Insights Imaging ; 15(1): 96, 2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-38536530

RESUMEN

In the mid-1990s, the identification of BRCA1/2 genes for breast cancer susceptibility led to testing breast MRI accuracy in screening women at increased risk. From 2000 onwards, ten intraindividual comparative studies showed the marked superiority of MRI: the sensitivity ranged 25-58% for mammography, 33-52% for ultrasound, 48-67% for mammography plus ultrasound, and 71-100% for MRI; specificity 93-100%, 91-98%, 89-98%, and 81-98%, respectively. Based on the available evidence, in 2006-2007, the UK National Institute for Clinical Excellence and the American Cancer Society recommended MRI screening of high-risk women, followed by other international guidelines. Despite evidence-based medicine ideally requiring randomised controlled trials (RCTs) for policy changes regarding screening procedures, breast MRI for high-risk screening was adopted in many countries worldwide. In 2019, the results of the "DENSE" RCT were published in favour of breast MRI screening of women with extremely dense breasts compared to mammography alone, showing a reduction of more than 80% of the interval cancer rate in women who attended MRI screening. Even though international recommendations in favour of this practice were issued, substantial obstacles still prevent health systems from adopting breast MRI for screening women with extremely dense breasts. A paradox is evident: we adopted a screening procedure without evidence from RCTs, and now that we have this level-1 evidence for the same procedure, we fail to do so. This critical review tries to explain the differences between the two cases, as examples of the complex pathways of translating radiological research into everyday practice.Critical relevance statement The high-level evidence in favour of breast MRI screening of women with extremely dense breasts is failing to persuade policy makers to translate this into clinical practice.Key points• Breast MRI screening of high-risk women was adopted on basis of the evidence provided by test accuracy comparative studies showing an MRI performance greatly superior to that of mammography.• Breast MRI screening of women with extremely dense breasts has not been adopted although the evidence of a large reduction in interval cancer rate from a RCT.• We illustrate the differences between the two cases, as an example of the complex ways of translation of radiological research in clinical practice according to the EBM theory.

2.
Eur Radiol Exp ; 8(1): 35, 2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38418763

RESUMEN

OBJECTIVES: Energy consumption and carbon emissions from medical equipment like CT/MRI scanners and workstations contribute to the environmental impact of healthcare facilities. The aim of this systematic review was to identify all strategies to reduce energy use and carbon emissions in radiology. METHODS: In June 2023, a systematic review (Medline/Embase/Web of Science) was performed to search original articles on environmental sustainability in radiology. The extracted data include environmental sustainability topics (e.g., energy consumption, carbon footprint) and radiological devices involved. Sustainable actions and environmental impact in radiology settings were analyzed. Study quality was assessed using the QualSyst tool. RESULTS: From 918 retrieved articles, 16 met the inclusion criteria. Among them, main topics were energy consumption (10/16, 62.5%), life-cycle assessment (4/16, 25.0%), and carbon footprint (2/16, 12.5%). Eleven studies reported that 40-91% of the energy consumed by radiological devices can be defined as "nonproductive" (devices "on" but not working). Turning-off devices during idle periods 9/16 (56.2%) and implementing workflow informatic tools (2/16, 12.5%) were the sustainable actions identified. Energy-saving strategies were reported in 8/16 articles (50%), estimating annual savings of thousand kilowatt-hours (14,180-171,000 kWh). Cost-savings were identified in 7/16 (43.7%) articles, ranging from US $9,225 to 14,328 per device. Study quality was over or equal the 80% of high-quality level in 14/16 (87.5%) articles. CONCLUSION: Energy consumption and environmental sustainability in radiology received attention in literature. Sustainable actions include turning-off radiological devices during idle periods, favoring the most energy-efficient imaging devices, and educating radiological staff on energy-saving practices, without compromising service quality. RELEVANCE STATEMENT: A non-negligible number of articles - mainly coming from North America and Europe - highlighted the need for energy-saving strategies, attention to equipment life-cycle assessment, and carbon footprint reduction in radiology, with a potential for cost-saving outcome. KEY POINTS: • Energy consumption and environmental sustainability in radiology received attention in the literature (16 articles published from 2010 to 2023). • A substantial portion (40-91%) of the energy consumed by radiological devices was classified as "non-productive" (devices "on" but not working). • Sustainable action such as shutting down devices during idle periods was identified, with potential annual energy savings ranging from 14,180 to 171,000 kWh.


Asunto(s)
Huella de Carbono , Radiología , Humanos , Tomógrafos Computarizados por Rayos X , Imagen por Resonancia Magnética , Europa (Continente)
5.
Insights Imaging ; 15(1): 13, 2024 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-38228934

RESUMEN

At the European Society of Radiology (ESR), we strive to provide evidence for radiological practices that improve patient outcomes and have a societal impact. Successful translation of radiological research into clinical practice requires multiple factors including tailored methodology, a multidisciplinary approach aiming beyond technical validation, and a focus on unmet clinical needs. Low levels of evidence are a threat to radiology, resulting in low visibility and credibility. Here, we provide the background and rationale for the thematic series Translating radiological research into practice-from discovery to clinical impact, inviting authors to describe their processes of achieving clinically impactful radiological research. We describe the challenges unique to radiological research. Additionally, a survey was sent to non-radiological clinical societies. The majority of respondents (6/11) were in the field of gastrointestinal/abdominal medicine. The implementation of CT/MRI techniques for disease characterisation, detection and staging of cancer, and treatment planning and radiological interventions were mentioned as the most important radiological developments in the past years. The perception was that patients are substantially unaware of the impact of these developments. Unmet clinical needs were mostly early diagnosis and staging of cancer, microstructural/functional assessment of tissues and organs, and implant assessment. All but one respondent considered radiology important for research in their discipline, but five indicated that radiology is currently not involved in their research. Radiology research holds the potential for being transformative to medical practice. It is our responsibility to take the lead in studies including radiology and strive towards the highest levels of evidence.Critical relevance statement For radiological research to make a clinical and societal impact, radiologists should take the lead in radiological studies, go beyond the assessment of technical feasibility and diagnostic accuracy, and-in a multidisciplinary approach-address clinical unmet needs.Key points• Multiple factors are essential for radiological research to make a clinical and societal impact.• Radiological research needs to go beyond diagnostic accuracy and address unmet clinical needs.• Radiologists should take the lead in radiological studies with a multidisciplinary approach.

6.
Insights Imaging ; 15(1): 8, 2024 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-38228979

RESUMEN

PURPOSE: To propose a new quality scoring tool, METhodological RadiomICs Score (METRICS), to assess and improve research quality of radiomics studies. METHODS: We conducted an online modified Delphi study with a group of international experts. It was performed in three consecutive stages: Stage#1, item preparation; Stage#2, panel discussion among EuSoMII Auditing Group members to identify the items to be voted; and Stage#3, four rounds of the modified Delphi exercise by panelists to determine the items eligible for the METRICS and their weights. The consensus threshold was 75%. Based on the median ranks derived from expert panel opinion and their rank-sum based conversion to importance scores, the category and item weights were calculated. RESULT: In total, 59 panelists from 19 countries participated in selection and ranking of the items and categories. Final METRICS tool included 30 items within 9 categories. According to their weights, the categories were in descending order of importance: study design, imaging data, image processing and feature extraction, metrics and comparison, testing, feature processing, preparation for modeling, segmentation, and open science. A web application and a repository were developed to streamline the calculation of the METRICS score and to collect feedback from the radiomics community. CONCLUSION: In this work, we developed a scoring tool for assessing the methodological quality of the radiomics research, with a large international panel and a modified Delphi protocol. With its conditional format to cover methodological variations, it provides a well-constructed framework for the key methodological concepts to assess the quality of radiomic research papers. CRITICAL RELEVANCE STATEMENT: A quality assessment tool, METhodological RadiomICs Score (METRICS), is made available by a large group of international domain experts, with transparent methodology, aiming at evaluating and improving research quality in radiomics and machine learning. KEY POINTS: • A methodological scoring tool, METRICS, was developed for assessing the quality of radiomics research, with a large international expert panel and a modified Delphi protocol. • The proposed scoring tool presents expert opinion-based importance weights of categories and items with a transparent methodology for the first time. • METRICS accounts for varying use cases, from handcrafted radiomics to entirely deep learning-based pipelines. • A web application has been developed to help with the calculation of the METRICS score ( https://metricsscore.github.io/metrics/METRICS.html ) and a repository created to collect feedback from the radiomics community ( https://github.com/metricsscore/metrics ).

8.
Eur J Cancer ; 198: 113500, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38199146

RESUMEN

INTRODUCTION: Quality care in breast cancer is higher if patients are treated in a Breast Center with a dedicated and specialized multidisciplinary team. Quality control is an essential activity to ensure quality care, which has to be based on the monitoring of specific quality indicators. Eusoma has proceeded with the up-dating of the 2017 Quality indicators for non-metastatic breast cancer based on the new diagnostic, locoregional and systemic treatment modalities. METHODS: To proceed with the updating, EUSOMA setup a multidisciplinary working group of BC experts and patients' representatives. It is a comprehensive set of QIs for early breast cancer care, which are classified as mandatory, recommended, or observational. For the first time patient reported outcomes (PROMs) have been included. As used in the 2017 EUSOMA QIs, evidence levels were based on the short version of the US Agency for Healthcare Research and Quality. RESULTS: This is a set of quality indicators representative for the different steps of the patient pathway in non-metastatic setting, which allow Breast Centres to monitor their performance with referring standards, i.e minimum standard and target. CONCLUSIONS: Monitoring these Quality Indicators, within the Eusoma datacentre will allow to have a state of the art picture at European Breast Centres level and the development of challenging research projects.


Asunto(s)
Neoplasias de la Mama , Indicadores de Calidad de la Atención de Salud , Humanos , Femenino , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/terapia , Calidad de la Atención de Salud
9.
Eur J Cancer ; 199: 113553, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38262307

RESUMEN

AIM: The analyses here reported aim to compare the screening performance of digital tomosynthesis (DBT) versus mammography (DM). METHODS: MAITA is a consortium of four Italian trials, REtomo, Proteus, Impeto, and MAITA trial. The trials adopted a two-arm randomised design comparing DBT plus DM (REtomo and Proteus) or synthetic-2D (Impeto and MAITA trial) versus DM; multiple vendors were included. Women aged 45 to 69 years were individually randomised to one round of DBT or DM. FINDINGS: From March 2014 to February 2022, 50,856 and 63,295 women were randomised to the DBT and DM arm, respectively. In the DBT arm, 6656 women were screened with DBT plus synthetic-2D. Recall was higher in the DBT arm (5·84% versus 4·96%), with differences between centres. With DBT, 0·8/1000 (95% CI 0·3 to 1·3) more women received surgical treatment for a benign lesion. The detection rate was 51% higher with DBT, ie. 2·6/1000 (95% CI 1·7 to 3·6) more cancers detected, with a similar relative increase for invasive cancers and ductal carcinoma in situ. The results were similar below and over the age of 50, at first and subsequent rounds, and with DBT plus DM and DBT plus synthetic-2D. No learning curve was appreciable. Detection of cancers >= 20 mm, with 2 or more positive lymph nodes, grade III, HER2-positive, or triple-negative was similar in the two arms. INTERPRETATION: Results from MAITA confirm that DBT is superior to DM for the detection of cancers, with a possible increase in recall rate. DBT performance in screening should be assessed locally while waiting for long-term follow-up results on the impact of advanced cancer incidence.


Asunto(s)
Neoplasias de la Mama , Carcinoma Intraductal no Infiltrante , Femenino , Humanos , Mama/diagnóstico por imagen , Mama/patología , Neoplasias de la Mama/diagnóstico , Detección Precoz del Cáncer/métodos , Incidencia , Mamografía/métodos , Tamizaje Masivo/métodos , Persona de Mediana Edad , Anciano , Ensayos Clínicos Controlados Aleatorios como Asunto
10.
Eur J Surg Oncol ; 50(1): 107292, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38061151

RESUMEN

INTRODUCTION: Breast lesions of uncertain malignant potential (B3) include atypical ductal and lobular hyperplasias, lobular carcinoma in situ, flat epithelial atypia, papillary lesions, radial scars and fibroepithelial lesions as well as other rare miscellaneous lesions. They are challenging to categorise histologically, requiring specialist training and multidisciplinary input. They may coexist with in situ or invasive breast cancer (BC) and increase the risk of subsequent BC development. Management should focus on adequate classification and management whilst avoiding overtreatment. The aim of these guidelines is to provide updated information regarding the diagnosis and management of B3 lesions, according to updated literature review evidence. METHODS: These guidelines provide practical recommendations which can be applied in clinical practice which include recommendation grade and level of evidence. All sections were written according to an updated literature review and discussed at a consensus meeting. Critical appraisal by the expert writing committee adhered to the 23 items in the international Appraisal of Guidelines, Research and Evaluation (AGREE) tool. RESULTS: Recommendations for further management after core-needle biopsy (CNB) or vacuum-assisted biopsy (VAB) diagnosis of a B3 lesion reported in this guideline, vary depending on the presence of atypia, size of lesion, sampling size, and patient preferences. After CNB or VAB, the option of vacuum-assisted excision or surgical excision should be evaluated by a multidisciplinary team and shared decision-making with the patient is crucial for personalizing further treatment. De-escalation of surgical intervention for B3 breast lesions is ongoing, and the inclusion of vacuum-assisted excision (VAE) will decrease the need for surgical intervention in further approaches. Communication with patients may be different according to histological diagnosis, presence or absence of atypia, or risk of upgrade due to discordant imaging. Written information resources to help patients understand these issues alongside with verbal communication is recommended. Lifestyle interventions have a significant impact on BC incidence so lifestyle interventions need to be suggested to women at increased BC risk as a result of a diagnosis of a B3 lesion. CONCLUSIONS: These guidelines provide a state-of-the-art overview of the diagnosis, management and prognosis of B3 lesions in modern multidisciplinary breast practice.


Asunto(s)
Neoplasias de la Mama , Mama , Femenino , Humanos , Biopsia con Aguja Gruesa , Mama/patología , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/terapia , Mamografía/métodos
12.
Eur J Cancer ; 196: 113438, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37995597

RESUMEN

INTRODUCTION: The present study was designed to describe tumour features and treatments for patients with breast cancer. It also aimed at assessing the risk of distant metastases in relation to biological profiles, disease stages and treatment. METHODS: Data were analysed from 81,882 patients in the EUSOMA database (disease stages at diagnosis 0-IV; median age 61 years; range 20-100 years). All patients were treated between January 2016 and December 2021 in 53 Breast Centres within the EUSOMA certification process in 13 European countries. Cases were classified as HR+ /HER2-, HR+ /HER2 + , HR-/HER2 + or HR-/HER2- and data were analysed accordingly. RESULTS: Univariable and multivariable analyses for distant metastases were conducted on a subset of 38,119 cases with information on whether or not they had developed them. Potential determinants included sub-group type, Ki67 value, disease stage, adjuvant systemic therapies and post-operative radiation therapy. In multivariable analysis, the HR-/HER2 + and HR-/HER2- sub-groups were associated with a higher risk of distant metastases than HR+ /HER2-. Ki67 > 20 % and advanced stage disease also carried a high risk. Radiation therapy emerged as a protective factor against distant metastases. CONCLUSIONS: Present results show a large patient database offers an information stream that can be applied to reduce uncertainties in clinical practice. Database parameters need to be updated dynamically for outcome monitoring. Molecular prognostic factors, gene-expression signatures, tumour-infiltrating lymphocytes and circulating tumoral DNA should be added.


Asunto(s)
Neoplasias de la Mama , Humanos , Persona de Mediana Edad , Femenino , Neoplasias de la Mama/tratamiento farmacológico , Antígeno Ki-67 , Receptor ErbB-2 , Terapia Combinada , Resultado del Tratamiento , Pronóstico
13.
Eur Radiol ; 34(4): 2699-2710, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37823922

RESUMEN

OBJECTIVES: MRI-derived extracellular volume (ECV) allows characterization of myocardial changes before the onset of overt pathology, which may be caused by cancer therapy cardiotoxicity. Our purpose was to review studies exploring the role of MRI-derived ECV as an early cardiotoxicity biomarker to guide timely intervention. MATERIALS AND METHODS: In April 2022, we performed a systematic search on EMBASE and PubMed for articles on MRI-derived ECV as a biomarker of cancer therapy cardiotoxicity. Two blinded researchers screened the retrieved articles, including those reporting ECV values at least 3 months from cardiotoxic treatment. Data extraction was performed for each article, including clinical and technical data, and ECV values. Pooled ECV was calculated using the random effects model and compared among different treatment regimens and among those who did or did not experience overt cardiac dysfunction. Meta-regression analyses were conducted to appraise which clinical or technical variables yielded a significant impact on ECV. RESULTS: Overall, 19 studies were included. Study populations ranged from 9 to 236 patients, for a total of 1123 individuals, with an average age ranging from 12.5 to 74 years. Most studies included patients with breast or esophageal cancer, treated with anthracyclines and chest radiotherapy. Pooled ECV was 28.44% (95% confidence interval, CI, 26.85-30.03%) among subjects who had undergone cardiotoxic cancer therapy, versus 25.23% (95%CI 23.31-27.14%) among those who had not (p = .003). CONCLUSION: A higher ECV in patients who underwent cardiotoxic treatment could imply subclinical changes in the myocardium, present even before overt cardiac pathology is detectable. CLINICAL RELEVANCE STATEMENT: The ability to detect subclinical changes in the myocardium displayed by ECV suggests its use as an early biomarker of cancer therapy-related cardiotoxicity. KEY POINTS: • Cardiotoxicity is a common adverse effect of cancer therapy; therefore, its prompt detection could improve patient outcomes. • Pooled MRI-derived myocardial extracellular volume was higher in patients who underwent cardiotoxic cancer therapy than in those who did not (28.44% versus 25.23%, p = .003). • MRI-derived myocardial extracellular volume represents a potential early biomarker of cancer therapy cardiotoxicity.


Asunto(s)
Cardiotoxicidad , Neoplasias , Humanos , Niño , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Cardiotoxicidad/diagnóstico por imagen , Cardiotoxicidad/etiología , Cardiotoxicidad/patología , Imagen por Resonancia Magnética , Miocardio/patología , Biomarcadores , Neoplasias/diagnóstico por imagen , Neoplasias/tratamiento farmacológico , Neoplasias/patología , Imagen por Resonancia Cinemagnética , Valor Predictivo de las Pruebas
14.
Eur Radiol ; 2023 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-37999727

RESUMEN

OBJECTIVES: To investigate the influence of preoperative breast MRI on mastectomy and reoperation rates in patients with pure ductal carcinoma in situ (DCIS). METHODS: The MIPA observational study database (7245 patients) was searched for patients aged 18-80 years with pure unilateral DCIS diagnosed at core needle or vacuum-assisted biopsy (CNB/VAB) and planned for primary surgery. Patients who underwent preoperative MRI (MRI group) were matched (1:1) to those who did not receive MRI (noMRI group) according to 8 confounding covariates that drive referral to MRI (age; hormonal status; familial risk; posterior-to-nipple diameter; BI-RADS category; lesion diameter; lesion presentation; surgical planning at conventional imaging). Surgical outcomes were compared between the matched groups with nonparametric statistics after calculating odds ratios (ORs). RESULTS: Of 1005 women with pure unilateral DCIS at CNB/VAB (507 MRI group, 498 noMRI group), 309 remained in each group after matching. First-line mastectomy rate in the MRI group was 20.1% (62/309 patients, OR 2.03) compared to 11.0% in the noMRI group (34/309 patients, p = 0.003). The reoperation rate was 10.0% in the MRI group (31/309, OR for reoperation 0.40) and 22.0% in the noMRI group (68/309, p < 0.001), with a 2.53 OR of avoiding reoperation in the MRI group. The overall mastectomy rate was 23.3% in the MRI group (72/309, OR 1.40) and 17.8% in the noMRI group (55/309, p = 0.111). CONCLUSIONS: Compared to those going directly to surgery, patients with pure DCIS at CNB/VAB who underwent preoperative MRI had a higher OR for first-line mastectomy but a substantially lower OR for reoperation. CLINICAL RELEVANCE STATEMENT: When confounding factors behind MRI referral are accounted for in the comparison of patients with CNB/VAB-diagnosed pure unilateral DCIS, preoperative MRI yields a reduction of reoperations that is more than twice as high as the increase in overall mastectomies. KEY POINTS: • Confounding factors cause imbalance when investigating the influence of preoperative MRI on surgical outcomes of pure DCIS. • When patient matching is applied to women with pure unilateral DCIS, reoperation rates are significantly reduced in women who underwent preoperative MRI. • The reduction of reoperations brought about by preoperative MRI is more than double the increase in overall mastectomies.

15.
Insights Imaging ; 14(1): 126, 2023 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-37466753

RESUMEN

Axillary lymphadenopathy is a common side effect of COVID-19 vaccination, leading to increased imaging-detected asymptomatic and symptomatic unilateral axillary lymphadenopathy. This has threatened to negatively impact the workflow of breast imaging services, leading to the release of ten recommendations by the European Society of Breast Imaging (EUSOBI) in August 2021. Considering the rapidly changing scenario and data scarcity, these initial recommendations kept a highly conservative approach. As of 2023, according to newly acquired evidence, EUSOBI proposes the following updates, in order to reduce unnecessary examinations and avoid delaying necessary examinations. First, recommendation n. 3 has been revised to state that breast examinations should not be delayed or rescheduled because of COVID-19 vaccination, as evidence from the first pandemic waves highlights how delayed or missed screening tests have a negative effect on breast cancer morbidity and mortality, and that there is a near-zero risk of subsequent malignant findings in asymptomatic patients who have unilateral lymphadenopathy and no suspicious breast findings. Second, recommendation n. 7 has been revised to simplify follow-up strategies: in patients without breast cancer history and no imaging findings suspicious for cancer, symptomatic and asymptomatic imaging-detected unilateral lymphadenopathy on the same side of recent COVID-19 vaccination (within 12 weeks) should be classified as a benign finding (BI-RADS 2) and no further work-up should be pursued. All other recommendations issued by EUSOBI in 2021 remain valid.

16.
Radiol Med ; 128(7): 888-889, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37306935
17.
Eur Radiol ; 33(10): 6746-6755, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37160426

RESUMEN

OBJECTIVE: Breast arterial calcifications (BAC) are a sex-specific cardiovascular disease biomarker that might improve cardiovascular risk stratification in women. We implemented a deep convolutional neural network for automatic BAC detection and quantification. METHODS: In this retrospective study, four readers labelled four-view mammograms as BAC positive (BAC+) or BAC negative (BAC-) at image level. Starting from a pretrained VGG16 model, we trained a convolutional neural network to discriminate BAC+ and BAC- mammograms. Accuracy, F1 score, and area under the receiver operating characteristic curve (AUC-ROC) were used to assess the diagnostic performance. Predictions of calcified areas were generated using the generalized gradient-weighted class activation mapping (Grad-CAM++) method, and their correlation with manual measurement of BAC length in a subset of cases was assessed using Spearman ρ. RESULTS: A total 1493 women (198 BAC+) with a median age of 59 years (interquartile range 52-68) were included and partitioned in a training set of 410 cases (1640 views, 398 BAC+), validation set of 222 cases (888 views, 89 BAC+), and test set of 229 cases (916 views, 94 BAC+). The accuracy, F1 score, and AUC-ROC were 0.94, 0.86, and 0.98 in the training set; 0.96, 0.74, and 0.96 in the validation set; and 0.97, 0.80, and 0.95 in the test set, respectively. In 112 analyzed views, the Grad-CAM++ predictions displayed a strong correlation with BAC measured length (ρ = 0.88, p < 0.001). CONCLUSION: Our model showed promising performances in BAC detection and in quantification of BAC burden, showing a strong correlation with manual measurements. CLINICAL RELEVANCE STATEMENT: Integrating our model to clinical practice could improve BAC reporting without increasing clinical workload, facilitating large-scale studies on the impact of BAC as a biomarker of cardiovascular risk, raising awareness on women's cardiovascular health, and leveraging mammographic screening. KEY POINTS: • We implemented a deep convolutional neural network (CNN) for BAC detection and quantification. • Our CNN had an area under the receiving operator curve of 0.95 for BAC detection in the test set composed of 916 views, 94 of which were BAC+ . • Furthermore, our CNN showed a strong correlation with manual BAC measurements (ρ = 0.88) in a set of 112 views.


Asunto(s)
Enfermedades de la Mama , Enfermedades Cardiovasculares , Aprendizaje Profundo , Femenino , Humanos , Persona de Mediana Edad , Estudios Retrospectivos , Mamografía/métodos , Enfermedades de la Mama/diagnóstico por imagen
19.
Eur Radiol ; 33(9): 6213-6225, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37138190

RESUMEN

OBJECTIVES: To report mastectomy and reoperation rates in women who had breast MRI for screening (S-MRI subgroup) or diagnostic (D-MRI subgroup) purposes, using multivariable analysis for investigating the role of MRI referral/nonreferral and other covariates in driving surgical outcomes. METHODS: The MIPA observational study enrolled women aged 18-80 years with newly diagnosed breast cancer destined to have surgery as the primary treatment, in 27 centres worldwide. Mastectomy and reoperation rates were compared using non-parametric tests and multivariable analysis. RESULTS: A total of 5828 patients entered analysis, 2763 (47.4%) did not undergo MRI (noMRI subgroup) and 3065 underwent MRI (52.6%); of the latter, 2441/3065 (79.7%) underwent MRI with preoperative intent (P-MRI subgroup), 510/3065 (16.6%) D-MRI, and 114/3065 S-MRI (3.7%). The reoperation rate was 10.5% for S-MRI, 8.2% for D-MRI, and 8.5% for P-MRI, while it was 11.7% for noMRI (p ≤ 0.023 for comparisons with D-MRI and P-MRI). The overall mastectomy rate (first-line mastectomy plus conversions from conserving surgery to mastectomy) was 39.5% for S-MRI, 36.2% for P-MRI, 24.1% for D-MRI, and 18.0% for noMRI. At multivariable analysis, using noMRI as reference, the odds ratios for overall mastectomy were 2.4 (p < 0.001) for S-MRI, 1.0 (p = 0.957) for D-MRI, and 1.9 (p < 0.001) for P-MRI. CONCLUSIONS: Patients from the D-MRI subgroup had the lowest overall mastectomy rate (24.1%) among MRI subgroups and the lowest reoperation rate (8.2%) together with P-MRI (8.5%). This analysis offers an insight into how the initial indication for MRI affects the subsequent surgical treatment of breast cancer. KEY POINTS: • Of 3065 breast MRI examinations, 79.7% were performed with preoperative intent (P-MRI), 16.6% were diagnostic (D-MRI), and 3.7% were screening (S-MRI) examinations. • The D-MRI subgroup had the lowest mastectomy rate (24.1%) among MRI subgroups and the lowest reoperation rate (8.2%) together with P-MRI (8.5%). • The S-MRI subgroup had the highest mastectomy rate (39.5%) which aligns with higher-than-average risk in this subgroup, with a reoperation rate (10.5%) not significantly different to that of all other subgroups.


Asunto(s)
Neoplasias de la Mama , Femenino , Humanos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Mastectomía , Mastectomía Segmentaria , Mama , Imagen por Resonancia Magnética , Cuidados Preoperatorios
20.
Eur Radiol Exp ; 7(1): 27, 2023 05 04.
Artículo en Inglés | MEDLINE | ID: mdl-37142839

RESUMEN

The potential enviromental impact of iodinated (ICAs) and gadolinium-based contrast agents (GBCAs) have recently come under scrutiny, considering the current nonselective wastewater treatment. However, their rapid excretion after intravenous administration could allow their potential recovery by targeting hospital sewage. The GREENWATER study aims to appraise the effective quantities of ICAs and GBCAs retrievable from patients' urine collected after computed tomography (CT) and magnetic resonance imaging (MRI) exams, selecting ICA/GBCA per-patient urinary excretion and patients' acceptance rate as study endpoints. Within a prospective, observational, single-centre, 1-year framework, we will enrol outpatients aged ≥ 18 years, scheduled to perform contrast-enhanced CT or MRI, willing to collect post-examination urine in dedicated canisters by prolonging their hospital stay to 1 h after injection. Collected urine will be processed and partially stored in the institutional biobank. Patient-based analysis will be performed for the first 100 CT and 100 MRI patients, and then, all analyses will be conducted on the pooled urinary sample. Quantification of urinary iodine and gadolinium will be performed with spectroscopy after oxidative digestion. The evaluation of the acceptance rate will assess the "environmental awareness" of patients and will aid to model how procedures to reduce ICA/GBCA enviromental impact could be adapted in different settings. Key points • Enviromental impact of iodinated and gadolinium-based contrast agents represents a growing point of attention.• Current wastewater treatment is unable to retrieve and recycle contrast agents.• Prolonging hospital stay may allow contrast agents retrieval from patients' urine.• The GREENWATER study will assess the effectively retrievable contrast agents' quantities.• The enrolment acceptance rate will allow to evaluate patients' "green sensitivity".


Asunto(s)
Medios de Contraste , Aguas Residuales , Humanos , Gadolinio/orina , Hospitales , Estudios Prospectivos , Sustancias Reductoras , Estudios Observacionales como Asunto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...