1.
Biomed Phys Eng Express ; 9(5)2023 08 03.
Artículo en Inglés | MEDLINE | ID: mdl-37473741

RESUMEN

Objective. Full-field digital mammography (FFDM) systems manufactured by Hologic that utilise either a 2D or linear anti-scatter grid have recently been installed in our clinic. The manufacturer advise that for matched dose, both grids deliver comparable image quality. The aim of this study was to test the manufacturer's claim using advanced physical image quality metrics and to inform whether the different grids are indeed dose neutral.Approach. Effective detective quantum efficiency (eDQE), effective noise equivalent quanta (eNEQ) and effective dose efficiency (eDE) were measured on a Hologic Dimensions (2D grid) and a Hologic 3Dimensions (linear grid) FFDM system, both calibrated at installation to provide matched threshold contrast, according to the EUREF protocol. eDQE, eNEQ and eDE were calculated and compared using 2, 4, 6 and 7 cm thicknesses of poly (methyl methacrylate) (PMMA) to simulate a clinically appropriate range of breast thicknesses. The beam qualities (target/filter and kilovoltage) chosen were identical between the two systems.Main results. All image quality metrics investigated show that the 2D grid outperforms the linear grid across all spatial frequencies. Furthermore, mean glandular dose (MGD) must be increased by up to 38% on those units that utilise the linear grid if eNEQ is to be matched, although MGD to the standard breast remains within NHSBSP tolerance and below the UK diagnostic reference level. The gradient and shape of each curve was the same irrespective of which grid was used, suggesting that subtle lesions (low frequency information) and micro-calcifications (high frequency information) will be imaged just as efficiently with a linear or 2D grid.Significance. If image quality is to be matched between those units utilising 2D and linear grids, dose must be increased on the latter. This information will be useful to the medical physicist tasked with the optimisation and standardisation of Hologic FFDM units.


Asunto(s)
Calcinosis , Intensificación de Imagen Radiográfica , Humanos , Fantasmas de Imagen , Intensificación de Imagen Radiográfica/métodos , Mamografía/métodos , Polimetil Metacrilato
2.
J Radiol Prot ; 39(3): 938-949, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31382249

RESUMEN

The aim of this study was to demonstrate the usefulness of large sample size patient dose audits for optimisation of CT automatic exposure control (AEC) settings, even when the investigation is limited to only three scanners at a single institution. Pre-optimisation patient dose audits of common CT examinations (n > 200 for each protocol) on three CT scanners (two Philips Brilliance and one Toshiba Aquilion) using radiology information system (RIS) data were conducted showing sub-optimal CT AEC performance on the Toshiba scanner. Based on these results, an optimisation exercise was carried out on the non-optimally performing scanner by phantom measurement and investigation of system configuration. Post-optimisation patient dose audits were subsequently carried out to assess the success of the optimisation exercise demonstrating standardisation of doses; median dose-length-product values were reduced by up to 43% on the sub-optimal scanner without any adverse effect on clinical image quality. This study has demonstrated that large sample patient dose audits using RIS data can be instrumental in identifying and rectifying sub-optimal CT AEC performance, even when the investigation is limited to only three scanners at a single institution.


Asunto(s)
Dosis de Radiación , Tomografía Computarizada por Rayos X/normas , Humanos , Fantasmas de Imagen , Sistemas de Información Radiológica , Tamaño de la Muestra , Tomógrafos Computarizados por Rayos X
3.
Phys Med Biol ; 63(2): 025025, 2018 01 16.
Artículo en Inglés | MEDLINE | ID: mdl-29260730

RESUMEN

Effective detective quantum efficiency (eDQE) describes the resolution and noise properties of an imaging system along with scatter and primary transmission, all measured under clinically appropriate conditions. Effective dose efficiency (eDE) is the eDQE normalised to mean glandular dose and has been proposed as a useful metric for the optimisation of clinical imaging systems. The aim of this study was to develop a methodology for measuring eDQE and eDE on a Philips microdose mammography (MDM) L30 photon counting scanning system, and to compare performance with two conventional flat panel systems. A custom made lead-blocker was manufactured to enable the accurate determination of dose measurements, and modulation transfer functions were determined free-in-air at heights of 2, 4 and 6 cm above the breast support platform. eDQE were calculated for a Philips MDM L30, Hologic Dimensions and Siemens Inspiration digital mammography system for 2, 4 and 6 cm thick poly(methyl methacrylate) (PMMA). The beam qualities (target/filter and kilovoltage) assessed were those selected by the automatic exposure control, and anti-scatter grids were used where available. Measurements of eDQE demonstrate significant differences in performance between the slit- and scan-directions for the photon counting imaging system. MTF has been shown to be the limiting factor in the scan-direction, which results in a rapid fall in eDQE at mid-to-high spatial frequencies. A comparison with two flat panel mammography systems demonstrates that this may limit image quality for small details, such as micro-calcifications, which correlates with a more conventional image quality assessment with the CDMAM phantom. eDE has shown the scanning photon counting system offers superior performance for low spatial frequencies, which will be important for the detection of large low contrast masses. Both eDQE and eDE are proposed as useful metrics that should enable optimisation of the Philips MDM L30.


Asunto(s)
Mama/diagnóstico por imagen , Mamografía/instrumentación , Mamografía/métodos , Fantasmas de Imagen , Teoría Cuántica , Intensificación de Imagen Radiográfica/métodos , Femenino , Humanos
4.
Phys Med Biol ; 62(18): 7379-7393, 2017 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-28742062

RESUMEN

The use of computer simulated digital x-radiographs for optimisation purposes has become widespread in recent years. To make these optimisation investigations effective, it is vital simulated radiographs contain accurate anatomical and system noise. Computer algorithms that simulate radiographs based solely on the incident detector x-ray intensity ('dose') have been reported extensively in the literature. However, while it has been established for digital mammography that x-ray beam quality is an important factor when modelling noise in simulated images there are no such studies for diagnostic imaging of the chest, abdomen and pelvis. This study investigates the influence of beam quality on image noise in a digital radiography (DR) imaging system, and incorporates these effects into a digitally reconstructed radiograph (DRR) computer simulator. Image noise was measured on a real DR imaging system as a function of dose (absorbed energy) over a range of clinically relevant beam qualities. Simulated 'absorbed energy' and 'beam quality' DRRs were then created for each patient and tube voltage under investigation. Simulated noise images, corrected for dose and beam quality, were subsequently produced from the absorbed energy and beam quality DRRs, using the measured noise, absorbed energy and beam quality relationships. The noise images were superimposed onto the noiseless absorbed energy DRRs to create the final images. Signal-to-noise measurements in simulated chest, abdomen and spine images were within 10% of the corresponding measurements in real images. This compares favourably to our previous algorithm where images corrected for dose only were all within 20%.


Asunto(s)
Simulación por Computador , Procesamiento de Imagen Asistido por Computador/normas , Mamografía/normas , Fantasmas de Imagen , Intensificación de Imagen Radiográfica/normas , Tomografía Computarizada por Rayos X/normas , Algoritmos , Humanos , Mamografía/métodos , Intensificación de Imagen Radiográfica/métodos , Procesamiento de Señales Asistido por Computador
5.
Br J Radiol ; 88(1055): 20150364, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26419892

RESUMEN

OBJECTIVE: The purpose of this study was to develop size-based radiotherapy kilovoltage cone beam CT (CBCT) protocols for the pelvis. METHODS: Image noise was measured in an elliptical phantom of varying size for a range of exposure factors. Based on a previously defined "small pelvis" reference patient and CBCT protocol, appropriate exposure factors for small, medium, large and extra-large patients were derived which approximate the image noise behaviour observed on a Philips CT scanner (Philips Medical Systems, Best, Netherlands) with automatic exposure control (AEC). Selection criteria, based on maximum tube current-time product per rotation selected during the radiotherapy treatment planning scan, were derived based on an audit of patient size. RESULTS: It has been demonstrated that 110 kVp yields acceptable image noise for reduced patient dose in pelvic CBCT scans of small, medium and large patients, when compared with manufacturer's default settings (125 kVp). Conversely, extra-large patients require increased exposure factors to give acceptable images. 57% of patients in the local population now receive much lower radiation doses, whereas 13% require higher doses (but now yield acceptable images). CONCLUSION: The implementation of size-based exposure protocols has significantly reduced radiation dose to the majority of patients with no negative impact on image quality. Increased doses are required on the largest patients to give adequate image quality. ADVANCES IN KNOWLEDGE: The development of size-based CBCT protocols that use the planning CT scan (with AEC) to determine which protocol is appropriate ensures adequate image quality whilst minimizing patient radiation dose.


Asunto(s)
Tamaño Corporal , Tomografía Computarizada de Haz Cónico/métodos , Pelvis/diagnóstico por imagen , Artefactos , Humanos , Fantasmas de Imagen , Dosis de Radiación