Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
1.
Med. clín (Ed. impr.) ; 162(1): 22-28, ene. 2024. ilus, tab
Artículo en Español | IBECS | ID: ibc-229043

RESUMEN

El síndrome aórtico agudo agrupa distintas entidades que afectan a la pared aórtica y que tienen una presentación clínica común. En esta revisión se exponen aspectos relevantes sobre su epidemiología, presentación clínica, diagnóstico y estrategias de tratamiento. Además, se analiza la importancia de los equipos multidisciplinares y los centros de aorta en la atención y el pronóstico de los pacientes con síndrome aórtico agudo (AU)


Acute aortic syndrome embraces a group of heterogenous pathological entities involving the aortic wall with a common clinical profile. The current epidemiology, clinical presentation, diagnosis and treatment strategy are discussed in this review. Besides, the importance of multidisciplinary aortic teams, aortic centers and the implementation of an aortic code are emphasized (AU)


Asunto(s)
Humanos , Disección Aórtica
2.
Med Clin (Barc) ; 162(1): 22-28, 2024 01 12.
Artículo en Inglés, Español | MEDLINE | ID: mdl-37640592

RESUMEN

Acute aortic syndrome embraces a group of heterogenous pathological entities involving the aortic wall with a common clinical profile. The current epidemiology, clinical presentation, diagnosis and treatment strategy are discussed in this review. Besides, the importance of multidisciplinary aortic teams, aortic centers and the implementation of an aortic code are emphasized.


Asunto(s)
Sindrome Aortico Agudo , Enfermedades de la Aorta , Disección Aórtica , Humanos , Aorta , Hematoma , Enfermedades de la Aorta/diagnóstico , Enfermedades de la Aorta/terapia , Úlcera/diagnóstico , Enfermedad Aguda
4.
Rev Esp Cardiol (Engl Ed) ; 76(11): 872-880, 2023 Nov.
Artículo en Inglés, Español | MEDLINE | ID: mdl-36898524

RESUMEN

INTRODUCTION AND OBJECTIVES: No comparisons have been published yet regarding the newest iteration of balloon- and self-expandable transcatheter heart valves for the treatment of bicuspid aortic valve (BAV) stenosis. METHODS: Multicenter registry of consecutive patients with severe BAV stenosis treated with balloon-expandable transcatheter heart valves (Myval and SAPIEN 3 Ultra, S3U) or self-expanding Evolut PRO+(EP+). TriMatch analysis was carried out to minimize the impact of baseline differences. The primary endpoint of the study was 30-day device success, and the secondary endpoints were the composite and individual components of early safety at 30 days. RESULTS: A total of 360 patients (age 76.6±7.6 years, 71.9% males) were included: 122 Myval (33.9%), 129 S3U (35.8%), and 109 EP+(30.3%). The mean STS score was 3.6±1.9%. There were no cases of coronary artery occlusion, annulus rupture, aortic dissection, or procedural death. The primary endpoint of device success at 30 days was significantly higher in the Myval group (Myval: 100%; S3U: 87.5%; and EP+: 81.3%), mainly due to higher residual aortic gradients with S3U and greater≥moderate aortic regurgitation (AR) with EP+. No significant differences were found in the unadjusted rate of pacemaker implantation. CONCLUSIONS: In patients with BAV stenosis deemed unsuitable for surgery, Myval, S3U and EP+showed similar safety but balloon-expandable Myval had better gradients than S3U, and both balloon-expandable devices had lower residual AR than EP+, suggesting that, taking into consideration the patient-specific risks, any of these devices can be selected with optimal outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Anciano , Anciano de 80 o más Años , Femenino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Constricción Patológica , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Diseño de Prótesis
5.
Am J Cardiol ; 182: 1-7, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-36075756

RESUMEN

Although complete bioresorbable vascular scaffold (BVS) resorption has been demonstrated at 5-year follow-up, whether corresponding vasomotor function restoration occurs remains unknown. The objective was to simultaneously assess the structural healing response along with vasomotor responses at 5-year follow-up of BVS implantation. We studied consecutive patients treated with ABSORB-BVS at 5-year follow-up (n = 31), who were recruited from a multicenter registry and were contacted to undergo a research protocol-driven repeat coronary angiogram involving intracoronary optical coherence tomography (OCT) and invasive coronary endothelial function testing. Epicardial endothelium-dependent vasomotion was defined as any vasodilatation after intracoronary acetylcholine (ACh), whereas endothelium-independent vasomotion was defined as any vasodilatation after intracoronary nitroglycerine (NTG), using quantitative coronary angiography. The mean implantation time point was 60.5 ± 4.6 months. OCT imaging demonstrated complete scaffold resorption in all patients. New coronary lesions (stenosis >50%) were found in 5 patients (16.1%), 3 of them underwent ad hoc percutaneous revascularization (9.7%). Intracoronary ACh (27 patients) and NTG testing (30 patients) was performed. Quantitative coronary angiography analysis demonstrated vasoconstriction after ACh administration and lack of response to NTG in BVS segments (mean lumen diameter = 2.00 ± 0.61 mm at baseline vs 1.74 ± 0.70 mm post-ACh, p <0.001; 2.05 ± 0.54 mm at baseline vs 2.03 ± 0.50 mm post-NTG, p = 0.69). OCT lumen analysis demonstrated similar vasoconstrictive responses to ACh (mean lumen area = 5.31 ± 2.26 mm2 at baseline vs 5.12 ± 2.55 mm2 post-ACh, p = 0.007) but had a vasodilatory response to NTG (5.96 ± 2.35 mm2 at baseline vs 6.17 ± 2.55 mm2 post-NTG, p<0.001). In conclusion, complete ABSORB-BVS resorption was demonstrated at 5-year follow-up. However, this healing response was associated with endothelium-dependent vasomotor dysfunction within the BVS segment.


Asunto(s)
Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Implantes Absorbibles , Acetilcolina , Angiografía Coronaria , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Vasos Coronarios/cirugía , Everolimus , Estudios de Seguimiento , Humanos , Nitroglicerina/farmacología , Intervención Coronaria Percutánea/efectos adversos , Diseño de Prótesis , Tomografía de Coherencia Óptica , Resultado del Tratamiento
8.
J Investig Med High Impact Case Rep ; 9: 23247096211056491, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34879753

RESUMEN

Hypotension is the main finding in patients admitted to an intensive care unit (ICU) with the diagnosis of septic shock and it is related to worse outcomes. In these patients, several underlying causes of hypotension may co-exist, including vasoplegia, hypovolemia, drug-mediated venodilation, or myocardial dysfunction. Nowadays, echocardiography has been positioned as an essential tool in any ICU set to assess fluid status, ventricular ejection fraction, or any other myocardial complications. The high sympathetic tone in severely ill patients, in addition to high doses of adrenergic drugs often needed, may provoke a hypercontractile cardiac state. In the basis of our experience, we present a case of a patient with refractory septic shock and severe hemodynamic collapse, refractory to vasopressors with concomitant respiratory deterioration due to dynamic left ventricular outflow tract obstruction (LVOTO). Transesophageal echocardiography (TOE) was used to assess hemodynamic status and to guide treatment. A critical response to intravenous ß-blockers was seen, with a dramatic decrease in vasopressor dosage and respiratory support.


Asunto(s)
Choque Séptico , Humanos , Terapia Recuperativa , Choque Séptico/complicaciones , Choque Séptico/tratamiento farmacológico
9.
Med. clín (Ed. impr.) ; 157(1): 22-31, julio 2021. tab
Artículo en Español | IBECS | ID: ibc-211378

RESUMEN

La gripe se ha identificado como un factor desencadenante o agravante de los eventos cardiovasculares. Con el objetivo analizar el efecto de la vacunación antigripal en la enfermedad cardiovascular se realizó una búsqueda sistemática de estudios publicados entre 2009 y 2019. Se consideraron todos los trabajos que evaluaron el efecto de la vacunación frente a la gripe sobre eventos cardiovasculares y su evolución. Finalmente se incluyeron 30 de los 1.147 estudios identificados. Estos trabajos ponen de manifiesto el efecto protector de la vacuna antigripal tanto en el desarrollo de eventos cardiovasculares (infarto de miocardio, ictus, fibrilación auricular e insuficiencia cardíaca) como en el empeoramiento de estos procesos. Además, se demuestra que los pacientes vacunados presentan un menor riesgo de muerte por enfermedades cardiovasculares. La vacunación antigripal es, pues, una medida efectiva en la prevención de enfermedades cardiovasculares tanto en personas con enfermedad cardiovascular establecida como en aquellas sin patología previa. (AU)


Influenza infection has been identified as a triggering or exacerbating factor for cardiovascular events. To analyse the effect of influenza vaccination on cardiovascular disease, a systematic search of studies published between 2009-2019 was conducted. All the studies that evaluated the effect of vaccination against influenza on cardiovascular events and their outcome were considered. Finally, 30 of the 1147 identified studies were included. These studies show a protective effect of the influenza vaccine on the development of cardiovascular events (myocardial infarction, cerebrovascular accidents, atrial fibrillation, and heart failure) and on the worsening of these conditions. Furthermore, the data showed that vaccinated patients have a lower risk of death from cardiovascular pathologies. Influenza vaccination is therefore an effective measure in the prevention of cardiovascular diseases both in patients with established cardiovascular disease and in the population without previous coronary pathology. (AU)


Asunto(s)
Humanos , Enfermedades Cardiovasculares/etiología , Enfermedades Cardiovasculares/prevención & control , Vacunas contra la Influenza , Gripe Humana , Infarto del Miocardio/prevención & control
14.
Surg Endosc ; 34(3): 1200-1205, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31144121

RESUMEN

BACKGROUND AND GOALS: Missed adenomas are likely to be located in the proximal colon and failure to detect these lesions might explain the occurrence of a certain percentage of interval carcinomas. Though studies have demonstrated increased detection of significant neoplastic lesions in colonoscopic examinations where the withdrawal time is 6 min or more, there are no recommendations on how much time to spend in each colonic segment. The aim of the trial was to find ways to reduce the number of lesions missed in the proximal segments of the colon assessing the difference in adenoma detection rate (ADR) between two colonoscopic withdrawal timed techniques. STUDY: This was a randomized trial in a university hospital. Population was composed of patients referred for screening colonoscopy. The Main Outcome measurements was ADRs for patients subjected to a timed colonoscopy with specific withdrawal times, with special interest in the proximal colon, and implying a minimum of 2-min withdrawal delay in the cecum and right colon, a 1-min delay time in the transverse colon, and a minimum additional 3-min delay time in the left colon, as compared to a standard timed colonoscopy with free withdrawal delay time of at least 6 min. RESULTS: A total of 1160 patients were included. Eleven were initially excluded due to incomplete colonoscopies. Of the remaining 1149 patients, 573 were randomized to the group with fixed withdrawal times (Group A) and 576 to conventional withdrawal (Group B). Median age was 57 years (SD 6), a total of 634 (55.2%) were male patients and the mean withdrawal time was 7:05 min (SD 1 min). Seven hundred and eighty-one adenomas/serrated lesions were found in 470 patients (1.66 per patient), with 28 advanced lesions and 3 adenocarcinomas. Global ADR was 41% with no significant statistical differences between the two groups (42.1% vs 39.8%, p 0.43), respectively. A multivariate analysis showed clear relation between the finding of adenomas and higher BBPS ratings (Adjusted Odds Ratio [aOR] 0.92, p 0.05), age (aOR 1.03, p 0.01), male sex (aOR 1.51, p 0.001), and time of withdrawal (aOR 1.17, p 0.001), while no association was observed with either withdrawal technique (aOR 0.89, IC 95% 0.70-1.03, p 0.32). There was no statistical significant difference between the two groups concerning the finding of proximal lesions (cOR 0.93, CI 95% 0.71-1.20, p 0.56) (aOR 0.89, CI 95% 0.69-1.17, p 0.41) or serrated polyps (cOR 0.81, CI 95% 0.51-1.27, p 0.35) (aOR 0.81, IC 95% 0.51-1.28, p 0.36). CONCLUSIONS: Fixed withdrawal times did not prove to lead to an increase in the number of detected adenomas. Nevertheless, our study supports previous reports stating that longer withdrawal times are indeed associated with better proximal and distal adenoma detection.


Asunto(s)
Adenoma/diagnóstico , Colonoscopía/métodos , Neoplasias Colorrectales/diagnóstico , Adenocarcinoma/diagnóstico , Colon/patología , Pólipos del Colon/diagnóstico , Colonoscopios , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diagnóstico Erróneo/prevención & control , Análisis Multivariante , Oportunidad Relativa , Pólipos/patología
15.
Circ. cardiovasc. interv ; 12(11): 1-8, nov., 2019. ilus., graf., tab.
Artículo en Inglés | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1049984

RESUMEN

BACKGROUND: No data exist about the characteristics of infective endocarditis (IE) post-transcatheter aortic valve replacement (TAVR) according to transcatheter valve type. We aimed to determine the incidence, clinical characteristics, and outcomes of patients with IE post-TAVR treated with balloon-expandable valve (BEV) versus self-expanding valve (SEV) systems. METHODS: Data from the multicenter Infectious Endocarditis After TAVR International Registry was used to compare IE patients with BEV versus SEV. RESULTS: A total of 245 patients with IE post-TAVR were included (SEV, 47%; BEV, 53%). The timing between TAVR and IE was similar between groups (SEV, 5.5 [1.2-15] months versus BEV, 5.3 [1.7-11.4] months; P=0.89). Enterococcal IE was more frequent in the SEV group (36.5% versus 15.4%; P<0.01), and vegetation location differed according to valve type (stent frame, SEV, 18.6%; BEV, 6.9%; P=0.01; valve leaflet, SEV, 23.9%; BEV, 38.5%; P=0.01). BEV recipients had a higher rate of stroke/systemic embolism (20.0% versus 8.7%, adjusted OR: 2.46, 95% CI: 1.04-5.82, P=0.04). Surgical explant of the transcatheter valve (SEV, 8.7%; BEV, 13.8%; P=0.21), and in-hospital death at the time of IE episode (SEV, 35.6%; BEV, 37.7%; P=0.74) were similar between groups. After a mean follow-up of 13±12 months, 59.1% and 54.6% of the SEV and BEV recipients, respectively, had died (P=0.66). CONCLUSIONS: The characteristics of IE post-TAVR, including microorganism type, vegetation location, and embolic complications but not early or late mortality, differed according to valve type. These results may help to guide the diagnosis and management of IE and inform future research studies in the field. (AU)


Asunto(s)
Sistema de Registros , Incidencia , Endocarditis , Reemplazo de la Válvula Aórtica Transcatéter
17.
Medicina (B Aires) ; 78(6): 440-442, 2018.
Artículo en Español | MEDLINE | ID: mdl-30504112

RESUMEN

The condition of immunosuppressed increases the risk of cancer in kidney transplant patients, as compared to the general population. The best survival of inmunosupressed patients in recent years has turned both neoplasms and cardiovascular diseases into the main causes of morbidity and mortality. We present the case of a renal transplanted patient who developed an unusual form of mesenchymal tumor such as the aggressive angiomyxoma, four years after the implant and requiring wide surgical resection.


Asunto(s)
Inmunocompetencia , Trasplante de Riñón/efectos adversos , Mesenquimoma/etiología , Mixoma/etiología , Neoplasias Abdominales/etiología , Neoplasias Abdominales/patología , Neoplasias Abdominales/cirugía , Adulto , Humanos , Inmunosupresores/efectos adversos , Espectroscopía de Resonancia Magnética , Masculino , Mesenquimoma/patología , Mesenquimoma/cirugía , Mixoma/patología , Mixoma/cirugía , Factores de Riesgo
18.
Medicina (B.Aires) ; 78(6): 440-442, Dec. 2018. ilus
Artículo en Español | LILACS | ID: biblio-976143

RESUMEN

La condición de inmunosuprimido aumenta el riesgo de cáncer en trasplantados renales, en comparación a la población general. La mejor supervivencia de esta población en los últimos años ha convertido a las neoplasias y a la enfermedad cardiovascular en las principales causas de morbi-mortalidad. Presentamos el caso de un paciente trasplantado renal que desarrolló cuatro años después del trasplante una forma inusual de tumor mesenquimatoso, el angiomixoma agresivo, que requirió resección quirúrgica amplia.


The condition of immunosuppressed increases the risk of cancer in kidney transplant patients, as compared to the general population. The best survival of inmunosupressed patients in recent years has turned both neoplasms and cardiovascular diseases into the main causes of morbidity and mortality. We present the case of a renal transplanted patient who developed an unusual form of mesenchymal tumor such as the aggressive angiomyxoma, four years after the implant and requiring wide surgical resection.


Asunto(s)
Humanos , Masculino , Adulto , Trasplante de Riñón/efectos adversos , Inmunocompetencia , Mesenquimoma/etiología , Mixoma/etiología , Espectroscopía de Resonancia Magnética , Factores de Riesgo , Inmunosupresores/efectos adversos , Mesenquimoma/cirugía , Mesenquimoma/patología , Neoplasias Abdominales/cirugía , Neoplasias Abdominales/etiología , Neoplasias Abdominales/patología , Mixoma/cirugía , Mixoma/patología
19.
JACC Cardiovasc Interv ; 11(17): 1669-1679, 2018 09 10.
Artículo en Inglés | MEDLINE | ID: mdl-30190058

RESUMEN

OBJECTIVES: The authors aimed to determine the procedural learning curve and minimum annual institutional volumes associated with optimum clinical outcomes for transcatheter aortic valve replacement (TAVR). BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a complex procedure requiring significant training and experience for successful outcome. Despite increasing use of TAVR across institutions, limited information is available for its learning curve characteristics and minimum annual volumes required to optimize clinical outcomes. METHODS: The study collected data for patients at 16 centers participating in the international TAVR registry since initiation of the respective TAVR program. All cases were chronologically ordered into initial (1 to 75), early (76 to 150), intermediate (151 to 225), high (226 to 300), and very high (>300) experience operators for TAVR learning curve characterization. In addition, participating institutions were stratified by annual TAVR case volume into low-volume (<50), moderate-volume (50 to 100), and high-volume (>100) groups for comparative analysis. Procedural and 30-day clinical outcomes were collected and multivariate regression analysis performed for 30-day mortality and the early safety endpoint. RESULTS: A total of 3,403 patients comprised the study population. On multivariate analysis, all-cause mortality was significantly higher for initial (odds ratio [OR]: 3.83; 95% confidence interval [CI]: 1.93 to 7.60), early (OR: 2.41; 95% CI: 1.51 to 5.03), and intermediate (OR: 2.53; 95% CI: 1.19 to 5.40) experience groups compared with the very high experience operators. In addition, the early safety endpoint was significantly worse for all experience groups compared with the very high experience operators. Low annual volume (<50) TAVR institutions had significantly higher all-cause 30-day mortality (OR: 2.70; 95% CI: 1.44 to 5.07) and worse early safety endpoint (OR: 1.60; 95% CI: 1.17 to 2.17) compared with the moderate- and high-volume groups. There was no difference in patient outcomes between intermediate and high annual volume groups. CONCLUSIONS: TAVR procedures display important learning curve characteristics with both greater procedural safety and a lower mortality when performed by experienced operators. In addition, TAVR performed at low annual volume (<50 procedures) institutions is associated with decreased procedural safety and higher patient mortality. These findings have important implications for operator training and patient care at centers performing TAVR.


Asunto(s)
Competencia Clínica/normas , Hospitales de Alto Volumen/normas , Hospitales de Bajo Volumen/normas , Curva de Aprendizaje , Evaluación de Procesos y Resultados en Atención de Salud/normas , Cirujanos/normas , Reemplazo de la Válvula Aórtica Transcatéter/normas , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Seguridad del Paciente/normas , Complicaciones Posoperatorias/epidemiología , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Carga de Trabajo/normas
20.
JACC cardiovasc. interv ; 11(17): 1669-1679, Sept. 2018. graf, tab
Artículo en Inglés | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1247793

RESUMEN

OBJECTIVES: The authors aimed to determine the procedural learning curve and minimum annual institutional volumes associated with optimum clinical outcomes for transcatheter aortic valve replacement (TAVR).BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a complex procedure requiring significant training and experience for successful outcome. Despite increasing use of TAVR across institutions, limited information is available for its learning curve characteristics and minimum annual volumes required to optimize clinical outcomes. METHODS: The study collected data for patients at 16 centers participating in the international TAVR registry since initiation of the respective TAVR program. All cases were chronologically ordered into initial (1 to 75), early (76 to 150), intermediate (151 to 225), high (226 to 300), and very high (>300) experience operators for TAVR learning curve characterization. In addition, participating institutions were stratified by annual TAVR case volume into low-volume (<50), moderate-volume (50 to 100), and high-volume (>100) groups for comparative analysis. Procedural and 30-day clinical outcomes were collected and multivariate regression analysis performed for 30-day mortality and the early safety endpoint. RESULTS: A total of 3,403 patients comprised the study population. On multivariate analysis, all-cause mortality was significantly higher for initial (odds ratio [OR]: 3.83; 95% confidence interval [CI]: 1.93 to 7.60), early (OR: 2.41; 95%CI: 1.51 to 5.03), and intermediate (OR: 2.53; 95% CI: 1.19 to 5.40) experience groups compared with the very high experience operators. In addition, the early safety endpoint was significantly worse for all experience groups compared with the very high experience operators. Low annual volume (<50) TAVR institutions had significantly higher all-cause30-day mortality (OR: 2.70; 95% CI: 1.44 to 5.07) and worse early safety endpoint (OR: 1.60; 95% CI: 1.17 to 2.17) compared with the moderate- and high-volume groups. There was no difference in patient outcomes between intermediate and high annual volume groups. CONCLUSIONS: TAVR procedures display important learning curve characteristics with both greater procedural safety and a lower mortality when performed by experienced operators. In addition, TAVR performed at low annual volume (<50 procedures) institutions is associated with decreased procedural safety and higher patient mortality. These findings have important implications for operator training and patient care at centers performing TAVR.


Asunto(s)
Humanos , Femenino , Anciano de 80 o más Años , Curva de Aprendizaje , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...