Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Cardiovasc Intervent Radiol ; 30(2): 222-5, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17131210

RESUMEN

PURPOSE: To determine the safety and efficacy of conversion of non-tunneled (temporary) catheters to tunneled catheters in hemodialysis patients. METHODS: A retrospective review of 112 consecutive conversions in 111 patients was performed over a period of 4 years. Fourteen patients were lost to follow-up. The remaining 97 patients had clinical follow-up. Temporary catheters were converted to tunneled catheters utilizing the same internal jugular venotomy sites and a modified over-the-wire technique with use of a peel-away sheath . Follow-up clinical data were reviewed. RESULTS: Technical success was achieved in all 112 procedures. None of the 97 patients with follow-up suffered early infection within 30 days. The total number of follow-up catheter days was 13,659 (range 2-790). Cases of confirmed and suspected bacteremia requiring catheter removal occurred at a frequency of 0.10 per 100 catheter days. Suspected catheter infection treated with antibiotics but not requiring catheter intervention occurred at a frequency of 0.04 per 100 catheter days. Frequency of all suspected or confirmed infections was 0.14 per 100 catheter days. Catheter interventions as a result of poor blood flow, inadvertent removal, catheter fracture, or kinking occurred at a rate of 0.18 per 100 catheter days. Life table analysis revealed primary patency rates of 86%, 64%, and 39% at 30 days, 90 days, and 180 days, respectively. CONCLUSION: Conversion of temporary catheters to tunneled catheters using the pre-existing venotomy sites is safe and has low rates of infection and malfunction. These rates are comparable to previously published rates for tunneled catheters placed de novo and tunneled catheter exchanges.


Asunto(s)
Catéteres de Permanencia , Diálisis Renal/instrumentación , Adulto , Anciano , Anciano de 80 o más Años , Antibacterianos/uso terapéutico , Bacteriemia/tratamiento farmacológico , Bacteriemia/etiología , Catéteres de Permanencia/efectos adversos , Catéteres de Permanencia/microbiología , Remoción de Dispositivos , Seguridad de Equipos , Femenino , Estudios de Seguimiento , Oclusión de Injerto Vascular/etiología , Oclusión de Injerto Vascular/fisiopatología , Humanos , Venas Yugulares/fisiopatología , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Falla de Prótesis , Infecciones Relacionadas con Prótesis/tratamiento farmacológico , Infecciones Relacionadas con Prótesis/etiología , Proyectos de Investigación , Estudios Retrospectivos , Infecciones Estafilocócicas/complicaciones , Infecciones Estafilocócicas/tratamiento farmacológico , Infecciones Estafilocócicas/microbiología , Resultado del Tratamiento , Grado de Desobstrucción Vascular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA