Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Transfusion ; 63 Suppl 4: S19-S42, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37702255

RESUMEN

BACKGROUND: The Department of Health and Human Services' National Blood Collection and Utilization Survey (NBCUS) has been conducted biennially since 1997. Data are used to estimate national blood collection and use. Supplemental data from the 2021 NBCUS not presented elsewhere are presented here. METHODS: Data on survey participation, donor characteristics, blood component cost, transfusion-associated adverse reactions, and implementation of blood safety measures, including pathogen-reduction of platelets, during 2021, were analyzed. Comparisons are made to 2019 survey data where available (2013-2019 for survey participation). RESULTS: During 2021, there were 11,507,000 successful blood donations in the United States, a 4.8% increase from 2019. Persons aged 45-64 years accounted for 42% of all successful blood donations. Donations by persons aged 65 years and older increased by 40.7%, while donations among minorities and donors aged <25 years decreased. From 2019 to 2021, the median price hospitals paid per unit of leukoreduced red blood cells, leukoreduced and pathogen-reduced apheresis platelets, and fresh frozen plasma increased. The largest increase in price per unit of blood component in 2021 was for leukoreduced apheresis platelets, which increased by ~$51. Between 2019 and 2021, the proportion of transfusing facilities reporting use of pathogen-reduced platelets increased, from 13% to 60%. Transfusion-related adverse reactions declined slightly between 2019 and 2021, although the rate of transfusion-transmitted bacterial infections remained unchanged. CONCLUSION: During 2021, blood donations increased nationally, although donations from those aged <25 years and minorities declined. The prices hospitals paid for most blood products increased, as did the use of pathogen-reduced platelets.


Asunto(s)
Eliminación de Componentes Sanguíneos , Reacción a la Transfusión , Humanos , Estados Unidos , Plaquetas , Transfusión de Componentes Sanguíneos , Donantes de Sangre
2.
Open Forum Infect Dis ; 10(5): ofad218, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37187509

RESUMEN

Background: Most multicenter studies of US pediatric sepsis epidemiology use administrative data or focus on pediatric intensive care units. We conducted a detailed medical record review to describe sepsis epidemiology in children and young adults. Methods: In a convenience sample of hospitals in 10 states, patients aged 30 days-21 years, discharged during 1 October 2014-30 September 2015, with explicit diagnosis codes for severe sepsis or septic shock, were included. Medical records were reviewed for patients with documentation of sepsis, septic shock, or similar terms. We analyzed overall and age group-specific patient characteristics. Results: Of 736 patients in 26 hospitals, 442 (60.1%) had underlying conditions. Most patients (613 [83.3%]) had community-onset sepsis, although most community-onset sepsis was healthcare associated (344 [56.1%]). Two hundred forty-one patients (32.7%) had outpatient visits 1-7 days before sepsis hospitalization, of whom 125 (51.9%) received antimicrobials ≤30 days before sepsis hospitalization. Age group-related differences included common underlying conditions (<5 years: prematurity vs 5-12 years: chronic pulmonary disease vs 13-21 years: chronic immunocompromise); medical device presence ≤30 days before sepsis hospitalization (1-4 years: 46.9% vs 30 days-11 months: 23.3%); percentage with hospital-onset sepsis (<5 years: 19.6% vs ≥5 years: 12.0%); and percentage with sepsis-associated pathogens (30 days-11 months: 65.6% vs 13-21 years: 49.3%). Conclusions: Our data suggest potential opportunities to raise sepsis awareness among outpatient providers to facilitate prevention, early recognition, and intervention in some patients. Consideration of age-specific differences may be important as approaches are developed to improve sepsis prevention, risk prediction, recognition, and management.

3.
Transfusion ; 63 Suppl 4: S8-S18, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37070720

RESUMEN

BACKGROUND: National Blood Collection and Utilization Surveys (NBCUS) have reported decreases in U.S. blood collections and transfusions since 2008. The declines began to stabilize in 2015-2017, with a subsequent increase in transfusions in 2019. Data from the 2021 NBCUS were analyzed to understand the current dynamics of blood collection and use in the United States. METHODS: In March 2022, all community-based (53) and hospital-based (83) blood collection centers, a randomly selected 40% of transfusing hospitals performing 100-999 annual inpatient surgeries, and all transfusing hospitals performing ≥1000 annual inpatient surgeries were sent a 2021 NBCUS survey to ascertain blood collection and transfusion data. Responses were compiled, and national estimates were calculated for the number of units of blood and blood components collected, distributed, transfused, and outdated in 2021. Weighting and imputation were applied to account for non-responses and missing data, respectively. RESULTS: Survey response rates were 92.5% (49/53) for community-based blood centers, 74.7% (62/83) for hospital-based blood centers, and 76.3% (2102/2754) for transfusing hospitals. Overall, 11,784,000 (95% confidence interval [CI], 11,392,000-12,177,000) whole blood and apheresis red blood cell (RBC) units were collected in 2021, a 1.7% increase from 2019; 10,764,000 (95% CI, 10,357,000-11,171,000) whole blood-derived and apheresis RBC units were transfused, a 0.8% decrease. Total platelet units distributed increased by 0.8%; platelet units transfused decreased by 3.0%; plasma units distributed increased by 16.2%; and plasma units transfused increased by 1.4%. DISCUSSION: The 2021 NBCUS findings demonstrate a stabilization in U.S. blood collections and transfusions, suggesting a plateau has been reached for both.


Asunto(s)
Bancos de Sangre , Transfusión Sanguínea , Humanos , Estados Unidos , Transfusión de Componentes Sanguíneos , Encuestas y Cuestionarios , Plasma
4.
Transfusion ; 63 Suppl 4: S1-S7, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37052192

RESUMEN

INTRODUCTION: Reports have suggested the COVID-19 pandemic resulted in blood donation shortages and adverse impacts on the blood supply. Using data from the National Blood Collection and Utilization Survey (NBCUS), we quantified the pandemic's impact on red blood cell (RBC) and apheresis platelet collections and transfusions in the United States during year 2020. METHODS: The 2021 NBCUS survey instrument was modified to include certain blood collection and utilization variables for 2020. The survey was distributed to all US blood collection centers, all US hospitals performing ≥1000 surgeries annually, and a 40% random sample of hospitals performing 100-999 surgeries annually. Weighting and imputation were used to generate national estimates for whole blood and apheresis platelet donation; RBC and platelet transfusion; and convalescent plasma distribution. RESULTS: Whole blood collections were stable from 2019 (9,790,000 units; 95% CI: 9,320,000-10,261,000) to 2020 (9,738,000 units; 95% CI: 9,365,000-10,110,000). RBC transfusions decreased by 6.0%, from 10,852,000 units (95% CI: 10,444,000-11,259,000) in 2019 to 10,202,000 units (95% CI: 9,811,000-10,593,000) in 2020. Declines were steepest during March-April 2020, with transfusions subsequently rebounding. Apheresis platelet collections increased from 2,359,000 units (95% CI: 2,240,000-2,477,000) in 2019 to 2,408,000 units (95% CI: 2,288,000-2,528,000) in 2020. Apheresis platelet transfusions increased from 1,996,000 units (95% CI: 1,846,000-2,147,000) in 2019 to 2,057,000 units (95% CI: 1,902,000-2,211,000) in 2020. CONCLUSION: The COVID-19 pandemic resulted in reduced blood donations and transfusions in some months during 2020 but only a minimal annualized decline compared with 2019.


Asunto(s)
COVID-19 , Pandemias , Humanos , Estados Unidos/epidemiología , Donación de Sangre , Bancos de Sangre , COVID-19/epidemiología , COVID-19/terapia , Sueroterapia para COVID-19
5.
J Public Health Manag Pract ; 28(6): 712-719, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36194816

RESUMEN

CONTEXT: Mask mandates are one form of nonpharmaceutical intervention that has been utilized to combat the spread of SARS-CoV2, the virus that causes COVID-19. OBJECTIVE: This study examines the association between state-issued mask mandates and changes in county-level and hospital referral region (HRR)-level COVID-19 hospitalizations across the United States. DESIGN: Difference-in-difference and event study models were estimated to examine the association between state-issued mask mandates and COVID-19 hospitalization outcomes. PARTICIPANTS: All analyses were conducted with US county-level data. INTERVENTIONS: State-issued mask mandates. County-level data on the mandates were collected from executive orders identified on state government Web sites from April 1, 2020, to December 31, 2020. MAIN OUTCOME MEASURES: Daily county-level (and HRR-level) estimates of inpatient beds occupied by patients with confirmed or suspected COVID-19 were collected by the US Department of Health and Human Services. RESULTS: The state issuing of mask mandates was associated with an average of 3.6 fewer daily COVID-19 hospitalizations per 100 000 people (P < .05) and a 1.2-percentage-point decrease in the percentage of county beds occupied with COVID-19 patients (P < .05) within 70 days of taking effect. Event study results suggest that this association increased the longer mask mandates were in effect. In addition, the results were robust to analyses conducted at the HRR level. CONCLUSIONS: This study demonstrated that state-issued mask mandates were associated with reduction in COVID-19 hospitalizations across the United States during the earlier portion of the pandemic. As new variants of the virus cause spikes in COVID-19 cases, reimposing mask mandates in indoor and congested public areas, as part of a layered approach to community mitigation, may reduce the spread of COVID-19 and lessen the burden on our health care system.


Asunto(s)
COVID-19 , COVID-19/epidemiología , COVID-19/prevención & control , Hospitalización , Humanos , Máscaras , Pandemias , ARN Viral , SARS-CoV-2 , Estados Unidos/epidemiología
6.
Infect Control Hosp Epidemiol ; 43(10): 1473-1476, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-34167599

RESUMEN

During March 27-July 14, 2020, the Centers for Disease Control and Prevention's National Healthcare Safety Network extended its surveillance to hospital capacities responding to COVID-19 pandemic. The data showed wide variations across hospitals in case burden, bed occupancies, ventilator usage, and healthcare personnel and supply status. These data were used to inform emergency responses.


Asunto(s)
COVID-19 , Humanos , Estados Unidos/epidemiología , Pandemias/prevención & control , Centers for Disease Control and Prevention, U.S. , Hospitales , Atención a la Salud
7.
Infect Control Hosp Epidemiol ; 43(1): 32-39, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33602380

RESUMEN

OBJECTIVE: The rapid spread of severe acute respiratory coronavirus virus 2 (SARS-CoV-2) throughout key regions of the United States in early 2020 placed a premium on timely, national surveillance of hospital patient censuses. To meet that need, the Centers for Disease Control and Prevention's National Healthcare Safety Network (NHSN), the nation's largest hospital surveillance system, launched a module for collecting hospital coronavirus disease 2019 (COVID-19) data. We present time-series estimates of the critical hospital capacity indicators from April 1 to July 14, 2020. DESIGN: From March 27 to July 14, 2020, the NHSN collected daily data on hospital bed occupancy, number of hospitalized patients with COVID-19, and the availability and/or use of mechanical ventilators. Time series were constructed using multiple imputation and survey weighting to allow near-real-time daily national and state estimates to be computed. RESULTS: During the pandemic's April peak in the United States, among an estimated 431,000 total inpatients, 84,000 (19%) had COVID-19. Although the number of inpatients with COVID-19 decreased from April to July, the proportion of occupied inpatient beds increased steadily. COVID-19 hospitalizations increased from mid-June in the South and Southwest regions after stay-at-home restrictions were eased. The proportion of inpatients with COVID-19 on ventilators decreased from April to July. CONCLUSIONS: The NHSN hospital capacity estimates served as important, near-real-time indicators of the pandemic's magnitude, spread, and impact, providing quantitative guidance for the public health response. Use of the estimates detected the rise of hospitalizations in specific geographic regions in June after they declined from a peak in April. Patient outcomes appeared to improve from early April to mid-July.


Asunto(s)
COVID-19 , Ocupación de Camas , Hospitalización , Hospitales , Humanos , SARS-CoV-2 , Estados Unidos/epidemiología
8.
Transfusion ; 61 Suppl 2: S11-S35, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34337759

RESUMEN

INTRODUCTION: Supplemental data from the 2019 National Blood Collection and Utilization Survey (NBCUS) are presented and include findings on donor characteristics, autologous and directed donations and transfusions, platelets (PLTs), plasma and granulocyte transfusions, pediatric transfusions, transfusion-associated adverse events, cost of blood units, hospital policies and practices, and implementation of blood safety measures, including pathogen reduction technology (PRT). METHODS: National estimates were produced using weighting and imputation methods for a number of donors, donations, donor deferrals, autologous and directed donations and transfusions, PLT and plasma collections and transfusions, a number of crossmatch procedures, a number of units irradiated and leukoreduced, pediatric transfusions, and transfusion-associated adverse events. RESULTS: Between 2017 and 2019, there was a slight decrease in successful donations by 1.1%. Donations by persons aged 16-18 decreased by 10.1% while donations among donors >65 years increased by 10.5%. From 2017 to 2019, the median price paid for blood components by hospitals for leukoreduced red blood cell units, leukoreduced apheresis PLT units, and for fresh frozen plasma units continued to decrease. The rate of life-threatening transfusion-related adverse reactions continued to decrease. Most whole blood/red blood cell units (97%) and PLT units (97%) were leukoreduced. CONCLUSION: Blood donations decreased between 2017 and 2019. Donations from younger donors continued to decline while donations among older donors have steadily increased. Prices paid for blood products by hospitals decreased. Implementation of PRT among blood centers and hospitals is slowly expanding.


Asunto(s)
Donantes de Sangre/estadística & datos numéricos , Encuestas de Atención de la Salud , Adolescente , Adulto , Distribución por Edad , Anciano , Bancos de Sangre/estadística & datos numéricos , Eliminación de Componentes Sanguíneos/estadística & datos numéricos , Transfusión de Componentes Sanguíneos/estadística & datos numéricos , Transfusión de Componentes Sanguíneos/tendencias , Donantes de Sangre/provisión & distribución , Antígenos de Grupos Sanguíneos/genética , Transfusión Sanguínea/estadística & datos numéricos , Transfusión Sanguínea/tendencias , Transfusión de Sangre Autóloga/estadística & datos numéricos , Transfusión de Sangre Autóloga/tendencias , Áreas de Influencia de Salud , Niño , Preescolar , Transmisión de Enfermedad Infecciosa/prevención & control , Selección de Donante/estadística & datos numéricos , Femenino , Costos de la Atención en Salud , Hospitales/estadística & datos numéricos , Humanos , Lactante , Recién Nacido , Procedimientos de Reducción del Leucocitos/economía , Procedimientos de Reducción del Leucocitos/métodos , Masculino , Persona de Mediana Edad , Política Organizacional , Asunción de Riesgos , Muestreo , Procedimientos Quirúrgicos Operativos/estadística & datos numéricos , Reacción a la Transfusión/epidemiología , Estados Unidos/epidemiología , Adulto Joven
9.
Transfusion ; 61 Suppl 2: S1-S10, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34165191

RESUMEN

INTRODUCTION: Previous iterations of National Blood Collection and Utilization Survey (NBCUS) have demonstrated declines in blood collection and transfusion in the United States since 2008, including declines of 3.0% and 6.1% in red blood cell (RBC) collections and transfusions between 2015 and 2017, respectively. This study describes results of the 2019 NBCUS. METHODS: The survey was distributed to all US blood collection centers, all hospitals performing ≥1000 surgeries annually, and a 40% random sample of hospitals performing 100-999 surgeries annually. Weighting and imputation were used to generate national estimates for units of blood and components collected, distributed, transfused, and outdated. RESULTS: In 2019, 11,590,000 RBC units were collected (95% confidence interval [CI], 11,151,000-12,029,000 units), a 5.1% decrease compared with 2017, while 10,852,000 RBC units were transfused (95% CI, 10,444-11,259 units), a 2.5% increase from 2017. Between 2017 and 2019, platelet distributions (2,508,000 units; 95% CI, 2,375,000-2,641,000 units) decreased by 2.0%, and plasma distributions (2,679,000 units; 95% CI, 2,525,000-2,833,000 units) decreased by 16.5%. During the same time period, platelet transfusions (2,243,000 units; 95% CI, 1,846,000-2,147,000 units) increased by 15.8% and plasma transfusions (2,185,000 units; 95% CI, 2,068,000-2,301,000 units) decreased by 8.0%. CONCLUSION: Utilization of RBC in the United States might have reached a nadir. Between 2017 and 2019, RBC collections declined while RBC transfusions did not significantly change, suggesting a narrowing between blood supply and demand. Monitoring national blood collection and utilization data is integral to understanding trends in blood supply safety and availability.


Asunto(s)
Transfusión Sanguínea/tendencias , Encuestas de Atención de la Salud , Bancos de Sangre/estadística & datos numéricos , Transfusión de Componentes Sanguíneos/estadística & datos numéricos , Transfusión de Componentes Sanguíneos/tendencias , Donantes de Sangre/estadística & datos numéricos , Pérdida de Sangre Quirúrgica , Transfusión Sanguínea/estadística & datos numéricos , Hospitales/estadística & datos numéricos , Humanos , Cuidados Intraoperatorios/estadística & datos numéricos , Muestreo , Procedimientos Quirúrgicos Operativos/estadística & datos numéricos , Estados Unidos
10.
Transfus Med Rev ; 35(2): 78-84, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33934903

RESUMEN

Despite advances in transfusion safety, concerns with safety of platelet transfusions remain including platelet-related sepsis and higher reaction rates observed among patients receiving apheresis platelets (APLTs). National Healthcare Safety Network (NHSN) Hemovigilance Module (HM) data were analyzed to quantify the burden and severity of adverse reactions occurring from APLTs and whole blood-derived platelets (WBD-PLTs). Facilities participating in NHSN HM during 2010-2018 were included. Adverse reaction rates (number per 100,000 components transfused) were calculated for APLTs and WBD-PLTs stratified by severity, use of platelet additive solution (PAS), and pathogen reduction technology (PRT). Chi-square tests were used to compare rates. During the study interval, 2,000,589 platelets were transfused: 1,435,154 APLTs; 525,902 WBD-PLTs; and among APLTs, 39,533 PRT-APLTs. APLT adverse reaction rates were higher (478 vs 70/ 100,000, P< .01) and more often serious (34 vs 6/100,000; P< .01) compared with WBD-PLTs. Adverse reactions were higher among PRT-APLTs (572/100,000) and were less often serious (18/100,000) compared with non-PRT-APLTs (35/100,000) although this association was not statistically significant. Among components implicated in adverse reactions, 92% of APLTs were suspended in plasma. Compared with PRT-APLTs stored in PAS, rates were higher among units stored in plasma (760 vs 525/100,000). Most serious reactions (75%) were allergic. No transfusion-transmitted infections were reported among PRT-APLTs. APLTs were associated with a 6-fold and 2-fold higher serious adverse reaction risks compared with WBD-PLTs and PRT-APLTs, respectively. These findings demonstrate the importance of monitoring transfusion-related adverse reactions to track the safety of platelet transfusions and quantify the impact of mitigation strategies through national hemovigilance systems.


Asunto(s)
Eliminación de Componentes Sanguíneos , Seguridad de la Sangre , Eliminación de Componentes Sanguíneos/efectos adversos , Plaquetas , Atención a la Salud , Humanos , Tecnología
11.
Transfusion ; 61(5): 1424-1434, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33880771

RESUMEN

BACKGROUND: Despite current blood safety measures, transfusion recipients can experience transfusion-related adverse reactions. Monitoring these reactions can aid in understanding the effectiveness of current transfusion safety measures. Data from the National Healthcare Safety Network Hemovigilance Module were used to quantify adverse reaction risk. METHODS: Facilities reporting at least one month of transfused blood components and transfusion-related adverse reactions during January 2013-December 2018 were included. Adverse reaction rates (number per 100,000 components transfused) were calculated for transfused components stratified by component type, collection, and modification methods. RESULTS: During 2013-2018, 201 facilities reported 18,308 transfusion-related adverse reactions among 8.34 million blood components transfused (220/100,000). Adverse reactions were higher among apheresis (486/100,000) and pathogen-reduced platelets (579/100,000) than apheresis red blood cells (197/100,000). Allergic reactions (41%) were most common. There were 23 fatalities and 9% of all adverse reactions were serious (severe, life-threatening, or fatal). Reactions involving pulmonary complications (transfusion-associated circulatory overload, transfusion-related acute lung injury and transfusion-associated dyspnea) accounted for 35% of serious reactions but 65% of fatalities. Most (76%) of the 37 transfusion-transmitted infections were serious; none involved pathogen-reduced components. CONCLUSIONS: One in 455 blood components transfused was associated with an adverse reaction although the risk of serious reactions (1 in 6224) or transfusion-transmitted infections (1 in 225,440) was lower. Some serious reactions identified were preventable, suggesting additional safety measures may be beneficial. Higher reaction rates identified among pathogen-reduced platelets require further study. These findings highlight the importance of monitoring reactions through national hemovigilance to inform current safety measures and the need for strategies to increase healthcare facility participation.


Asunto(s)
Transfusión de Componentes Sanguíneos/efectos adversos , Seguridad de la Sangre/efectos adversos , Reacción a la Transfusión/epidemiología , Eliminación de Componentes Sanguíneos/efectos adversos , Transfusión Sanguínea , Humanos , Lesión Pulmonar Aguda Postransfusional/epidemiología , Estados Unidos/epidemiología
12.
Transpl Infect Dis ; 23(4): e13589, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33617680

RESUMEN

Liver transplant recipients are at high risk for surgical site infections (SSIs). Limited data are available on SSI epidemiology following liver transplant procedures (LTPs). We analyzed data on SSIs from 2015 to 2018 reported to CDC's National Healthcare Safety Network to determine rates, pathogen distribution, and antimicrobial resistance after LTPs and other hepatic, biliary, or pancreatic procedures (BILIs). LTP and BILI SSI rates were 5.7% and 5.9%, respectively. The odds of SSI after LTP were lower than after BILI (adjusted odds ratio = 0.70, 95% confidence interval 0.57-0.85). Among LTP SSIs, 43.1% were caused by Enterococcus spp., 17.2% by Candida spp., and 15.0% by coagulase-negative Staphylococcus spp. (CNS). Percentages of SSIs caused by Enterococcus faecium or CNS were higher after LTPs than BILIs, whereas percentages of SSIs caused by Enterobacteriaceae, Enterococcus faecalis, or viridans streptococci were higher after BILIs. Antimicrobial resistance was common in LTP SSI pathogens, including E. faecium (69.4% vancomycin resistant); Escherichia coli (68.8% fluoroquinolone non-susceptible and 44.7% extended spectrum cephalosporin [ESC] non-susceptible); and Klebsiella pneumoniae and K. oxytoca (39.4% fluoroquinolone non-susceptible and 54.5% ESC non-susceptible). National LTP SSI pathogen and resistance data can help prioritize studies to determine effective interventions to prevent SSIs and reduce antimicrobial resistance in liver transplant recipients.


Asunto(s)
Trasplante de Hígado , Infección de la Herida Quirúrgica , Antibacterianos/uso terapéutico , Enterococcus faecalis , Humanos , Klebsiella pneumoniae , Trasplante de Hígado/efectos adversos , Staphylococcus , Infección de la Herida Quirúrgica/tratamiento farmacológico , Infección de la Herida Quirúrgica/epidemiología
13.
JAMA Netw Open ; 3(7): e206004, 2020 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-32633762

RESUMEN

Importance: Current information on the characteristics of patients who develop sepsis may help in identifying opportunities to improve outcomes. Most recent studies of sepsis epidemiology have focused on changes in incidence or have used administrative data sets that provided limited patient-level data. Objective: To describe sepsis epidemiology in adults. Design, Setting, and Participants: This retrospective cohort study reviewed the medical records, death certificates, and hospital discharge data of adult patients with sepsis or septic shock who were discharged from the hospital between October 1, 2014, and September 30, 2015. The convenience sample was obtained from hospitals in the Centers for Disease Control and Prevention Emerging Infections Program in 10 states (California, Colorado, Connecticut, Georgia, Maryland, Minnesota, New Mexico, New York, Oregon, and Tennessee). Patients 18 years and older with discharge diagnosis codes for severe sepsis or septic shock were randomly selected. Data were analyzed between May 1, 2018, and January 31, 2019. Main Outcomes and Measures: The population's demographic characteristics, health care exposures, and sepsis-associated infections and pathogens were described, and risk factors for death within 30 days after sepsis diagnosis were assessed. Results: Among 1078 adult patients with sepsis (569 men [52.8%]; median age, 64 years [interquartile range, 53-75 years]), 973 patients (90.3%) were classified as having community-onset sepsis (ie, sepsis diagnosed within 3 days of hospital admission). In total, 654 patients (60.7%) had health care exposures before their hospital admission for sepsis; 260 patients (24.1%) had outpatient encounters in the 7 days before admission, and 447 patients (41.5%) received medical treatment, including antimicrobial drugs, chemotherapy, wound care, dialysis, or surgery, in the 30 days before admission. A pathogen associated with sepsis was found in 613 patients (56.9%); the most common pathogens identified were Escherichia coli, Staphylococcus aureus, Klebsiella pneumoniae, and Clostridioides difficile. After controlling for other factors, an association was found between underlying comorbidities, such as cirrhosis (odds ratio, 3.59; 95% CI, 2.03-6.32), immunosuppression (odds ratio, 2.52; 95% CI, 1.81-3.52), vascular disease (odds ratio, 1.54; 95% CI, 1.10-2.15), and 30-day mortality. Conclusions and Relevance: Most adults experienced sepsis onset outside of the hospital and had recent encounters with the health care system. A sepsis-associated pathogen was identified in more than half of patients. Future efforts to improve sepsis outcomes may benefit from examination of health maintenance practices and recent health care exposures as potential opportunities among high-risk patients.


Asunto(s)
Infección Hospitalaria , Hospitalización/estadística & datos numéricos , Sepsis , Choque Séptico , Causalidad , Estudios de Cohortes , Infección Hospitalaria/epidemiología , Infección Hospitalaria/terapia , Exposición a Riesgos Ambientales/análisis , Exposición a Riesgos Ambientales/estadística & datos numéricos , Femenino , Mortalidad Hospitalaria , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Evaluación de Procesos y Resultados en Atención de Salud , Factores de Riesgo , Sepsis/mortalidad , Sepsis/terapia , Choque Séptico/mortalidad , Choque Séptico/terapia , Estados Unidos/epidemiología
14.
Transfusion ; 60 Suppl 2: S17-S37, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32134122

RESUMEN

INTRODUCTION: This report provides supplemental results from the 2017 National Blood Collection and Utilization Survey on characteristics of the donor population, autologous and directed donations and transfusions, platelets, plasma and granulocyte transfusions, pediatric transfusions, severe donor-related adverse events, cost of blood units, hospitals policies and practices, and inventory, dosing, and supply. METHODS: Weighting and imputation were used to generate national estimates including number of donors, donations, donor deferrals, autologous and directed donations and transfusions, severe donor-related adverse events, platelet and plasma collections and transfusions, number of cross-match procedures, irradiation and leukoreduction, and pediatric transfusions. RESULTS: Between 2015 and 2017, successful donations decreased slightly by 2.1% with a 10.3% decrease in donations by persons aged 16-18 years and a 14.4% increase in donations by donors aged >65 years. The median price paid for blood components by hospitals decreased from $211 to $207 for leukoreduced red blood cell units, from $523 to $517 for leukoreduced apheresis platelet units, and from $54 to $51 for fresh frozen plasma units. Plasma transfusions decreased 13.6%, but group AB plasma units transfused increased 24.7%. CONCLUSION: Between 2015 and 2017, blood donations declined slightly because of decreases in donations from younger donors, but the number of donations from older donors increased. The price hospitals pay for blood has continued to decrease. Plasma transfusions have decreased, but the proportion of plasma transfusions involving group AB plasma have increased.


Asunto(s)
Bancos de Sangre/estadística & datos numéricos , Donantes de Sangre/estadística & datos numéricos , Bancos de Sangre/economía , Transfusión Sanguínea/estadística & datos numéricos , Eritrocitos , Humanos , Procedimientos Quirúrgicos Operativos/estadística & datos numéricos , Encuestas y Cuestionarios , Trasplante Homólogo/estadística & datos numéricos , Estados Unidos
15.
Transfusion ; 60 Suppl 2: S10-S16, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32134123

RESUMEN

BACKGROUND: Serious transfusion-associated adverse events are rare in the United States. To enhance blood safety, various measures have been developed. With use of data from the 2017 National Blood Collection and Utilization Survey (NBCUS), we describe the rate of transfusion-associated adverse events and the implementation of specific blood safety measures. STUDY DESIGN AND METHODS: Data from the 2017 NBCUS were used with comparison to already published estimates from 2015. Survey weighting and imputation were used to obtain national estimates of transfusion-associated adverse events, and the number of units treated with pathogen reduction technology (PRT), screened for Babesia, and leukoreduced. RESULTS: The rate of transfusion-associated adverse events requiring any diagnostic or therapeutic interventions was stable (275 reactions per 100,000 transfusions in 2015 and 282 reactions per 100,000 transfusions in 2017). In 2017 among US blood collection centers, 16 of 141 (11.3%) reported screening units for Babesia and 28 of 144 (19.4%) reported PRT implementation; 138 of 2279 (6.1%) hospitals reported transfusing PRT-treated platelets. In 2017, 134 of 2336 (5.7%) hospitals reported performing secondary bacterial testing of platelets (50,922 culture-based and 63,220 rapid immunoassay tests); in 2015, 71 of 1877 (3.8%) hospitals performed secondary testing (87,155 culture-based and 21,779 rapid immunoassay tests). Nearly all whole blood/red blood cell units and platelet units were leukoreduced. CONCLUSIONS: Besides leukoreduction, implementation of most blood safety measures reported in this study remains low. Nationally, hospitals might be shifting from culture-based secondary bacterial testing to rapid immunoassays.


Asunto(s)
Seguridad de la Sangre/estadística & datos numéricos , Reacción a la Transfusión/epidemiología , Bancos de Sangre , Eliminación de Componentes Sanguíneos/estadística & datos numéricos , Plaquetas/microbiología , Seguridad de la Sangre/métodos , Eritrocitos/metabolismo , Genotipo , Humanos , Encuestas y Cuestionarios , Reacción a la Transfusión/diagnóstico , Estados Unidos/epidemiología
16.
Transfusion ; 60 Suppl 2: S1-S9, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32086817

RESUMEN

INTRODUCTION: The National Blood Collection and Utilization Survey (NBCUS) has demonstrated declines in blood collection and transfusion in the United States since 2008, including declines of 11.6% in red blood cell (RBC) collections and 13.9% in RBC transfusions during 2013-2015. This study described the 2017 NBCUS results. METHODS: The 2017 NBCUS was distributed to all US blood collection centers, all hospitals performing at least 1000 surgeries annually, and a 40% random sample of hospitals performing 100 to 999 surgeries annually. Weighting and imputation were used to generate national estimates for units of blood and components collected, deferred, distributed, transfused, and outdated. RESULTS: Response rates for the 2017 NBCUS were 88% for blood collection centers and 86% for transfusing hospitals. Compared with 2015, the number of RBC units collected during 2017 (12,211,000; 95% confidence interval [CI], 11,680,000-12,742,000) declined by 3.0%, and transfused RBC units (10,654,000, 95% CI, 10,314,000-10,995,000) declined by 6.1%. Distributed platelet (PLT) units (2,560,000; 95% CI, 2,391,000-2,730,000 units) increased by 5.1%, and transfused PLT units (1,937,000, 95% CI, 1,794,000-2,079,000) declined by 2.3%. Distributed plasma units (3,209,000; 95% CI, 2,879,000-3,539,000) declined by 13.6%, and transfused plasma units (2,374,000; 95% CI, 2,262,000-2,487,000) declined by 12.9%. CONCLUSION: The 2017 NBCUS suggests a continued but slowing decline in demand for RBCs. The decline in blood collection and use will likely continue. Despite decreasing demand and increasing manufacturing costs of blood products, the US blood industry has met the regular and emergent needs of the country.


Asunto(s)
Donantes de Sangre/estadística & datos numéricos , Transfusión Sanguínea/estadística & datos numéricos , Bancos de Sangre/estadística & datos numéricos , Transfusión de Eritrocitos/estadística & datos numéricos , Hospitales , Humanos , Transfusión de Plaquetas/estadística & datos numéricos , Encuestas y Cuestionarios , Trasplante Homólogo , Estados Unidos
17.
J Pediatr ; 219: 188-195.e6, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32005542

RESUMEN

OBJECTIVE: To identify types of containers from which young children accessed solid dose medications (SDMs) during unsupervised medication exposures and the intended recipients of the medications to advance prevention. STUDY DESIGN: From February to September 2017, 5 US poison centers enrolled individuals calling about unsupervised solid dose medication exposures by children ≤5 years. Study participants answered contextually directed questions about exposure circumstances. RESULTS: Sixty-two percent of eligible callers participated. Among 4496 participants, 71.6% of SDM exposures involved children aged ≤2 years; 33.8% involved only prescription medications, 32.8% involved only over-the-counter (OTC) products that require child-resistant packaging, and 29.9% involved ≥1 OTC product that does not require child-resistant packaging. More than one-half of exposures (51.5%) involving prescription medications involved children accessing medications that had previously been removed from original packaging, compared with 20.8% of exposures involving OTC products (aOR, 3.39; 95% CI, 2.87-4.00). Attention deficit hyperactivity disorder medications (49.3%) and opioids (42.6%) were often not in any container when accessed; anticonvulsants (41.1%), hypoglycemic agents (33.8%), and cardiovascular/antithrombotic agents (30.8%) were often transferred to alternate containers. Grandparents' medications were involved in 30.7% of prescription medication exposures, but only 7.8% of OTC product exposures (aOR, 3.99; 95% CI, 3.26-4.87). CONCLUSIONS: Efforts to reduce pediatric SDM exposures should also address exposures in which adults, rather than children, remove medications from child-resistant packaging. Packaging/storage innovations designed to encourage adults to keep products within child-resistant packaging and specific educational messages could be targeted based on common exposure circumstances, medication classes, and medication intended recipients.


Asunto(s)
Embalaje de Medicamentos , Medicamentos sin Prescripción/envenenamiento , Medicamentos bajo Prescripción/envenenamiento , Preescolar , Estudios Transversales , Femenino , Humanos , Lactante , Masculino , Estudios Prospectivos
18.
Am J Transplant ; 19(9): 2560-2569, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-30959569

RESUMEN

Under US Public Health Service guidelines, organ donors with risk factors for human immunodeficiency virus (HIV), hepatitis B virus (HBV), or hepatitis C virus (HCV) are categorized as increased risk donors (IRD). Previous studies have suggested that IRD organs are utilized at lower rates than organs from standard risk donors (SRD), but these studies were conducted prior to universal donor nucleic acid test screening. We conducted risk-adjusted analyses to determine the effect of IRD designation on organ utilization using 2010-2017 data (21 626 heart, 101 160 kidney, 52 714 liver, and 16 219 lung recipients in the United States) from the Organ Procurement and Transplantation Network. There was no significant difference (P < .05) between risk-adjusted utilization rates for IRD vs SRD organs for adult hearts and livers and pediatric kidneys, livers, and lungs. Significantly lower utilization was found among IRD adult kidneys, lungs, and pediatric hearts. Analysis of the proportion of transplanted organs recovered from IRD by facility suggests that a subset of facilities contribute to the underutilization of adult IRD kidneys. Along with revised criteria and nomenclature to identify donors with HIV, HBV, or HCV risk factors, educational efforts to standardize informed consent discussions might improve organ utilization.


Asunto(s)
Selección de Donante/métodos , Trasplante de Órganos/efectos adversos , Trasplante de Órganos/normas , Donantes de Tejidos , Obtención de Tejidos y Órganos/normas , Adulto , Niño , Infecciones por VIH/transmisión , Trasplante de Corazón/efectos adversos , Hepatitis B/transmisión , Hepatitis C/transmisión , Humanos , Trasplante de Riñón/efectos adversos , Trasplante de Hígado/efectos adversos , Trasplante de Pulmón/efectos adversos , Guías de Práctica Clínica como Asunto , Pautas de la Práctica en Medicina , Evaluación de Procesos, Atención de Salud , Medición de Riesgo , Factores de Riesgo , Estados Unidos , United States Public Health Service
19.
Transfus Med Rev ; 33(2): 84-91, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30930009

RESUMEN

Transfusion-transmitted infections (TTIs) can be severe and result in death. Transfusion-transmitted viral pathogen transmission has been substantially reduced, whereas sepsis due to bacterial contamination of platelets and transfusion-transmitted babesiosis may occur more frequently. Quantifying the burden of TTI is important to develop targeted interventions. From January 1, 2010, to December 31, 2016, health care facilities participating in the National Healthcare Safety Network Hemovigilance Module monitored transfusion recipients for evidence of TTI and recorded the total number of units transfused. Facilities use standard criteria to report TTIs. Incidence rates of TTIs, including for bacterial contamination of platelets and transfusion-transmitted babesiosis, are presented. One hundred ninety-five facilities reported 111 TTIs and 7.9 million transfused components to the National Healthcare Safety Network Hemovigilance Module. Of these 111 reports, 54 met inclusion criteria. The most frequently reported pathogens were Babesia spp in RBCs (16/23, 70%) and Staphylococcus aureus in platelets (12/30, 40%). There were 1.95 (26 apheresis, 4 whole blood derived) TTIs per 100 000 transfused platelet units and 0.53 TTI per 100 000 transfused RBC components, compared to 0.68 TTI per 100 000 all transfused components. Bacterial contamination of platelets and transfusion-transmitted babesiosis were the most frequently reported TTIs. Interventions that reduce the burden of bacterial contamination of platelets, particularly collected by apheresis, and Babesia transmission through RBC transfusion would reduce transfusion recipient morbidity and mortality. These analyses demonstrate the value and importance of facility participation in national recipient hemovigilance using standard reporting criteria.


Asunto(s)
Babesiosis/epidemiología , Seguridad de la Sangre/normas , Transfusión Sanguínea , Reacción a la Transfusión/epidemiología , Babesia , Babesiosis/etiología , Bancos de Sangre/normas , Eliminación de Componentes Sanguíneos/efectos adversos , Transfusión de Componentes Sanguíneos/efectos adversos , Humanos , Transfusión de Plaquetas/efectos adversos , Infecciones Estafilocócicas/epidemiología , Infecciones Estafilocócicas/etiología , Staphylococcus aureus , Reacción a la Transfusión/etiología , Estados Unidos
20.
Transfusion ; 59(3): 1125-1131, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30740714

RESUMEN

BACKGROUND: Estimates of blood collection and use in the United States derived from the National Blood Collection and Utilization Survey (NBCUS) call for application of robust statistical methods in the analysis of survey data. Since 1993, annual inpatient surgical volume has been used as the main stratification variable for sampling and estimation. However, recent NBCUS results have shown a decrease in blood use in surgical settings, raising the possibility that inpatient surgical volume may no longer be the optimal stratification variable. The objective of this study is to explore factors affecting hospital blood utilization. STUDY DESIGN AND METHODS: A multivariate generalized linear regression with a negative binomial distribution was used to determine which hospital characteristics best explained allogeneic red blood cell (RBC) use, using data from the 2015 NBCUS to determine hospital blood use and the 2013 annual American Hospital Association database to identify hospital characteristics. RESULTS: Annual inpatient surgical volume explained the most variation in allogeneic RBC use among hospitals (pseudo-R2 of 70.8%). Additional variables, such as presence of an oncology service, were also statistically significant in the models but explained little additional variability in blood use. CONCLUSION: These findings suggest that annual inpatient surgical volume is an appropriate indicator for estimating blood utilization in the United States. As trends in blood utilization continue to evolve, ongoing analytic efforts to understand indicators of blood use are necessary.


Asunto(s)
Complicaciones Posoperatorias/terapia , Bases de Datos Factuales , Femenino , Hospitales/estadística & datos numéricos , Humanos , Pacientes Internos/estadística & datos numéricos , Modelos Lineales , Masculino , Análisis Multivariante , Complicaciones Posoperatorias/epidemiología , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...