Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Acta Biomater ; 53: 46-58, 2017 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-28185910

RESUMEN

Chronically implanted neural multi-electrode arrays (MEA) are an essential technology for recording electrical signals from neurons and/or modulating neural activity through stimulation. However, current MEAs, regardless of the type, elicit an inflammatory response that ultimately leads to device failure. Traditionally, rigid materials like tungsten and silicon have been employed to interface with the relatively soft neural tissue. The large stiffness mismatch is thought to exacerbate the inflammatory response. In order to minimize the disparity between the device and the brain, we fabricated novel ultrasoft electrodes consisting of elastomers and conducting polymers with mechanical properties much more similar to those of brain tissue than previous neural implants. In this study, these ultrasoft microelectrodes were inserted and released using a stainless steel shuttle with polyethyleneglycol (PEG) glue. The implanted microwires showed functionality in acute neural stimulation. When implanted for 1 or 8weeks, the novel soft implants demonstrated significantly reduced inflammatory tissue response at week 8 compared to tungsten wires of similar dimension and surface chemistry. Furthermore, a higher degree of cell body distortion was found next to the tungsten implants compared to the polymer implants. Our results support the use of these novel ultrasoft electrodes for long term neural implants. STATEMENT OF SIGNIFICANCE: One critical challenge to the translation of neural recording/stimulation electrode technology to clinically viable devices for brain computer interface (BCI) or deep brain stimulation (DBS) applications is the chronic degradation of device performance due to the inflammatory tissue reaction. While many hypothesize that soft and flexible devices elicit reduced inflammatory tissue responses, there has yet to be a rigorous comparison between soft and stiff implants. We have developed an ultra-soft microelectrode with Young's modulus lower than 1MPa, closely mimicking the brain tissue modulus. Here, we present a rigorous histological comparison of this novel ultrasoft electrode and conventional stiff electrode with the same size, shape and surface chemistry, implanted in rat brains for 1-week and 8-weeks. Significant improvement was observed for ultrasoft electrodes, including inflammatory tissue reaction, electrode-tissue integration as well as mechanical disturbance to nearby neurons. A full spectrum of new techniques were developed in this study, from insertion shuttle to in situ sectioning of the microelectrode to automated cell shape analysis, all of which should contribute new methods to the field. Finally, we showed the electrical functionality of the ultrasoft electrode, demonstrating the potential of flexible neural implant devices for future research and clinical use.


Asunto(s)
Materiales Biocompatibles , Electrodos Implantados , Microelectrodos , Neuronas/fisiología , Animales , Materiales Biocompatibles/efectos adversos , Materiales Biocompatibles/química , Barrera Hematoencefálica , Conductividad Eléctrica , Estimulación Eléctrica , Electrodos Implantados/efectos adversos , Reacción a Cuerpo Extraño/prevención & control , Inflamación/prevención & control , Masculino , Ensayo de Materiales , Microelectrodos/efectos adversos , Polímeros , Ratas , Ratas Sprague-Dawley , Elastómeros de Silicona , Núcleo Subtalámico/fisiología , Núcleo Subtalámico/cirugía , Tungsteno/efectos adversos
2.
Soft Matter ; 11(24): 4847-61, 2015 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-25993261

RESUMEN

Current designs for microelectrodes used for interfacing with the nervous system elicit a characteristic inflammatory response that leads to scar tissue encapsulation, electrical insulation of the electrode from the tissue and ultimately failure. Traditionally, relatively stiff materials like tungsten and silicon are employed which have mechanical properties several orders of magnitude different from neural tissue. This mechanical mismatch is thought to be a major cause of chronic inflammation and degeneration around the device. In an effort to minimize the disparity between neural interface devices and the brain, novel soft electrodes consisting of elastomers and intrinsically conducting polymers were fabricated. The physical, mechanical and electrochemical properties of these materials were extensively characterized to identify the formulations with the optimal combination of parameters including Young's modulus, elongation at break, ultimate tensile strength, conductivity, impedance and surface charge injection. Our final electrode has a Young's modulus of 974 kPa which is five orders of magnitude lower than tungsten and significantly lower than other polymer-based neural electrode materials. In vitro cell culture experiments demonstrated the favorable interaction between these soft materials and neurons, astrocytes and microglia, with higher neuronal attachment and a two-fold reduction in inflammatory microglia attachment on soft devices compared to stiff controls. Surface immobilization of neuronal adhesion proteins on these microwires further improved the cellular response. Finally, in vivo electrophysiology demonstrated the functionality of the elastomeric electrodes in recording single unit activity in the rodent visual cortex. The results presented provide initial evidence in support of the use of soft materials in neural interface applications.


Asunto(s)
Materiales Biocompatibles/química , Electrofisiología/instrumentación , Nanocables/química , Neuronas/fisiología , Elastómeros de Silicona/química , Animales , Materiales Biocompatibles/efectos adversos , Células Cultivadas , Módulo de Elasticidad , Conductividad Eléctrica , Electrofisiología/métodos , Microelectrodos , Nanocables/efectos adversos , Neuronas/efectos de los fármacos , Ratas , Ratas Sprague-Dawley , Elastómeros de Silicona/efectos adversos
3.
J Biomed Mater Res A ; 102(8): 2554-64, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23964001

RESUMEN

Nerve guidance conduits (NGCs) are FDA-approved devices used to bridge gaps across severed nerve cables and help direct axons sprouting from the proximal end toward the distal stump. In this article, we present the development of a novel electrically conductive, biodegradable NGC made from a polypyrrole-block-polycaprolactone (PPy-PCL) copolymer material laminated with poly(lactic-co-glycolic acid) (PLGA). The PPy-PCL has a bulk conductivity ranging 10-20 S/cm and loses 40 wt % after 7 months under physiologic conditions. Dorsal root ganglia (DRG) grown on flat PPy-PCL/PLGA material exposed to direct current electric fields (EF) of 100 mV/cm for 2 h increased axon growth by 13% (± 2%) toward either electrode of a 2-electrode setup, compared with control grown on identical substrates without EF exposure. Alternating current increased axon growth by 21% (±3%) without an observable directional preference, compared with the same control group. The results from this study demonstrate PLGA-coated PPy-PCL is a unique biodegradable material that can deliver substrate EF stimulation to improve axon growth for peripheral nerve repair.


Asunto(s)
Materiales Biocompatibles/farmacología , Caproatos/farmacología , Lactonas/farmacocinética , Neuronas/citología , Polímeros/farmacología , Polímeros/farmacocinética , Pirroles/farmacología , Animales , Axones/efectos de los fármacos , Axones/metabolismo , Materiales Biocompatibles/síntesis química , Materiales Biocompatibles/química , Caproatos/síntesis química , Caproatos/química , Adhesión Celular/efectos de los fármacos , Recuento de Células , Muerte Celular/efectos de los fármacos , Proliferación Celular/efectos de los fármacos , Supervivencia Celular/efectos de los fármacos , Conductividad Eléctrica , Estimulación Eléctrica , Ganglios Espinales/citología , Ganglios Espinales/efectos de los fármacos , Concentración de Iones de Hidrógeno , Lactonas/síntesis química , Lactonas/química , Peso Molecular , Neuronas/efectos de los fármacos , Neuronas/metabolismo , Células PC12 , Polímeros/síntesis química , Polímeros/química , Pirroles/síntesis química , Pirroles/química , Ratas , Ratas Sprague-Dawley , Espectroscopía Infrarroja por Transformada de Fourier
4.
J Biomater Sci Polym Ed ; 21(10): 1265-82, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20534184

RESUMEN

Synthetic polymers such as polypyrrole (PPy) are gaining significance in neural studies because of their conductive properties. We evaluated two novel biodegradable block co-polymers of PPy with poly(epsilon-caprolactone) (PCL) and poly(ethyl cyanoacrylate) (PECA) for nerve regeneration applications. PPy-PCL and PPy-PECA co-polymers can be processed from solvent-based colloidal dispersions and have essentially the same or greater conductivity (32 S/cm for PPy-PCL, 19 S/cm for PPy-PECA) compared to the PPy homo-polymer (22 S/cm). The PPy portions of the co-polymers permit electrical stimulation whereas the PCL or PECA blocks enable degradation by hydrolysis. For in vitro tests, films were prepared on polycarbonate sheets by air brushing layers of dispersions and pressing the films. We characterized the films for hydrolytic degradation, electrical conductivity, cell proliferation and neurite extension. The co-polymers were sufficient to carry out electrical stimulation of cells without the requirement of a metallic conductor underneath the co-polymer film. In vitro electrical stimulation of PPy-PCL significantly increased the number of PC12 cells bearing neurites compared to unstimulated PPy-PCL. For in vivo experiments, the PPy co-polymers were coated onto the inner walls of nerve guidance channels (NGCs) made of the commercially available non-conducting biodegradable polymer poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHB-HV). The NGCs were implanted in a 10 mm defect made in the sciatic nerve of rats, and harvested after 8 weeks. Histological staining showed axonal growth. The studies indicated that these new conducting degradable biomaterials have good biocompatibility and support proliferation and growth of PC12 cells in vitro (with and without electrical stimulation) and neurons in vivo (without electrical stimulation).


Asunto(s)
Proliferación Celular/efectos de los fármacos , Estimulación Eléctrica , Neuritas/efectos de los fármacos , Polímeros/química , Polímeros/farmacología , Pirroles/química , Animales , Células PC12 , Polímeros/síntesis química , Prohibitinas , Ratas
5.
J Am Chem Soc ; 124(37): 11215-22, 2002 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-12224970

RESUMEN

A number of cobalt complexes of substituted polypyridine ligands were synthesized and investigated as possible alternatives to the volatile and corrosive iodide/triiodide redox couple commonly used as an electron-transfer mediator in dye-sensitized solar cells (DSSCs). The extinction coefficients in the visible spectrum are on the order of 10(2) M(-1) cm(-1) for the majority of these complexes, diminishing competition with the light-harvesting dye. Cyclic voltammetric studies revealed a dramatic surface dependence of the heterogeneous electron-transfer rate, which is surprisingly different for gold, carbon, and platinum electrodes. DSSCs were assembled using a mediator that consisted of a mixture of Co(II) and Co(III) complexes in a 10:1 ratio. DSSCs containing these mediators were used to characterize incident photon-to-current conversion efficiency and photoelectrochemical responses. The best performing of these mediators were identified and subjected to further study. As suggested by electrochemical results, gold and carbon are superior cathode materials to platinum, and no evidence of corrosion on any cathode material was observed. Addition of lithium salts to the mediator solution resulted in a dramatic improvement in cell performance. The observed Li(+) effect is explained in terms of the recombination of injected electrons in the photoanode with the oxidized mediator. The best mediator, based on tris(4,4'-di-tert-butyl-2,2'-dipyridyl)cobalt(II/III) perchlorate, resulted in DSSCs exhibiting efficiencies within 80% of that of a comparable iodide/triiodide-mediated DSSC. Due to the commercial availability of the ligand and the simplicity with which the complex can be made, this new mediator represents a nonvolatile, noncorrosive, and practical alternative as an efficient electron-transfer mediator in DSSCs.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...