1.
Struct Dyn ; 10(4): 044302, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37577135

RESUMEN

The direct observation of the structure of micrometer-sized vapor-deposited ice is performed at Pohang Accelerator Laboratory x-ray free electron laser (PAL-XFEL). The formation of micrometer-sized ice crystals and their structure is important in various fields, including atmospheric science, cryobiology, and astrophysics, but understanding the structure of micrometer-sized ice crystals remains challenging due to the lack of direct observation. Using intense x-ray diffraction from PAL-XFEL, we could observe the structure of micrometer-sized vapor-deposited ice below 150 K with a thickness of 2-50 µm grown in an ultrahigh vacuum chamber. The structure of the ice grown comprises cubic and hexagonal sequences that are randomly arranged to produce a stacking-disordered ice. We observed that ice with a high cubicity of more than 80% was transformed to partially oriented hexagonal ice when the thickness of the ice deposition grew beyond 5 µm. This suggests that precise temperature control and clean deposition conditions allow µm-thick ice films with high cubicity to be grown on hydrophilic Si3N4 membranes. The low influence of impurities could enable in situ diffraction experiments of ice nucleation and growth from interfacial layers to bulk ice.

2.
Opt Express ; 30(3): 3443-3454, 2022 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-35209602

RESUMEN

Controlling the line shape of Fano resonance has continued to attract significant research attention in recent years owing to its practical applications such as lasing, biosensing, and slow-light devices. However, controllable Fano resonances always require stringent alignment of complex symmetry-breaking structures; therefore, the manipulation can only be performed with limited degrees of freedom and a narrow tuning range. This work demonstrates dark-mode excitation tuning independent of the bright mode for the first time, to the authors' knowledge, in asymmetric Fano metamaterials. Metallic subwavelength slits are arranged to form asymmetric unit cells and generate a broad and bright (radiative) Fabry-Perot mode and a sharp and dark (non-radiative) surface mode. The introduction of the independent radial and angular asymmetries realizes independent control of the Fano phase (q) and quality factor (Q). This tunability provides a dynamic phase shift while maintaining a high-quality factor, enabling switching between nearly perfect transmission and absorption, which is confirmed both numerically and experimentally. The proposed scheme for fully controlled Fano systems can aid practical applications such as phase-sensitive switching devices.

3.
Proc Natl Acad Sci U S A ; 117(50): 31665-31673, 2020 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-33257543

RESUMEN

Fingerprints are unique to primates and koalas but what advantages do these features of our hands and feet provide us compared with the smooth pads of carnivorans, e.g., feline or ursine species? It has been argued that the epidermal ridges on finger pads decrease friction when in contact with smooth surfaces, promote interlocking with rough surfaces, channel excess water, prevent blistering, and enhance tactile sensitivity. Here, we found that they were at the origin of a moisture-regulating mechanism, which ensures an optimal hydration of the keratin layer of the skin for maximizing the friction and reducing the probability of catastrophic slip due to the hydrodynamic formation of a fluid layer. When in contact with impermeable surfaces, the occlusion of the sweat from the pores in the ridges promotes plasticization of the skin, dramatically increasing friction. Occlusion and external moisture could cause an excess of water that would defeat the natural hydration balance. However, we have demonstrated using femtosecond laser-based polarization-tunable terahertz wave spectroscopic imaging and infrared optical coherence tomography that the moisture regulation may be explained by a combination of a microfluidic capillary evaporation mechanism and a sweat pore blocking mechanism. This results in maintaining an optimal amount of moisture in the furrows that maximizes the friction irrespective of whether a finger pad is initially wet or dry. Thus, abundant low-flow sweat glands and epidermal furrows have provided primates with the evolutionary advantage in dry and wet conditions of manipulative and locomotive abilities not available to other animals.


Asunto(s)
Dedos/anatomía & histología , Fuerza de la Mano/fisiología , Locomoción/fisiología , Actividad Motora/fisiología , Primates/fisiología , Adulto , Animales , Evolución Biológica , Dermatoglifia , Dedos/diagnóstico por imagen , Dedos/fisiología , Fricción , Humanos , Masculino , Microfluídica , Sudor/química , Sudor/metabolismo , Glándulas Sudoríparas/química , Glándulas Sudoríparas/metabolismo , Tomografía de Coherencia Óptica
4.
Rev Sci Instrum ; 91(11): 113306, 2020 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-33261443

RESUMEN

Versatile high-power pulsed electron-beam accelerators that meet the requirements of pulsed high-power specifications are needed for appropriate applications in medical industry, defense, and other industries. The pulsed electron beam accelerator comprising a Marx generator and Blumlein pulse forming line (PFL) is designed to accelerate the electron beams at the level of 1 MeV when electrostatically discharging. The performance specifications of Marx generators consisting of a 100 kV DC power supply, R-L-C circuit, and high voltage switch are at a maximum 800 kV. At this time, by using the capacitance mismatching principle between the Marx generator and the Blumlein PFL under the law of preserving the amount of charge, it is possible to generate a high voltage in the form of a square pulse up to about 1.1 MV, as much as 1.37 times the charged voltage of the Marx generator. As a result, energy transmission from the Marx generator with a high efficiency of about 85% to the Blumlein PFL is possible. The aim of this study is that the pulsed high-power electron-beam accelerator can be used to change the diode impedance, and the energy of the accelerated electron beam reaches a level of 1 MeV with the square pulse width of about 100 ns at the flat-top in the range of relativistic electron beam generation. Performance tests were securely carried out by installing a dummy load based on CuSO4 solution varying the diode impedance to deter damage to the circuit by preventing reflected waves from being generated in the load.

5.
Rev Sci Instrum ; 88(1): 014704, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28147680

RESUMEN

Non-thermal irreversible electroporation (NTIRE) to avoid thermal damage to cells during intense DC ns pulsed electric fields (nsPEFs) is a recent modality for medical applications. This mechanism, related to bioelectrical dynamics of the cell, is linked to the effect of a DC electric field and a threshold effect with an electrically stimulated membrane for the charge distribution in the cell. To create the NTIRE condition, the pulse width of the nsPEF should be shorter than the charging time constant of the membrane related to the cell radius, membrane capacitance, cytoplasm resistivity, and medium resistivity. It is necessary to design and fabricate a very intense nanosecond DC electric field pulser that is capable of producing voltages up to the level of 100 kV/cm with an artificial pulse width (∼ns) with controllable repetition rates. Many devices to generate intense DC nsPEF using various pulse-forming line technologies have been introduced thus far. However, the previous Blumlein pulse-generating devices are clearly inefficient due to the energy loss between the input voltage and the output voltage. An improved two-stage stacked Blumlein pulse-forming line can overcome this limitation and decrease the energy loss from a DC power supply. A metal oxide silicon field-effect transistor switch with a fast rise and fall time would enable a high repetition rate (max. 100 kHz) and good endurance against very high voltages (DC ∼ 30 kV). The load is designed to match the sample for exposure to cell suspensions consisting of a 200 Ω resistor matched with a Blumlein circuit and two electrodes without the characteristic RC time effect of the circuit (capacitance =0.174 pF).

6.
Opt Express ; 22(3): 3039-44, 2014 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-24663594

RESUMEN

Metallic metamaterials with positive dielectric responses are promising as an alternative to dielectrics for the generation of Cerenkov radiation [J.-K. So et al., Appl. Phys. Lett. 97(15), 151107 (2010)]. We propose here by theoretical analysis a mechanism to couple out Cerenkov radiation from the slab surfaces in the transverse direction. The proposed method based on Brillouin-zone folding is to periodically modify the thickness of the metamaterial slab in the axial direction. Moreover, the intensity of the surface-coupled radiation by this mechanism shows an order-of-magnitude enhancement compared to that of ordinary Smith-Purcell radiation.