Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Eur J Appl Physiol ; 92(6): 702-5, 2004 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-15150662

RESUMEN

When exposed to cold, the hands need to be protected against heat loss not only in order to reduce thermal discomfort, but also to keep their efficiency. Although gloves are usually the most common protection, their thermal insulation is generally unknown. The aim of this study was to measure the heat losses from a gloved hand with a special interest in local variations. Using a calorimetric hand placed in a cold box, several types of gloves were tested. The results indicated that depending on the glove and on the area covered the heat loss reduction may vary from almost 60% to 90%. When the least efficient pair of gloves was excluded, heat exchange coefficients varied from 1.8 to 4.8 W/m2 per degrees C for the palm and from 4.2 to 6.2 W/m2 per degrees C for the back of the hand. The three medium fingers seemed to be equally treated, with a heat exchange coefficient variation of 6.3-9.0 W/m2 per degrees C. The thumb and the little finger, which require better insulation, exhibited higher local heat transfer coefficients of 8.3-12.7 W/m2 per degrees C. Some practical aspects are evoked.


Asunto(s)
Frío , Guantes Protectores , Mano , Modelos Anatómicos , Calorimetría , Convección , Humanos , Maniquíes
2.
Environ Health Prev Med ; 8(5): 178-83, 2003 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21432096

RESUMEN

OBJECTIVES: This study was performed to determine the effects of decreasing ambient temperature on peripheral blood flow and body temperature of males and females in a thermal neutral zone for references to the thermal standard of office workers. METHODS: Peripheral blood flows of the hand and feet, and body temperatures and so on of male and female subjects were measured in a climatic chamber. Air temperature was maintained at 28.5°C at the beginning. After this, air temperature was decreased linearly to 21.0°C over a period of 60 minutes. Finally, air temperature was maintained at 21.0°C. RESULTS: Blood flows and skin temperatures of male and female subjects became similar or showed no significant difference at beginning and the end of the experiment. Skin blood flow of the hand and skin temperatures of the hand and fingers decreased, and these values in females were lower than in males, when air temperature was decreased linearly in a thermal neutral zone. However, there were no remarkable differences between males and females in sublingual and mean skin temperatures during the experiment. CONCLUSION: Minimum air temperature at the thermal standard for offices in Japan is 17°C, which may be too low to be comfortable or neutral. Even in a neutral thermal condition, it is better that office workers are provided some protection such as a blanket or clothing, to protect peripheral body parts from cooling in winter, as there are individual differences in physiological thermal reactions.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA