Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Rep Pract Oncol Radiother ; 29(1): 77-89, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39165604

RESUMEN

Background: This study aimed to evaluate the dosimetric and radiobiological differences between 6MV flattened filter (FF) and flattening filter free (FFF) using volumetric modulated arc (VMAT) technique for head and neck (H&N) cancer patients. Materials and methods: Fifteen patients with H&N carcinoma were selected and treated with VMAT with FF (VMATFF) treatment plan. Retrospectively, additional VMAT treatment plans were developed using FFF beams (VMATFFF). Radiobiological parameters, such as equivalent uniform dose (EUD), tumor cure probability (TCP), and normal tissue complication probability (NTCP), were calculated using Niemierko's model for both VMATFF and VMATFFF. Correlation between dosimetric and radiobiological data were analyzed and compared. Results: The conformity index (CI) was 0.975 ± 0.014 (VMATFF) and 0.964 ± 0. 019 (VMATFFF) with p ≥ 0.05. Statistically, there was an insignificant difference in the planning target volume (PTV) results for TCP (%) values, with values of 81.20 ± 0.88% (VMATFF) and 81.01 ± 0.92 (%) (VMATFF). Similarly, there was an insignificant difference in the EUD (Gy) values, which were 71.53 ± 0.33 Gy (VMATFF) and 71.46 ± 0.34 Gy (VMATFFF). The NTCP values for the spinal cord, left parotid, and right parotid were 6.54 × 10-07%, 8.04%, and 7.69%, respectively, in the case of VMATFF. For VMATFFF, the corresponding NTCP values for the spinal cord, parotids left, and parotid right were 3.09 × 10-07%, 6.57%, and 6.73%, respectively. Conclusion: The EUD and Mean Dose to PTV were strongly correlated for VMATFFF. An increased mean dose to the PTV and greater TCP were reported for the VMATFF, which can enhance the delivery of the therapeutic dose to the target.

2.
J Biomed Phys Eng ; 13(3): 227-238, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37312893

RESUMEN

Background: As compared to the flattened photon beam, removing the flattening filter (FF) from the head of a gantry decreases the average energy of the photon beam and increases the dose rate, leading to an impact on the quality of treatment plans. Objective: This study aimed to compare the quality of intensity-modulated radiation therapy (IMRT) treatment plans for esophageal cancer with and without a flattened filter photon beam. Material and Methods: In this analytical study, 12 patients, who had already been treated with a 6X FF photon beam, were treated based on new IMRT methods using a 6X the flattening filter-free (FFF) photon beam. Both 6X FF IMRT and 6X FFF IMRT plans used identical beam parameters and planning objectives. All plans were evaluated with planning indices and doses for organs at risk (OARs). Results: Insignificant dose variation was for HI, CI, D98%, and V95% between FF and FFF photon beam IMRT plans. FF-based IMRT plan delivered a 15.51 % and 11.27% higher mean dose to both lungs and heart than the FFF plan, respectively. The integral dose (ID) for the heart and lungs was 11.21% and 15.51%, respectively, less in the IMRT plan with an FFF photon beam. Conclusion: In contrast to the FF photon beam, a filtered photon beam-oriented IMRT plan provides significant OAR sparing without losing the quality of the treatment plan. High monitor units (MUs), low ID, and Beam on Time (BOT) are major highlights of the IMRT plan with FFF beam.

3.
J Med Phys ; 47(4): 336-343, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36908492

RESUMEN

Background: Intensity-modulated radiation therapy (IMRT) may have too many peaks and valleys, making the treatment plan undeliverable. When there are too many fluency differences between adjacent pixels in the X or Y directions, the X and Y smoothing factors are utilized as weighting factors to penalize this behavior. Generally, a high degree of complexity is accompanied by many monitor units (MUs), large number of segments, small sized segments, and complex segment shapes. The degree of plan delivery uncertainty can all increase with a higher detailed fluence map. Aim: This study aims to evaluate the dosimetric effects of various smoothing levels on the planning target volume (PTV) and organs at risk (OARs) for cervix cancer. Materials and Methods: IMRT treatment plans were re-optimized by combining several values of the X and Y penalty between 0 and 100. The dose-volume histogram assessed various dosimetric indicators for PTV and OARs. Additionally, gamma passing rates were evaluated and noted as an indicator of the complex treatment plan. Results: At X = 60, Y = 60 fluence map penalty, the conformity index (CI) value reached its highest value of 0.996 ± 0.004. At X = 0, Y = 0, the homogeneity index (HI) was determined to have a maximum value of 0.0628 ± 0.0235. The highest and lowest MU values were 2424.30 ± 471.12 and 1087.80 ± 91.57, respectively, with X = 0, Y = 0 and X = 100, Y = 100. At X = 100, Y = 100, the gamma passing rate reaches its highest value of 99.28% ± 0.44% and minimum value of 85.93% ± 3.87% at X = 0, Y = 0. Conclusion: The CI and HI values showed no discernible fluctuation, and the OAR doses were barely affected as smoothing was increased. When the smoothing factor was raised, the number of MUs sharply dropped, and a decrease in the number of segments and higher gamma passing rates were also seen.

4.
J Cancer Res Ther ; 17(1): 191-197, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33723154

RESUMEN

BACKGROUND: Iridium-192 (192Ir) has been a widely accepted radioisotope for high-dose-rate (HDR) brachytherapy. Recently, Cobalt-60 (60Co) radioisotope with a longer half-life (5.26 years) has been gaining popularity due to economic and logistical reasons as compared with the traditional 192Ir. AIM: This study aimed to evaluate and compare the integral dose (ID) to the target and organs at risk (OARs) with two HDR brachytherapy sources in brachytherapy treatment of carcinoma uterine cervix to find appropriate HDR radioisotopes for clinical benefit. MATERIALS AND METHODS: This is a retrospective analysis of 52 computed tomography image-based brachytherapy plans of 52 patients who have received intracavitary treatment with 192Ir HDR source. For each patient plan, one additional set of plan was created using 60Co source in place of 192Ir source keeping the same dwell position, and again dose was optimized. The volume and mean dose for target, OARs, and volume structures of 400%, 200%, 150%, 100%, and 50% were recorded for the estimation and comparison of ID. RESULTS: The mean ID to high-risk clinical target volume was significantly higher by 5.84% in 60Co plan than that in 192Ir plan. For OARs, the mean ID to the rectum was significantly higher by 2.60% in 60Co plan as compared to 192Ir plan, whereas for bladder and sigmoid colon, it was lower in 60Co plan than that in 192Ir plan. The mean ID of central dose volume structures of 400%, 200%, 150%, 100%, and 50% was higher by 12.97%, 9.77%, 8.16%, 6.10%, and 3.22%, respectively, in 60Co plan than that of 192Ir plan. CONCLUSION: The results of our study concluded that 192Ir HDR radioisotope should be preferred for intracavitary brachytherapy due to its ideal physical characteristics for better clinical outcomes.


Asunto(s)
Adenocarcinoma/radioterapia , Braquiterapia/métodos , Radioisótopos de Cobalto/administración & dosificación , Radioisótopos de Iridio/administración & dosificación , Órganos en Riesgo/efectos de la radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias del Cuello Uterino/radioterapia , Adenocarcinoma/patología , Femenino , Humanos , Persona de Mediana Edad , Dosificación Radioterapéutica , Recto/patología , Estudios Retrospectivos , Vejiga Urinaria/patología , Neoplasias del Cuello Uterino/patología
5.
J Cancer Res Ther ; 15(6): 1304-1308, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31898664

RESUMEN

CONTEXT: Due to limited resources and/or affordability by majority of the patients, many centers in low- and middle-income countries are still not able to adapt three-dimensional image-based brachytherapy planning in their routine practice. AIM: The aim of the study was to see the feasibility of using computed tomography (CT)-based plan of the first fraction to treat successive fractions of intracavitary brachytherapy based on the estimation of the physical dosimetric differences between successive applications. MATERIALS AND METHODS: CT image-based brachytherapy plans of 38 patients who received three insertions of intracavitary application with high-dose-rate brachytherapy have been analyzed. Revised plans for the second and third insertions were generated by adapting dwell time and dwell position of the first insertion plan. The dose to point "A" and maximum doses to 2, 1, and 0.1 cc volumes of the rectum and bladder have been used for dosimetric comparison. RESULTS: The statistical differences of mean point "A" doses were observed insignificant except between original and revised plans for the second insertions. The dosimetric differences between consecutive original and revised plans for the bladder and rectum have not shown any significance except minimum dose to 0.1 cc volume of the rectum for the third insertions. CONCLUSIONS: Dosimetric deviation for tumor and organs at risk is within acceptable limit while using CT image-based brachytherapy plan of the first fraction for treating successive fractions.


Asunto(s)
Braquiterapia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia Guiada por Imagen , Tomografía Computarizada por Rayos X , Neoplasias del Cuello Uterino/diagnóstico , Neoplasias del Cuello Uterino/radioterapia , Braquiterapia/efectos adversos , Braquiterapia/métodos , Fraccionamiento de la Dosis de Radiación , Femenino , Humanos , Persona de Mediana Edad , Estadificación de Neoplasias , Órganos en Riesgo , Radiometría , Recto/efectos de la radiación , Vejiga Urinaria/efectos de la radiación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA