Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
BMC Surg ; 23(1): 180, 2023 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-37386399

RESUMEN

BACKGROUND: For thirty years, the Harmonic scalpel has been used for precise dissection, sealing and transection. There are numerous meta-analyses on individual surgical procedures with Harmonic, but no overarching review covering all the areas. This umbrella review seeks to summarize the clinical results from the use of Harmonic across surgical fields and broadly quantify its effects on patient outcomes. METHODS: MEDLINE, EMBASE, and Cochrane Databases were searched for meta-analyses (MAs) of randomized controlled trials (RCTs) comparing Harmonic devices to conventional techniques or advanced bipolar (ABP) devices. For each procedure type, the most comprehensive MAs were evaluated. RCTs not already analysed in a MA were also included. Operating time, length of stay, intraoperative blood loss, drainage volume, pain, and overall complications were evaluated, and the methodological quality and certainty of evidence were assessed. RESULTS: Twenty-four systematic literature reviews were identified on colectomy, hemorrhoidectomy, gastrectomy, mastectomy, flap harvesting, cholecystectomy, thyroidectomy, tonsillectomy, and neck dissection. There were also 83 RCTs included. In every MA evaluated, Harmonic devices were associated with either statistically significant or numerical improvements in every outcome compared with conventional techniques; most MAs reported a reduction in operating time of ≥ 25 min. Harmonic versus ABP device MAs in colectomy and thyroidectomy showed no significant differences in outcomes. CONCLUSION: Across surgical procedures, Harmonic devices demonstrated improved patient outcomes for operating time, length of stay, intraoperative bleeding, drainage volume, pain, and overall complications compared to conventional techniques. Additional studies are required to assess differences between Harmonic and ABP devices.


Asunto(s)
Disección , Ultrasonido , Humanos , Disección/instrumentación
2.
ACS Omega ; 6(34): 22439-22446, 2021 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-34497933

RESUMEN

Colorimetric assays typically offer a rapid and convenient method to assess analytes that span healthcare monitoring to water quality testing. However, such tests can only provide qualitative results when employed in resource-limited settings or require bulky and expensive equipment such as lab spectrophotometers to allow quantitative measurements. In this paper, we report on the use of a handheld colorimeter to quantitatively determine the concentration of analytes in a manner that is independent of ambient lighting or initial sample color. The method combines the response of the sensor with first-principles modeling that better describes the nature of the assay compared to linear-in-parameters regression modeling that is typically performed in other studies. This method was successfully demonstrated using a number of colorimetric assays: (1) determination of solution pH using a universal indicator, (2) quantification of the DNase presence using a DNA-gold nanoparticle assay, and (3) quantification of the concentration of the antibiotic tetracycline using a cell-based assay.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA