Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Int J Radiat Oncol Biol Phys ; 106(3): 571-578, 2020 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-31759075

RESUMEN

PURPOSE: Our purpose was to report the feasibility and safety of diffusing alpha-emitter radiation therapy (DaRT), which entails the interstitial implantation of a novel alpha-emitting brachytherapy source, for the treatment of locally advanced and recurrent squamous cancers of the skin and head and neck. METHODS AND MATERIALS: This prospective first-in-human, multicenter clinical study evaluated 31 lesions in 28 patients. The primary objective was to determine the feasibility and safety of this approach, and the secondary objectives were to evaluate the initial tumor response and local progression-free survival. Eligibility criteria included all patients with biopsy-proven squamous cancers of the skin and head and neck with either primary tumors or recurrent/previously treated disease by either surgery or prior external beam radiation therapy; 13 of 31 lesions (42%) had received prior radiation therapy. Toxicity was evaluated according to the Common Terminology Criteria for Adverse Events version 4.03. Tumor response was assessed at 30 to 45 days at a follow-up visit using the Response Evaluation Criteria in Solid Tumors, version 1.1. Median follow-up time was 6.7 months. RESULTS: Acute toxicity included mostly local pain and erythema at the implantation site followed by swelling and mild skin ulceration. For pain and grade 2 skin ulcerations, 90% of patients had resolution within 3 to 5 weeks. Complete response to the Ra-224 DaRT treatment was observed in 22 lesions (22/28; 78.6%); 6 lesions (6/28, 21.4%) manifested a partial response (>30% tumor reduction). Among the 22 lesions with a complete response, 5 (22%) developed a subsequent local relapse at the site of DaRT implantation at a median time of 4.9 months (range, 2.43-5.52 months). The 1-year local progression-free survival probability at the implanted site was 44% overall (confidence interval [CI], 20.3%-64.3%) and 60% (95% CI, 28.61%-81.35%) for complete responders. Overall survival rates at 12 months post-DaRT implantation were 75% (95% CI, 46.14%-89.99%) among all patients and 93% (95% CI, 59.08%-98.96%) among complete responders. CONCLUSIONS: Alpha-emitter brachytherapy using DaRT achieved significant tumor responses without grade 3 or higher toxicities observed. Longer follow-up observations and larger studies are underway to validate these findings.


Asunto(s)
Braquiterapia/métodos , Carcinoma de Células Escamosas/radioterapia , Neoplasias de Cabeza y Cuello/radioterapia , Recurrencia Local de Neoplasia/radioterapia , Radio (Elemento)/uso terapéutico , Neoplasias Cutáneas/radioterapia , Torio/uso terapéutico , Anciano , Anciano de 80 o más Años , Partículas alfa/efectos adversos , Partículas alfa/uso terapéutico , Braquiterapia/efectos adversos , Braquiterapia/instrumentación , Carcinoma de Células Escamosas/patología , Eritema/etiología , Estudios de Factibilidad , Femenino , Neoplasias de Cabeza y Cuello/patología , Humanos , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia/patología , Dolor Asociado a Procedimientos Médicos/etiología , Fotograbar , Proyectos Piloto , Supervivencia sin Progresión , Estudios Prospectivos , Radio (Elemento)/efectos adversos , Seguridad , Neoplasias Cutáneas/patología , Úlcera Cutánea/etiología , Torio/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
2.
Cancer Radiother ; 21(8): 766-773, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29132803

RESUMEN

PURPOSE: The role played by radiation therapy after pleurectomy/decortication or surgical biopsy in malignant pleural mesothelioma is uncertain. We treated patients with accelerated hypofractionated radiotherapy using helical tomotherapy and intensity-modulated arc therapy in an attempt to keep lung toxicity to a minimum. The present study reports the feasibility and toxicity of this approach. MATERIAL AND METHODS: Between 2008 and 2012, 36 patients with malignant pleural mesothelioma underwent accelerated hypofractionated radiotherapy to the hemithorax after pleurectomy/decortication (19 patients) or biopsy (17 patients). The prescription dose was 25Gy in five fractions over 5 consecutive days. RESULTS: We observed three patients with G3 pneumonitis, five cases of grade 2 dyspnea and six cases of grade 2 cough. The median follow-up was 37 months (range: 3-54 months). The median overall survival for patients who underwent pleurectomy/decortication followed by radiotherapy was 21.6 months [95% confidence interval (95% CI): 15.5-24.1] compared to 19.4 months for patients not submitted to surgery. CONCLUSION: Treatment of intact lung with pleural intensity-modulated arc irradiation in malignant pleural mesothelioma patients with malignant pleural mesothelioma proved safe and feasible, with an acceptable rate of pneumonitis. Survival rates were encouraging for both biopsy-only and pleurectomy/decortication groups. We are currently conducting a phase II dose escalation trial in a similar patient setting to prospectively evaluate the impact of radiotherapy on toxicity, disease-free survival and overall survival.


Asunto(s)
Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirugía , Mesotelioma/radioterapia , Mesotelioma/cirugía , Pleura/cirugía , Neoplasias Pleurales/radioterapia , Neoplasias Pleurales/cirugía , Hipofraccionamiento de la Dosis de Radiación , Radioterapia de Intensidad Modulada , Adulto , Anciano , Anciano de 80 o más Años , Biopsia , Terapia Combinada , Femenino , Humanos , Neoplasias Pulmonares/patología , Masculino , Mesotelioma/patología , Mesotelioma Maligno , Persona de Mediana Edad , Neoplasias Pleurales/patología , Estudios Retrospectivos
3.
Appl Radiat Isot ; 105: 273-277, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26356044

RESUMEN

Marinelli beaker systems are used to monitor the activity of radioactive samples. These systems are usually calibrated with water solutions and the determination of the activity in gases requires correction coefficients accounting for the different mass-thickness of the sample. For beta+ radionuclides the different distribution of the positrons annihilation points should be also considered. In this work a Monte Carlo simulation based on Geant4 is used to compute correction coefficients for the measurement of the activity of air samples.


Asunto(s)
Contaminantes Radiactivos del Aire/análisis , Monitoreo de Radiación/métodos , Partículas beta , Calibración , Electrones , Radioisótopos de Flúor/análisis , Rayos gamma , Humanos , Método de Montecarlo , Monitoreo de Radiación/estadística & datos numéricos , Tecnecio/análisis
4.
Biomed Res Int ; 2013: 935351, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23865075

RESUMEN

Kidney dosimetry in (177)Lu and (90)Y PRRT requires 3 to 6 whole-body/SPECT scans to extrapolate the peptide kinetics, and it is considered time and resource consuming. We investigated the most adequate timing for imaging and time-activity interpolating curve, as well as the performance of a simplified dosimetry, by means of just 1-2 scans. Finally the influence of risk factors and of the peptide (DOTATOC versus DOTATATE) is considered. 28 patients treated at first cycle with (177)Lu DOTATATE and 30 with (177)Lu DOTATOC underwent SPECT scans at 2 and 6 hours, 1, 2, and 3 days after the radiopharmaceutical injection. Dose was calculated with our simplified method, as well as the ones most used in the clinic, that is, trapezoids, monoexponential, and biexponential functions. The same was done skipping the 6 h and the 3 d points. We found that data should be collected until 100 h for (177)Lu therapy and 70 h for (90)Y therapy, otherwise the dose calculation is strongly influenced by the curve interpolating the data and should be carefully chosen. Risk factors (hypertension, diabetes) cause a rather statistically significant 20% increase in dose (t-test, P < 0.10), with DOTATATE affecting an increase of 25% compared to DOTATOC (t-test, P < 0.05).


Asunto(s)
Riñón/diagnóstico por imagen , Octreótido/análogos & derivados , Compuestos Organometálicos/farmacocinética , Radiometría , Receptores de Péptidos/metabolismo , Anciano , Anciano de 80 o más Años , Calibración , Estudios de Cohortes , Humanos , Cinética , Persona de Mediana Edad , Octreótido/farmacocinética , Factores de Riesgo , Factores de Tiempo , Tomografía Computarizada de Emisión de Fotón Único , Tomografía Computarizada por Rayos X
5.
Med Phys ; 39(7): 4502-14, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22830782

RESUMEN

PURPOSE: Stereotactic body radiotherapy (SBRT) has been applied to lung tumors at different stages and sizes with good local tumor control (LC) rates. The linear quadratic model (LQM), in its basic formulation, does not seem to be appropriate to describe the response to radiotherapy for clinical trials, based on a few fractions. Thus, the main aim of this work was to develop a model, which takes into account the hypoxic cells and their reoxygenation. METHODS: A parameter named B has been introduced in a modified tumor control probability (TCP) from LQM and linear-quadratic-linear model (LQLM), and represents the fraction of hypoxic cells that survive and become oxygenated after each irradiation. Based on published trials evaluating LC at 3 yr (LC3), values of B were obtained by maximum likelihood minimization between predicted TCP and clinical LC3. Two oxygen enhancement ratio (OER) parameter sets (1 and 2) from literature have been adopted to calculate the B-factors. Initial hypoxic cell fractions (η(h)) from 0.05 to 0.50 were assumed. Log-likelihood (L) and Akaike information criterion (AIC) were determined in an independent clinical validation dataset. RESULTS: The B-values of modified TCPs spanned the whole interval from 0 to 1, depending on the fractionation scheme (number of fractions and dose/fraction), showing a maximum (close to 1) at doses/fraction of 8-12 Gy. The B-values calculated using the OER parameter set 1 exhibited a smoother falloff than set 2. An analytical expression was derived to describe the B-value's dependence on the fractionation scheme. The R(2)-adjusted values varied from 0.63 to 0.67 for LQ models and OER set 1 and from 0.75 to 0.78 for LQ model and OER set 2. Lower values of R(2)-adjusted were found for LQLM and both OER sets. L and AIC, calculated using a fraction of η(h) = 0.15 and the B-value from the authors analytical expression were higher than for other η(h)-values, irrespective of model or OER set. CONCLUSIONS: The authors model allows to predict the clinical outcome associated with SBRT treatment, taking into account both direct killing and indirect vasculature or stromal damage.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/fisiopatología , Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Hipoxia de la Célula , Neoplasias Pulmonares/fisiopatología , Neoplasias Pulmonares/radioterapia , Modelos Biológicos , Planificación de la Radioterapia Asistida por Computador/métodos , Carcinoma de Pulmón de Células no Pequeñas/patología , Simulación por Computador , Fraccionamiento de la Dosis de Radiación , Humanos , Neoplasias Pulmonares/patología , Estadificación de Neoplasias , Radiocirugia , Resultado del Tratamiento
6.
Med Phys ; 35(1): 13-24, 2008 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-18293556

RESUMEN

The effect of the energy dispersion of a quasi-monochromatic x-ray beam on the performance of a dual-energy x-ray imaging system is studied by means of Monte Carlo simulations using MCNPX (Monte Carlo N-Particle eXtended) version 2.6.0. In particular, the case of subtraction imaging at the iodine K-edge, suitable for angiographic imaging application, is investigated. The average energies of the two beams bracketing the iodine K-edge are set to the values of 31.2 and 35.6 keV corresponding to the ones obtained with a compact source based on a conventional x-ray tube and a mosaic crystal monochromator. The energy dispersion of the two beams is varied between 0 and 10 keV of full width at half-maximum (FWHM). The signal and signal-to-noise ratio produced in the simulated images by iodine-filled cavities (simulating patient vessels) drilled in a PMMA phantom are studied as a function of the x-ray energy dispersion. The obtained results show that, for the considered energy separation of 4.4 keV, no dramatic deterioration of the image quality is observed with increasing x-ray energy dispersion up to a FWHM of about 2.35 keV. The case of different beam energies is also investigated by means of fast simulations of the phantom absorption.


Asunto(s)
Angiografía de Substracción Digital/métodos , Yodo/química , Método de Montecarlo , Simulación por Computador , Electrones , Humanos , Fantasmas de Imagen , Fotones , Rayos X
7.
Eur J Nucl Med Mol Imaging ; 35(1): 72-9, 2008 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17874094

RESUMEN

OBJECTIVES: The aim of this work was the evaluation of biodistribution and radiation dosimetry of (68)Ga-DOTANOC in patients affected by neuroendocrine tumors. MATERIALS AND METHODS: We enrolled nine patients (six male and three female) affected by different types of neuroendocrine tumors (NETs). Each patient underwent four whole body positron emission tomography (PET) scans, respectively, at 5, 20, 60, and 120 min after the intravenous injection of about 185 MBq of (68)Ga-DOTANOC. Blood and urine samples were taken at different time points post injection: respectively, at about 5, 18, 40, 60, and 120 min for blood and every 40-50 min from injection time up to 4 h for urine. The organs involved in the dosimetric evaluations were liver, heart, spleen, kidneys, lungs, pituitary gland, and urinary bladder. Dosimetric evaluations were done using the OLINDA/EXM 1.0 software. RESULTS: A physiological uptake of (68)Ga-DOTANOC was seen in all patients in the pituitary gland, the spleen, the liver, and the urinary tract (kidneys and urinary bladder). Organs with the highest absorbed doses were kidneys (9.0E-02+/-3.2E-02mSv/MBq). The mean effective dose equivalent (EDE) was 2.5E-02+/-4.6E-03 mSv/MBq. DISCUSSION AND CONCLUSIONS: The excretion of the compound was principally via urine, giving dose to the kidney and the urinary bladder wall. As SSTR2 is the most frequently expressed somatostatin receptor and (68)Ga-DOTANOC has high affinity to it, this compound might play an important role in PET oncology in the future. The dosimetric evaluation carried out by our team demonstrated that (68)Ga-DOTANOC delivers a dose to organs comparable to, and even lower than, analogous diagnostic compounds.


Asunto(s)
Tumores Neuroendocrinos/diagnóstico por imagen , Tumores Neuroendocrinos/metabolismo , Compuestos Organometálicos/farmacocinética , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tomografía de Emisión de Positrones , Radiometría , Distribución Tisular
8.
Phys Med Biol ; 52(11): 3015-26, 2007 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-17505086

RESUMEN

The aim of the work is to quantitatively compare the effect of the energy separation in the k-edge digital subtraction imaging technique. Images of a custom-made, iodine filled (k-edge = 33.17 keV) test object have been acquired with monochromatic x-ray beams (energy spread <0.1 keV) at the ID17 biomedical beamline of the ESRF. Image acquisition has been performed using two energy separations, namely 0.65 keV (32.85 keV and 33.5 keV, respectively) and 4.4 keV (31.2 keV and 35.6 keV, respectively), using beams of energies on either side of the iodine k-edge. Signal and signal-to-noise ratio (SNR) analysis has been performed as a function of DeltaE and the contrast medium concentrations. The results show that the SNR values measured for DeltaE < 1 keV are only slightly higher than those measured for DeltaE = 4.4 keV. This preliminary study shows that monochromaticity and the energy separation obtained with quasi monochromatic beams from conventional x-ray sources might be suitable for this imaging technique.


Asunto(s)
Diagnóstico por Imagen/métodos , Intensificación de Imagen Radiográfica/métodos , Técnica de Sustracción , Sincrotrones/instrumentación , Biofisica/métodos , Medios de Contraste , Humanos , Procesamiento de Imagen Asistido por Computador , Yodo/química , Modelos Estadísticos , Modelos Teóricos , Fantasmas de Imagen , Fotones , Rayos X
9.
Phys Med Biol ; 51(17): 4311-28, 2006 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-16912383

RESUMEN

The aim of the present work is to analytically evaluate the signal to noise ratio (SNR) and the delivered dose in K-edge digital subtraction imaging (KES) using two types of x-ray sources: a monochromatic x-ray source (available at synchrotron radiation facilities and considered as gold standard) and a quasi-monochromatic compact source. The energy separation DeltaE between the two monochromatic beams is 1 keV and 4 keV for the two sources, respectively. The evaluation has been performed for both radiography and computed tomography. Different geometries have been studied to mimic clinical situations. In mammography, a pathology perfused by a contrast agent has been modelled; in angiography, a vessel superimposed to a ventricle or a stand-alone artery stenosis has been studied. The SNR and the skin dose have been calculated as a function of the detail diameter, the contrast agent (iodine and gadolinium), and its concentration in the tissues. Results show that for DeltaE = 4 keV a slightly higher delivered dose is required to obtain the same SNR with respect to DeltaE < 1 keV. A similar study has been performed for KES-CT. Computer simulations of CT images performed with Snark software are shown to validate the analytical calculations.


Asunto(s)
Angiografía de Substracción Digital/métodos , Medios de Contraste/química , Procesamiento de Señales Asistido por Computador/instrumentación , Técnica de Sustracción , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Gadolinio/química , Humanos , Yodo/química , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
10.
Phys Med Biol ; 51(17): 4233-51, 2006 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-16912379

RESUMEN

Early manifestation of breast cancer is often very subtle and is displayed in a complex and variable pattern of normal anatomy that may obscure the disease. The use of dual-energy techniques, that can remove the structural noise, and contrast media, that enhance the region surrounding the tumour, could help us to improve the detectability of the lesions. The aim of this work is to investigate the use of an iodine-based contrast medium in mammography with two different double exposure techniques: K-edge subtraction mammography and temporal subtraction mammography. Both techniques have been investigated by using an ideal source, like monochromatic beams produced at a synchrotron radiation facility and a clinical digital mammography system. A dedicated three-component phantom containing cavities filled with different iodine concentrations has been developed and used for measurements. For each technique, information about the minimum iodine concentration, which provides a significant enhancement of the detectability of the pathology by minimizing the risk due to high dose and high concentration of contrast medium, has been obtained. In particular, for cavities of 5 and 8 mm in diameter filled with iodine solutions, the minimum concentration needed to obtain a contrast-to-noise ratio of 5 with a mean glandular dose of 2 mGy has been calculated. The minimum concentrations estimated with monochromatic beams and K-edge subtraction mammography are 0.9 mg ml(-1) and 1.34 mg ml(-1) for the biggest and smallest details, respectively, while for temporal subtraction mammography they are 0.84 mg ml(-1) and 1.31 mg ml(-1). With the conventional clinical system the minimum concentrations for the K-edge subtraction mammography are 4.13 mg ml(-1) (8 mm diameter) and 5.75 mg ml(-1) (5 mm diameter), while for the temporal subtraction mammography they are 1.01 mg ml(-1) (8 mm diameter) and 1.57 mg ml(-1) (5 mm diameter).


Asunto(s)
Algoritmos , Medios de Contraste/química , Yodo/química , Técnica de Sustracción , Relación Dosis-Respuesta a Droga , Humanos , Mamografía/instrumentación , Mamografía/métodos , Fantasmas de Imagen , Control de Calidad , Dosis de Radiación , Intensificación de Imagen Radiográfica/métodos
11.
Biomed Imaging Interv J ; 2(4): e60, 2006 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21614340

RESUMEN

Positron emission tomography (PET) is a non-invasive imaging modality, which is clinically widely used both for diagnosis and accessing therapy response in oncology, cardiology and neurology.Fusing PET and CT images in a single dataset would be useful for physicians who could read the functional and the anatomical aspects of a disease in a single shot.The use of fusion software has been replaced in the last few years by integrated PET/CT systems, which combine a PET and a CT scanner in the same gantry. CT images have the double function to correct PET images for attenuation and can fuse with PET for a better visualization and localization of lesions. The use of CT for attenuation correction yields several advantages in terms of accuracy and patient comfort, but can also introduce several artefacts on PET-corrected images.PET/CT image artefacts are due primarily to metallic implants, respiratory motion, use of contrast media and image truncation. This paper reviews different types artefacts and their correction methods.PET/CT improves image quality and image accuracy. However, to avoid possible pitfalls the simultaneous display of both Computed Tomography Attenuation Corrected (CTAC) and non corrected PET images, side by side with CT images is strongly recommended.

12.
Med Phys ; 32(12): 3755-66, 2005 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-16475775

RESUMEN

Dual-energy mammographic imaging experimental tests have been performed using a compact dichromatic imaging system based on a conventional x-ray tube, a mosaic crystal, and a 384-strip silicon detector equipped with full-custom electronics with single photon counting capability. For simulating mammal tissue, a three-component phantom, made of Plexiglass, polyethylene, and water, has been used. Images have been collected with three different pairs of x-ray energies: 16-32 keV, 18-36 keV, and 20-40 keV. A Monte Carlo simulation of the experiment has also been carried out using the MCNP-4C transport code. The Alvarez-Macovski algorithm has been applied both to experimental and simulated data to remove the contrast between two of the phantom materials so as to enhance the visibility of the third one.


Asunto(s)
Mamografía/métodos , Intensificación de Imagen Radiográfica/métodos , Silicio , Algoritmos , Fenómenos Biofísicos , Biofisica , Femenino , Humanos , Mamografía/estadística & datos numéricos , Método de Montecarlo , Fantasmas de Imagen/estadística & datos numéricos
13.
Phys Med Biol ; 49(14): 3291-305, 2004 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-15357198

RESUMEN

This work proposes a compact dichromatic imaging system for the application of the K-edge digital subtraction technique based on a conventional x-ray tube and a monochromator system. A quasi-monochromatic x-ray beam at the energy of iodine K-edge is produced by Bragg diffraction on a mosaic crystal. Two thin adjacent beams with energies that bracket the K-edge discontinuity are obtained from the diffracted beam by means of a proper collimation system. They are then detected using an array of Si detectors. A home-made phantom is used to study the image quality as a function of iodine concentration. Signal and signal-to-noise ratio analysis has also been performed. The results are compared with theoretical expectations.


Asunto(s)
Angiografía de Substracción Digital/métodos , Silicio/química , Rayos X , Medios de Contraste , Cristalización , Humanos , Procesamiento de Imagen Asistido por Computador , Yodo/farmacología , Modelos Estadísticos , Fantasmas de Imagen , Intensificación de Imagen Radiográfica , Técnica de Sustracción , Tecnología Radiológica , Tomografía Computarizada por Rayos X , Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA