3.
Rofo ; 184(5): 420-6, 2012 May.
Artículo en Alemán | MEDLINE | ID: mdl-22198836

RESUMEN

Magnetic particle imaging (MPI) displays the spatial distribution and concentration of superparamagnetic iron oxides (SPIOs). It is a quantitative, tomographic imaging method with high temporal and spatial resolution and allows work with high sensitivity yet without ionizing radiation. Thus, it may be a very promising tool for medical imaging. In this review, we describe the physical and technical basics and various concepts for clinical scanners. Furthermore, clinical applications such as cardiovascular imaging, interventional procedures, imaging and therapy of malignancies as well as molecular imaging are presented.


Asunto(s)
Diagnóstico por Imagen/instrumentación , Diagnóstico por Imagen/métodos , Magnetismo , Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/terapia , Compuestos Férricos/análisis , Hemodinámica , Humanos , Imagen Molecular , Neoplasias/diagnóstico , Neoplasias/terapia
4.
Phys Med Biol ; 55(6): 1577-89, 2010 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-20164532

RESUMEN

Magnetic particle imaging (MPI) is a new imaging technique capable of imaging the distribution of superparamagnetic particles at high spatial and temporal resolution. For the reconstruction of the particle distribution, a system of linear equations has to be solved. The mathematical solution to this linear system can be obtained using a least-squares approach. In this paper, it is shown that the quality of the least-squares solution can be improved by incorporating a weighting matrix using the reciprocal of the matrix-row energy as weights. A further benefit of this weighting is that iterative algorithms, such as the conjugate gradient method, converge rapidly yielding the same image quality as obtained by singular value decomposition in only a few iterations. Thus, the weighting strategy in combination with the conjugate gradient method improves the image quality and substantially shortens the reconstruction time. The performance of weighting strategy and reconstruction algorithms is assessed with experimental data of a 2D MPI scanner.


Asunto(s)
Aumento de la Imagen/métodos , Magnetismo , Nanopartículas del Metal/química , Imagen Molecular/métodos , Algoritmos , Análisis de los Mínimos Cuadrados , Tamaño de la Partícula , Sensibilidad y Especificidad , Factores de Tiempo
5.
Phys Med Biol ; 54(2): 385-97, 2009 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-19098358

RESUMEN

Recently a new imaging technique called magnetic particle imaging was proposed. The method uses the nonlinear response of magnetic nanoparticles when a time varying magnetic field is applied. Spatial encoding is achieved by moving a field-free point through an object of interest while the field strength in the vicinity of the point is high. A resolution in the submillimeter range is provided even for fast data acquisition sequences. In this paper, a simulation study is performed on different trajectories moving the field-free point through the field of view. The purpose is to provide mandatory information for the design of a magnetic particle imaging scanner. Trajectories are compared with respect to density, speed and image quality when applied in data acquisition. Since simulation of the involved physics is a time demanding task, moreover, an efficient implementation is presented utilizing caching techniques.


Asunto(s)
Magnetismo , Nanopartículas del Metal , Tomografía/métodos , Algoritmos , Ingeniería Biomédica , Fenómenos Biofísicos , Humanos , Procesamiento de Imagen Asistido por Computador , Modelos Teóricos , Nanotecnología , Dinámicas no Lineales , Fantasmas de Imagen , Tomografía/instrumentación , Tomografía/estadística & datos numéricos