Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Intervalo de año de publicación
1.
Braz. dent. sci ; 26(4): 1-9, 2023. ilus, tab
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1511772

RESUMEN

Objective: This study evaluated Proanthocyanidin protective effect on dentin subjected to erosion and its inhibition on degradation of the demineralized organic matrix (DOM). Material and Methods: The tested groups were: G1 - 10% Proanthocyanidin gel (test group), G2 - 1.23% NaF (positive control 1), G3 - 0.012% Chlorhexidine (positive control 2) and G4 ­ Placebo (negative control with no active compound) and two methodologies were performed: contact profilometry and ICTP ELISA method. To quantify dentin wear, profilometry was performed. Data were submitted to Analysis of Variance followed by Fisher's LSD Test. To assess the collagen degradation, ICTP ELISA method was performed. Data were submitted to the Kruskal-Wallis followed by the Dunn ́s test. Simple linear regression and Pearson Correlation test were also performed (p<0.05). Results: The profilometry showed significantly lower wear of G1 when compared to other groups and G2, G3 and G4, which did not present significant difference among them. In the ICTP ELISA analysis, G1 and G4 did not show significant differences and the same happened between G2 and G3. However, G1 and G4 had lower values of collagen degradation compared to groups G2 and G3. Data showed that degraded DOM is a significant predictor to explain the values obtained through the ICTP ELISA. Conclusions: The results allow to verify that 10% proanthocyanidin provided less tooth wear and decreased degradation of the DOM, suggesting a good ability to prevent dentin erosion. The regression analysis also suggests that contact profilometry is a good strategy to quantify dentin wear (AU)


Objetivo: Este estudo avaliou o efeito protetor da proantocianidina na dentina submetida à erosão e sua inibição na degradação da matriz orgânica desmineralizada (MOD). Material e Métodos: Os grupos testados foram: G1 - gel de Proantocianidina 10% (grupo teste), G2 - NaF 1,23% (controle positivo 1), G3 - Clorexidina 0,012% (controle positivo 2) e G4 - Placebo (controle negativo sem princípio ativo) e duas metodologias foram realizadas: perfilometria de contato e método ICTP ELISA. Para quantificar o desgaste da dentina, a perfilometria foi realizada. Os dados foram submetidos à Análise de Variância seguida do Teste LSD de Fisher. Para avaliar a degradação do colágeno, foi realizado o método ICTP ELISA. Resultados: Os dados foram submetidos ao teste de Kruskal-Wallis seguido do teste de Dunn. Regressão linear simples e teste de correlação de Pearson também foram realizados (p<0,05). A perfilometria mostrou desgaste significativamente menor do G1 quando comparado aos outros grupos e G2, G3 e G4, que não apresentaram diferença significativa entre si. Na análise ICTP ELISA, G1 e G4 não apresentaram diferenças significativas e o mesmo ocorreu entre G2 e G3. No entanto, G1 e G4 apresentaram valores menores de degradação do colágeno em relação aos grupos G2 e G3. Os dados mostraram que a MOD degradada é um preditor significativo para explicar os valores obtidos pelo ICTP ELISA. Conclusão: Os resultados permitem verificar que a proantocianidina a 10% proporcionou menor desgaste dentário e diminuição da degradação da MOD, sugerindo uma boa capacidade de prevenir a erosão dentinária. Também sugere que a perfilometria de contato é uma boa estratégia para quantificar o desgaste da dentina (AU)


Asunto(s)
Servicios Preventivos de Salud , Erosión de los Dientes , Proantocianidinas , Dentina , Desgaste de los Dientes
2.
Full dent. sci ; 9(35): 102-108, 2018. ilus
Artículo en Portugués | BBO - Odontología | ID: biblio-994506

RESUMEN

Dentre os tratamentos disponíveis para as lesões cariosas incipientes em superfícies livres, a técnica de infiltração de cárie utilizando resinas compostas fluidas representa uma abordagem que vem se destacando como uma excelente alternativa. Devido às suas particularidades, estabelece uma barreira dentro da lesão reforçando sua estrutura enfraquecida, tornando-a ácido-resistente e impedindo a sua progressão a um estágio de cavitação. Assim o objetivo deste trabalho é apresentar o tratamento empregando infiltrante em um caso clínico de um paciente cuja queixa principal eram as manchas brancas que comprometiam a harmonia do seu sorriso. Ao exame clínico, observaram-se lesões iniciais de cárie com aspecto de mancha branca. O tratamento proposto foi o de orientação de higiene bucal, além de neutralização das lesões incipientes através do tratamento das manchas brancas com auxílio do infiltrante. Após profilaxia e isolamento absoluto, foi realizada a aplicação do agente infiltrante com aplicação de ácido clorídrico 15% (Icon Etch - DMG) por 2 minutos, lavagem por 30 segundos, aplicação de álcool absoluto (Icon Dry - DMG), secagem por 30 segundos e, posteriormente, aplicação do agente infiltrante (Icon Infiltrant - DMG) durante 3 minutos, seguido de fotoativação por 40 segundos. Foi feita nova aplicação do agente infiltrante com espera de 1 minuto seguida de fotoativação por 40 segundos. Procedeu-se então ao acabamento e polimento. Após o término do tratamento, foi constatada a estabilização da atividade de cárie e a redução significativa das manchas brancas, o que melhorou a aparência do sorriso do paciente, que demonstrou satisfação imediata e após os 10 meses de acompanhamento do caso (AU).


Among the treatments available for incipient carious lesions on free surfaces, the caries infiltration technique using fluid composite resins represents an approach that has been highlighted as an excellent alternative. Due to its particularities, it establishes a barrier in the lesion by reinforcing its weakened structure, making it acid-resistant and preventing its progression to a cavitation stage. Thus, the aim of this case report is to present the treatment using infiltrant in a clinical case of a patient whose main complaint was white spot lesions that compromised the harmony of his smile. Clinical examination revealed initial caries lesions with white spot appearance. The proposed treatment was oral hygiene guidance and also incipient lesions neutralization through white spots treatment with the aid of infiltrant agent. After prophylaxis and absolute isolation, the infiltrant agent was applied with 15% hydrochloric acid (Icon Etch - DMG) for 2 minutes, rinsing for 30 seconds, application of absolute alcohol (Icon Dry - DMG), drying for 30 seconds and, after that, infiltrant agent (Icon Infiltrator - DMG) was applied for 3 minutes, followed by photoactivation for 40 seconds. Infiltrant agent new application was performed with 1-minute-wait followed by photoactivation for 40 seconds. Finishing and polishing were then carried out. After the treatment end stabilization of caries activity and significant reduction of white spots were observed, which improved the patient's smile appearance, who showed immediate and after 10 month case follow up of satisfaction (AU).


Asunto(s)
Humanos , Masculino , Niño , Resinas Compuestas , Caries Dental/prevención & control , Filtración Dental , Estética Dental , Higiene Bucal , Brasil , Informes de Casos
3.
Bauru; s.n; 2017. 61 p. ilus, tab.
Tesis en Inglés | BBO - Odontología | ID: biblio-879631

RESUMEN

Apesar de inúmeras vantagens, tal como alta resistência, a cimentação da zircônia ainda é crítica. No presente estudo nanotubos de TiO2 foram sintetizados e aplicados sobre a superfície da zircônia, essa superfície foi caracterizada e posteriormete foi conduzido o teste de resistência de união a um cimento resinoso. Os nanotubos de TiO2 foram produzidos por síntese alcalina, misturados com álcool isopropílico (50% em peso) e aplicados em fatias de zircônia pré-sinterizados (IPS e.max ZirCAD). As cerâmicas foram sinterizadas e as superfícies foram caracterizadas por microscopia confocal a laser, microscopia eletrônica de varredura (SEM) e análise de composição atômica por EDS. Para a resistência de união foram avaliados seis grupos (n = 16): 1) sem aplicação de nanotubos de TiO2 e Single Bond Universal; 2) com a aplicação de nanotubos de TiO2 e Single Bond Universal; 3) sem aplicação de nanotubos de TiO2 e Z-prime; 4) com aplicação de nanotubos de TiO2 e Z-prime; 5) sem aplicação de nanotubos de TiO2 e Signum Zirconia Bond ; 6) com aplicação de nanotubos de TiO2 e Signum Zirconia Bond. Após a sinterização, foram preparados cilindros de cimento resinoso (RelyX Ultimate) com um diâmetro de 1,40 mm e 1 mm de altura, fotopolimerizados por luz durante 40 s. Os espécimes foram armazenados durante 30 dias em água destilada a 37°C e submetidos a ensaio de microcisalhamento. Os nanotubos de TiO2 foram incorporados na superfície de zircônia e a análise EDS confirmou que os nanoaglomerados eram compostos de TiO2. O teste de microcisalhamento mostrou diferença estatística significativa entre os grupos analisados. Não houve diferença estatística significativa com a aplicação dos nanotubos, independentemente do grupo analisado. Pode-se concluir que foi possível incorporar nanotubos às superfícies de zircônia, porém esta incorporação não melhorou a resistência de união. (AU)


Despite numerous advantages such as high strength, cementing zirconia is still critical. In the present study TiO2 nanotubes were synthesized and applied over zirconia surface. This surface was characterized and after that the bond strength test was conducted to a resin cement. TiO2 nanotubes were produced by alkaline synthesis, mixed with isopropyl alcohol (50 wt%) and applied on pre-sintered zirconia slices (IPS e.max ZirCAD). The ceramics were sintered and surfaces were characterized by confocal laser microscopy, scanning electron microscopy (SEM) and EDS analysis. For the bond strength, six groups (n = 16) were evaluated: 1) without application of TiO2 and Single Bond Universal; 2) with the application of TiO2 nanotubes and Single Bond Universal; 3) without application of TiO2 nanotubes and Z-prime; 4) with application of TiO2 nanotubes and Z-prime; 5) without application of TiO2 and Signum Zirconia Bond; 6) with application of TiO2 and Signum Zirconia Bond. After sintering, resin cement (RelyX Ultimate) cylinders with diameter of 1.40 mm and 1 mm in height were prepared and light cured for 40 s. The specimens were stored for 30 days in distilled water at 37°C and submitted to shear test. The nanotubes were incorporated in the zirconia surface and the EDS analysis has confirmed that the nanoagglomerates were composed of TiO2. The shear bond strength showed there was significant statistical difference among the analyzed groups. There was no significant statistical difference with the application of the nanotubes regardless of the analyzed group. It may be concluded that it was possible to incorporate nanotubes to the zirconia surfaces, however this incorporation did not improve the bond strength. (AU)


Asunto(s)
Cementación/métodos , Nanotubos/química , Titanio/química , Circonio/química , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Reproducibilidad de los Resultados , Resistencia al Corte , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...