (LC-MS/MS). These costly methods require extensive sample preparation that is not easily carried out at different points along the food supply chain. To overcome such challenges in sample processing, an inexpensive and portable sample preparation device was needed, that required low skill, for rapid sample-to-result mycotoxin screening. RESULTS: We describe 3D-printed and interconnectable modules for simple, integrated and on-site sample preparation, including grinding of wheat kernels, and solvent-based extraction. We characterized these 3D-printed modules for mycotoxin screening and benchmarked them against a laboratory mill using commercial lateral flow device(s) (LFD) and in-house validated LC-MS/MS analysis. Different integrated sieve configurations were compared based on grinding efficiency, and we selected a sieve size of 2 mm allowing grinding of 10 g of wheat within 5 min. Moreover, 10 first time-users were able to operate the grinder module with minimal instructions. Screening for deoxynivalenol (DON) in naturally contaminated samples at the regulatory/legal limit (1.25 mg kg-1) was demonstrated using the developed 3D-printed prototype. The whole process only takes 15 min, from sample preparation to screening result. The results showed a clear correlation (R2 = 0.96) between the LFD and LC-MS/MS. SIGNIFICANCE: Our findings demonstrate the potential of 3D-printed sample handling equipment as a valuable extension of existing analytical procedures, facilitating the on-site implementation of rapid methods for the determination of mycotoxins in grains. The presented prototype is inexpensive with material costs of 2.5€, relies on biodegradable 3D printing filament and can be produced with consumer-grade printers, making the prototype readily available. As a future perspective, the modular character of our developed tool kit will allow for adaptation to other hard food commodities beyond the determination of DON in wheat.


Asunto(s)
Micotoxinas , Micotoxinas/análisis , Cromatografía Liquida/métodos , Triticum/química , Espectrometría de Masas en Tándem/métodos , Contaminación de Alimentos/análisis
4.
Anal Chim Acta ; 1278: 341673, 2023 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-37709425

RESUMEN

BACKGROUND: Phospholipids (PLs) are major constituents of cell membranes, play important roles in cell proliferation and death, as well as in signal transduction, and therefore are relevant biomarkers for different pathologies. On the other hand, when the analysis of small compounds, such as therapeutics in blood is desired, then phospholipids are part of the matrix and cause serious interference during analysis. Currently, both the analysis and removal of PLs from biological samples are limited by extensive sample preparation and instrumental separation. RESULTS: A fast and simple quantitative Ti4+-modified paper spray tandem mass spectrometric (TiPS-MS/MS) method was established in urine, where the enrichment of phospholipids was achieved, as well as reduction of matrix effects (primarily caused by high salt content) that ultimately led to improved sensitivity and selectivity. The method could achieve a physiologically relevant limit of detection (0.01-0.03 µg mL-1). Also, the usefulness of the Ti4+-modified paper was investigated in the opposite mode, namely for the selective removal of phospholipids from matrices such as plasma. Clonidine is used as model compound, as the detection of this compound is known to suffer from ion suppression by phospholipids. Compared with blank paper spray tandem mass spectrometry, the limit of detection could be improved from 0.3 µg mL-1 to 0.03 µg mL-1 by employing a Ti4+-modified paper on top of the spray tip to capture phospholipids from the sample. SIGNIFICANCE AND NOVELTY: A novel Ti4+-modified paper was developed to allow for rapid solid-phase extraction of phospholipids from urine or selective removal from plasma, followed by direct paper spray mass spectrometric detection as a fast and convenient sample preparation and analysis combination. The paper properties are based on the Ti4+ metal ion, which can selectively bind phosphate-containing compounds under acidic conditions, and its applicability was demonstrated in relevant biological matrices.


Asunto(s)
Líquidos Corporales , Espectrometría de Masas en Tándem , Titanio , Plasma , Fosfolípidos
5.
Talanta ; 257: 124366, 2023 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-36863294

RESUMEN

Food allergies are hypersensitivity immune responses triggered by (traces of) allergenic compounds in foods and drinks. The recent trend towards plant-based and lactose-free diets has driven an increased consumption of plant-based milks (PBMs) with the risk of cross-contamination of various allergenic plant-based proteins during the food manufacturing process. Conventional allergen screening is usually performed in the laboratory, but portable biosensors for on-site screening of food allergens at the production site could improve quality control and food safety. Here, we developed a portable smartphone imaging surface plasmon resonance (iSPR) biosensor composed of a 3D-printed microfluidic SPR chip for the detection of total hazelnut protein (THP) in commercial PBMs and compared its instrumentation and analytical performance with a conventional benchtop SPR. The smartphone iSPR shows similar characteristic sensorgrams compared with the benchtop SPR and enables the detection of trace levels of THP in spiked PBMs with the lowest tested concentration of 0.625 µg/mL THP. The smartphone iSPR achieved LoDs of 0.53, 0.16, 0.14, 0.06, and 0.04 µg/mL THP in 10x-diluted soy, oat, rice, coconut, and almond PBMs, respectively, with good correlation with the conventional benchtop SPR system (R2 0.950-0.991). The portability and miniaturized characteristics of the smartphone iSPR biosensor platform make it promising for the future on-site detection of food allergens by food producers.


Asunto(s)
Técnicas Biosensibles , Hipersensibilidad a los Alimentos , Humanos , Resonancia por Plasmón de Superficie/métodos , Alérgenos , Teléfono Inteligente , Técnicas Biosensibles/métodos , Límite de Detección , Hipersensibilidad a los Alimentos/diagnóstico
6.
Anal Chim Acta ; 1235: 340508, 2022 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-36368818

RESUMEN

The analysis of catecholamines, such as dopamine, epinephrine and norepinephrine in urine can be used in the diagnosis of certain pathologies, such as hormone-producing tumors. Here, a fast and simple quantitative boronate affinity paper spray tandem mass spectrometric (PS-MS/MS) method is established, which can improve selectivity and reduce ion suppression without needing any instrumental chromatography. We use here the property of boronic acids, which can selectively bind ortho-diol-containing compounds under alkaline conditions. Paper tip modification and catechol enrichment protocols were developed to selectively bind, clean up and subsequently desorb such catecholamines. Standard catecholamine solutions, as well as human urine samples were analyzed with the PS-MS(/MS) method, which is fast, cheap and easy-to-operate compared to HPLC-MS/MS. Despite its high simplicity, boronate affinity PS-MS/MS exhibits good performance compared to HPLC-MS/MS in human urine analysis in terms of precision (2.1%-7.2% vs. 1.1%-2.9%) and accuracy (-10.2%-9.3% vs. -4.8%-5.1%), and a physiologically relevant limit of detection (0.027-0.12 µg mL-1). The boronate affinity PS-MS/MS clearly achieved the detection limits that would allow the fast analysis of urine samples for clinical purposes, such as screening for pheochromocytoma (exceeding 0.5 µg mL-1).


Asunto(s)
Neoplasias de las Glándulas Suprarrenales , Catecolaminas , Humanos , Catecolaminas/química , Espectrometría de Masas en Tándem/métodos , Cromatografía Líquida de Alta Presión , Epinefrina
7.
Anal Chem ; 94(40): 13710-13718, 2022 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-36178203

RESUMEN

With the ever-evolving cannabis industry, low-cost and high-throughput analytical methods for cannabinoids are urgently needed. Normally, (potentially) psychoactive cannabinoids, typically represented by Δ9-tetrahydrocannabinol (Δ9-THC), and nonpsychoactive cannabinoids with therapeutic benefits, typically represented by cannabidiol (CBD), are the target analytes. Structurally, the former (tetrahydrocannabinolic acid (THCA), cannabinol (CBN), and THC) have one olefinic double bond and the latter (cannabidiolic acid (CBDA), cannabigerol (CBG), and CBD) have two, which results in different affinities toward Ag(I) ions. Thus, a silica gel thin-layer chromatography (TLC) plate with the lower third impregnated with Ag(I) ions enabled within minutes a digital chromatographic separation of strongly retained CBD analogues and poorly retained THC analogues. The resolution (Rs) between the closest two spots from the two groups was 4.7, which is almost 8 times higher than the resolution on unmodified TLC. After applying Fast Blue BB as a chromogenic reagent, smartphone-based color analysis enabled semiquantification of the total percentage of THC analogues (with a limit of detection (LOD) of 11 ng for THC, 54 ng for CBN, and 50 ng for THCA when the loaded volume is 1.0 µL). The method was validated by analyzing mixed cannabis extracts and cannabis extracts. The results correlated with those of high-performance liquid chromatography with ultraviolet detection (HPLC-UV) (R2 = 0.97), but the TLC approach had the advantages of multi-minute analysis time, high throughput, low solvent consumption, portability, and ease of interpretation. In a desiccator, Ag(I)-TLC plates can be stored for at least 3 months. Therefore, this method would allow rapid distinction between high and low THC varieties of cannabis, with the potential for on-site applicability.


Asunto(s)
Cannabidiol , Cannabinoides , Cannabis , Alucinógenos , Cannabidiol/análisis , Cannabinoides/análisis , Cannabinol/análisis , Cannabis/química , Cromatografía en Capa Delgada , Dronabinol/análisis , Extractos Vegetales/química , Gel de Sílice , Teléfono Inteligente , Solventes
8.
J Hazard Mater ; 432: 128692, 2022 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-35316640

RESUMEN

Polydiacetylene (PDA) is very suited for sensitively detecting large biomolecules, and its unique chromatic properties enable visual read-out. However, application to the selective detection of small molecules remains challenging. Here, bifunctional ligands are studied to amplify the color change of PDA for biorecognition of small molecules for the smartphone-based detection of diethylstilbestrol (DES). PDA is decorated with streptavidin (PDA-SA, blue), and biotin-modified DES (bio-DES) is prepared as a bifunctional ligand to couple with PDA-SA and DES antibody. Since multiple bio-DES can bind to a single SA, then multiple SAs on PDA lead to an increased surface coverage of the vesicle. In samples without DES, PDA-SA-bio-DES-DES antibody complexes will form, leading to a color transition (blue to red); this color transition is greatly amplified by antibody-induced aggregation of the complexes. When DES is present, aggregation is inhibited due to competition for the antibody and PDA-SA-bio-DES retains its blue color. A linear relationship (0.4-1250 ng mL-1) is found between the colorimetric response and the logarithmic DES concentration, with adequate selectivity, accuracy (82.24-118.64%), and precision (below 8.24%). Finally, a paper-based DES PDA biosensor is developed with visual and smartphone-based detection limits of 10 ng mL-1 and 0.85 ng mL-1 in water, respectively.


Asunto(s)
Técnicas Biosensibles , Dietilestilbestrol , Ligandos , Polímero Poliacetilénico , Teléfono Inteligente
9.
Anal Chem ; 93(41): 13904-13911, 2021 10 19.
Artículo en Inglés | MEDLINE | ID: mdl-34617742

RESUMEN

Advances in ambient ionization techniques have facilitated the direct analysis of complex mixtures without sample preparation. Significant attention has been given to innovating ionization methods so that multiple options are now available, allowing for ready selection of the best methods for particular analyte classes. These ambient techniques are commonly implemented on benchtop systems, but their potential application with miniature mass spectrometers for in situ measurements is even more powerful. These applications require that attention be paid to tailoring the mass spectrometric methodology for the on-site operation. In this study, combinations of scan modes are employed to efficiently determine what tandem mass spectrometry (MS/MS) operations are most useful for detecting sulfonamides using a miniature ion trap after ionization. First, mixtures of representative sulfonamide antibiotics were interrogated using a 2D MS/MS scan on a benchtop ion trap in order to determine which class-specific fragments (ionic or neutral) are shared between the sulfonamides and thus have diagnostic value. Then, three less-used combination scans were recorded: (i) a simultaneous precursor ion scan was used to detect both analytes and an internal standard in a single ion injection event to optimize quantitative performance; (ii) a simultaneous precursor/neutral loss scan was used to improve detection limits; and finally, (iii) the simultaneous precursor/neutral loss scan was implemented in a miniature mass spectrometer and representative sulfonamides were detected at concentrations as low as 100 ng/mL by nano-electrospray and 0.5 ng absolute by paper spray ionization, although improvements in the stability of the home-built instrumentation are needed to further optimize performance.


Asunto(s)
Espectrometría de Masa por Ionización de Electrospray , Espectrometría de Masas en Tándem , Antibacterianos , Sulfanilamida , Sulfonamidas
10.
RSC Adv ; 11(41): 25677-25685, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34354827

RESUMEN

Imprecise control of fluid flows in paper-based devices is a major challenge in pushing the innovations in this area towards societal implementation. Assays on paper tend to have low reaction yield and reproducibility issues that lead to poor sensitivity and detection limits. Understanding and addressing these issues is key to improving the performance of paper-based devices. In this work, we use colorimetric analysis to observe the mixing behaviour of molecules from two parallel flow streams in unobstructed (on unpatterned paper) and constricted flow (through the gap of a patterned hourglass structure). The model system used for characterization of mixing involved the reaction of Fe3+ with SCN- to form the coloured, soluble complex Fe(SCN)2+. At all tested concentrations (equal concentrations of 50.0 mM, 25.0 mM or 12.5 mM for KSCN and FeCl3 in each experiment), the reaction yield increases (higher colorimetric signal) and better mixing is obtained (lower relative standard deviation) as the gap of the flow constriction becomes smaller (4.69-0.32 mm). This indicates enhanced passive mixing of reagents. A transition window of gap widths exhibiting no mixing enhancement (about 2 mm) to gap widths exhibiting complete mixing (0.5 mm) is defined. The implementation of gap sizes that are smaller than 0.5 mm (below the transition window) for passive mixing is suggested as a good strategy to obtain complete mixing and reproducible reaction yields on paper. In addition, the hourglass structure was used to define the ratio of reagents to be mixed (2 : 1, 1 : 1 and 1 : 2 HCl-NaOH) by simply varying the width ratio of the input channels of the paper. This allows easy adaptation of the device to reaction stoichiometry.

11.
Anal Chem ; 93(8): 3794-3802, 2021 03 02.
Artículo en Inglés | MEDLINE | ID: mdl-33576613

RESUMEN

The control over the amount of psychoactive THC (Δ-9-tetrahydrocannabinol) in commercial cannabidiol (CBD) products has to be strict. A fast and simple semiquantitative Ag(I)-impregnated paper spray mass spectrometric method for differentiating between THC and CBD, which show no difference in standard single-stage or tandem MS, was established. Because of a different binding affinity to Ag(I) ions, quasi-molecular Ag(I) adducts [THC + Ag]+ and [CBD + Ag]+ at m/z 421 and 423 give different fragmentation patterns. The product ions at m/z 313 for THC and m/z 353 and 355 for CBD can be used to distinguish THC and CBD and to determine their ratio. Quantification of THC/CBD ratios in commercial CBD oils was accomplished with a low matrix effect (-2.2 ± 0.4% for THC and -2.0 ± 0.3% for CBD). After simple methanol extraction (recovery of 87.3 ± 1.2% for THC and 92.3 ± 1.4% for CBD), Ag(I)-impregnated paper spray analysis was employed to determine this ratio. A single run can be completed in a few minutes. This method was benchmarked against the UHPLC-UV method. Ag(I)-impregnated paper spray MS had the same working range (THC/CBD = 0.001-1) as UHPLC-UV analysis (R2 = 0.9896 and R2 = 0.9998, respectively), as well as comparable accuracy (-2.7 to 14%) and precision (RSD 1.7-11%). The method was further validated by the analysis of 10 commercial oils by Ag(I)-impregnated paper spray MS and UHPLC-UV analysis. Based on the determined relative concentration ratios of THC/CBD and the declared CBD concentration, 6 out of 10 CBD oils appear to contain more THC than the Dutch legal limit of 0.05%.


Asunto(s)
Cannabidiol , Dronabinol , Espectrometría de Masas , Extractos Vegetales , Plata
12.
Anal Chim Acta ; 1140: 190-198, 2020 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-33218481

RESUMEN

While consumer-focused food analysis is upcoming, the need for multiple sample preparation and handling steps is limiting. On-site and consumer-friendly analysis paradoxically still requires laboratory-based and skill-intensive sample preparation methods. Here, we present a compact, inexpensive, and novel prototype immunosensor combining sample preparation and on-chip reagent storage for multiplex allergen lateral flow immunosensing. Our comprehensive approach paves the way for personalized consumer diagnostics. The prototype allows for handheld solid-liquid extraction, pipette-free on-chip dilution, and adjustment of sample concentrations into the appropriate assay dynamic working range. The disposable and interconnectable homogenizer unit allows for the extraction and 3D-sieve based filtration of allergenic proteins from solid bakery products in 1 min. The homogenizer interconnects with a 3D-printed unibody lab-on-a-chip (ULOC) microdevice, which is used to deliver precise volumes of sample extract to a reagent reservoir. The reagent reservoir is implemented for on-chip storage of carbon nanoparticle labeled antibodies and running buffer for dilution. The handheld prototype allows for total homogenization of solid samples, solid-liquid protein extraction, 3D-printed sieve based filtration, ULOC-enabled dilution, mixing, transport, and smartphone-based detection of hazelnut and peanut allergens in solid bakery products with limited operational complexity. The multiplex lateral flow immunoassay (LFIA) detects allergens as low as 0.1 ppm in real bakery products, and the system is already consumer-operable, demonstrating its potential for future citizen science approaches. The designed system is suitable for a wide range of analytical applications outside of food safety, provided an LFIA is available.


Asunto(s)
Técnicas Biosensibles , Alérgenos , Inmunoensayo , Dispositivos Laboratorio en un Chip , Teléfono Inteligente
13.
Anal Chem ; 92(23): 15587-15595, 2020 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-33185097

RESUMEN

Sandwich lateral flow immunoassays (LFIAs) are limited at high antigen concentrations by the hook effect, leading to a contradictory decrease in the test line (T) intensity and false-negative results. The hook effect is mainly associated with the loss of T, and research focuses on minimizing this effect. Nevertheless, the control line (C) intensity is also affected at higher analyte concentrations, undesirably influencing the T/C ratio in LFIA readers. The main aim of this work is to identify and understand these high antigen concentration effects in order to develop ubiquitous strategies to interpret and mitigate such effects. Four complementary experiments were performed: performance assessment of three different allergen LFIAs (two for hazelnut, one for peanut) over 0.075-3500 ppm, LFIAs with C only, surface plasmon resonance (SPR) binding experiments on the immobilized control antibody, and smartphone video recording of LFIAs during their development. As antigen concentrations increase, the C signal decreases before the T signal does, suggesting that distinct mechanisms underlie these intensity reductions. Reduced binding at the C occurred even in the absence of T, so the upfront T does not explain the loss of C. SPR confirmed that the C antibody favors binding with free labeled antibody compared with a labeled antibody-analyte complex, indicating that in antigen excess, binding is reduced at C before T. Finally, a smartphone-based video method was developed for dynamically monitoring the LFIA development in real time to distinguish between different concentration-dependent effects. Digitally analyzing the data allows clear differentiation of highly positive samples and false-negative samples and can indicate whether the LFIA is in the dynamic working range or at critically high concentrations. The aim of this work is to identify and understand such high antigen concentration effects in order to develop ubiquitous strategies to interpret and mitigate such effects.


Asunto(s)
Alérgenos/análisis , Inmunoensayo/métodos , Alérgenos/inmunología , Anticuerpos Inmovilizados/química , Anticuerpos Inmovilizados/inmunología , Arachis/inmunología , Corylus/inmunología , Inmunoensayo/instrumentación , Límite de Detección , Teléfono Inteligente , Propiedades de Superficie
14.
Biosensors (Basel) ; 9(4)2019 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-31842439

RESUMEN

(1) Background: The lack of globally standardized allergen labeling legislation necessitates consumer-focused multiplexed testing devices. These should be easy to operate, fast, sensitive and robust. (2) Methods: Herein, we describe the development of three different formats for multiplexed food allergen detection, namely active and passive flow-through assays, and lateral flow immunoassays with different test line configurations. (3) Results: The fastest assay time was 1 min, whereas even the slowest assay was within 10 min. With the passive flow approach, the limits of detection (LOD) of 0.1 and 0.5 ppm for total hazelnut protein (THP) and total peanut protein (TPP) in spiked buffer were reached, or 1 and 5 ppm of THP and TPP spiked into matrix. In comparison, the active flow approach reached LODs of 0.05 ppm for both analytes in buffer and 0.5 and 1 ppm of THP and TPP spiked into matrix. The optimized LFIA configuration reached LODs of 0.1 and 0.5 ppm of THP and TPP spiked into buffer or 0.5 ppm for both analytes spiked into matrix. The optimized LFIA was validated by testing in 20 different blank and spiked matrices. Using device-independent color space for smartphone analysis, two different smartphone models were used for the analysis of optimized assays.


Asunto(s)
Alérgenos/análisis , Técnicas Biosensibles , Hipersensibilidad a los Alimentos/diagnóstico , Inmunoensayo , Teléfono Inteligente , Hipersensibilidad a los Alimentos/inmunología , Humanos
15.
Anal Chim Acta ; 1000: 180-190, 2018 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-29289307

RESUMEN

We propose the use of water-based alkyl ketene dimer (AKD) ink for fast and user-friendly patterning of paper microfluidic devices either manually or using an inexpensive XY-plotter. The ink was produced by dissolving hydrophobic AKD in chloroform and emulsifying the solution in water. The emulsification was performed in a warm water bath, which led to an increased rate of the evaporation of chloroform. Subsequent cooling led to the final product, an aqueous suspension of fine AKD particles. The effects of surfactant and AKD concentrations, emulsification procedure, and cooling approach on final ink properties are presented, along with an optimized protocol for its formulation. This hydrophobic agent was applied onto paper using a plotter pen, after which the paper was heated to allow spreading of AKD molecules and chemical bonding with cellulose. A paper surface patterned with the ink (10 g L-1 AKD) yielded a contact angle of 135.6° for water. Unlike organic solvent-based solutions of AKD, this AKD ink does not require a fume hood for its use. Moreover, it is compatible with plastic patterning tools, due to the effective removal of chloroform in the production process to less than 2% of the total volume. Furthermore, this water-based ink is easy to prepare and use. Finally, the AKD ink can also be used for the fabrication of so-called selectively permeable barriers for use in paper microfluidic networks. These are barriers that stop the flow of water through paper, but are permeable to solvents with lower surface energies. We applied the AKD ink to confine and preconcentrate sample on paper, and demonstrated the use of this approach to achieve higher detection sensitivities in paper spray ionization-mass spectrometry (PSI-MS). Our patterning approach can be employed outside of the analytical lab or machine workshop for fast prototyping and small-scale production of paper-based analytical tools, for use in limited-resource labs or in the field.

16.
Lab Chip ; 17(20): 3401-3404, 2017 10 11.
Artículo en Inglés | MEDLINE | ID: mdl-28937160

RESUMEN

Proof-of-concept is shown for two-phase countercurrent flow on paper. The device consists of two paper layers, one of which has been modified with a sizing agent to be hydrophobic. The layers exhibit different wetting behavior for water and octanol. Both phases dominate wetting in one of the layers and can be made to move in different directions along the interface to achieve liquid-liquid extraction.

17.
Anal Chem ; 89(13): 7053-7061, 2017 07 05.
Artículo en Inglés | MEDLINE | ID: mdl-28628294

RESUMEN

In this work, the use of fused deposition modeling (FDM) in a (bio)analytical/lab-on-a-chip research laboratory is described. First, the specifications of this 3D printing method that are important for the fabrication of (micro)devices were characterized for a benchtop FDM 3D printer. These include resolution, surface roughness, leakage, transparency, material deformation, and the possibilities for integration of other materials. Next, the autofluorescence, solvent compatibility, and biocompatibility of 12 representative FDM materials were tested and evaluated. Finally, we demonstrate the feasibility of FDM in a number of important applications. In particular, we consider the fabrication of fluidic channels, masters for polymer replication, and tools for the production of paper microfluidic devices. This work thus provides a guideline for (i) the use of FDM technology by addressing its possibilities and current limitations, (ii) material selection for FDM, based on solvent compatibility and biocompatibility, and (iii) application of FDM technology to (bio)analytical research by demonstrating a broad range of illustrative examples.


Asunto(s)
Materiales Biocompatibles/química , Polímeros/química , Impresión Tridimensional , Diseño de Equipo , Dispositivos Laboratorio en un Chip , Microfluídica/instrumentación , Impresión Tridimensional/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...