Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Clin. transl. oncol. (Print) ; 15(4): 283-293, abr. 2013. tab, ilus
Artículo en Inglés | IBECS | ID: ibc-127219

RESUMEN

PURPOSE: There are several potential advantages of using 18-fluor-fluorodeoxiglucose (18F-FDG) PET for target volume contouring, but before PET-based gross tumor volumes (GTVs) can reliably and reproducibly be incorporated into high-precision radiotherapy planning, operator-independent segmentation tools have to be developed and validated. The purpose of the present work was to apply the adaptive to the signal/background ratio (R(S/B)) thresholding method for head and neck tumor delineation, and compare these GTV(PET) to reference GTV(CT) volumes in order to assess discrepancies. MATERIALS AND METHODS: A cohort of 19 patients (39 lesions) with a histological diagnosis of head and neck cancer who would undergo definitive concurrent radiochemotherapy or radical radiotherapy with intensity-modulated radiotherapy technique (IMRT), were enrolled in this prospective study. Contouring on PET images was accomplished through standardized uptake value (SUV)-threshold definition. The threshold value was adapted to R(S/B). To determine the relationship between the threshold and the R(S/B), we performed a phantom study. A discrepancy index (DI) between both imaging modalities, overlap fraction (OF) and mismatch fraction (MF) were calculated for each lesion and imaging modality. RESULTS: The median DI value for lymph nodes was 2.67 and 1.76 for primary lesions. The OF values were larger for CT volumes than for PET volumes (p < 0.001), for both types of lesions. The MF values were smaller for CT volumes than for PET volumes (p < 0.001), for both types of lesions. The GTV(PET) coverage (OF(PET)) was strongly correlated with the lesion volume (GTV(CT)) for metastatic lymph nodes (Pearson correlation = 0.665; p < 0.01). For smaller lesions, despite the GTV volumes were relatively larger on PET than in CT contours, the coverage was poorer. Accordingly, the MF(PET/CT) was negatively correlated with the lesion volume for metastatic lymph nodes. CONCLUSIONS: The present study highlights the considerable challenges involved in using FDG PET imaging for the delineation of GTV in head and neck neoplasms. The methods that rely mainly on SUV(max) for thresholding, as the RS/B method, are very sensitive to partial volume effects and may provide unreliable results when applied on small lesions (AU)


Asunto(s)
Humanos , Masculino , Femenino , Neoplasias de Cabeza y Cuello/tratamiento farmacológico , Neoplasias de Cabeza y Cuello/metabolismo , Neoplasias de Cabeza y Cuello/patología , Neoplasias de Cabeza y Cuello/radioterapia , Neoplasias de Cabeza y Cuello/cirugía , Neoplasias de Cabeza y Cuello/diagnóstico , Ganglios Linfáticos
2.
Clin. transl. oncol. (Print) ; 11(9): 615-621, sept. 2009. tab, ilus
Artículo en Inglés | IBECS | ID: ibc-123685

RESUMEN

PURPOSE: To determine the magnitude of setup and organ motion errors from a subset of prostate cancer patients treated with conventional conformal radiotherapy, and to estimate the CTV-PTV margin according to published margin recipes. METHODS AND MATERIALS: Twenty prostate cancer patients were treated with external radiotherapy using electronic portal images (EPIs). Weekly treatment EPIs and pelvic CT scans were obtained. These data allowed interfractional analysis of prostate centre of mass motion and setup error. The margins needed to compensate these uncertainties were calculated. RESULTS: Tattoo localisation requires a margin of 9-10.5 mm (LR), 15.2-17.8 mm (anterior-posterior (AP)) and 10.6-12.4 mm (superior-inferior (S-I)). Systematic displacements due to prostatic motion, with standard deviations of 2.4 mm (LR), 4.2 mm (AP) and 3.1 mm (S-I) were found to be larger than setup errors (1.8, 3.0 and 1.7 mm respectively). CONCLUSIONS: Customised PTV margin definition has been possible through in-house measurements of geometrical clinical uncertainties involved in the conventional conformal radiotherapy process. Uncertainty measurements in our department have proved to be larger than those used in common practice. Additional margin reduction procedures are needed in order to accomplish conformal radiotherapy goals (AU)


Asunto(s)
Humanos , Masculino , Radioterapia Asistida por Computador/métodos , Radioterapia Conformacional/métodos , Radioterapia Conformacional , Carcinoma/radioterapia , Próstata/patología , Neoplasias de la Próstata/radioterapia , Tomografía Computarizada por Rayos X/métodos , Carga Tumoral/efectos de la radiación , Carcinoma/patología , Estudios de Cohortes , Diagnóstico por Imagen/métodos , Imagenología Tridimensional/métodos , Errores Médicos/estadística & datos numéricos , Próstata/efectos de la radiación , Neoplasias de la Próstata/patología , Pelvis/patología , Incertidumbre , Tamaño de los Órganos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...