Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Ultrasound Obstet Gynecol ; 62(4): 540-551, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37204929

RESUMEN

OBJECTIVE: Monochorionic (MC) triplet pregnancies are extremely rare and information on these pregnancies and their complications is limited. We aimed to investigate the risk of early and late pregnancy complications, perinatal outcome and the timing and methods of fetal intervention in these pregnancies. METHODS: This was a multicenter retrospective cohort study of MC triamniotic (TA) triplet pregnancies managed in 21 participating centers around the world from 2007 onwards. Data on maternal age, mode of conception, diagnosis of major fetal structural anomalies or aneuploidy, gestational age (GA) at diagnosis of anomalies, twin-to-twin transfusion syndrome (TTTS), twin anemia-polycythemia sequence (TAPS), twin reversed arterial perfusion (TRAP) sequence and or selective fetal growth restriction (sFGR) were retrieved from patient records. Data on antenatal interventions were collected, including data on selective fetal reduction (three to two or three to one), laser surgery and any other active fetal intervention (including amniodrainage). Data on perinatal outcome were collected, including numbers of live birth, intrauterine demise, neonatal death, perinatal death and termination of fetus or pregnancy (TOP). Neonatal data such as GA at birth, birth weight, admission to neonatal intensive care unit and neonatal morbidity were also collected. Perinatal outcomes were assessed according to whether the pregnancy was managed expectantly or underwent fetal intervention. RESULTS: Of an initial cohort of 174 MCTA triplet pregnancies, 11 underwent early TOP, three had an early miscarriage, six were lost to follow-up and one was ongoing at the time of writing. Thus, the study cohort included 153 pregnancies, of which the majority (92.8%) were managed expectantly. The incidence of pregnancy affected by one or more fetal structural abnormality was 13.7% (21/153) and that of TRAP sequence was 5.2% (8/153). The most common antenatal complication related to chorionicity was TTTS, which affected just over one quarter (27.6%; 42/152, after removing a pregnancy with TOP < 24 weeks for fetal anomalies) of the pregnancies, followed by sFGR (16.4%; 25/152), while TAPS (spontaneous or post TTTS with or without laser treatment) occurred in only 4.6% (7/152) of pregnancies. No monochorionicity-related antenatal complication was recorded in 49.3% (75/152) of pregnancies. Survival was apparently associated largely with the development of these complications: there was at least one survivor beyond the neonatal period in 85.1% (57/67) of pregnancies without antenatal complications, in 100% (25/25) of those complicated by sFGR and in 47.6% (20/42) of those complicated by TTTS. The overall rate of preterm birth prior to 28 weeks was 14.5% (18/124) and that prior to 32 weeks' gestation was 49.2% (61/124). CONCLUSION: Monochorionicity-related complications, which can impact adversely perinatal outcome, occur in almost half of MCTA triplet pregnancies, creating a challenge with regard to counseling, surveillance and management. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

2.
Ultrasound Obstet Gynecol ; 53(1): 95-100, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29749657

RESUMEN

OBJECTIVE: To investigate the association between application of fundal pressure during the second stage of labor (Kristeller maneuver) and the risk of levator ani muscle (LAM) injury. METHODS: This was a prospective case-control study of women recruited immediately after their first vaginal delivery in our university hospital between March 2014 and September 2016. Women who underwent the Kristeller maneuver were recruited as cases. For each case, a control (no Kristeller) was recruited matched for body mass index, use of epidural analgesia, duration of second stage of labor and birth weight. All women were invited to undergo four-dimensional (4D) transperineal ultrasound (TPU) 3-6 months postpartum. The main outcome measure was the presence of LAM avulsion on 4D-TPU. TPU results were compared between cases and controls. Multivariate logistic regression analysis was performed to identify independent risk factors for LAM avulsion. RESULTS: During the study period, 134 women in the Kristeller maneuver group and 128 women in the control group underwent TPU assessment. Women who underwent the Kristeller maneuver had a higher prevalence of LAM avulsion than did controls (38/134 (28.4%) vs 18/128 (14.1%); P = 0.005). In addition, women in the Kristeller-maneuver group had a larger hiatal area on maximum Valsalva maneuver and a greater increase in hiatal area from rest to maximum Valsalva. On multivariate logistic regression analysis, use of the Kristeller maneuver was the only independent factor associated with LAM avulsion (odds ratio, 2.5 (95% CI, 1.29-4.51)). CONCLUSION: The Kristeller maneuver is associated with an increased risk of LAM avulsion when applied in women during their first vaginal delivery. This should be taken into account when deciding to use fundal pressure to accelerate the second stage of labor and when counseling women following childbirth. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.


Asunto(s)
Canal Anal/lesiones , Segundo Periodo del Trabajo de Parto , Trastornos del Suelo Pélvico/epidemiología , Presión/efectos adversos , Adulto , Canal Anal/diagnóstico por imagen , Estudios de Casos y Controles , Parto Obstétrico/métodos , Femenino , Humanos , Italia/epidemiología , Complicaciones del Trabajo de Parto/epidemiología , Complicaciones del Trabajo de Parto/etiología , Trastornos del Suelo Pélvico/etiología , Embarazo , Resultado del Embarazo , Estudios Prospectivos , Factores de Riesgo
3.
Ultrasound Obstet Gynecol ; 51(3): 357-360, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28337810

RESUMEN

OBJECTIVES: To compare the efficiency of electronic spatiotemporal image correlation (eSTIC) with that of conventional STIC to acquire four-dimensional (4D) fetal cardiac volumes of diagnostic quality. METHODS: This was a randomized controlled trial of 100 patients in mid-gestation with normal sonograms. In half of the cases, STIC volumes of the fetal heart were obtained with a conventional mechanical 4D probe and in the remaining cases eSTIC volumes were obtained with an electronic 4D probe. Examinations were kept within the timeframe allotted for a standard examination of fetal anatomy, and a maximum of two attempts were made at obtaining a 4D cardiac volume. Datasets were stored on a computer and subsequently analyzed and categorized as being of optimal, satisfactory or inadequate quality, depending on whether or not it was possible to perform an extended basic cardiac examination, including obtaining a three vessels and trachea view, as well as a clear reconstruction of both the aortic and ductal arches in the sagittal plane. RESULTS: The eSTIC volume datasets were more frequently of optimal or satisfactory diagnostic quality compared with conventional STIC (94% vs 76%, P < 0.0001). Failure to obtain an eSTIC volume of adequate quality was in all cases the consequence of an unfavorable position of the fetus. CONCLUSIONS: Compared with a standard mechanical probe, the electronic 4D probe facilitates acquisition of sonographic cardiac volumes in mid-trimester fetuses. In our hands, eSTIC volumes of optimal or satisfactory diagnostic quality, allowing a detailed offline evaluation of the fetal heart, were obtained in more than 90% of cases within the time frame of a standard examination of fetal anatomy. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.


Asunto(s)
Ecocardiografía Tetradimensional , Corazón Fetal/diagnóstico por imagen , Cardiopatías Congénitas/diagnóstico por imagen , Ultrasonografía Prenatal , Adulto , Volumen Cardíaco , Femenino , Corazón Fetal/fisiopatología , Edad Gestacional , Cardiopatías Congénitas/embriología , Cardiopatías Congénitas/fisiopatología , Humanos , Interpretación de Imagen Asistida por Computador , Embarazo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
4.
Ultrasound Obstet Gynecol ; 50(3): 388-394, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27642724

RESUMEN

OBJECTIVES: Caudal distension of the female pelvic floor is common and results in perineal descent and a caudally curved levator hiatus (warping). Image reconstruction of the pelvic floor using currently available ultrasound techniques involves a linear approach (flat-plane reconstruction). We aimed to evaluate the feasibility, reproducibility and potential usefulness of a new three-dimensional (3D) technique capable of reconstructing a curved plane of the levator hiatus. METHODS: Primiparous women were recruited to undergo a 3D/four-dimensional transperineal ultrasound examination 3-6 months after delivery. Levator ani muscle warping was evaluated on Valsalva maneuver by measuring the distance between the plane extending from the pubic rami to the anorectal angle and the plane of minimal hiatal dimensions on the coronal plane. Warping distance was used to reconstruct a curved plane of the levator hiatus using the curved OmniView volume contrast imaging (VCI) technique (C-OV). Intra- and interobserver reproducibility of the C-OV technique were assessed, as was intermethod agreement between the C-OV technique and the linear OmniView-VCI (L-OV) technique, for the measurement of levator hiatal area on Valsalva maneuver. RESULTS: Measurement of the levator hiatal area using C-OV was feasible in all 84 women recruited. The warping distance ranged from -3.5 to 9.7 mm, confirming that the 1-2-cm slice thickness traditionally used for linear reconstruction was adequate for proper assessment of levator hiatal area in our population. C-OV showed excellent intra- and interobserver reproducibility, as well as excellent agreement with the L-OV technique for measuring levator hiatal area. No systematic difference was demonstrated in any of the reproducibility studies performed. CONCLUSIONS: 3D reconstruction of the warped levator hiatal plane is feasible and highly reproducible. In our population, reconstruction of a curved plane to correct for levator hiatal warping did not offer any benefit over the traditionally performed linear reconstruction. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.


Asunto(s)
Diafragma Pélvico/diagnóstico por imagen , Prolapso de Órgano Pélvico/diagnóstico por imagen , Ultrasonografía Prenatal , Adulto , Femenino , Humanos , Imagenología Tridimensional , Paridad , Prolapso de Órgano Pélvico/fisiopatología , Valor Predictivo de las Pruebas , Embarazo , Estudios Prospectivos , Maniobra de Valsalva
6.
Ultrasound Obstet Gynecol ; 47(5): 629-35, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26105710

RESUMEN

OBJECTIVE: To assess the reproducibility of a new technique for three-/four-dimensional (3D/4D) ultrasound imaging of the pelvic floor: OmniView™ volume contrast imaging (VCI) for measurement of the pelvic hiatal area on maximum contraction and Valsalva maneuver. In addition, we aimed to study the intermethod agreement between the new technique and the 3D/4D render method. METHODS: We acquired one static 3D and two dynamic 4D transperineal volumes (one obtained during contraction and one during Valsalva maneuver) from 35 nulliparous asymptomatic healthy volunteers and 35 women with symptoms of pelvic floor dysfunction. Each 3D dataset was analyzed using the OmniView-VCI technique to measure the pelvic hiatal area at rest, on maximum contraction and on maximum Valsalva. Analysis was performed twice by the same operator and once by another operator in order to assess intra- and interobserver reproducibility. All measurements were repeated by one operator using the 3D/4D render method to evaluate the intermethod agreement. Reproducibility and intermethod agreement were studied by means of intraclass correlation coefficients (ICC) and the Bland-Altman method. RESULTS: Measurement of hiatal area using the OmniView-VCI technique showed excellent intraobserver and interobserver reproducibility in both asymptomatic and symptomatic women at rest, on contraction and on Valsalva maneuver. In addition, excellent agreement was demonstrated between OmniView-VCI and 3D/4D render in both groups (ICCs on Valsalva in asymptomatic and symptomatic women were 0.894 and 0.975, respectively). No systematic difference was noted in any of the reliability studies performed. CONCLUSIONS: OmniView-VCI is a reliable method for pelvic hiatal area measurement. Both rendering mode and OmniView-VCI can be used interchangeably for assessing pelvic hiatal area. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.


Asunto(s)
Imagenología Tridimensional/instrumentación , Diafragma Pélvico/diagnóstico por imagen , Ultrasonografía/instrumentación , Femenino , Humanos , Imagenología Tridimensional/métodos , Variaciones Dependientes del Observador , Embarazo , Reproducibilidad de los Resultados , Ultrasonografía/métodos
7.
Prenat Diagn ; 35(9): 919-22, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26126648

RESUMEN

OBJECTIVE: The aim of this research was to determine the prevalence and sonographic appearance of the hippocampal commissure in fetuses with isolated complete agenesis of the corpus callosum by three-dimensional neurosonography in the multiplanar mode. METHODS: This was a multicenter observational study. Stored volume datasets of fetuses with isolated complete agenesis of the corpus were retrospectively retrieved for analysis in three tertiary centers. The presence or absence of the hippocampal commissure was independently evaluated in the coronal and midsagittal planes by two operators. Postnatal follow-up was obtained in all cases. RESULTS: From November 2007 to February 2013, 41 cases between 19 and 30 weeks of gestation were retrieved for analysis. The hippocampal commissure was visible in the coronal and sagittal planes in 27/41 (65.8%), absent or not clearly recognizable in the remaining 14 cases. The qualitative analysis of the two operators was concordant in 100% of cases. CONCLUSIONS: In more than half of fetuses with complete callosal agenesis, the hippocampal commissure may be visualized at prenatal ultrasound. This is a residual interhemispheric connection, which in normal cases is hidden by the corpus callosum itself. Further research is needed to establish if this has an impact on postnatal outcome.


Asunto(s)
Agenesia del Cuerpo Calloso/diagnóstico por imagen , Fórnix/diagnóstico por imagen , Ultrasonografía Prenatal , Adulto , Agenesia del Cuerpo Calloso/embriología , Femenino , Estudios de Seguimiento , Fórnix/anomalías , Fórnix/embriología , Humanos , Imagenología Tridimensional , Embarazo , Estudios Retrospectivos , Ultrasonografía Prenatal/métodos
8.
J Obstet Gynaecol ; 35(5): 461-4, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25357086

RESUMEN

In our questionnaire, a video tutorial illustrating the management of shoulder dystocia was considered by health personnel as a useful complementary training tool. We prepared a 5-min video tutorial on the management of shoulder dystocia, using a simulator that includes maternal pelvic and baby models. We performed a survey among obstetric personnel in order to assess their opinion on the tutorial by inviting them to watch the video tutorial and answer an online questionnaire. Five multiple-choice questions were set, focusing on the video's main objectives: clarity, simplicity and usefulness. Following the collection of answers, global and category-weighted analyses were conducted for each question. Out of 956 invitations sent, 482 (50.4%) answered the survey. More than 90% of all categories found the video tutorial to be clinically relevant and clear. For revising the management of shoulder dystocia most obstetric personnel would use the video tutorial together with traditional textbooks. In conclusion, our video tutorial was considered by health personnel as a useful complementary training tool.


Asunto(s)
Distocia/terapia , Obstetricia/educación , Algoritmos , Femenino , Humanos , Embarazo , Encuestas y Cuestionarios , Grabación en Video
9.
J Matern Fetal Neonatal Med ; 28(16): 1985-8, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25316562

RESUMEN

OBJECTIVE: To compare the accuracy of transperineal (TP) ultrasound with transabdominal (TA) approach in the sonographic assessment of fetal occiput position during the second stage of labour. METHODS: A series of low-risk women at term attending the labour ward of three university hospitals were prospectively recruited for the purpose of this study. During the second stage of labor patients were evaluated first by TP and than by TA ultrasound to determine the fetal position. The occiput position was labelled as DOA (direct occiput anterior), ROA (right occiput anterior), LOA (left occiput anterior), DOP (direct occiput posterior), ROP (right occiput posterior), LOP (left occiput posterior), ROT (right occuput transverse) and LOT (left occiput transverse). The agreement between the two techniques was assessed. RESULTS: Overall 80 patients were recruited in the study group. Ultrasound examination was performed at 21(± 8) minutes from the beginning of the active pushing. The ultrasound findings of the fetal occiput position were recorded. In all cases TA ultrasound confirmed the fetal occiput position as determined at TP approach except in one case of ROA that had been recorded as ROT using TP ultrasound. CONCLUSIONS: Ultrasound TP examination is accurate in the diagnosis of fetal occiput position during the second stage of labor.


Asunto(s)
Cabeza/diagnóstico por imagen , Presentación en Trabajo de Parto , Segundo Periodo del Trabajo de Parto , Ultrasonografía Prenatal/métodos , Abdomen , Adulto , Femenino , Humanos , Perineo , Embarazo , Estudios Prospectivos
11.
Ultrasound Obstet Gynecol ; 43(2): 183-8, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24006290

RESUMEN

OBJECTIVES: To assess the intermethod agreement between two-dimensional (2D) and three-dimensional (3D) transperineal ultrasound methods in measuring a new index of fetal head station (the fetal head-symphysis distance (HSD)) in active labor, and to assess potential factors that may affect their agreement. METHODS: HSD was measured by transperineal ultrasound in 86 women in active labor, once using a 2D and once using a 3D technique. 2D images were acquired first in 43 cases and 3D images were acquired first in the other 43 women. Intermethod agreement between 2D and 3D methods was analyzed by means of intraclass correlation coefficient (ICC) and Bland-Altman analysis. In addition, potential factors affecting the intermethod reproducibility were investigated including fetal occiput position, order of acquisition, fetal head station, stage of labor, maternal body mass index and use of epidural analgesia, using the ANOVA test to check for systematic bias and Levene's test for homoscedasticity. RESULTS: Good agreement was demonstrated between 2D and 3D measurements of HSD (ICC, 0.949 (95% CI, 0.914-0.984)). No evidence of systematic difference was shown between the two methods (average difference ± SD = 0.03 ± 2.29 mm; P = 0.888). The only factor that had a significant effect on systematic difference between 2D and 3D methods was order of acquisition (P = 0.042); the first observation was higher regardless of the method used. Fetal head station had a significant effect on the homogeneity between the two methods (P = 0.004) with a better 2D-3D agreement obtained at lower head stations (SD of differences: 1.63 vs 2.59 mm). CONCLUSIONS: There is very good agreement between 2D and 3D methods of assessing HSD. Agreement is better in lower fetal head stations.


Asunto(s)
Cabeza/diagnóstico por imagen , Trabajo de Parto/fisiología , Perineo/diagnóstico por imagen , Sínfisis Pubiana/diagnóstico por imagen , Ultrasonografía Prenatal/métodos , Adulto , Femenino , Humanos , Imagenología Tridimensional , Presentación en Trabajo de Parto , Persona de Mediana Edad , Embarazo , Reproducibilidad de los Resultados
12.
Ultrasound Obstet Gynecol ; 41(4): 419-24, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23124698

RESUMEN

OBJECTIVES: To assess the reproducibility of measurement of a new sonographic index of fetal head station in labor, the fetal head-symphysis distance (HSD), using three-dimensional ultrasound, and its correlation with digital assessment of fetal head descent and with the angle of progression (AoP). METHODS: Three-dimensional (3D) ultrasound volumes were acquired from 47 nulliparous women in active labor following assessment of fetal head station with digital examination. The HSD (the distance between the lower edge of the pubic symphysis and the nearest point of the fetal skull) was measured independently by two operators in order to evaluate intra- and interobserver reproducibility. The correlation between HSD, AoP and fetal head station was evaluated using regression analysis. Using 3D tomographic ultrasound imaging (TUI), measurements of the HSD were obtained in different parasagittal planes to evaluate the influence of inaccurate alignment of the probe with the midline of the pelvis. RESULTS: Measurement of HSD showed high intraobserver (intraclass correlation coefficient (ICC) = 0.995; 95% CI, 0.991-0.997) and interobserver (ICC = 0.991; 95% CI, 0.984-0.995) reliability. In addition, a high correlation was demonstrated between mid-sagittal and parasagittal HSD measurements. HSD showed significant negative correlation with both fetal head station and AoP. CONCLUSION: Fetal HSD is a simple and reliable method for the assessment of fetal head descent in labor.


Asunto(s)
Imagenología Tridimensional/métodos , Presentación en Trabajo de Parto , Primer Periodo del Trabajo de Parto/fisiología , Segundo Periodo del Trabajo de Parto/fisiología , Tomografía/métodos , Ultrasonografía Prenatal/métodos , Adolescente , Adulto , Femenino , Humanos , Palpación , Embarazo , Reproducibilidad de los Resultados , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...