1.
Future Cardiol ; : 1-6, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38975696

RESUMEN

One of the most common complications of tricuspid valve replacement is atrioventricular block (AVB), often requiring permanent pacing. The endocardial pacemaker lead, placed in the right ventricle, may sometimes interfere with the implanted prosthesis, causing its early dysfunction and the need for alternative sites of pacing. To the best of our knowledge, we present the first case of a successful combined percutaneous procedure consisting of the implantation of two leads in the coronary sinus for univentricular bifocal pacing and a transcatheter tricuspid valve-in-valve implantation in a young patient with severe dysfunction of the tricuspid bioprosthesis, requiring permanent pacing for a postsurgical complete atrioventricular block.


Tricuspid valve replacement with surgery can often lead to cardiac rhythm disorders requiring a permanent pacemaker. This device may occasionally damage the tricuspid prosthesis. We present the first case of a combined procedure of tricuspid valve replacement and device implantation distant from the prosthesis without the need for a surgical approach in a young patient with severe tricuspid prosthesis malfunctioning and permanent pacing.

2.
Cardiovasc Digit Health J ; 5(3): 164-172, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38989039

RESUMEN

Background: Achieving a high biventricular pacing percentage (BiV%) is crucial for optimizing outcomes in cardiac resynchronization therapy (CRT). The HeartLogic index, a multiparametric heart failure (HF) risk score, incorporates implantable cardioverter-defibrillator (ICD)-measured variables and has demonstrated its predictive ability for impending HF decompensation. Objective: This study aimed to investigate the relationship between daily BiV% in CRT ICD patients and their HF status, assessed using the HeartLogic algorithm. Methods: The HeartLogic algorithm was activated in 306 patients across 26 centers, with a median follow-up of 26 months (25th-75th percentile: 15-37). Results: During the follow-up period, 619 HeartLogic alerts were recorded in 186 patients. Overall, daily values associated with the best clinical status (highest first heart sound, intrathoracic impedance, patient activity; lowest combined index, third heart sound, respiration rate, night heart rate) were associated with a BiV% exceeding 99%. We identified 455 instances of BiV% dropping below 98% after consistent pacing periods. Longer episodes of reduced BiV% (hazard ratio: 2.68; 95% CI: 1.02-9.72; P = .045) and lower BiV% (hazard ratio: 3.97; 95% CI: 1.74-9.06; P=.001) were linked to a higher risk of HeartLogic alerts. BiV% drops exceeding 7 days predicted alerts with 90% sensitivity (95% CI [74%-98%]) and 55% specificity (95% CI [51%-60%]), while BiV% ≤96% predicted alerts with 74% sensitivity (95% CI [55%-88%]) and 81% specificity (95% CI [77%-85%]). Conclusion: A clear correlation was observed between reduced daily BiV% and worsening clinical conditions, as indicated by the HeartLogic index. Importantly, even minor reductions in pacing percentage and duration were associated with an increased risk of HF alerts.

3.
Biomedicines ; 12(6)2024 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-38927500

RESUMEN

Arrhythmic risk stratification in patients with Lamin A/C gene (LMNA)-related cardiomyopathy influences clinical decisions. An implantable cardioverter defibrillator (ICD) should be considered in patients with an estimated 5-year risk of malignant ventricular arrhythmia (MVA) of ≥10%. The risk prediction score for MVA includes non-missense LMNA mutations, despite their role as an established risk factor for sudden cardiac death (SCD) has been questioned in several studies. The purpose of this study is to investigate cardiac features and find gene-phenotype correlations that would contribute to the evidence on the prognostic implications of non-missense vs. missense mutations in a cohort of LMNA mutant patients. An observational, prospective study was conducted in which 54 patients positive for a Lamin A/C mutation were enrolled, and 20 probands (37%) were included. The median age at first clinical manifestation was 41 (IQR 19) years. The median follow-up was 8 years (IQR 8). The type of LMNA gene mutation was distributed as follows: missense in 26 patients (48%), non-frameshift insertions in 16 (30%), frameshift deletions in 5 (9%), and nonsense in 7 (13%). Among the missense mutation carriers, two (8%) died and four (15%) were admitted onto the heart transplant list or underwent transplantation, with a major adverse cardiovascular event (MACE) rate of 35%. No statistically significant differences in MACE prevalence were identified according to the missense and non-missense mutation groups (p value = 0.847). Our data shift the spotlight on this considerable topic and could suggest that some missense mutations may deserve attention regarding SCD risk stratification in real-world clinical settings.

4.
J Clin Med ; 13(9)2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38731153

RESUMEN

Cardiomyopathies (CMPs) are a group of myocardial disorders that are characterized by structural and functional abnormalities of the heart muscle. These abnormalities occur in the absence of coronary artery disease (CAD), hypertension, valvular disease, and congenital heart disease. CMPs are an increasingly important topic in the field of cardiovascular diseases due to the complexity of their diagnosis and management. In 2023, the ESC guidelines on cardiomyopathies were first published, marking significant progress in the field. The growth of techniques such as cardiac magnetic resonance imaging (CMR) and genetics has been fueled by the development of multimodal imaging approaches. For the diagnosis of CMPs, a multimodal imaging approach, including CMR, is recommended. CMR has become the standard for non-invasive analysis of cardiac morphology and myocardial function. This document provides an overview of the role of CMR in CMPs, with a focus on tissue mapping. CMR enables the characterization of myocardial tissues and the assessment of cardiac functions. CMR sequences and techniques, such as late gadolinium enhancement (LGE) and parametric mapping, provide detailed information on tissue composition, fibrosis, edema, and myocardial perfusion. These techniques offer valuable insights for early diagnosis, prognostic evaluation, and therapeutic guidance of CMPs. The use of quantitative CMR markers enables personalized treatment plans, improving overall patient outcomes. This review aims to serve as a guide for the use of these new tools in clinical practice.

5.
Heart Rhythm ; 2024 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-38493989

RESUMEN

BACKGROUND: Atrial high-rate episodes (AHREs) are frequent in patients with cardiac implantable electronic devices. A decrease in device-detected P-wave amplitude may be an indicator of periods of increased risk of AHRE. OBJECTIVE: The objective of this study was to assess the association between P-wave amplitude and AHRE incidence. METHODS: Remote monitoring data from 2579 patients with no history of atrial fibrillation (23% pacemakers and 77% implantable cardioverter-defibrillators, of which 40% provided cardiac resynchronization therapy) were used to calculate the mean P-wave amplitude during 1 month after implantation. The association with AHRE incidence according to 4 strata of daily burden duration (≥15 minutes, ≥6 hours, ≥24 hours, ≥7 days) was investigated by adjusting the hazard ratio with the CHA2DS2-VASc score. RESULTS: The adjusted hazard ratio for 1-mV lower mean P-wave amplitude during the first month increased from 1.10 (95% confidence interval [CI], 1.05-1.15; P < .001) to 1.18 (CI, 1.09-1.28; P < .001) with AHRE duration strata from ≥15 minutes to ≥7 days independent of the CHA2DS2-VASc score. Of 871 patients with AHREs, those with 1-month P-wave amplitude <2.45 mV had an adjusted hazard ratio of 1.51 (CI, 1.19-1.91; P = .001) for progression of AHREs from ≥15 minutes to ≥7 days compared with those with 1-month P-wave amplitude ≥2.45 mV. Device-detected P-wave amplitudes decreased linearly during the 1 year before the first AHRE by 7.3% (CI, 5.1%-9.5%; P < .001 vs patients without AHRE). CONCLUSION: Device-detected P-wave amplitudes <2.45 mV were associated with an increased risk of AHRE onset and progression to persistent forms of AHRE independent of the patient's risk profile.

6.
Telemed J E Health ; 30(5): 1499-1503, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38294864

RESUMEN

Telemedicine and remote monitoring devices, including implantable loop recorders (ILR), are increasingly adopted in the cardiologic setting. These are valuable tools in the arrhythmic stratification of patients at risk of sudden cardiac death, providing a tailored therapeutic management to prevent lethal arrhythmias. We report a case of an asymptomatic 18-year-old boy with a family history of syncope and cardiac arrest, who had a diagnosis of Brugada syndrome with an inducible type 1 pattern and carrier of a missense mutation of the SCN5A gene. In light of the risk factors, although not recommended by current guidelines, we decided to proceed with the implantation of an ILR with remote monitoring service. A few months later, an episode of asymptomatic sustained polymorphic ventricular tachycardia was promptly observed by the remote monitoring, leading to a timely implantation of a subcutaneous cardiac implantable defibrillator.


Asunto(s)
Síndrome de Brugada , Desfibriladores Implantables , Telemedicina , Humanos , Masculino , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/genética , Síndrome de Brugada/terapia , Adolescente , Telemedicina/métodos , Medición de Riesgo/métodos , Canal de Sodio Activado por Voltaje NAV1.5/genética , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Electrocardiografía , Electrocardiografía Ambulatoria/instrumentación , Electrocardiografía Ambulatoria/métodos , Mutación Missense , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/etiología
7.
Future Cardiol ; 20(1): 21-25, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38223918

RESUMEN

Aim: Micra AV represents a leadless endocardial pacing system able to detect atrial contractions providing atrioventricular synchrony. A reduction of myocardial contractility may be detected in case of first-degree atrioventricular block (AVB). Materials & methods: In six patients with first-degree AVB (PQ interval ≥220 msec) was evaluated the left ventricle global longitudinal strain (LV GLS) by speckle tracking (ST) echocardiography during single-lead atrial sensing ventricular pacing (VDD) stimulation as compared with spontaneous rhythm (SR), 24-48 h after Micra AV implantation. Results: A statistically significant difference between the two modalities was observed (LV GLS during SR: -14.7% [interquartile range (IQR) 5.5], LV GLS during VDD pacing: -16.1% [IQR 5.2]; p value = 0.041). Conclusion: Our preliminary results suggest an improvement of myocardial contractility with VDD pacing as compared with SR.


What is this article about? The Micra AV is an electronic device placed in the heart chambers capable to supply the electrical activity of the heart. A reduction of cardiac contractility may be observed in patients with electrical disorders of the heart. What were the results? In six patients affected by electrical cardiac disorders, we observed an improvement of cardiac contractility using Micra AV as compared with the spontaneous electrical activity of the heart. What do the results of the study mean? The results of this study suggest that in patients carrying this electronic device should be preferred a specific modality of activation of the device as compared with the spontaneous electrical activity of the heart in order to improve the contractility of the cardiac walls.


Asunto(s)
Bloqueo Atrioventricular , Defectos de los Tabiques Cardíacos , Marcapaso Artificial , Humanos , Ventrículos Cardíacos/diagnóstico por imagen , Estimulación Cardíaca Artificial/métodos , Bloqueo Atrioventricular/terapia , Atrios Cardíacos/diagnóstico por imagen
8.
Heart Rhythm ; 21(5): 555-561, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38242222

RESUMEN

BACKGROUND: There are limited real-world data on the extended prognosis of patients with drug-induced type 1 Brugada electrocardiogram (ECG). OBJECTIVE: We assessed the clinical outcomes and predictors of life-threatening arrhythmias in patients with drug-induced type 1 Brugada ECG. METHODS: This multicenter retrospective study, conducted at 21 Italian and Swiss hospitals from July 1997 to May 2021, included consecutive patients with drug-induced type 1 ECG. The primary outcome, a composite of appropriate ICD therapies and sudden cardiac death, was assessed along with the clinical predictors of these events. RESULTS: A total of 606 patients (mean age 49.7 ± 14.7 years; 423 [69.8%] men) were followed for a median of 60.3 months (interquartile range 23.0-122.4 months). Nineteen patients (3.1%) experienced life-threatening arrhythmias, with a median annual event rate of 0.5% over 5 years and 0.25% over 10 years. The SCN5A mutation was the only predictor of the primary outcome (hazard ratio 4.54; P = .002), whereas a trend was observed for unexplained syncope (hazard ratio 3.85; P = .05). In patients who were asymptomatic at presentation, the median annual rate of life-threatening arrhythmias is 0.24% over 5 years and increases to 1.2% if they have inducible ventricular fibrillation during programmed ventricular stimulation. CONCLUSION: In patients with drug-induced type 1 Brugada ECG, the annual risk of life-threatening arrhythmias is low, with the SCN5A mutation as the only independent predictor. Unexplained syncope correlated with worse clinical outcomes. Ventricular fibrillation inducibility at programmed ventricular stimulation significantly increases the median annual rate of life-threatening arrhythmias from 0.24% to 1.2% over 5 years.


Asunto(s)
Síndrome de Brugada , Electrocardiografía , Sistema de Registros , Humanos , Masculino , Síndrome de Brugada/fisiopatología , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/epidemiología , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Pronóstico , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Italia/epidemiología , Estudios de Seguimiento , Desfibriladores Implantables , Suiza/epidemiología , Factores de Tiempo , Tasa de Supervivencia/tendencias , Adulto
9.
Pacing Clin Electrophysiol ; 47(2): 256-259, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-37208974

RESUMEN

INTRODUCTION: Micra AV Transcatheter Pacing System (TPS) represents an innovative second-generation leadless pacemaker which represents an effective alternative to conventional devices in selected cases. Intrinsic malfunctions of these devices are rare, requiring sometimes their retrieval. When performed in experienced centers, this procedure is safe. CASE PRESENTATION: We describe a case of sudden battery malfunction of a Micra AV TPS, which required the extraction and the placement of a new pacing system in the right ventricle. DISCUSSION: This case, which has never been reported, highlights the need to a careful fluoroscopic evaluation and the usefulness of remote monitoring.


Asunto(s)
Arritmias Cardíacas , Marcapaso Artificial , Humanos , Resultado del Tratamiento , Diseño de Equipo , Marcapaso Artificial/efectos adversos , Estimulación Cardíaca Artificial
10.
J Clin Med ; 12(24)2023 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-38137821

RESUMEN

Non-ischemic dilated cardiomyopathy (DCM) is a disease characterized by left ventricular dilation and systolic dysfunction. Patients with DCM are at higher risk for ventricular arrhythmias and sudden cardiac death (SCD). According to current international guidelines, left ventricular ejection fraction (LVEF) ≤ 35% represents the main indication for prophylactic implantable cardioverter defibrillator (ICD) implantation in patients with DCM. However, LVEF lacks sensitivity and specificity as a risk marker for SCD. It has been seen that the majority of patients with DCM do not actually benefit from the ICD implantation and, on the contrary, that many patients at risk of SCD are not identified as they have preserved or mildly depressed LVEF. Therefore, the use of LVEF as unique decision parameter does not maximize the benefit of ICD therapy. Multiple risk factors used in combination could likely predict SCD risk better than any single risk parameter. Several predictors have been proposed including genetic variants, electric indexes, and volumetric parameters of LV. Cardiac magnetic resonance (CMR) can improve risk stratification thanks to tissue characterization sequences such as LGE sequence, parametric mapping, and feature tracking. This review evaluates the role of CMR as a risk stratification tool in DCM patients referred for ICD.

11.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37656991

RESUMEN

AIMS: The HeartLogic Index combines data from multiple implantable cardioverter defibrillators (ICDs) sensors and has been shown to accurately stratify patients at risk of heart failure (HF) events. We evaluated and compared the performance of this algorithm during sinus rhythm and during long-lasting atrial fibrillation (AF). METHODS AND RESULTS: HeartLogic was activated in 568 ICD patients from 26 centres. We found periods of ≥30 consecutive days with an atrial high-rate episode (AHRE) burden <1 h/day and periods with an AHRE burden ≥20 h/day. We then identified patients who met both criteria during the follow-up (AHRE group, n = 53), to allow pairwise comparison of periods. For control purposes, we identified patients with an AHRE burden <1 h throughout their follow-up and implemented 2:1 propensity score matching vs. the AHRE group (matched non-AHRE group, n = 106). In the AHRE group, the rate of alerts was 1.2 [95% confidence interval (CI): 1.0-1.5]/patient-year during periods with an AHRE burden <1 h/day and 2.0 (95% CI: 1.5-2.6)/patient-year during periods with an AHRE-burden ≥20 h/day (P = 0.004). The rate of HF hospitalizations was 0.34 (95% CI: 0.15-0.69)/patient-year during IN-alert periods and 0.06 (95% CI: 0.02-0.14)/patient-year during OUT-of-alert periods (P < 0.001). The IN/OUT-of-alert state incidence rate ratio of HF hospitalizations was 8.59 (95% CI: 1.67-55.31) during periods with an AHRE burden <1 h/day and 2.70 (95% CI: 1.01-28.33) during periods with an AHRE burden ≥20 h/day. In the matched non-AHRE group, the rate of HF hospitalizations was 0.29 (95% CI: 0.12-0.60)/patient-year during IN-alert periods and 0.04 (95% CI: 0.02-0.08)/patient-year during OUT-of-alert periods (P < 0.001). The incidence rate ratio was 7.11 (95% CI: 2.19-22.44). CONCLUSION: Patients received more alerts during periods of AF. The ability of the algorithm to identify increased risk of HF events was confirmed during AF, despite a lower IN/OUT-of-alert incidence rate ratio in comparison with non-AF periods and non-AF patients. CLINICAL TRIAL REGISTRATION: http://clinicaltrials.gov/Identifier: NCT02275637.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Algoritmos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/terapia , Atrios Cardíacos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia
12.
ESC Heart Fail ; 10(4): 2469-2478, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37278122

RESUMEN

AIMS: The HeartLogic algorithm combines multiple implantable defibrillator (ICD) sensor data and has proved to be a sensitive and timely predictor of impending heart failure (HF) decompensation in cardiac resynchronization therapy (CRT-D) patients. We evaluated the performance of this algorithm in non-CRT ICD patients and in the presence of co-morbidities. METHODS AND RESULTS: The HeartLogic feature was activated in 568 ICD patients (410 with CRT-D) from 26 centres. The median follow-up was 26 months [25th-75th percentile: 16-37]. During follow-up, 97 hospitalizations were reported (53 cardiovascular) and 55 patients died. We recorded 1200 HeartLogic alerts in 370 patients. Overall, the time IN the alert state was 13% of the total observation period. The rate of cardiovascular hospitalizations or death was 0.48/patient-year (95% CI: 0.37-0.60) with the HeartLogic IN the alert state and 0.04/patient-year (95% CI: 0.03-0.05) OUT of the alert state, with an incidence rate ratio of 13.35 (95% CI: 8.83-20.51, P < 0.001). Among patient characteristics, atrial fibrillation (AF) on implantation (HR: 1.62, 95% CI: 1.27-2.07, P < 0.001) and chronic kidney disease (CKD) (HR: 1.53, 95% CI: 1.21-1.93, P < 0.001) independently predicted alerts. HeartLogic alerts were not associated with CRT-D versus ICD implantation (HR: 1.03, 95% CI: 0.82-1.30, P = 0.775). Comparisons of the clinical event rates in the IN alert state with those in the OUT of alert state yielded incidence rate ratios ranging from 9.72 to 14.54 (all P < 0.001) in all groups of patients stratified by: CRT-D/ICD, AF/non-AF, and CKD/non-CKD. After multivariate correction, the occurrence of alerts was associated with cardiovascular hospitalization or death (HR: 1.92, 95% CI: 1.05-3.51, P = 0.036). CONCLUSIONS: The burden of HeartLogic alerts was similar between CRT-D and ICD patients, while patients with AF and CKD seemed more exposed to alerts. Nonetheless, the ability of the HeartLogic algorithm to identify periods of significantly increased risk of clinical events was confirmed, regardless of the type of device and the presence of AF or CKD.


Asunto(s)
Fibrilación Atrial , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia , Fibrilación Atrial/etiología , Algoritmos , Morbilidad
13.
Europace ; 25(4): 1467-1474, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-36881780

RESUMEN

AIMS: Patients with atrial fibrillation frequently experience sleep disorder breathing, and both conditions are highly prevalent in presence of heart failure (HF). We explored the association between the combination of an HF and a sleep apnoea (SA) index and the incidence of atrial high-rate events (AHRE) in patients with implantable defibrillators (ICDs). METHODS AND RESULTS: Data were prospectively collected from 411 consecutive HF patients with ICD. The IN-alert HF state was measured by the multi-sensor HeartLogic Index (>16), and the ICD-measured Respiratory Disturbance Index (RDI) was computed to identify severe SA. The endpoints were as follows: daily AHRE burden of ≥5 min, ≥6 h, and ≥23 h. During a median follow-up of 26 months, the time IN-alert HF state was 13% of the total observation period. The RDI value was ≥30 episodes/h (severe SA) during 58% of the observation period. An AHRE burden of ≥5 min/day was documented in 139 (34%) patients, ≥6 h/day in 89 (22%) patients, and ≥23 h/day in 68 (17%) patients. The IN-alert HF state was independently associated with AHRE regardless of the daily burden threshold: hazard ratios from 2.17 for ≥5 min/day to 3.43 for ≥23 h/day (P < 0.01). An RDI ≥ 30 episodes/h was associated only with AHRE burden ≥5 min/day [hazard ratio 1.55 (95% confidence interval: 1.11-2.16), P = 0.001]. The combination of IN-alert HF state and RDI ≥ 30 episodes/h accounted for only 6% of the follow-up period and was associated with high rates of AHRE occurrence (from 28 events/100 patient-years for AHRE burden ≥5 min/day to 22 events/100 patient-years for AHRE burden ≥23 h/day). CONCLUSIONS: In HF patients, the occurrence of AHRE is independently associated with the ICD-measured IN-alert HF state and RDI ≥ 30 episodes/h. The coexistence of these two conditions occurs rarely but is associated with a very high rate of AHRE occurrence. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Insuficiencia Cardíaca , Síndromes de la Apnea del Sueño , Humanos , Desfibriladores Implantables/efectos adversos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/terapia , Medición de Riesgo , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia
14.
Heart Rhythm ; 20(7): 992-997, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36966948

RESUMEN

BACKGROUND: The HeartLogic algorithm (Boston Scientific) has proved to be a sensitive and timely predictor of impending heart failure (HF) decompensation. OBJECTIVE: The purpose of this study was to determine whether remotely monitored data from this algorithm could be used to identify patients at high risk for mortality. METHODS: The algorithm combines implantable cardioverter-defibrillator (ICD)-measured accelerometer-based heart sounds, intrathoracic impedance, respiration rate, ratio of respiration rate to tidal volume, night heart rate, and patient activity into a single index. An alert is issued when the index crosses a programmable threshold. The feature was activated in 568 ICD patients from 26 centers. RESULTS: During median follow-up of 26 months [25th-75th percentile 16-37], 1200 alerts were recorded in 370 patients (65%). Overall, the time IN-alert state was 13% of the total observation period (151/1159 years) and 20% of the follow-up period of the 370 patients with alerts. During follow-up, 55 patients died (46 in the group with alerts). The rate of death was 0.25 per patient-year (95% confidence interval [CI] 0.17-0.34) IN-alert state and 0.02 per patient-year (95% CI 0.01-0.03) OUT of the alert state, with an incidence rate ratio of 13.72 (95% CI 7.62-25.60; P <.001). After multivariate correction for baseline confounders (age, ischemic cardiomyopathy, kidney disease, atrial fibrillation), the IN-alert state remained significantly associated with the occurrence of death (hazard ratio 9.18; 95% CI 5.27-15.99; P <.001). CONCLUSION: The HeartLogic algorithm provides an index that can be used to identify patients at higher risk for all-cause mortality. The index state identifies periods of significantly increased risk of death.


Asunto(s)
Fibrilación Atrial , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Terapia de Resincronización Cardíaca/efectos adversos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/etiología , Fibrilación Atrial/terapia , Algoritmos
15.
J Cardiovasc Electrophysiol ; 34(5): 1257-1267, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36994907

RESUMEN

INTRODUCTION: The prediction of ventricular tachyarrhythmias among patients with implantable cardioverter defibrillators is difficult with available clinical tools. We sought to assess whether in patients with heart failure (HF) and reduced ejection fraction with defibrillators, physiological sensor-based HF status, as summarized by the HeartLogic index, could predict appropriate device therapies. METHODS: Five hundred and sixty-eight consecutive HF patients with defibrillators (n = 158, 28%) or cardiac resynchronization therapy-defibrillators (n = 410, 72%) were included in this prospective observational multicenter analysis. The association of both HeartLogic index and its physiological components with defibrillator shocks and overall appropriate therapies was assessed in regression and time-dependent Cox models. RESULTS: Over a follow-up of 25 (15-35) months, 122 (21%) patients received an appropriate device therapy (shock, n = 74, 13%), while the HeartLogic index crossed the threshold value (alert, HeartLogic ≥ 16) 1200 times (0.71 alerts/patient-year) in 370 (65%) subjects. The occurrence of ≥1 HeartLogic alert was significantly associated with both appropriate shocks (Hazard ratios [HR]: 2.44, 95% confidence interval [CI]: 1.49-3.97, p = .003), and any appropriate defibrillator therapies. In multivariable time-dependent Cox models, weekly IN-alert state was the strongest predictor of appropriate defibrillator shocks (HR: 2.94, 95% CI: 1.73-5.01, p < .001) and overall therapies. Compared with stable patients, patients with appropriate shocks had significantly higher values of HeartLogic index, third heart sound amplitude, and resting heart rate 30-60 days before device therapy. CONCLUSION: The HeartLogic index is an independent dynamic predictor of appropriate defibrillator therapies. The combined index and its individual physiological components change before the arrhythmic event occurs.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Taquicardia Ventricular , Disfunción Ventricular Izquierda , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Taquicardia Ventricular/complicaciones , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/complicaciones , Terapia de Resincronización Cardíaca/efectos adversos , Disfunción Ventricular Izquierda/terapia
17.
Heart Vessels ; 38(5): 680-688, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36418560

RESUMEN

No real-world data are available about the complications rate in drug-induced type 1 Brugada Syndrome (BrS) patients with an implantable cardioverter-defibrillator (ICD). Aim of our study is to compare the device-related complications, infections, and inappropriate therapies among drug-induced type 1 BrS patients with transvenous- ICD (TV-ICD) versus subcutaneous-ICD (S-ICD). Data for this study were sourced from the IBRYD (Italian BRugada sYnDrome) registry which includes 619 drug-induced type-1 BrS patients followed at 20 Italian tertiary referral hospitals. For the present analysis, we selected 258 consecutive BrS patients implanted with ICD. 198 patients (76.7%) received a TV-ICD, while 60 a S-ICD (23.4%). And were followed-up for a median time of 84.3 [46.5-147] months. ICD inappropriate therapies were experienced by 16 patients (6.2%). 14 patients (7.1%) in the TVICD group and 2 patients (3.3%) in S-ICD group (log-rank P = 0.64). ICD-related complications occurred in 31 patients (12%); 29 (14.6%) in TV-ICD group and 2 (3.3%) in S-ICD group (log-rank P = 0.41). ICD-related infections occurred in 10 patients (3.88%); 9 (4.5%) in TV-ICD group and 1 (1.8%) in S-ICD group (log-rank P = 0.80). After balancing for potential confounders using the propensity score matching technique, no differences were found in terms of clinical outcomes between the two groups. In a real-world setting of drug-induced type-1 BrS patients with ICD, no significant differences in inappropriate ICD therapies, device-related complications, and infections were shown among S-ICD vs TV-ICD. However, a reduction in lead-related complications was observed in the S-ICD group. In conclusion, our evidence suggests that S-ICD is at least non-inferior to TV-ICD in this population and may also reduce the risk of lead-related complications which can expose the patients to the necessity of lead extractions.


Asunto(s)
Síndrome de Brugada , Desfibriladores Implantables , Humanos , Desfibriladores Implantables/efectos adversos , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Síndrome de Brugada/etiología , Puntaje de Propensión , Cardioversión Eléctrica/efectos adversos , Electrocardiografía/métodos , Muerte Súbita Cardíaca/epidemiología , Resultado del Tratamiento
18.
JACC Clin Electrophysiol ; 8(12): 1553-1562, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36543505

RESUMEN

BACKGROUND: Causes of sex differences in incidence of sustained ventricular arrhythmias (SVAs) are poorly understood. OBJECTIVES: This study aims to investigate sex-specific risk of SVAs and device therapies by balancing sex groups in relation to several baseline characteristics with the propensity score (PS). METHODS: We used a large remote monitoring dataset from implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-Ds). Study endpoints were time to the first appropriate SVA, time to the first device therapy for SVA, and time to the first ICD shock. Results were compared between females and a PS-matched male subgroup. RESULTS: In a cohort of 2,532 patients with an ICD or CRT-D (median age, 70 years), 488 patients (19.3%) were women. After selecting 488 men PS-matched for 19 variables relative to baseline demographics, implant indications, principal comorbidities, and concomitant therapy, yet the SVA rate at the 2.1-year median follow-up was significantly lower in women than in man (adjusted HR: 0.65; 95% CI: 0.51-0.81; P < 0.001). Women also showed a reduced risk of any device therapy (HR: 0.59; 95% CI: 0.45-0.76; P < 0.001) and shocks (HR: 0.66; 95% CI: 0.47-0.94; P = 0.021). Differences in sex-specific SVA risk profile were not confirmed in CRT-D patients (HR: 0.78; 95% CI: 0.55-1.09; P = 0.14) nor in those with an ejection fraction <30% (HR: 0.80; 95% CI: 0.52-1.23; P = 0.31). CONCLUSIONS: After matching demographics, indications, principal comorbidities, and concomitant therapy, women still exhibited a lower SVA risk profile than men, except in the subgroups of CRT-D or/and ejection fraction <30%.


Asunto(s)
Desfibriladores Implantables , Humanos , Masculino , Femenino , Anciano , Desfibriladores Implantables/efectos adversos , Puntaje de Propensión , Resultado del Tratamiento , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/terapia , Cardioversión Eléctrica
19.
JACC Clin Electrophysiol ; 8(10): 1249-1256, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36266001

RESUMEN

BACKGROUND: Sleep-disordered breathing is highly prevalent in heart failure (HF) and has been suggested as a risk factor for malignant ventricular arrhythmias. The Respiratory Disturbance Index (RDI) computed by an implantable cardioverter-defibrillator (ICD) algorithm accurately identifies severe sleep apnea. OBJECTIVES: In the present analysis, the authors evaluated the association between ICD-detected sleep apnea and the incidence of appropriate ICD therapies in patients with HF. METHODS: We enrolled 411 HF patients who had received an ICD endowed with an algorithm that calculates the RDI each night. In this analysis, the weekly mean RDI value was considered. The endpoint was the first appropriate ICD shock. RESULTS: The median follow-up was 26 months (25th to 75th percentile: 16-35 months). During follow-up, 1 or more ICD shocks were documented in 58 (14%) patients. Patients with shocks were younger (age 66 ± 13 years vs 70 ± 10 years; P = 0.038), and had more frequently undergone implantation for secondary prevention (21% vs 10%; P = 0.026). The maximum RDI value calculated during the entire follow-up period did not differ between patients with and without shocks (55 ± 15 episodes/h vs 54 ± 14 episodes/h; P = 0.539). However, the ICD-detected RDI showed considerable variability during follow-up. The overall median of the weekly RDI was 33 episodes/h (25th to 75th percentile: 24-45 episodes/h). A time-dependent Cox regression model revealed that a continuously measured weekly mean RDI of ≥45 episodes/h was independently associated with shock occurrence (HR: 4.63; 95% CI: 2.54-8.43; P < 0.001), after correction for baseline confounders (age, secondary prevention). CONCLUSIONS: In HF patients, appropriate ICD shocks were more likely to be delivered during periods when patients exhibited more sleep-disordered breathing. (Arrhythmias Detection in a Real World Population [RHYTHM DETECT]; NCT02275637).


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Síndromes de la Apnea del Sueño , Anciano , Humanos , Persona de Mediana Edad , Arritmias Cardíacas/epidemiología , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia , Síndromes de la Apnea del Sueño/diagnóstico , Síndromes de la Apnea del Sueño/epidemiología
20.
Int J Cardiol ; 365: 49-56, 2022 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-35907505

RESUMEN

BACKGROUND: Safety and efficacy of leadless pacemakers (L-PM) have been demonstrated in multiple clinical trials, but real-world data on patient selection, implantation technique, and peri-procedural patient management in a clinical practice setting are lacking. METHODS: Consecutive patients undergoing L-PM implantation in 14 Italian centers were followed in a prospective, multicentre, observational project. Data on baseline patient characteristics, clinical indications, implantation procedure, and peri-procedural patient management were collected. The rate and nature of device-related complications were also recorded. RESULTS: A total of 782 L-PM patients (68.4% male, 75.6 ± 12.4 years) were included in the analysis. The main patients-related reason leading to the choice of implanting a L-PM rather than a conventional PM was the high-risk of device infection (29.5% of cases). The implantation success rate was 99.2%. The median duration of the procedure was 46 min. In 90% of patients the device was implanted in the septum. Of patients on oral anticoagulant therapy (OAT) (n = 498) the implantation procedure was performed without interrupting (17.5%) or transiently interrupting OAT without heparin bridging (60.6%). During a median follow-up of 20 months major device-related complications occurred in 7 patients (0.9%): vascular access-site complications in 3 patients, device malfunction in 2 patients, pericardial effusion/cardiac tamponade in one patient, device migration in one patient. CONCLUSIONS: In the real world setting of Italian clinical practice L-PM is often reserved for patients at high-risk of infection. The implantation success rate was very high and the risk of major complications was low. Peri-procedural management of OAT was consistent with available scientific evidence.


Asunto(s)
Marcapaso Artificial , Derrame Pericárdico , Diseño de Equipo , Femenino , Humanos , Masculino , Marcapaso Artificial/efectos adversos , Derrame Pericárdico/etiología , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento