Heart Rhythm O2 ; 5(5): 281-288, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38840765

RESUMEN

Background: Interventional cardiac resynchronization therapy (I-CRT) for left ventricular lead (LVL) placement works as a supplement to traditional (over-the-wire) cardiac resynchronization therapy (T-CRT). It has been argued that I-CRT is a time-consuming and complicated procedure. Objective: The purpose of this study was to investigate differences in procedure-related, perioperative, postoperative, and clinical endpoints between I-CRT and T-CRT. Methods: This single-center, retrospective, cohort study included all consecutive patients receiving a CRT-pacemaker/defibrillator between January 1, 2012, and August 31, 2018. Patients underwent T-CRT from January 1, 2012, to June 1, 2015, and I-CRT from January 1, 2016, to August 31, 2018. We obtained data from patient record files, fluoroscopic images, and the Danish Pacemaker and ICD Register. Data were analyzed using Wilcoxon rank-sum/linear regression for continuous variables and the Pearson χ2/Fisher exact for categorical variables. Results: Optimal LVL placement was achieved in 82.7% of the I-CRT group and 76.8% of the T-CRT group (P = .015). In the I-CRT group, 99.0% of LVLs were quadripolar vs 55.3% in the T-CRT group (P <.001). Two or more leads were used during the procedure in 0.7% and 10.5% of all cases in the I-CRT and T-CRT groups, respectively (P <.001). Total implantation time was 81.0 minutes in the I-CRT group and 83.0 minutes in the T-CRT group (P = .41). Time with catheters in the coronary sinus was 45.0 minutes for the I-CRT group vs 37.0 minutes in the T-CRT group, respectively (P <.001). Conclusion: I-CRT did not prolong total implantation time despite longer time with catheters in the coronary sinus. I-CRT allowed more optimal LVL placement, wider use of quadripolar leads, and use of fewer leads during the procedure.

2.
Eur Heart J ; 43(47): 4946-4956, 2022 12 14.
Artículo en Inglés | MEDLINE | ID: mdl-36263789

RESUMEN

AIMS: Cardiac implantable electronic device (CIED) infection is a severe complication to modern management of cardiac arrhythmias. The CIED type and the type of surgery are recognized as risk factors for CIED infections, but knowledge of patient-related risk factors is scarce. This study aimed to identify lifelong patient-related risk factors for CIED infections. METHODS AND RESULTS: Consecutive Danish patients undergoing a CIED implantation or reoperation between January 1996 and April 2018 were included. The cohort consisted of 84 429 patients undergoing 108 494 CIED surgeries with a combined follow-up of 458 257 CIED-years. A total of 1556 CIED explantations were classified as either pocket (n = 1022) or systemic CIED infection (n = 534). Data were cross-linked with records from the Danish National Patient Registry and the Danish National Prescription Registry. Using multiple-record and multiple-event per subject proportional hazard analysis, specific patient-related risk factors were identified but with several variations amongst the subtypes of CIED infection. CIED reoperations were associated with the highest risk of pocket CIED infection but also CIED type, young age, and prior valvular surgery [hazard ratio (HR): 1.62, 95% confidence interval (CI): 1.29-2.04]. Severe renal insufficiency/dialysis (HR: 2.40, 95% CI: 1.65-3.49), dermatitis (HR: 2.80, 95% CI: 1.92-4.05), and prior valvular surgery (HR: 2.09, 95% CI: 1.59-2.75) were associated with the highest risk of systemic CIED infections. Congestive heart failure, ischaemic heart disease, malignancy, chronic obstructive pulmonary disease, and temporary pacing were not significant at multivariate analysis. CONCLUSION: Specific comorbidities and surgical procedures were associated with a higher risk of CIED infections but with variations amongst pocket and systemic CIED infection. Pocket CIED infections were associated with CIED reoperations, young age and more complex type of CIED, whereas systemic CIED infections were associated with risk factors predisposing to bacteraemia.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Infecciones Relacionadas con Prótesis , Humanos , Marcapaso Artificial/efectos adversos , Desfibriladores Implantables/efectos adversos , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/etiología , Incidencia , Factores de Riesgo , Electrónica , Dinamarca/epidemiología , Estudios Retrospectivos
3.
Circ Arrhythm Electrophysiol ; 15(4): e010688, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35357203

RESUMEN

BACKGROUND: Familial ST-depression syndrome is an inherited disease characterized by persistent, nonischemic ST-deviations, and risk of arrhythmias and heart failure. We aimed at further characterizing the ECG, arrhythmias, and structural characteristics associated with this novel syndrome. METHODS: Retrospective analysis of data from consecutive families with familial ST-depression Syndrome in Denmark. ECG features, prevalence and type of arrhythmias, occurrence of systolic dysfunction, and medium-term outcome were analyzed. RESULTS: Forty affected individuals (43% men; mean age at diagnosis 49.1 years) from 14 apparently unrelated families with ≥2 affected members were included. Autosomal dominant inheritance was observed in all families. The ECG phenotype seemed to develop in prepuberty and the ST-deviations were persistent and most pronounced in leads V4/V5/II, respectively. Serial ECG analyses showed stable to slow progression of the ECG phenotype. Exercise accentuated the ST-deviations with a maximum difference between rest/stress (mean) of -117 µV in lead V5. During a mean follow-up of 9.3±7.1 years 5 (13%) patients developed sustained ventricular arrhythmias or (aborted) sudden cardiac death, 10 (25%) developed atrial fibrillation, 2 (5%) other supraventricular arrhythmias, and 10 (25%) were diagnosed with left ventricular ejection fraction ≤50%. The ventricular arrhythmias were polymorphic with relatively short-coupled premature ventricular contractions at onset (300-360 ms); no QT prolongation was observed. Seven patients had at least one catheter ablation; 5 for supraventricular arrhythmias and 2 for ventricular arrhythmias. Males experienced more arrhythmic end points than females (P<0.01). CONCLUSIONS: The familial ST-depression ECG phenotype is stable to slowly progressive after medium-term follow-up. Clinically, both supra- and ventricular arrhythmias are common; as are some degree of left ventricular systolic dysfunction. Familial ST-depression represent a novel inherited cause of polymorphic ventricular tachycardia.


Asunto(s)
Depresión , Complejos Prematuros Ventriculares , Electrocardiografía , Femenino , Humanos , Masculino , Estudios Retrospectivos , Volumen Sistólico , Función Ventricular Izquierda
4.
Heart Rhythm ; 19(6): 901-908, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35124230

RESUMEN

BACKGROUND: Device-related infection (DRI) is a severe complication of treatment with cardiac implantable electronic devices. Identification of the causative pathogen is essential for optimal treatment, but conventional methods often are inadequate. OBJECTIVE: The purpose of this study was to improve microbiological diagnosis in DRI using sonication and next-generation sequencing analysis. The primary objective was identification of causative pathogens. The secondary objective was estimation of the sensitivity of different microbiological methods in detecting the causative pathogen. METHODS: Consecutive patients with clinical signs of DRI between October 2016 and January 2019 from 3 tertiary centers in Denmark were included in the study. Patients underwent a diagnostic approach, including blood cultures and perioperative collection of microbiological samples (pocket swab, pocket tissue biopsies, generator, and leads). Conventional culturing was performed, and device components were sonicated and examined with an amplicon-based metagenomic analysis using next-generation sequencing. The results were compared with a reference standard-identified causative pathogen. RESULTS: In 110 patients with clinical signs of pocket (n = 50) or systemic DRI (n = 60), we collected 109 pocket swabs, 220 pocket tissue biopsies, 106 generators, 235 leads, and a minimum 1 set of blood cultures from 102 patients. Combining all findings, we identified the causative pathogen in 95% of cases, irrespective of DRI type. The usability of each microbiological method differed between DRI types. In pocket DRI, next-generation sequencing analysis of generators achieved sensitivity of 90%. For systemic DRI, blood cultures reached sensitivity of 93%. CONCLUSION: Using a strategy including sonication and next-generation sequencing, we identified the causative pathogen in 95% of DRI. Sensitivity of microbiological methods differed according to the type of DRI.


Asunto(s)
Desfibriladores Implantables , Cardiopatías , Marcapaso Artificial , Infecciones Relacionadas con Prótesis , Desfibriladores Implantables/efectos adversos , Desfibriladores Implantables/microbiología , Electrónica , Secuenciación de Nucleótidos de Alto Rendimiento , Humanos , Marcapaso Artificial/efectos adversos , Marcapaso Artificial/microbiología , Infecciones Relacionadas con Prótesis/diagnóstico , Sonicación/métodos
5.
Int J Cardiovasc Imaging ; 35(7): 1277-1286, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30923993

RESUMEN

This study aimed to investigate different echocardiographic parameters for predicting atrial fibrillation (AF) in patients with transient ischemic attack (TIA). Echocardiography was performed in 110 patients (median age 65.8 years, 53% males) with TIA and no history of stroke or AF. All patients underwent monitoring with ECG and 72 h Holter-monitoring, and if no AF was found, an insertable cardiac monitor (ICM) was implanted and patients were followed for a median of 2.2 years. AF was found in 14 patients: five with Holter-monitoring and nine with ICM. AF patients had significantly larger left atrial (LA) volumes indexes compared to patients without AF (26.7 vs. 33.7 ml/m2, P = 0.03 for 2D images and 26.5 vs. 33.5 ml/m2, P = 0.0008 for 3D images). Patients with AF also had depressed LA function assessed with LA emptying fraction measured with 2D echocardiography (46.3 vs. 57.3%, P = 0.005 for patients with and without AF, respectively). Patients with AF also had depressed left ventricular (LV) function compared to patients without AF. LV ejection fraction was 55 versus 61%, P = 0.04 in patients with and without AF, respectively. LV global longitudinal strain (absolute value) was 16.7 in patients with AF compared to 21.2 in patients without AF (P = 0.001). Echocardiographic measurements of LA and LV size and function can noninvasively predict AF in patients with TIA and could potentially be used to guide AF monitoring strategy.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Función del Atrio Izquierdo , Ecocardiografía Doppler , Atrios Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Ataque Isquémico Transitorio/complicaciones , Función Ventricular Izquierda , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/etiología , Fibrilación Atrial/fisiopatología , Electrocardiografía Ambulatoria , Femenino , Atrios Cardíacos/fisiopatología , Ventrículos Cardíacos/fisiopatología , Humanos , Ataque Isquémico Transitorio/diagnóstico , Ataque Isquémico Transitorio/fisiopatología , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Estudios Prospectivos , Factores de Riesgo , Volumen Sistólico , Factores de Tiempo , Adulto Joven