Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Front Cardiovasc Med ; 9: 910313, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36304537

RESUMEN

Background: Provisional stenting (PS) is the main treatment for a majority of coronary bifurcation lesion and includes PS with 1-stent and PS with 2-stent. However, the treatment difference between PS with 1-stent and with 2-stent remains unclear in patients with the acute coronary syndrome (ACS) and coronary bifurcation lesions. Materials and methods: Overall, 820 ACS patients with Medina 1,1,1 or 0,1,1 coronary bifurcation lesion who had completed 3-year follow-up were included and assigned to the PS with 1-stent (n = 519) or the PS with 2-stent (n = 301) according to the use of final stenting technique. The primary endpoint was the target lesion failure (TLF) at 3 years since stenting procedures. Results: At 3-year follow-up, TLF occurred in 85 (16.4%) patients in the PS with 1-stent group and 69 (22.9%) in the PS with 2-stent group (hazard ratio [HR] 1.52, 95% confidence interval [CI] 1.06-2.17, p = 0.021), mainly driven by a higher rate of target lesion revascularization (TLR) in the PS with 2-stent group (13.0% vs. 8.3%, HR 1.65, 95% CI 1.04-2.61, p = 0.033). Complex bifurcations, side branch (SB) pretreatment, intravascular imaging guidance, and hyperlipidemia were the four predictors for 3-year TLF. SB pretreatment was associated with increased 3-year TLR, leading to an extremely higher 3-year TLF. Conclusion: Provisional with 2-stent for patients with ACS is associated with a higher rate of 3-year TLF, mainly due to increased requirement of revascularization. SB pretreatment should be avoided for simple bifurcation lesion.

2.
JACC Cardiovasc Interv ; 15(13): 1310-1320, 2022 07 11.
Artículo en Inglés | MEDLINE | ID: mdl-35798473

RESUMEN

BACKGROUND: The multicenter and randomized DEFINITION II (Two-Stent vs Provisional Stenting Techniques for Patients With Complex Coronary Bifurcation Lesions) trial showed less 1-year target lesion failure (TLF) after a 2-stent approach for complex coronary bifurcation lesions compared with provisional stenting (PS). The authors report the 3-year clinical outcome of the DEFINITION II trial. OBJECTIVES: The aim of the present study was to investigate the difference in TLF at 3 years after a planned 2-stent approach vs PS for complex coronary bifurcation lesions stratified by DEFINITION (Definitions and Impact of Complex Bifurcation Lesions on Clinical Outcomes After Percutaneous Coronary Intervention Using Drug-Eluting Stents) criteria. METHODS: A total of 653 patients with complex coronary bifurcation lesions were randomly assigned to either the 2-stent group or the PS group in the DEFINITION II trial and were followed for 3 years. The primary endpoint was the occurrence of TLF at 3 years. Stent thrombosis was the safety endpoint. RESULTS: At 3 years, TLF had occurred in 52 patients (16.0%) in the PS group and in 34 (10.4%) patients in the 2-stent group (HR: 0.63; 95% CI: 0.41-0.97; P = 0.035), driven mainly by increased target vessel myocardial infarction (8.0% vs 3.7%; HR: 0.45; 95% CI: 0.23-0.89; P = 0.022) and target lesion revascularization (8.3% vs 4.3%; HR: 0.50; 95% CI: 0.26-0.96; P = 0.038). There was no difference in TLF between the 2 groups between year 1 and year 3. CONCLUSIONS: For patients with complex coronary bifurcations who reach 1-year postprocedure without experiencing endpoint events, there is still a risk for future events. The type of procedure performed initially is no longer a future event risk determinant. (Two-Stent vs Provisional Stenting Techniques for Patients With Complex Coronary Bifurcation Lesions; NCT02284750).


Asunto(s)
Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/terapia , Anomalías de los Vasos Coronarios/terapia , Intervención Coronaria Percutánea , Stents/clasificación , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Humanos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
3.
BMJ Open ; 12(3): e052788, 2022 03 11.
Artículo en Inglés | MEDLINE | ID: mdl-35277400

RESUMEN

INTRODUCTION: Provisional stenting using drug-eluting stent is effective for simple coronary bifurcation lesions. Kissing balloon inflation using conventional non-compliant balloon is the primary treatment of side branch (SB) after main vessel (MV) stenting. Drug-coating balloon (DCB) is reported to be associated with less frequent clinical events in in-stent restenosis and small vessel disease. The importance of DCB in bifurcation treatment is understudied. Accordingly, this trial is designed to investigate the superiority of DCB to non-compliant balloon angioplasty for SB after provisional stenting in patients with true coronary bifurcation lesions. METHODS AND ANALYSIS: The DCB-BIF trial is a prospective, multicentre, randomised, superiority trial including 784 patients with true coronary bifurcation lesions. Patients will be randomised in a 1:1 fashion to receive either DCB or non-compliant balloon angioplasty if SB diameter stenosis >70% after MV stenting. The primary endpoint is the composite of major adverse cardiac event at the 1-year follow-up, including cardiac death, myocardial infarction (MI) or clinically driven target lesion revascularisation. The major secondary endpoints include all-cause death, periprocedural MI, spontaneous MI, clinically driven target vessel revascularisation, in-stent restenosis, stroke and individual component of the primary endpoint. The safety endpoint is the risk of stent thrombosis. ETHICS AND DISSEMINATION: The study protocol and informed consent have been reviewed and approved by the Institutional Review Board of all participating centres. The written informed consent for participation in the trial will be obtained from all participants. The results of this study will be published in a peer-reviewed journal and disseminated at conferences. TRIAL REGISTRATION NUMBER: NCT04242134.


Asunto(s)
Angioplastia Coronaria con Balón , Enfermedad de la Arteria Coronaria , Reestenosis Coronaria , Estenosis Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio , Angioplastia Coronaria con Balón/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/cirugía , Estenosis Coronaria/cirugía , Stents Liberadores de Fármacos/efectos adversos , Humanos , Infarto del Miocardio/etiología , Estudios Prospectivos , Stents/efectos adversos , Resultado del Tratamiento
4.
Catheter Cardiovasc Interv ; 99(3): 617-626, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34494355

RESUMEN

BACKGROUND: Five definitions of peri-procedural myocardial infarction (PMI) following percutaneous coronary intervention (PCI) are used in clinical trials; their clinical relevance in coronary bifurcation stenting remains unclear. OBJECTIVES: To understand the correlation between PMI and mortality in bifurcation lesions from the DKCRUSH studies. METHODS: PMI was defined using serum creatine kinase-myocardial band (CK-MB) values within 48 h of PCI according to the SYNTAX, Fourth Universal Definition of MI (4th UDMI), ISCHEMIA, SCAI, and EXCEL definitions. Overall, 1300 patients with both CK and CK-MB measurements pre- and post-stenting were evaluated. The association of each PMI type and all-cause death or cardiac death at a median of 5.58 years of follow-up was analyzed using Cox regression. RESULTS: In total, 56 (4.3%) patients had PMI. According to SYNTAX, 4th UDMI or ISCHEMIA, SCAI, and EXCEL definitions, PMI occurred in 21 (1.6%), 56 (4.3%), 29 (2.2%), and 32 (2.5%) patients, respectively. All definitions were significantly correlated with unadjusted mortality at the end of follow-up but not at 30 days or 1-year after stenting. PMI using SYNTAX, SCAI, and EXCEL definitions rather than 4th UDMI definition was strongly associated with adjusted all-cause death. By adjusted analysis, PMI according to 4th UDMI, SCAI, and EXCEL definitions but not SYNTAX definition was positively correlated with cardiac death at a median of 5.58 years of follow-up. CK-MB ≥ 5 x UNL strongly enhanced the correlation of CK-MB values with mortality. CONCLUSIONS: PMI rate varies with the definition following stenting for bifurcation lesions. PMI defined by SCAI and EXCEL definitions is strongly correlates with adjusted all-cause and cardiac death.


Asunto(s)
Enfermedad de la Arteria Coronaria , Infarto del Miocardio , Intervención Coronaria Percutánea , Biomarcadores , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Análisis de Datos , Humanos , Intervención Coronaria Percutánea/efectos adversos , Ensayos Clínicos Controlados Aleatorios como Asunto , Factores de Riesgo , Resultado del Tratamiento
5.
Catheter. cardiovasc. interv ; 98(6): 1102-1110, Nov. 2021. ilus, graf, tab
Artículo en Inglés | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1352801

RESUMEN

OBJECTIVES: This study explores the safety and efficacy of thin strut MeRes100 sirolimus-eluting bioresorbable vascular scaffold (BRS) in patients with de novo coronary artery lesions. BACKGROUND: In interventional cardiology, the emergence of BRS technology is catalyzing the next paradigm shift. METHODS: The MeRes-1 Extend was a multicenter, prospective, single-arm, open-label study enrolling 64 patients in Spain, Macedonia, Brazil, South Africa, Malaysia, and Indonesia. The safety endpoint was major adverse cardiac events (MACE) which composed of cardiac death, myocardial infarction (MI), and ischemia-driven target lesion revascularization (ID-TLR). The imaging efficacy endpoint was mean in-scaffold late lumen loss (LLL) evaluated by quantitative coronary angiography (QCA). Optical coherence tomography (OCT) imaging was performed at baseline and 6-month follow-up. RESULTS: A total of 69 target lesions were identified in 64 enrolled patients (mean age 58.30 ± 9.02 years). Of the treated lesions, 49 (71.01%) lesions were of type B2/C. Procedural and device success was achieved in 64 and 62 patients, respectively. At 2-year follow-up, MACE was reported in one patient (1.61%) in the form of ID-TLR. There was no case of MI, cardiac death or scaffold thrombosis through 2-year. In a subset of 32 patients, paired QCA showed mean in-scaffold LLL of 0.18 ± 0.31 mm at 6-month follow-up. In a subset of 21 patients, OCT revealed 97.95 ± 3.69% strut coverage with mean scaffold area of 7.56 ± 1.79 mm2 and no evidence of strut malapposition. CONCLUSIONS: The clinical and imaging outcomes of MeRes-1 Extend trial demonstrated favorable safety and efficacy of MeRes100 sirolimus-eluting BRS in patients with de novo coronary artery lesions.


Asunto(s)
Angiografía Coronaria , Tomografía de Coherencia Óptica , Infarto del Miocardio
6.
Eur Cardiol ; 16: e25, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34163538

RESUMEN

Transcatheter mitral valve repair with the MitraClip, a catheter-based percutaneous edge-to-edge repair technique to correct mitral regurgitation (MR), has been demonstrated in Western studies to be an effective and safe MR treatment strategy. However, randomised clinical trial data on its use in Asian-Pacific patients is limited. Hence, the Asian Pacific Society of Cardiology convened an expert panel to review the available literature on MitraClip and to develop consensus recommendations to guide clinicians in the region. The panel developed statements on the use of MitraClip for the management of degenerative MR, functional MR, and other less common indications, such as acute MR, dynamic MR, hypertrophic obstructive cardiomyopathy, and MR after failed surgical repair. Each statement was voted on by each panel member and consensus was reached when 80% of experts voted 'agree' or 'neutral'. This consensus-building process resulted in 10 consensus recommendations to guide general cardiologists in the evaluation and management of patients in whom MitraClip treatment is being contemplated.

7.
Catheter Cardiovasc Interv ; 98(6): 1102-1110, 2021 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-33269506

RESUMEN

OBJECTIVES: This study explores the safety and efficacy of thin strut MeRes100 sirolimus-eluting bioresorbable vascular scaffold (BRS) in patients with de novo coronary artery lesions. BACKGROUND: In interventional cardiology, the emergence of BRS technology is catalyzing the next paradigm shift. METHODS: The MeRes-1 Extend was a multicenter, prospective, single-arm, open-label study enrolling 64 patients in Spain, Macedonia, Brazil, South Africa, Malaysia, and Indonesia. The safety endpoint was major adverse cardiac events (MACE) which composed of cardiac death, myocardial infarction (MI), and ischemia-driven target lesion revascularization (ID-TLR). The imaging efficacy endpoint was mean in-scaffold late lumen loss (LLL) evaluated by quantitative coronary angiography (QCA). Optical coherence tomography (OCT) imaging was performed at baseline and 6-month follow-up. RESULTS: A total of 69 target lesions were identified in 64 enrolled patients (mean age 58.30 ± 9.02 years). Of the treated lesions, 49 (71.01%) lesions were of type B2/C. Procedural and device success was achieved in 64 and 62 patients, respectively. At 2-year follow-up, MACE was reported in one patient (1.61%) in the form of ID-TLR. There was no case of MI, cardiac death or scaffold thrombosis through 2-year. In a subset of 32 patients, paired QCA showed mean in-scaffold LLL of 0.18 ± 0.31 mm at 6-month follow-up. In a subset of 21 patients, OCT revealed 97.95 ± 3.69% strut coverage with mean scaffold area of 7.56 ± 1.79 mm2 and no evidence of strut malapposition. CONCLUSIONS: The clinical and imaging outcomes of MeRes-1 Extend trial demonstrated favorable safety and efficacy of MeRes100 sirolimus-eluting BRS in patients with de novo coronary artery lesions.


Asunto(s)
Fármacos Cardiovasculares , Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Implantes Absorbibles , Anciano , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Sirolimus/efectos adversos , Resultado del Tratamiento
8.
J Interv Card Electrophysiol ; 61(2): 269-281, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32588371

RESUMEN

PURPOSE: To develop a consensus statement for left atrial appendage occlusion (LAAO) in Asian-Pacific patients with non-valvular atrial fibrillation (NVAF) at risk of ischemic stroke. The need for such a region-specific consensus was indicated by the relative paucity of clinical evidence for LAAO and oral anticoagulation therapy obtained in Asian-Pacific populations and the specific stroke and bleeding characteristics of this population. METHODS: Consensus was developed by discussion and evaluation of available evidence and expert opinions during a 2-day meeting attended by clinical experts from the Asian-Pacific regions. RESULTS: The consensus statement arrived at provides recommendations based on available evidence and expert opinions regarding LAAO in Asian-Pacific patients. Gaps in the evidence and other areas requiring further research were identified. CONCLUSION: LAAO is an alternative device-based therapy in carefully selected patients with NVAF at risk of ischemic stroke. However, evidence for LAAO is primarily obtained from Caucasian populations, and data on LAAO in Asian-Pacific patients are scarce. While the present consensus statement addresses several therapy-related aspects based on careful interpretation of available evidence and expert opinions, other areas require additional evidence derived from Asian-Pacific populations.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Isquemia Encefálica , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/complicaciones , Consenso , Testimonio de Experto , Humanos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento
9.
J. Am. Coll. Cardiol ; 76(17 suppl. b): 118-118, Oct., 2020.
Artículo en Inglés | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1343470

RESUMEN

BACKGROUND The long- term clinical outcomes of percutaneous coronary intervention can be improved by replacing metallic drug eluting stents with bioresorbable vascular scaffolds. The MeRes-1 Extend trial was designed to assess the safety and efficacy of a novel thin-strut MeRes100 bioresorbable vascular scaffold (Meril Life Sci ences) in a diverse patient population. METHODS The MeRes-1 Extend was a prospective, multicenter, sin gle-arm study that enrolled 64 patients in Spain, Macedonia, Brazil, South Africa, Malaysia, and Indonesia. Major adverse cardiac events, consisting of cardiac death, myocardial infarction, and ischemia driven target lesion revascularisation, were the safety endpoint. At baseline and 6-month follow-up, quantitative coronary angiography and optical coherence tomography were performed. RESULTS Of all patients enrolled (mean age: 58.30 9.02 years), 76.56% had hypertension, 26.56% had diabetes mellitus, 48.44% had dyslipidemia, and 28.13% had a previous myocardial infarction; 68.75% of patients presented with stable angina, 9.38% with unstable angina, and 21.88% with silent ischemia. A total of 69 target lesions (mean length: 14.37 5.89 mm) were detected of which 71.01% were type B2/C. Procedural and device success were achieved in 64 and 62 patients, respectively. Major adverse cardiac events rate was reported in 1 patient (1.61%) in the form of ischemia-driven target lesion revascularization; there were no cases of myocardial infarction, car diac death, or scaffold thrombosis. At 6-month angiographic follow-up (n » 32), mean in-scaffold late lumen loss was 0.18 0.31 mm. Optical coherence tomography analysis (n » 21) showed 97.95 3.69% strut coverage and mean scaffold area of 7.56 1.79 mm2, with no strut malapposition. Updated data will be presented during Transcatheter Cardiovascular Therapeutics 2020 annual meeting. CONCLUSION Two-year clinical and 6-month imaging outcomes of MeRes-1 Extend trial demonstrated favorable safety and efficacy of novel thin-strut MeRes100 sirolimus-eluting bioresorbable vascular scaffolds in patients with de novo coronary artery lesions.


Asunto(s)
Stents Liberadores de Fármacos , Intervención Coronaria Percutánea
10.
Eur Heart J ; 41(27): 2523-2536, 2020 07 14.
Artículo en Inglés | MEDLINE | ID: mdl-32588060

RESUMEN

AIM: The present study aimed to assess the benefits of two-stent techniques for patients with DEFINITION criteria-defined complex coronary bifurcation lesions. METHODS AND RESULTS: In total, 653 patients with complex bifurcation lesions at 49 international centres were randomly assigned to undergo the systematic two-stent technique (two-stent group) or provisional stenting (provisional group). The primary endpoint was the composite of target lesion failure (TLF) at the 1-year follow-up, including cardiac death, target vessel myocardial infarction (TVMI), and clinically driven target lesion revascularization (TLR). The safety endpoint was definite or probable stent thrombosis. At the 1-year follow-up, TLF occurred in 37 (11.4%) and 20 (6.1%) patients in the provisional and two-stent groups, respectively [77.8%: double-kissing crush; hazard ratio (HR) 0.52, 95% confidence interval (CI) 0.30-0.90; P = 0.019], largely driven by increased TVMI (7.1%, HR 0.43, 95% CI 0.20-0.90; P = 0.025) and clinically driven TLR (5.5%, HR 0.43, 95% CI 0.19-1.00; P = 0.049) in the provisional group. At the 1 year after indexed procedures, the incidence of cardiac death was 2.5% in the provisional group, non-significant to 2.1% in the two-stent group (HR 0.86, 95% CI 0.31-2.37; P = 0.772). CONCLUSION: For DEFINITION criteria-defined complex coronary bifurcation lesions, the systematic two-stent approach was associated with a significant improvement in clinical outcomes compared with the provisional stenting approach. Further study is urgently warranted to identify the mechanisms contributing to the increased rate of TVMI after provisional stenting. STUDY REGISTRATION: http://www.clinicaltrials.com; Identifier: NCT02284750.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Stents , Factores de Tiempo , Resultado del Tratamiento
11.
J. Am. Coll. Cardiol ; 74(13 supl): 115-115, Oct., 2019.
Artículo en Inglés | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1024911

RESUMEN

BACKGROUND: The development of bioresorbable vascular scaffold (BRS) offers a new treatment strategy for coronary artery lesion by replacement of a permanent metallic scaffold with a temporary scaffold and eradicating a nidus for very late adverse events. The first-in-human MeRes-1 trial reported favorable safety and efficacy of thin-strut (100 mm) MeRes100 sirolimus-eluting BRS (Meril Life Sciences Pvt. Ltd., India) in patients with de novo coronary artery lesions. Hence, to reaffirm the outcomes of the MeRes-1 trial, the MeRes-1 Extend trial sought to evaluate the safety and efficacy of the MeRes100 BRS in diverse patient population in Europe, Brazil, South Africa, and Asia Pacific. METHODS: The MeRes-1 Extend was a multicenter, prospective, single-arm study of MeRes100 BRS in 64 patients from Spain, Macedonia, Brazil, South Africa, Malaysia, and Indonesia. The safety endpoint was major adverse cardiac events (MACE), which composed of cardiac death, myocardial infarction (MI), and ischemia-driven target lesion revascularization (ID-TLR). Quantitative coronary angiography and optical coherence tomography (OCT) imaging was performed at baseline and 6-month follow-up. RESULTS: Among 64 enrolled patients (mean age: 58.30 _ 9.02 years), 26.56% had diabetes mellitus and 68.75% patients presented with stable angina. Of 69 target lesions, 71.01% were classified as type B2/C; average lesion length was 14.37 _ 5.89 mm and mean reference vessel diameter was 3.03 _ 0.35 mm. Procedural and device success was achieved in 64 and 62 patients, respectively. MACE was reported in 1 patient (1.61%) at 24-month follow-up in the form of ID-TLR with absence of MI, cardiac death, or scaffold thrombosis. At 6-month angiographic follow-up in a subset of 32 patients, mean in-scaffold LLL was 0.18 _ 0.31 mm. OCT analysis (n » 21) reported 97.95 _ 3.69% strut coverage with mean scaffold area of 7.56 _ 1.79 mm2 and no evidence of strut malapposition. CONCLUSION: Based on 2-year clinical and 6-month imaging outcomes, the MeRes-1 Extend trial established favorable safety and efficacy of MeRes100 sirolimus-eluting BRS in patients with de novo coronary artery lesions. (AU)


Asunto(s)
Enfermedad de la Arteria Coronaria , Andamios del Tejido , Stents Liberadores de Fármacos
12.
JACC Cardiovasc Interv ; 12(19): 1927-1937, 2019 10 14.
Artículo en Inglés | MEDLINE | ID: mdl-31521645

RESUMEN

OBJECTIVES: The present study aimed to investigate the difference in target lesion failure (TLF) at 3 years after double kissing (DK) crush stenting versus provisional stenting (PS) for unprotected left main distal bifurcation (UPLMb) lesions. BACKGROUND: The multicenter and randomized DKCRUSH-V (Double Kissing Crush versus Provisional Stenting for Left Main Distal Bifurcation Lesions: The DKCRUSH-V Randomized Trial) study showed fewer 1-year TLF after DK crush for UPLMb lesions compared with PS. The study reports the 3-year clinical outcome of the DKCRUSH-V study. METHODS: A total of 482 patients with UPLMb lesions who were randomly assigned to either the DK crush group (DK group) or PS group in the DKCRUSH-V study were followed for 3 years. The primary endpoint was the occurrence of a TLF at 3 years. Stent thrombosis (ST) was the safety endpoint. Patients were classified by lesion's complexity and NERS (New Risk Stratification) II or SYNTAX (Synergy Between Percutaneous Coronary Intervention With TAXUS and Cardiac Surgery) score. RESULTS: At 3 years, TLF occurred in 41 (16.9%) patients in the PS group and in 20 (8.3%) patients in the DK group (p = 0.005), mainly driven by increased target vessel myocardial infarction (5.8% vs. 1.7%; p = 0.017) and target lesion revascularization (10.3% vs. 5.0%; p = 0.029). Definite or probable ST rate at 3 years was 4.1% in the PS group and 0.4% in the DK group (p = 0.006). Notably, DK crush was associated with a significant reduction in both primary and secondary endpoints for patients with complex lesions or at high risk. CONCLUSIONS: Provisional stenting for UPLMb lesions was associated with significantly increased rates of TLF and ST over 3 years of follow-up. Further randomized study is warranted to confirm the benefits of DK crush stenting for complex UPLMb lesions. (Double Kissing and Double Crush versus Provisional T Stenting Technique for the Treatment of Unprotected Distal Left Main True Bifurcation Lesions: A Randomized, International, Multi-center Clinical Trial; ChiCTR-TRC-11001213).


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Trombosis Coronaria/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
13.
Int J Cardiol Heart Vasc ; 23: 100358, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31008181

RESUMEN

BACKGROUND: Left atrial appendage closure is a non-pharmacological alternative for stroke prevention in high-risk non-valvular atrial fibrillation patients, but has not been widely studied in Asian patients. The prospective WASP registry assessed real-world outcomes for patients undergoing WATCHMAN implant in the Asia-Pacific region. METHODS: Data were collected from consecutive patients across 9 centres. Major endpoints included procedural success, safety and long-term outcomes including occurrence of bleeding, stroke/transient ischaemic attack/systemic embolism and all-cause mortality. RESULTS: Subjects (n = 201) had a mean age of 70.8 ±â€¯9.4 years, high stroke risk (CHA2DS2-VASc: 3.9 ±â€¯1.7), elevated bleeding risk (HAS-BLED: 2.1 ±â€¯1.2) with 53% patients from Asian countries. Successful implantation occurred in 98.5% of patients; 7-day device/procedure-related SAE rate was 3.0%. After 2 years of follow-up, the rates of ischaemic stroke/TIA/SE and major bleeding were 1.9 and 2.2 per 100-PY, respectively, representing relative reductions of 77% and 49% versus expected rates per risk scores. The relative risk reductions versus expected rates were more pronounced in Asians vs. Non-Asians (89% vs 62%; 77% vs 14%). Other significant findings included larger mean LAA ostium diameter for Asians vs. Non-Asians (23.4 ±â€¯4.1 mm vs. 21.2 ±â€¯3.2 mm, p < 0.001) and hence requirement for larger median device size (27 mm for Asians, 24 mm for non-Asians [p < 0.0001]). CONCLUSION: Real-world experience of left atrial appendage closure with WATCHMAN has demonstrated low peri-procedural risk, and long-term efficacy for stroke and bleeding prevention in a primarily Asian cohort.

14.
Circulation ; 139(14): 1674-1683, 2019 04 02.
Artículo en Inglés | MEDLINE | ID: mdl-30813758

RESUMEN

BACKGROUND: Procedural results for percutaneous coronary intervention (PCI) in coronary vessels with chronic total occlusion (CTO) have improved in recent years, and PCI strategies have moved toward more complete revascularization with more liberal use of CTO-PCI. However, evidence evaluating CTO-PCI is limited to observational studies and small clinical trials. METHODS: In this open-label, multicenter, randomized, noninferiority trial, PCI-eligible patients were assigned to receive either 1 of 2 strategies: PCI or no PCI for the qualifying de novo CTO lesion with the option for PCI of obstructive non-CTO lesions at the discretion of the operator. The primary end point was a composite of death, myocardial infarction, stroke, or any revascularization. Health-related quality of life was assessed at baseline and at 1, 6, 12, 24, and 36 months. Because of slow recruitment, the trial was stopped before completion of the 1284 planned enrollments. RESULTS: Between March 2010 and September 2016, 834 patients were randomly assigned to the CTO-PCI (n=417) or no CTO-PCI (n=398) strategy. Among the patients assigned to the no CTO-PCI strategy, 78 (19.6%) crossed over to receive staged CTO-PCI within 3 days of randomization. The overall CTO-PCI success rate was 90.6%. Serious nonfatal complications associated with CTO-PCI occurred in 3 patients (1 stroke, 1 cardiac tamponade, and 1 patient with recurrent episodes of ventricular tachyarrhythmia induced by intracoronary thrombus). Approximately half of the patients in each group underwent PCI for an average of 1.3 non-CTO lesions, resulting in a comparable residual SYNTAX score (Synergy Between PCI With TAXUS and Cardiac Surgery; 3.7±5.4 versus 4.0±5.9, P=0.42) confined to non-CTO vessels. During a median follow-up of 4.0 years (interquartile range, 2.4 to 5.1 years), there was no significant difference between the CTO-PCI and the no CTO-PCI strategies in the incidence of the primary end point (22.3% versus 22.4%, hazard ratio, 1.03; 95% CI, 0.77 to 1.37; P=0.86). Both CTO-PCI and no CTO-PCI strategy were associated with significant improvements but without between-group differences in disease-specific health status that was sustained through 36 months. CONCLUSIONS: CTO-PCI was feasible with high success rates. There was no difference in the incidence of major adverse cardiovascular events with CTO-PCI versus no CTO-PCI, but the study was limited by low power for clinical end points and high crossover rates between groups. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT01078051.


Asunto(s)
Oclusión Coronaria/terapia , Intervención Coronaria Percutánea , Anciano , Asia/epidemiología , Enfermedad Crónica , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/mortalidad , Stents Liberadores de Fármacos , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Infarto del Miocardio/epidemiología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/mortalidad , Calidad de Vida , Factores de Riesgo , Accidente Cerebrovascular/epidemiología , Taquicardia Ventricular/epidemiología , Factores de Tiempo , Resultado del Tratamiento
15.
Catheter. cardiovasc. interv ; 91(6): 1084-1091, 20180500. tab, graf, ilus
Artículo en Inglés | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1247533

RESUMEN

BACKGROUND: The shear stress distribution assessment can provide useful insights for the hemodynamic performance of the implanted stent/scaffold. Our aim was to investigate the effect of a novel bioresorbable scaffold, Mirage on local hemodynamics in animal models. METHOD: The main epicardial coronary arteries of 7 healthy mini-pigs were implanted with 11 Mirage Microfiber sirolimus-eluting Bioresorbable Scaffolds (MMSES). Optical coherence tomography (OCT) was performed post scaffold implantation and the obtained images were fused with angiographic data to reconstruct the coronary artery anatomy. Blood flow simulation was performed and Endothelial Shear Stress (ESS) distribution was estimated for each of the 11 scaffolds. ESS data were extracted in each circumferential 5-degree subunit of each cross-section in the scaffolded segment. The generalized linear mixed-effect analysis was implemented for the comparison of ESS in two scaffold groups; 150-mm strut thickness MMSES and 125-mm strut thickness MMSES. RESULTS: ESS was significantly higher in MMSES (150 mm) [0.85(0.49­1.40) Pa], compared to MMSES (125 mm) [0.68(0.35­1.18) Pa]. Both MMSES (150 mm) and MMSES (125 mm) revealed low recirculation zone percentages per luminal surface area [3.17% 6 1.97% in MMSES (150 mm), 2.71% 6 1.32% in MMSES (125 mm)]. CONCLUSION: Thinner strut Mirage scaffolds induced lower shear stress due to the small size vessels treated as compared to the thick strut version of the Mirage which was implanted in relatively bigger size vessels. Vessel size should be taken into account in planning BRS implantation. Small vessels may not get benefit from BRS implantation even with a streamlined strut profile. This pilot study warrants comparative assessment with commercially available bioresorbable scaffolds.


Asunto(s)
Masculino , Femenino , Persona de Mediana Edad , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Angioplastia Coronaria con Balón , Stents Liberadores de Fármacos , Hemodinámica
16.
BMJ Open ; 8(3): e020019, 2018 03 06.
Artículo en Inglés | MEDLINE | ID: mdl-29511018

RESUMEN

INTRODUCTION: Provisional stenting (PS) for simple coronary bifurcation lesions is the mainstay of treatment. A systematic two-stent approach is widely used for complex bifurcation lesions (CBLs). However, a randomised comparison of PS and two-stent techniques for CBLs has never been studied. Accordingly, the present study is designed to elucidate the benefits of two-stent treatment over PS in patients with CBLs. METHODS AND ANALYSIS: This DEFINITION II study is a prospective, multinational, randomised, endpoint-driven trial to compare the benefits of the two-stent technique with PS for CBLs. A total of 660 patients with CBLs will be randomised in a 1:1 fashion to receive either PS or the two-stent technique. The primary endpoint is the rate of 12-month target lesion failure defined as the composite of cardiac death, target vessel myocardial infarction (MI) and clinically driven target lesion revascularisation. The major secondary endpoints include all causes of death, MI, target vessel revascularisation, in-stent restenosis, stroke and each individual component of the primary endpoints. The safety endpoint is the occurrence of definite or probable stent thrombosis. ETHICS AND DISSEMINATION: The study protocol and informed consent have been approved by the Institutional Review Board of Nanjing First Hospital, and accepted by each participating centre. Written informed consent was obtained from all enrolled patients. Findings of the study will be published in a peer-reviewed journal and disseminated at conferences. TRIAL REGISTRATION NUMBER: NCT02284750; Pre-results.


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Enfermedad de la Arteria Coronaria/cirugía , Estenosis Coronaria/terapia , Vasos Coronarios/cirugía , Stents , Anciano , Enfermedad de la Arteria Coronaria/patología , Vasos Coronarios/patología , Stents Liberadores de Fármacos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/prevención & control , Intervención Coronaria Percutánea/métodos , Estudios Prospectivos , Diseño de Prótesis , Proyectos de Investigación , Resultado del Tratamiento
17.
Catheter Cardiovasc Interv ; 91(6): 1084-1091, 2018 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-28843033

RESUMEN

BACKGROUND: The shear stress distribution assessment can provide useful insights for the hemodynamic performance of the implanted stent/scaffold. Our aim was to investigate the effect of a novel bioresorbable scaffold, Mirage on local hemodynamics in animal models. METHOD: The main epicardial coronary arteries of 7 healthy mini-pigs were implanted with 11 Mirage Microfiber sirolimus-eluting Bioresorbable Scaffolds (MMSES). Optical coherence tomography (OCT) was performed post scaffold implantation and the obtained images were fused with angiographic data to reconstruct the coronary artery anatomy. Blood flow simulation was performed and Endothelial Shear Stress(ESS) distribution was estimated for each of the 11 scaffolds. ESS data were extracted in each circumferential 5-degree subunit of each cross-section in the scaffolded segment. The generalized linear mixed-effect analysis was implemented for the comparison of ESS in two scaffold groups; 150-µm strut thickness MMSES and 125-µm strut thickness MMSES. RESULTS: ESS was significantly higher in MMSES (150 µm) [0.85(0.49-1.40) Pa], compared to MMSES (125 µm) [0.68(0.35-1.18) Pa]. Both MMSES (150 µm) and MMSES (125 µm) revealed low recirculation zone percentages per luminal surface area [3.17% ± 1.97% in MMSES (150 µm), 2.71% ± 1.32% in MMSES (125 µm)]. CONCLUSION: Thinner strut Mirage scaffolds induced lower shear stress due to the small size vessels treated as compared to the thick strut version of the Mirage which was implanted in relatively bigger size vessels. Vessel size should be taken into account in planning BRS implantation. Small vessels may not get benefit from BRS implantation even with a streamlined strut profile. This pilot study warrants comparative assessment with commercially available bioresorbable scaffolds.


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Vasos Coronarios/cirugía , Hemodinámica , Intervención Coronaria Percutánea/instrumentación , Sirolimus/administración & dosificación , Animales , Velocidad del Flujo Sanguíneo , Simulación por Computador , Circulación Coronaria , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Modelos Animales , Modelos Cardiovasculares , Diseño de Prótesis , Estrés Mecánico , Porcinos , Porcinos Enanos , Factores de Tiempo , Tomografía de Coherencia Óptica
18.
J Am Coll Cardiol ; 70(21): 2605-2617, 2017 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-29096915

RESUMEN

BACKGROUND: Provisional stenting (PS) is the most common technique used to treat distal left main (LM) bifurcation lesions in patients with unprotected LM coronary artery disease undergoing percutaneous coronary intervention. The double kissing (DK) crush planned 2-stent technique has been shown to improve clinical outcomes in non-LM bifurcations compared with PS, and in LM bifurcations compared with culotte stenting, but has never been compared with PS in LM bifurcation lesions. OBJECTIVES: The authors sought to determine whether a planned DK crush 2-stent technique is superior to PS for patients with true distal LM bifurcation lesions. METHODS: The authors randomized 482 patients from 26 centers in 5 countries with true distal LM bifurcation lesions (Medina 1,1,1 or 0,1,1) to PS (n = 242) or DK crush stenting (n = 240). The primary endpoint was the 1-year composite rate of target lesion failure (TLF): cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization. Routine 13-month angiographic follow-up was scheduled after ascertainment of the primary endpoint. RESULTS: TLF within 1 year occurred in 26 patients (10.7%) assigned to PS, and in 12 patients (5.0%) assigned to DK crush (hazard ratio: 0.42; 95% confidence interval: 0.21 to 0.85; p = 0.02). Compared with PS, DK crush also resulted in lower rates of target vessel myocardial infarction I (2.9% vs. 0.4%; p = 0.03) and definite or probable stent thrombosis (3.3% vs. 0.4%; p = 0.02). Clinically driven target lesion revascularization (7.9% vs. 3.8%; p = 0.06) and angiographic restenosis within the LM complex (14.6% vs. 7.1%; p = 0.10) also tended to be less frequent with DK crush compared with PS. There was no significant difference in cardiac death between the groups. CONCLUSIONS: In the present multicenter randomized trial, percutaneous coronary intervention of true distal LM bifurcation lesions using a planned DK crush 2-stent strategy resulted in a lower rate of TLF at 1 year than a PS strategy. (Double Kissing and Double Crush Versus Provisional T Stenting Technique for the Treatment of Unprotected Distal Left Main True Bifurcation Lesions: A Randomized, International, Multi-Center Clinical Trial [DKCRUSH-V]; ChiCTR-TRC-11001213).


Asunto(s)
Enfermedad de la Arteria Coronaria/cirugía , Intervención Coronaria Percutánea/métodos , Stents , Anciano , Angiografía , Angioplastia Coronaria con Balón/métodos , Reestenosis Coronaria/cirugía , Estenosis Coronaria/cirugía , Stents Liberadores de Fármacos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/cirugía , Revascularización Miocárdica , Trombosis , Resultado del Tratamiento
20.
JACC Cardiovasc Interv ; 10(11): 1115-1130, 2017 06 12.
Artículo en Inglés | MEDLINE | ID: mdl-28527768

RESUMEN

OBJECTIVES: The primary objective of this study was to evaluate the safety and effectiveness of the Mirage (Manli Cardiology, Singapore) bioresorbable microfiber sirolimus-eluting scaffold compared with the Absorb (Abbott Vascular, Santa Clara, California) bioresorbable vascular scaffold in the treatment of stenotic target lesions located in native coronary arteries, ranging from ≥2.25 to ≤4.0 mm in diameter. Secondary objectives were to establish the medium-term safety, effectiveness, and performance of the Mirage device. BACKGROUND: The current generation of bioresorbable scaffolds has several limitations, such as thick square struts with large footprints that preclude their deep embedment into the vessel wall, resulting in protrusion into the lumen with microdisturbance of flow. The Mirage sirolimus-eluting bioresorbable microfiber scaffold is designed to address these concerns. METHODS: In this prospective, single-blind trial, 60 patients were randomly allocated in a 1:1 ratio to treatment with a Mirage sirolimus-eluting bioresorbable microfiber scaffold or an Absorb bioresorbable vascular scaffold. The clinical endpoints were assessed at 30 days and at 6 and 12 months. In-device angiographic late loss at 12 months was quantified. Secondary optical coherence tomographic endpoints were assessed post-scaffold implantation at 6 and 12 months. RESULTS: Median angiographic post-procedural in-scaffold minimal luminal diameters of the Mirage and Absorb devices were 2.38 mm (interquartile range [IQR]: 2.06 to 2.62 mm) and 2.55 mm (IQR: 2.26 to 2.71 mm), respectively; the effect size (d) was -0.29. At 12 months, median angiographic in-scaffold minimal luminal diameters of the Mirage and Absorb devices were not statistically different (1.90 mm [IQR: 1.57 to 2.31 mm] vs. 2.29 mm [IQR: 1.74 to 2.51 mm], d = -0.36). At 12-month follow-up, median in-scaffold late luminal loss with the Mirage and Absorb devices was 0.37 mm (IQR: 0.08 to 0.72 mm) and 0.23 mm (IQR: 0.15 to 0.37 mm), respectively (d = 0.20). On optical coherence tomography, post-procedural diameter stenosis with the Mirage was 11.2 ± 7.1%, which increased to 27.4 ± 12.4% at 6 months and remained stable (31.8 ± 12.9%) at 1 year, whereas the post-procedural optical coherence tomographic diameter stenosis with the Absorb was 8.4 ± 6.6%, which increased to 16.6 ± 8.9% and remained stable (21.2 ± 9.9%) at 1-year follow-up (Mirage vs. Absorb: dpost-procedure = 0.41, d6 months = 1.00, d12 months = 0.92). Angiographic median in-scaffold diameter stenosis was significantly different between study groups at 12 months (28.6% [IQR: 21.0% to 40.7%] for the Mirage, 18.2% [IQR: 13.1% to 31.6%] for the Absorb, d = 0.39). Device- and patient-oriented composite endpoints were comparable between the 2 study groups. CONCLUSIONS: At 12 months, angiographic in-scaffold late loss was not statistically different between the Mirage and Absorb devices, although diameter stenosis on angiography and on optical coherence tomography was significantly higher with the Mirage than with the Absorb. The technique of implantation was suboptimal for both devices, and future trials should incorporate optical coherence tomographic guidance to allow optimal implantation and appropriate assessment of the new technology, considering the novel mechanical properties of the Mirage.


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Angiografía Coronaria , Estenosis Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Imagen Multimodal/métodos , Intervención Coronaria Percutánea/instrumentación , Sirolimus/administración & dosificación , Tomografía de Coherencia Óptica , Fármacos Cardiovasculares/efectos adversos , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Estenosis Coronaria/diagnóstico por imagen , Femenino , Humanos , Indonesia , Malasia , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Método Simple Ciego , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...