Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Materials (Basel) ; 16(5)2023 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-36903219

RESUMEN

Rotary swaging is a promising technique for the fabrication of clad Cu/Al composites. Residual stresses appearing during the processing of a special arrangement of Al filaments within the Cu matrix and the influence of the bar reversal between the passes were studied by (i) neutron diffraction using a novel evaluation procedure for pseudo-strain correction and (ii) a finite element method simulation. The initial study of the stress differences in the Cu phase allowed us to infer that the stresses around the central Al filament are hydrostatic when the sample is reversed during the passes. This fact enabled the calculation of the stress-free reference and, consequently, the analysis of the hydrostatic and deviatoric components. Finally, the stresses with the von Mises relation were calculated. Hydrostatic stresses (far from the filaments) and axial deviatoric stresses are zero or compressive for both reversed and non-reversed samples. The reversal of the bar direction slightly changes the overall state within the region of high density of Al filaments, where hydrostatic stresses tend to be tensile, but it seems to be advantageous for avoiding plastification in the regions without Al wires. The finite element analysis revealed the presence of shear stresses; nevertheless, stresses calculated with the von Mises relation show similar trends in the simulation and in the neutron measurements. Microstresses are suggested as a possible reason for the large width of the neutron diffraction peak in the measurement of the radial direction.

2.
Materials (Basel) ; 14(8)2021 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-33917981

RESUMEN

Experimental analyses of depth distributions of phase-specific residual stresses after deep rolling were carried out by means of laboratory X-ray diffraction and neutron diffraction for the two duplex steels X2CrNiMoN22-5-3 and X3CrNiMoN27-5-2, which differ significantly in their ferrite to austenite ratios. The aim of the investigation was to elucidate to which extent comparable results can be achieved with the destructive and the non-destructive approach and how the process induced phase-specific micro residual stresses influence the determination of the phase- and {hkl}-specific reference value d0, required for evaluation of neutron strain scanning experiments. A further focus of the work was the applicability of correction approaches that were developed originally for single-phase materials for accounting for spurious strains during through surface neutron scanning experiments on coarse two-phase materials. The depth distributions of macro residual stresses were separated from the phase-specific micro residual stresses. In this regard, complementary residual stress analysis was carried out by means of incremental hole drilling. The results indicate that meaningful macro residual stress depth distributions can be determined non-destructively by means of neutron diffraction for depths starting at about 150-200 µm. Furthermore, it was shown that the correction of the instrumental surface effects, which are intrinsic for surface neutron strain scanning, through neutron ray-tracing simulation is applicable to multiphase materials and yields reliable results. However, phase-specific micro residual stresses determined by means of neutron diffraction show significant deviations to data determined by means of lab X-ray stress analysis according to the well-known sin2ψ-method.

3.
Materials (Basel) ; 13(23)2020 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-33265936

RESUMEN

Resolution properties of the unconventional high-resolution neutron diffraction three-axis setup for strain/stress measurements of large bulk polycrystalline samples are presented. Contrary to the conventional two-axis setups, in this case, the strain measurement on a sample situated on the second axis is carried out by rocking the bent perfect crystal (BPC) analyzer situated on the third axis of the diffractometer. Thus, the so-called rocking curve provides the sample diffraction profile. The neutron signal coming from the analyzer is registered by a point detector. This new setup provides a considerably higher resolution (at least by a factor of 5), which however, requires a much longer measurement time. The high-resolution neutron diffraction setting can be effectively used, namely, for bulk gauge volumes up to several cubic centimeters, and for plastic deformation studies on the basis of the analysis of diffraction line profiles, thus providing average values of microstructure characteristics over the irradiated gauge volume.

4.
J Appl Crystallogr ; 51(Pt 2): 264-281, 2018 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-29657564

RESUMEN

A global approach coupling the moderator to the beam extraction system has been applied for the design optimization of the thermal and cold moderators of the European Spallation Source (ESS), which will be the brightest neutron source in the world for condensed-matter studies. The design is based on the recently developed high-brightness low-dimensional moderator concepts. Para-hydrogen is used for the cold neutron source, while thermal neutrons are provided by moderation in water. The overall moderation configuration was chosen in order to satisfy a range of requirements on bispectral extraction, beamport configuration and instrument performance. All instruments are served by a single moderator assembly above the target, arranged in a 'butterfly' geometry with a height of 3 cm. This was determined to be the optimal height for trade-off between high brightness and efficient guide illumination, by analysis of the performance of 23 instruments, based on the reference suite of the ESS Technical Design Report. The concept of 'brilliance transfer' is introduced to quantify the performance of the neutron optical system from the source to the sample. The target monolith incorporates a grid of 42 neutron beamports with an average separation of 6°, allowing a free choice between cold and thermal neutron sources at all instrument positions. With the large number of beamports and the space below the target available for future moderators, ample opportunities are available for future upgrades.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...