Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Anesth Analg ; 127(3): 744-752, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29256940

RESUMEN

BACKGROUND: The effect of neither transfusion guidelines nor decision support tools on intraoperative transfusion has been previously evaluated. The University of Michigan introduced a transfusion guideline in 2009, and in 2011, the Department of Anesthesiology developed a transfusion decision support tool. The primary aim of this study was to assess the associations of the transfusion guideline and the optional use of the software transfusion tool with intraoperative behaviors; pretransfusion hematocrit assessment (whether or not a hematocrit was checked before each red cell unit) and restrictive red cell use (withholding transfusion unless the hematocrit was ≤21%). METHODS: This was a before-after retrospective study without a concurrent control group of patients transfused 1-3 units of red cells intraoperatively. Three phases were studied to provide data both before and after the implementation of the transfusion guideline and the intraoperative software tool. Within each phase, trends of checking hematocrits before transfusion and restrictive transfusion were charted against time. F tests were used to measure differences of slopes. The difference between means of each phase was measured using Mann-Whitney U tests. Independent associations were measured using mixed-effects multivariable logistic regression. A secondary outcome analysis was conducted for 30-day mortality, myocardial infarction, renal injury, and their combination. RESULTS: The transfusion guideline was associated with increased pretransfusion hematocrit evaluation (67.4%, standard deviation [SD] 3.9 vs 76.5%, SD 2.7; P < .001) and restrictive transfusion practice (14.0%, SD 7.4 vs 33.3%, SD 4.4; P = .001). After adjustment for confounders, the guideline phase was independently associated with increased hematocrit checking (odds ratio, 1.72; 95% confidence interval, 1.46-2.03; P < .001) and restrictive red cell transfusion (odds ratio, 2.95; 95% confidence interval, 2.46-3.54; P < .001). The software tool was not associated with either transfusion behavior. There was no significant change in the rate of renal injury (16.06%), myocardial injury (4.93%), 30-day mortality (5.47%), or a composite (21.90%). CONCLUSIONS: The introduction of a transfusion guideline was independently associated with increased intraoperative pretransfusion hematocrit assessment and restrictive transfusion. The use of a software tool did not further influence either behavior.


Asunto(s)
Transfusión de Eritrocitos/normas , Cuidados Intraoperatorios/normas , Guías de Práctica Clínica como Asunto/normas , Programas Informáticos/normas , Adulto , Anciano , Transfusión de Eritrocitos/métodos , Femenino , Hematócrito/métodos , Hematócrito/normas , Humanos , Cuidados Intraoperatorios/métodos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/prevención & control , Estudios Retrospectivos
2.
Anesthesiology ; 127(5): 903-904, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-29040107
3.
Indian J Clin Biochem ; 32(1): 68-73, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28149015

RESUMEN

This study evaluates the role of quercetin on the expression of urea cycle enzymes, astrocytic, neuronal and inflammatory markers in hyperammonemic rats. Hyperammonemia (provoked by intraperitonial injections of (ammonium chloride-100 mg/kg b.w for 56 days), showed diminished expression of urea cycle enzymes [carbamyl phosphate synthetase-1 (CPS-1), ornithine transcarbamylase (OTC), argininosuccinate synthetase (ASS) and arginase (ARG)] in liver and decreased expression of neuronal and astrocytic markers-glutamine synthase (GS) and phosphate activated glutaminase (PAG) in brain and increased expression of brain inflammatory markers such as interleukin 6 (IL6), inducible nitric oxide synthase (iNOS) and nuclear transcription factor kappa B (NF-κB) (by western blot analysis) and exhibited downregulated expression of soluble guanylate cyclase (sGC), glial fibrillary acidic protein (GFAP) in brain and ASS in liver investigated (by RT-PCR). Oral treatment of quercetin (50 mg/kg b.w) to hyperammonemic rats (1) increased the expression of urea cycle enzymes (CPS-1, OTC, ASS and ARG), neuronal and astrocytic markers (GS and PAG) (2) decreased the expression of IL6, iNOS and NF-κB and (3) upregulated mRNA expression of SGC, GFAP and ASS. Our results specify that quercetin's antihyperammonemic effects could be through its, anti-inflammatory, neuroprotective and hepatoprotective effects.

4.
Anesthesiology ; 126(3): 450-460, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28059837

RESUMEN

BACKGROUND: Patients with left ventricular assist devices presenting for noncardiac surgery are increasingly commonplace; however, little is known about their outcomes. Accordingly, the authors sought to determine the frequency of complications, risk factors, and staffing patterns. METHODS: The authors performed a retrospective study at their academic tertiary care center, investigating all adult left ventricular assist device patients undergoing noncardiac surgery from 2006 to 2015. The authors described perioperative profiles of noncardiac surgery cases, including patient, left ventricular assist device, surgical case, and anesthetic characteristics, as well as staffing by cardiac/noncardiac anesthesiologists. Through univariate and multivariable analyses, the authors studied acute kidney injury as a primary outcome; secondary outcomes included elevated serum lactate dehydrogenase suggestive of left ventricular assist device thrombosis, intraoperative bleeding complication, and intraoperative hypotension. The authors additionally studied major perioperative complications and mortality. RESULTS: Two hundred and forty-six patients underwent 702 procedures. Of 607 index cases, 110 (18%) experienced postoperative acute kidney injury, and 16 (2.6%) had elevated lactate dehydrogenase. Of cases with complete blood pressure data, 176 (27%) experienced intraoperative hypotension. Bleeding complications occurred in 45 cases (6.4%). Thirteen (5.3%) patients died within 30 days of surgery. Independent risk factors associated with acute kidney injury included major surgical procedures (adjusted odds ratio, 4.4; 95% CI, 1.1 to 17.3; P = 0.03) and cases prompting invasive arterial line monitoring (adjusted odds ratio, 3.6; 95% CI, 1.3 to 10.3; P = 0.02) or preoperative fresh frozen plasma transfusion (adjusted odds ratio, 1.7; 95% CI, 1.1 to 2.8; P = 0.02). CONCLUSIONS: Intraoperative hypotension and acute kidney injury were the most common complications in left ventricular assist device patients presenting for noncardiac surgery; perioperative management remains a challenge.


Asunto(s)
Anestesiólogos/estadística & datos numéricos , Corazón Auxiliar/estadística & datos numéricos , Complicaciones Intraoperatorias/epidemiología , Complicaciones Posoperatorias/epidemiología , Procedimientos Quirúrgicos Operativos , Centros Médicos Académicos , Competencia Clínica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Estudios Retrospectivos , Factores de Riesgo , Centros de Atención Terciaria
5.
BMC Anesthesiol ; 15: 185, 2015 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-26685884

RESUMEN

The use of ventricular assist devices has expanded significantly since their approval by the Food and Drug Administration in the United States in 1994. In addition to this, the prevalence of heart failure continues to increase. We aim to provide an overview of perioperative considerations and management of these patients for non-cardiac surgery. We performed a Medline search for the words "ventricular assist device," "Heartmate" and "HeartWare" to gain an overview of the literature surrounding these devices, and chose studies with relevance to the stated aims of this review. Patients with ventricular assist devices are presenting more frequently for surgery not related to their cardiac pathology. As the mechanically supported population grows, general anesthesiologists will be faced with managing these patients, possibly outside of the tertiary care setting. The unique challenges of this patient population can best be addressed by a thorough understanding of ventricular assist device physiology and a multidisciplinary approach to care.


Asunto(s)
Anestesiología , Corazón Auxiliar , Atención Perioperativa , Procedimientos Quirúrgicos Operativos , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/terapia , Diseño de Equipo , Ventrículos Cardíacos/fisiopatología , Humanos , Estados Unidos
6.
Anesthesiology ; 123(1): 29-37, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26001031

RESUMEN

BACKGROUND: Hyperglycemia, defined as blood glucose (BG) levels above 200 mg/dl (11.1 mM), is associated with increased postoperative morbidity. Yet, the treatment standard for intraoperative glycemic control is poorly defined for noncardiac surgery. Little is known of the interindividual treatment variability or methods to modify intraoperative glycemic management behaviors. AlertWatch (AlertWatch, USA) is a novel audiovisual alert system that serves as a secondary patient monitor for use in operating rooms. The authors evaluated the influence of use of AlertWatch on intraoperative glycemic management behavior. METHODS: AlertWatch displays historical patient data (risk factors and laboratory results) from multiple networked information systems, combined with the patient's live physiologic data. The authors extracted intraoperative data for 19 months to evaluate the relationship between AlertWatch usage and initiation of insulin treatment for hyperglycemia. Outcome associations were adjusted for physical status, case duration, procedural complexity, emergent procedure, fasting BG value, home insulin therapy, patient age, and primary anesthetist. RESULTS: Overall, 2,341 patients had documented intraoperative hyperglycemia. Use of AlertWatch (791 of 2,341; 33.5%) was associated with 55% increase in insulin treatment (496 of 791 [62.7%] with and 817 of 1,550 [52.7%] without AlertWatch; adjusted odds ratio [95% CI], 1.55 [1.23 to 1.95]; P < 0.001) and 44% increase in BG recheck after insulin administration (407 of 791 [51.5%] with AlertWatch and 655 of 1,550 [42.3%] in controls; adjusted odds ratio [95% CI], 1.44 [1.14 to 1.81]; P = 0.002). CONCLUSION: AlertWatch is associated with a significant increase in desirable intraoperative glycemic management behavior and may help achieve tighter intraoperative glycemic control.


Asunto(s)
Recursos Audiovisuales , Terapia Conductista/métodos , Sistemas de Computación , Hiperglucemia/sangre , Hiperglucemia/diagnóstico , Monitoreo Intraoperatorio/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Terapia Conductista/instrumentación , Glucemia/metabolismo , Manejo de la Enfermedad , Femenino , Humanos , Hiperglucemia/cirugía , Masculino , Persona de Mediana Edad , Monitoreo Intraoperatorio/instrumentación , Estudios Retrospectivos , Adulto Joven
7.
J Anaesthesiol Clin Pharmacol ; 30(1): 106-8, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24574607

RESUMEN

We present a patient with known prothrombin gene mutation and a history of prior vascular events, who underwent living donor kidney transplantation. Given the presumed elevated risk of complication from known prothrombin mutation, clinical management was directed towards optimizing living donor allograft function.

8.
A A Case Rep ; 3(11): 149-52, 2014 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-25612102

RESUMEN

In this report, we describe a case of posterior reversible encephalopathy syndrome in a female patient after deceased donor liver transplantation. She developed posterior reversible encephalopathy syndrome on postoperative day 3 and did not improve despite adjustments in immunosuppressive therapy. The patient had symptoms of severe brain edema requiring maximal therapy, which included cooling, mannitol, 3% saline, and a pentobarbital infusion. Attempts to lighten the level of sedation failed because of recurring intractable seizure activity. Reductions in therapeutic support were ultimately successful after 62 days of continuous pentobarbital therapy. The patient awoke neurologically intact and was discharged to a rehabilitation center in good condition.

9.
J Neurosurg Anesthesiol ; 25(1): 62-5, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22871952

RESUMEN

BACKGROUND: Controversy exists regarding the increased safety profile when ultrasound is used for central venous catheters inserted in the subclavian or axillary vein. The critically ill neurosurgical patient presents unique considerations for the optimal central line approach. METHODS: This report is a retrospective chart review of 6 neurosurgical intensive care patients in whom an ultrasound-guided, transpectoral, axillary vein catheterization was attempted. A sterile technique was observed. The anatomy was confirmed using combined transverse, longitudinal, and Doppler flow images. The needle tip was advanced into the axillary vein under real-time ultrasound using an in-plane technique. The central venous catheter was inserted using the Seldinger technique. A chest radiograph was obtained after each line. RESULTS: Five of the 6 central lines were inserted easily, without complications. The sixth central line was inserted without complications but more proximally because of difficulty in visualizing the axillary vein on account of the patient's morbid obesity and severe hypovolemia. CONCLUSIONS: This series illustrates new and useful aspects of ultrasound use in transpectoral axillary vein catheterization: it requires minimal additional training; it combines the real time, in-plane technique with transverse, longitudinal, and Doppler color flow images; and it is used safely in the critically ill neurosurgical patient. The data on infraclavicular central venous catheters indicate decreased line sepsis, arterial punctures, and venous thrombosis while improving nursing care and patient comfort. This technique's potential for decreasing the risk of pneumothorax may make it a reasonable option for many critically ill patients in whom other central venous catheter approaches may not be ideal.


Asunto(s)
Vena Axilar/diagnóstico por imagen , Cateterismo Venoso Central/métodos , Cuidados Críticos/métodos , Procedimientos Neuroquirúrgicos/métodos , Sistemas de Computación , Humanos , Flujometría por Láser-Doppler , Neumotórax/prevención & control , Radiografía Torácica , Estudios Retrospectivos , Posición Supina , Pared Torácica/diagnóstico por imagen , Ultrasonografía Intervencional
11.
J Anaesthesiol Clin Pharmacol ; 28(1): 101-5, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22345955

RESUMEN

The use of mechanical circulatory support devices as a bridge to transplant or destination therapy decreases mortality, improves quality of life, and functional status. The paucity of clinical data and the challenges faced by noncardiac anesthesiologists warrant us to present the perioperative care of a patient with a HeartMate II (Thoratec Corp. Pleasanton, CA, USA) left ventricular assist device (LVAD), who underwent a successful major laparoscopic abdominal surgery. Key issues highlighted are the limitations of oxygen saturation (SpO(2)) monitoring, accuracy of blood pressure (BP) measurement, and the potential usefulness of intraoperative transesophageal echocardiography (TEE). The hemodynamic changes, impact on the LVAD function during laparoscopic surgery, and the multidisciplinary approach are addressed.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...