Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Am J Hosp Palliat Care ; 32(7): 715-24, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24928837

RESUMEN

This study was aimed at piloting a school-based intervention on severe illness, within a project focused on spreading knowledge of palliative care among high school students (phases 0-2 Medical Research Council Framework). The intervention entailed the screening of a topic-related movie, 2 classroom meetings, and the development of a class-based multimedia production. Five classes from 5 high schools participated in this study, and a before-after evaluation was used to assess intervention feasibility and impact. Valid questionnaires were filled in by 84% (before) and 79% (after) of the 89 students. Concerning students' knowledge on palliative care, the after evaluation showed a significantly higher paired proportions of students reporting on "improving patient quality of life" and "life-threatening illness." Intervention components were deemed helpful by students, and positive feedback on the experience was given.


Asunto(s)
Intervención Educativa Precoz , Educación en Salud , Conocimientos, Actitudes y Práctica en Salud , Cuidados Paliativos , Calidad de Vida , Índice de Severidad de la Enfermedad , Estudiantes/psicología , Adolescente , Adulto , Curriculum , Femenino , Humanos , Masculino , Proyectos Piloto , Encuestas y Cuestionarios , Adulto Joven
2.
Pediatr Med Chir ; 26(6): 439-44, 2004.
Artículo en Italiano | MEDLINE | ID: mdl-16363770

RESUMEN

In HIV infected children, CD45+CD4+ T lymph. reconstitution has been related to efficient thymopoiesis. Because human thymus undergoes spontaneous involution at a relatively young age, institution of antiretroviral therapy early in the course of infection has been recommended. 12 HIV vertically infected children aged 4-8 years were investigated T-cell subsets for four years. 7 children were naive for therapy (group NT); 5 experienced nucleoside analogues only (group T). CD45RA+ and CD45RO+ CD4+ values were compared to predicted values of healthy children. The two groups showed similar clinical and immunological baseline characteristics (CDC class N-A). Mean VL at t0 was 4.26 log10 (SD 0.71) in gr. NT and 4.01 log10 (SD 0.57) in gr. T; median CD4 T lymph values were 27% in gr. NT and 23.5% in gr. T. Median CD45RA+ values were 62.8% in gr. NT and 71.3% in gr. T. No differences in VL, CD4+ T lymph., CD45RA+, CD45RO+ were found in between groups or within each group at each time evaluation. Median CD45RA+ values were not different from predicted values of healthy children. None of the children changed CDC class during the study period. Although the number of subjects was small, our study evidenced the possibility of a normal immunological development in HIV-1 vertically infected asymptomatic children naive for HAART during the first decade, even in the presence of significant viremia.


Asunto(s)
Infecciones por VIH/inmunología , Infecciones por VIH/transmisión , Transmisión Vertical de Enfermedad Infecciosa , Recuento de Linfocito CD4 , Niño , Preescolar , Estudios de Seguimiento , Humanos , Estudios Prospectivos
3.
Radiol Med ; 91(4): 460-6, 1996 Apr.
Artículo en Italiano | MEDLINE | ID: mdl-8643860

RESUMEN

Spiral or volumetric computed tomography (CT) is a new scanning technique which allows the scanning of body regions with a continuously rotating system based on the slip ring technology; the patient is also moved continuously, synchronously with data acquisition. The physical characteristics of spiral CT image acquisition were compared with those of conventional CT images. The modulation transfer function (MTF) has the same values for medium-resolution filters, but lower values for spiral CT for high-resolution and frequency-enhancement filters. The slice sensitivity profile (SSP) describes the longitudinal image resolution for multiplanar reconstructions and was measured in terms of FWHM of the SSP curve. We obtained, for 10-mm slice thickness, a FWHM = 10.4 mm (conventional CT), versus 10.7 mm (Spiral CT), while, for 5-mm slice thickness, the corresponding values were 5.2 mm (conventional CT) and 5.5 mm (spiral CT). Noise was evaluated simply by measuring the standard deviation of the CT numbers, in a region of interest, of a uniform image and with the power spectrum or Wiener spectrum of the same image. To assess overall image quality and yield, the noise equivalent quanta (NEQ) value was also calculated. The values were a little lower for the spiral technique, particularly with high-resolution and enhancement or convolution filters. Dosimetric evaluation of the computed tomography dose index (CTDI) and of the multiple scan average dose (MSAD) was done using an acquisition protocol for average lung dose, in an anthropomorphic phantom and with TL dosimeters. The MSAD was 6.17 +/- 0.20 cGy for conventional CT and 5.98 +/- 0.23 cGy for Spiral CT, while lung dose was 3.25 +/- 0.12 cGy and 3.01 +/- 0.16 cGy, respectively.


Asunto(s)
Tomografía Computarizada por Rayos X/instrumentación , Artefactos , Humanos , Fantasmas de Imagen , Dosis de Radiación , Sensibilidad y Especificidad , Dosimetría Termoluminiscente , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/estadística & datos numéricos
4.
Radiol Med ; 87(6): 847-51, 1994 Jun.
Artículo en Italiano | MEDLINE | ID: mdl-8041940

RESUMEN

Digital radiography (DR) based on storage phosphor technology is progressively replacing conventional screen-film system radiographic techniques (CR). However, many questions about image quality and dose reduction are still open. Thus, since DR spatial resolution is always lower than that of high quality screen-film images and image noise is conversely higher, for general radiography examinations especially, the signal-to-noise ratio is always lower with DR than with CR at the same dose level. However, the wide dynamic range, the linear response of storage phosphor detectors and the automatic read-out control of the digital system, enable lower DR X-ray imaging efficiency to be overcome, producing a nearly perfect readout of the image data every time an exposure is made. Moreover, post-processing can make the detection of abnormalities easier. This is why in many ROC clinical accuracy studies DR performed equally or better than CR. Good quality DR images, similar to conventional ones at the same dose levels, are therefore achievable in chest, abdomen, bone and soft-tissues examinations. Dose evaluation protocols are strongly needed in DR since overexposures due to technical mistakes may be overlooked; moreover, doses can be adjusted to the peculiar diagnostic need. The S values shown on any hard-copy image can be used to this purpose, even though it must be pointed out that they do not express the actual mean dose to the detector.


Asunto(s)
Intensificación de Imagen Radiográfica/métodos , Humanos , Fenómenos Físicos , Física , Control de Calidad , Dosis de Radiación , Intensificación de Imagen Radiográfica/instrumentación , Intensificación de Imagen Radiográfica/normas , Estadística como Asunto
5.
Acta Radiol ; 35(3): 230-4, 1994 May.
Artículo en Inglés | MEDLINE | ID: mdl-8192958

RESUMEN

CT is seldom employed in adult respiratory distress syndrome (ARDS), mostly due to problems in transporting and monitoring these severely ill patients. We reviewed the findings of 74 ARDS patients who underwent chest CT. Lung opacities were bilateral in almost all patients and dependent in most cases (86%). The opacities were patchy (42%), homogeneous (23%), ground glass (8%) or mixed (27%). Opacities prevailed in basal regions (68%) compared to hilar and apical ones. Air bronchograms were frequently seen in areas of consolidation (89%). In contrast with previous reports, pleural effusion was a frequent finding (50%) that did not worsen prognosis. Often loculated pneumothorax (32%) was mostly anteromedial. Ineffective position of thoracostomy tubes was detected at CT in 13/20 patients. Pulmonary air cysts (30%), always multiple and mostly bilateral, were associated with a higher mortality (55%) than that of the whole study group (35%). Compared to chest radiographs, CT often yielded additional information (66%), with direct influence on patient treatment in 22% of cases.


Asunto(s)
Síndrome de Dificultad Respiratoria/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Femenino , Humanos , Pulmón/diagnóstico por imagen , Absceso Pulmonar/complicaciones , Absceso Pulmonar/diagnóstico por imagen , Masculino , Enfisema Mediastínico/complicaciones , Enfisema Mediastínico/diagnóstico por imagen , Persona de Mediana Edad , Derrame Pleural/complicaciones , Derrame Pleural/diagnóstico por imagen , Neumotórax/complicaciones , Neumotórax/diagnóstico por imagen , Radiografía Torácica , Síndrome de Dificultad Respiratoria/complicaciones
6.
Radiol Med ; 87(4): 401-4, 1994 Apr.
Artículo en Italiano | MEDLINE | ID: mdl-8190921

RESUMEN

The diagnostic accuracy of the light-box reading of conventional (film screen) radiographs of the extremities was compared with that of the same set of images displayed on a 1 k x 1 k interactive monitor after laser digitization. 389 alterations (23 nondisplaced fractures, 129 soft-tissue calcifications and 237 articular bone erosions), identified by two experienced radiologists on 66 conventional radiographs, were the reference standard. ROC statistical analysis was performed on 1,556 observations expressed by four readers. The overall diagnostic performance of the two display modalities were substantially equivalent: no statistically significant differences resulted on the whole, but two individual readers performed better with conventional images. No overall nor individual statistically significant difference was reobserved for the subset of articular erosions either. Light-box reading of conventional radiographs allowed a higher number of calcifications in the soft-tissues and of proximal (carpal) abnormalities to be detected. Although our results indicate the overall high fidelity of monitor-displayed laser-digitized images, major improvements in the performance of digital diagnostic workstations are still required before adopting monitors for routine radiologic activity.


Asunto(s)
Antepié Humano/diagnóstico por imagen , Mano/diagnóstico por imagen , Televisión/instrumentación , Articulación de la Muñeca/diagnóstico por imagen , Estudios de Evaluación como Asunto , Humanos , Variaciones Dependientes del Observador , Curva ROC , Intensificación de Imagen Radiográfica/instrumentación , Interpretación de Imagen Radiográfica Asistida por Computador/instrumentación , Sistemas de Información Radiológica/instrumentación , Sistemas de Información Radiológica/estadística & datos numéricos , Televisión/estadística & datos numéricos , Pantallas Intensificadoras de Rayos X/estadística & datos numéricos
8.
Radiol Med ; 81(5): 705-8, 1991 May.
Artículo en Italiano | MEDLINE | ID: mdl-2057602

RESUMEN

To date, the skeletal imaging capabilities of digital radiography with storage phosphors have been poorly investigated, and the diagnostic accuracy of this technique has not been thoroughly assessed. To evaluate the performance of storage phosphor digital radiography we compared 66 conventional and 66 digital radiographs of small abnormalities of the extremities (fractures, erosions, calcifications). Conventional images were obtained with a low-speed screen-film system while digital ones were acquired with high-resolution (5 lp/mm max) phosphors and laser-printed on a 8" x 10" film. Two experienced radiologists defined the gold standard (389 abnormalities) and four radiologists scored the findings (1,556 observations) on a five-point discrete scale. ROC analysis indicated film and storage radiography to be equally effective in the overall detection of abnormalities. No difference was found in the individual performances of the four readers, in the site subclasses (wrist, hand), and in the specific detection of fractures and erosions. Digital radiography proved to be superior to conventional radiography in the detection of calcifications in all sites and particularly in the wrist (p less than 0.05). Storage phosphor radiography may replace conventional radiography of the extremities without causing any significant decrease in diagnostic accuracy.


Asunto(s)
Enfermedades Óseas/diagnóstico por imagen , Mano/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Humanos , Curva ROC
10.
Radiol Med ; 78(5): 452-4, 1989 Nov.
Artículo en Italiano | MEDLINE | ID: mdl-2514443

RESUMEN

A digital radiographic system using storage phosphor detectors was employed in order to verify radiotherapy treatments with high energy photon beams (60Co-18 MV X-rays). The wide range linearity of the detectors and also the possibility of digital image post-processing allowed portal films to be obtained with sufficient contrast in all treatment techniques, particularly in the case of mantle fields. The use of digital radiography may become an easy and valuable procedure for therapy verification.


Asunto(s)
Radioisótopos de Cobalto/uso terapéutico , Interpretación de Imagen Asistida por Computador , Intensificación de Imagen Radiográfica/métodos , Radioterapia de Alta Energía , Algoritmos , Humanos , Mediciones Luminiscentes , Postura , Radioterapia Asistida por Computador
11.
Tumori ; 75(3): 226-8, 1989 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-2773075

RESUMEN

Alterations in size of the pineal body and melatonin secretion have been observed in cancer patients. The present study was carried out to evaluate pineal dimensions in a group of cancer patients and their relation to melatonin blood levels. The study included 70 oncologic patients. As controls, 41 patients with acute or chronic disease other than cancer entered the study. Melatonin serum levels were measured by radioimmunoassay on venous blood samples collected at 9:00 a.m. Pineal size was determined by brain CT scan, by considering the product of the two longest perpendicular diameters, multiplied by the thickness of the stratum. The volume of the pineal body was found to be enlarged in 12/70 (17%) cancer patients, and its mean value was significantly higher than that observed in controls. Melatonin levels were also significantly higher in oncologic patients than in controls. However, there was no correlation between melatonin levels and pineal size in cancer patients. Finally, cancer patients did not show a higher degree of pineal calcifications than controls. The clinical significance of pineal enlargement in cancer patients remains to be understood.


Asunto(s)
Neoplasias Encefálicas/secundario , Melatonina/sangre , Glándula Pineal/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Adulto , Anciano , Neoplasias Encefálicas/sangre , Neoplasias Encefálicas/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad
12.
Radiol Med ; 77(1-2): 44-50, 1989.
Artículo en Italiano | MEDLINE | ID: mdl-2928564

RESUMEN

The clinical utility was evaluated of a computed radiographic system in urography. The system (FCR 101, Philips Medical Systems, Inc., Shelton, CT) is based on a photo-stimulatable phosphor screen (imaging plate) for X-ray image detection and storage. The X-ray information recorded on the imaging plate is converted into digital from and processed by means of a computer. After processing is completed, the digitized image is reversed back to analogic signals, which modulate the intensity of a laser beam scanning the image on a single-emulsion film (Fuji CR 633). Two hundred IVP's were obtained in four groups, of 50 patients each, with normal azotemic values by rapid infusion of a low osmolality contrast medium (iopamidol 150 mgI/ml). While conventional radiographs were performed on the first group of patients with the injection of 0.6 gI/kg body weight of contrast medium, digital examinations were carried out, in the remaining three groups, with the injection of 0.6, 0.3 and 0.12 gI/kg, respectively. The digital images were processed with the "Abdomen-routine" program. A specific algorithm was implemented in order to reduce the excessive contrast resolution of the bladder, which is due to the characteristics of the nonionic contrast medium and enhanced by the reading program. The image details were evaluated by two observers and then statistically analyzed with nonparametric tests. Statistical analysis did not show any difference in the quality of digital and screen-film images. Image processing improved some inadequate images, by reducing the contrast resolution of the bladder, and allowed a better detection of some details. Low doses (0.3 gI/kg) of a low osmolality (150 mgI/kg) contrast medium were enough to obtain good images. Another biological advantage was obtained by a consistent radiation dose reduction (about 40%).


Asunto(s)
Intensificación de Imagen Radiográfica/instrumentación , Urografía/instrumentación , Adolescente , Adulto , Anciano , Estudios de Evaluación como Asunto , Humanos , Yopamidol , Persona de Mediana Edad , Control de Calidad , Dosis de Radiación , Película para Rayos X
13.
Radiol Med ; 76(6): 545-51, 1988 Dec.
Artículo en Italiano | MEDLINE | ID: mdl-3212237

RESUMEN

This paper briefly describes the technical features of a digital radiographic system based on the principle of scanning laser stimulated luminescence. Such aspects as the physics of the stimulable phosphor detector are dealt with, and image acquisition, processing, and hard-copy output. Automatic analysis of pixel histograms is described, in a qualitative way, together with contrast modifications and spatial filtering. Physical image characteristics are reported. The overall performance of digital radiography is examined, together with the current requirements and its eventual developments.


Asunto(s)
Intensificación de Imagen Radiográfica , Humanos , Rayos Láser , Intensificación de Imagen Radiográfica/instrumentación , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador , Pantallas Intensificadoras de Rayos X
15.
Radiol Med ; 73(3): 233-5, 1987 Mar.
Artículo en Italiano | MEDLINE | ID: mdl-3562925

RESUMEN

A specification on a digital radiography system which has been recently installed, based on the principle of scanning laser stimulated luminescence, is explained in short. We have just verified the possibility, among the many potential advantages, to produce good images at the lowest doses and insensitive to over and under exposure.


Asunto(s)
Intensificación de Imagen Radiográfica/instrumentación , Estudios de Evaluación como Asunto , Humanos , Tecnología Radiológica
18.
Radiol Med ; 68(11): 789-94, 1982 Nov.
Artículo en Italiano | MEDLINE | ID: mdl-7163526

RESUMEN

Totally 165 cases of chondromalacia patellae, taken from a series of 240 patients, are presented. The cause of the chondromalacia lies in imbalances, displacements, dysplasias of patellae and in femoro-tibial axial deviations. Overload is the constant intermediary between the different starting causes and the same final result. The precocity of the clinical-radiological diagnosis is essential for the timely carrying out of a corrective surgery, directed to remove the starting causes before the reversible chondromalacia develops into irreversible arthrosis.


Asunto(s)
Cartílago Articular , Articulación de la Rodilla , Rótula , Enfermedades de los Cartílagos/diagnóstico por imagen , Femenino , Humanos , Artropatías/diagnóstico por imagen , Artropatías/cirugía , Luxaciones Articulares/diagnóstico por imagen , Masculino , Radiografía
19.
Padiatr Padol ; 14(4): 415-21, 1979.
Artículo en Alemán | MEDLINE | ID: mdl-530729

RESUMEN

Obstruction of the superior renal calyces due to intrarenal vascular compressions is assumed on the basis of a characteristic sharply defined oblique filling defect with or without blunting of the fornices. Scintillation camera renography shows prolonged retention in the superior collecting system of the involved kidney. 11 out of 23 children had a symptomatology of recurrent hematuria, other origins of hematuria were excluded. 5 patients had urinary tract infection, the remaining 7 had normal urinary findings. Renal function was always normal. There is no correlation between severity of blunting and hematuria. In contrast to other studies which included only patients with blunting and ectasis even cases without blunting of the fornices have a clinical symptomatology. Deterioration of radiologic appearance and kidney function was not found. Any idiopathic hematuria should be investigated for calyceal obstruction. Uncomplicated cases require no therapy, long term follow-ups with regard to complications such as urinary tract infection and urolithiasis are indicated.


Asunto(s)
Cálices Renales/diagnóstico por imagen , Pelvis Renal/diagnóstico por imagen , Enfermedades Urológicas/diagnóstico por imagen , Adolescente , Niño , Preescolar , Femenino , Hematuria/etiología , Humanos , Masculino , Radiografía , Infecciones Urinarias/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA