J Pharm Biomed Anal ; 246: 116215, 2024 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-38759319

RESUMEN

Peripherally inserted central catheters (PICC-lines) used in neonatology are made of thermoplastic polyurethane (TPU) or silicone. These materials usually contain substances that may leach into drug vehicles or blood. In this extractables study, we determined the optimal extraction conditions using TPU films containing defined amounts of butylhydroxytoluene (BHT) and then applied them on unused and explanted PICC-lines. Maceration and sonication tests were carried out with hexane, acetone and water as the extraction solvents. The analyses were performed using gas and liquid chromatography coupled with mass spectrometry detectors, as well as inductive coupled plasma optical emission spectroscopy to detect a wide range of extractables. We selected a limited list of substances to be sought from the usual adjuvants and monomers, related to their carcinogenic, mutagenic or reprotoxic properties and/or existence in endocrine disruptors lists. The TPU-film experiments showed that acetone was slightly better than hexane, and maceration better than sonication. When applied to PICC-lines, the extraction methods were almost similar but acetone was clearly better than hexane for TPU. From the 48 peaks initially observed in GC-MS, we ended up with 37 peaks to follow in TPU PICC-lines, among which were those of BHT and 4,4'-Methylenebis(cyclohexyl isocyanate) isomers. For silicone PICC-lines, out of 41 peaks initially observed in GC-MS, we followed 20 peaks, most of them being identified as cyclosiloxanes. Barium was the main inorganic element extracted for both PICC-lines. For TPU PICC-lines, the inter-batch variability was higher than for intra-batch, but in silicone devices both were similar. When compared to new PICC-lines, explanted TPU PICC-lines extracted peaks had a lower area under the curve (AUC), while the AUCs of the peaks were higher for the majority of silicone PICC-lines extract compounds. No identified substances were detected above their toxicological threshold, but isocyanates and cyclosiloxanes toxicity was mostly studied for other exposition routes than intravenous. The methods defined in this study were efficient in producing extractable profiles from both PICC-lines.

2.
J Visc Surg ; 161(2S): 25-31, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38272757

RESUMEN

INTRODUCTION: The objective of this systematic review of the literature is to compare a selection of currently utilized disposable and reusable laparoscopic medical devices in terms of safety (1st criteria), cost and carbon footprint. MATERIAL AND METHODS: A search was carried out on electronic databases for articles published up until 6 May 2022. The eligible works were prospective (randomized or not) or retrospective clinical or medical-economic comparative studies having compared disposable scissors, trocars, and mechanical endoscopic staplers to the same instruments in reusable. Two different independent examiners extracted the relevant data. RESULTS: Among the 2882 articles found, 156 abstracts were retained for examination. After comprehensive analysis concerning the safety and effectiveness of the instruments, we included four articles. A study on trocars highlighted increased vascular complications with disposable instruments, and another study found more perioperative incidents with a hybrid stapler as opposed to a disposable stapler. As regards cost analysis, we included 11 studies, all of which showed significantly higher costs with disposable instruments. The results of the one study on carbon footprints showed that hybrid instruments leave four times less of a carbon footprint than disposable instruments. CONCLUSION: The literature on the theme remains extremely limited. Our review demonstrated that from a medical and economic standpoint, reusable medical instruments, particularly trocars, presented appreciable advantages. While there exist few data on the ecological impact, those that do exist are unmistakably favorable to reusable instruments.


Asunto(s)
Huella de Carbono , Equipos Desechables , Equipo Reutilizado , Laparoscopía , Equipos Desechables/economía , Humanos , Equipo Reutilizado/economía , Laparoscopía/economía , Laparoscopía/instrumentación
3.
Pharm Res ; 41(1): 51-62, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37989952

RESUMEN

INTRODUCTION: Medical syringes are widely used in hospitals to store and administer drugs, and the contact time between the drugs and these syringes can vary from a few minutes to several weeks like for pharmaceutical preparations. The aim of this comparative study was to evaluate the potential sorption phenomena occurring between three drugs (paracetamol, diazepam and insulin aspart) and polypropylene syringes (PP) or syringes made of Cyclic Olefin Copolymer (COC). MATERIALS AND METHODS: 50 mL 3-part syringes made of either COC with crosslinked silicone on the barrel inner surface (COC-CLS) and a bromobutyl plunger seal, or PP lubricated with silicone oil (PP-SOL) with a polyisoprene plunger seal were used. RESULTS: COC-CLS syringes induced less sorption of diazepam and insulin than PP-SOL syringes and the plunger seal material seemed to be the main cause of these interactions. An alkalinization of the medications in contact with the PP-SOL syringes was observed. It could be caused by leachable compounds and should be investigated further. CONCLUSION: This work shows once again that it is essential to consider content-container interactions to help improve the safe use of parenteral drugs.


Asunto(s)
Cicloparafinas , Polipropilenos , Jeringas , Polímeros , Aceites de Silicona , Preparaciones Farmacéuticas , Diazepam
4.
Anaesth Crit Care Pain Med ; 42(5): 101291, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37562688

RESUMEN

OBJECTIVE: To provide guidelines for reducing the environmental impact of general anaesthesia. DESIGN: A committee of ten experts from SFAR and SF2H and SFPC learned societies was set up. A policy of declaration of competing interests was applied and observed throughout the guideline-writing process. Likewise, it did not benefit from any funding from a company marketing a health product (drug or medical device). The committee followed the GRADE® method (Grading of Recommendations Assessment, Development and Evaluation) to assess the quality of the evidence on which the recommendations were based. METHODS: We aimed to formulate recommendations according to the GRADE® methodology for three different fields: anaesthesia vapours and gases; intravenous drugs; medical devices and the working environment. Each question was formulated according to the PICO format (Population, Intervention, Comparator, Outcome). The literature review and recommendations were formulated according to the GRADE® methodology. RESULTS: The experts' work on the synthesis and application of the GRADE® method led to the formulation of 17 recommendations. Since the GRADE® method could not be entirely applied to all of the questions, some of the recommendations were formulated as expert opinions. CONCLUSION: Based on strong agreement between experts, we produced 17 recommendations designed to guide reducing the environmental impact of general anaesthesia.


Asunto(s)
Anestesia General , Anestesiología , Humanos , Anestesia General/efectos adversos , Ambiente
5.
Int J Pharm ; 643: 123254, 2023 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-37473975

RESUMEN

Medical devices (MD) are often made of plasticized polyvinylchloride (PVC). However, plasticizers may leach out into infused solutions and expose the patients to a toxic risk. The aim of the present work is to fluorinate plasticized PVC tubular MDs to create a barrier layer on their internal surface, and to study the impact of such a chemical treatment on the migration of the plasticizers. Following fluorination by pure molecular fluorine, the physico-chemical characterization of these modified MDs was carried out using various spectroscopic and microscopic techniques or tensile tests, evidencing the formation of covalent C-F bonds on the surface of the treated samples without modification of their mechanical and optical properties. The migration of plasticizers from fluorinated MDs was assessed using gas chromatography coupled with mass spectrometry and was found considerably decreased in comparison with the pristine MDs. After 24 h, the amount of tri-octyltrimellitate plasticizer (TOTM) detected in migrates from fluorinated MDs was even lower than the limit of quantification. Complementary cytotoxicity assays were performed according to the ISO EN 10993-5 standard, showing that the new fluorinated material does not cause a cytotoxic effect on L929 cells.


Asunto(s)
Dietilhexil Ftalato , Plastificantes , Humanos , Plastificantes/química , Halogenación , Cromatografía de Gases y Espectrometría de Masas/métodos , Cloruro de Polivinilo/química , Espectrometría de Masas , Dietilhexil Ftalato/toxicidad , Dietilhexil Ftalato/análisis , Dietilhexil Ftalato/química
6.
Pharmaceutics ; 15(3)2023 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-36986615

RESUMEN

Pentobarbital is a drug of choice to limit motion in children during paediatric procedural sedations (PPSs). However, despite the rectal route being preferred for infants and children, no pentobarbital suppositories are marketed, and therefore they must be prepared by compounding pharmacies. In this study, two suppository formulations of 30, 40, 50, and 60 mg of pentobarbital sodium were developed using hard-fat Witepsol® W25 either alone (formulation F1) or with oleic acid (formulation F2). The two formulations were subjected to the following tests described in the European Pharmacopoeia: uniformity of dosage units, softening time, resistance to rupture, and disintegration time. The stability of both formulations was also investigated for 41 weeks of storage at 5 ± 3 °C using a stability-indicating liquid chromatography method to quantify pentobarbital sodium and research breakdown product (BP). Although both formulae were compliant to uniformity of dosage, the results were in favour of a faster disintegration of F2 compared to F1 (-63%). On the other hand, F1 was found to be stable after 41 weeks of storage unlike F2 for which several new peaks were detected during the chromatographic analysis, suggesting a shorter stability of only 28 weeks. Both formulae still need to be clinically investigated to confirm their safety and efficiency for PPS.

7.
Front Public Health ; 11: 1125577, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36935690

RESUMEN

Nanomaterials are present in a wide variety of health products, drugs and medical devices and their use is constantly increasing, varying in terms of diversity and quantity. The topic is vast because it covers nanodrugs, but also excipients (that includes varying proportions of NMs) and medical devices (with intended or not-intended (by-products of wear) nanoparticles). Although researchers in the field of nanomedicines in clinical research and industry push for clearer definitions and relevant regulations, the endeavor is challenging due to the enormous diversity of NMs in use and their specific properties. In addition, regulatory hurdles and discrepancies are often cited as obstacles to the clinical development of these innovative products. The scientific council of the Agence Nationale de Sécurité du Médicament et des produits de santé (ANSM) undertook a multidisciplinary analysis encompassing fundamental, environmental and societal dimensions with the aim of identifying topics of interest for regulatory assessment and surveillance. This analysis allowed for proposing some recommendations for approximation and harmonization of international regulatory practices for the assessment of the risk/benefit balance of these products, considering as well the public expectations as regards efficacy and safety of nanomaterials used in Health products, in terms of human and environmental health.


Asunto(s)
Industrias , Salud Pública , Humanos
8.
Sci Total Environ ; 858(Pt 3): 159994, 2023 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-36368381

RESUMEN

Phthalates and other plasticisers are extensively used in medical devices (MD) from which they can leach out and lead to potential multiple problems for the patients. This exposure is a major issue because it is associated with reproductive and neurodevelopment disorders. The Neonatal Intensive Care Units (NICU) population is at high risk due to the daily intensive medical interventions, the reduced ability of newborns to remove these contaminants and their higher sensitivity to endocrine disruptors. We conducted a multicentric biomonitoring study to assess and compare the urinary levels of DEHP (di-(2-ethylhexyl)phthalate), DEHTP (di-(2-ethylhexyl)terephthalate) and TEHTM (tri-(2-ethylhexyl)trimellitate) metabolites as biomarkers of this exposure during and after the newborns' stay in NICU. Daily urinary samples were collected in NICU and at discharge from the hospital for each patient. MD sources and exposure factors were also investigated. 508 urinary samples from 97 patients enrolled in centres 1 and 2 (C1/C2) were collected. The exposure of newborns to DEHP was greater than that of DEHTP and TEHTM, with a median concentration of DEHP metabolites (C1:195.63 ng/mL;C2:450.87 ng/mL) respectively 5 to 10 times higher and 57 to 228 times higher than the median concentrations of DEHTP and TEHTM metabolites. The urinary concentrations of DEHP and TEHTM metabolites were significantly lower at discharge than in NICU, with a 18-and 35-fold decrease for DEHP and a 4 and 8-fold decrease for TEHTM, respectively for C1 and C2, but were similar for DEHTP metabolites. MD used for respiratory assistance, infusion therapy,enteral nutrition and transfusion were the main sources of exposure. Smaller gestational age and body weight significantly increased the newborns' exposure. The elevated levels of DEHP metabolites in NICU patients are still alarming. Additional efforts are necessary to promote its substitution in MD by possibly safer alternatives such as TEHTM and DEHTP, particularly when used for the care of newborns.


Asunto(s)
Disruptores Endocrinos , Unidades de Cuidado Intensivo Neonatal , Ácidos Ftálicos , Plastificantes , Humanos , Recién Nacido , Ácidos Ftálicos/análisis , Plastificantes/análisis , Exposición a Riesgos Ambientales , Disruptores Endocrinos/análisis , Biomarcadores/orina , Dietilhexil Ftalato/orina
9.
Sci Rep ; 12(1): 8959, 2022 05 27.
Artículo en Inglés | MEDLINE | ID: mdl-35624232

RESUMEN

Stability studies are essential to be able to assign an expiration date to medications. Color variation is one of the organoleptic characteristics of actives substances or medications which can indicate the presence of contaminations, impurities or degradations products. However there is no data available comparing the often used visual examination with spectrophotometric measurements during stability studies. The aim of this study was therefore to evaluate precisely how different the two methods are, by comparing the change of color of two drug formulations chosen as models, assessed by visual examination versus a spectrophotometric colorimetric analysis. Paracetamol and parenteral nutrition solutions were stored in stress conditions for up to 46 days, and were subjected to a visual examination using color reference solutions and to lightness and chromaticity measurement to determine their specific color by UV-Vis spectrophotometry. The color of paracetamol solutions changed faster when exposed to stress condition (light), as did the PNS when exposed to heat. In both cases, color variations were detected earlier and more precisely by UV-Vis spectrophotometry than by visual examination. Color measurement using an UV-Vis spectrophotometry should advantageously replace visual examination when assessing colors changes during drug stability studies.


Asunto(s)
Acetaminofén , Estabilidad de Medicamentos , Color , Colorimetría , Espectrofotometría
10.
ACS Appl Bio Mater ; 5(6): 2567-2575, 2022 06 20.
Artículo en Inglés | MEDLINE | ID: mdl-35549028

RESUMEN

We investigate the adsorption of insulin onto PE and PVC materials by using HPLC measurements and computer simulations. We interpret the experiments by calculating the Gibbs free energy profiles during the adsorption process. The values of free energy of adsorption show a good agreement with the experimental measurements. The adsorption of insulin onto the different materials is characterized through the conformational changes with respect to its conformation in water and the interfacial regions, which are described by specific arrangements of polymer chains, water, insulin, and plasticizer molecules.


Asunto(s)
Insulina , Cloruro de Polivinilo , Adsorción , Insulina Regular Humana , Plastificantes , Agua
11.
Front Bioeng Biotechnol ; 10: 818201, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35419353

RESUMEN

There is a growing body of evidences that brain surrogates will be of great interest for researchers and physicians in the medical field. They are currently mainly used for education and training purposes or to verify the appropriate functionality of medical devices. Depending on the purpose, a variety of materials have been used with specific and accurate mechanical and biophysical properties, More recently they have been used to assess the biocompatibility of implantable devices, but they are still not validated to study the migration of leaching components from devices. This minireview shows the large diversity of approaches and uses of brain phantoms, which converge punctually. All these phantoms are complementary to numeric models, which benefit, reciprocally, of their respective advances. It also suggests avenues of research for the analysis of leaching components from implantable devices.

12.
Toxics ; 10(2)2022 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-35202265

RESUMEN

BACKGROUND: The treatment of relapsed or refractory leukemia remains a major problem. Among the new therapeutic approaches, the use of modified T lymphocytes, called chimeric antigen receptor T cells (CAR-T cells), seems promising. The first step of their preparation is leukapheresis, which involves the collection of mononuclear cells from the patient. This medical procedure requires numerous medical devices (MDs) made of plasticized polyvinylchloride (PVC). These compounds can leach out of the devices during contact with the patient's blood. The aim of our study was to evaluate the migration of the plasticizers contained in the MD during a simulated pre-CAR-T cell leukapheresis procedure, and to measure the patient's and their lymphocytes' exposure to them. METHODS: The qualitative and quantitative composition of the MD used for pre-CAR-T cell apheresis was determined by gas chromatography-mass spectrometry (GC-MS). Then, an ex vivo leukapheresis model using an ethanol/water simulant was performed to evaluate the plasticizers' migration under simulated clinical conditions of pre-CAR-T cells' cytapheresis. The plasticizers released into the simulant were quantified by GC-MS. RESULTS: Diethylhexylphthalate (DEHP) was found in the apheresis kit, with amounts ranging from 25% to 59% (g/100 g of PVC). Bis(2-ethylhexyl) adipate was detected at trace levels. A total of 98.90 ± 11.42 mg of DEHP was released into the simulant, corresponding to an exposure dose of 1.4 mg/kg for a 70 kg patient. CONCLUSIONS: Patients undergoing a pre-CAR-T cell apheresis are mainly exposed to DEHP, which can impact their health because of its endocrine disruption effect, but could also lead to a decrease in CAR-T cells' efficiency/quality.

13.
Pharmaceutics ; 14(1)2022 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-35057013

RESUMEN

Tacrolimus is an immunosuppressant used to treat a large variety of inflammatory or immunity-mediated ophthalmic diseases. However, there are currently no commercial industrial forms available that can provide relief to patients. Various ophthalmic formulations have been reported in the literature, but their stability has only been tested over short periods. The objective of this study was to evaluate the physicochemical stability of a preservative-free tacrolimus formulation (0.2 and 1 mg/mL) at three storage temperatures (5 °C, 25 °C and 35 °C) for up to nine months in a multidose eyedropper. Analyses performed were the following: visual inspection and chromaticity, turbidity, viscosity, size of micelles, osmolality and pH measurements, tacrolimus quantification by a stability-indicating liquid chromatography method, breakdown product research, and sterility assay. In an in-use study, tacrolimus quantification was also performed on the drops emitted from the eyedroppers. All tested parameters remained stable during the nine month period when the eyedrops were stored at 5 °C. However, during storage at 25 °C and 35 °C, several signs of chemical instability were detected. Furthermore, a leachable compound originating from a silicone part of the eyedropper was detected during the in-use assay. Overall, the 0.2 mg/mL and 1 mg/mL tacrolimus ophthalmic solutions were physicochemically stable for up to nine months when stored at 5 °C.

14.
Arch Toxicol ; 96(3): 899-918, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35089383

RESUMEN

Tri-(2-ethylhexyl) trimellitate (TEHTM) is a plasticizer for polyvinyl chloride (PVC) material used in medical devices. It is an alternative to di-(2-ethylhexyl) phthalate (DEHP), a well-known reprotoxic and endocrine disruptor. As plasticizers are known to easily migrate when in contact with fatty biological fluids, patient exposure to TEHTM is highly probable. However, there is currently no data on the potential endocrine-disrupting effects of its human metabolites. To evaluate the effects of TEHTM metabolites on endocrine activity, they were first synthesized and their effects on estrogen, androgen and thyroid receptors, as well as steroid synthesis, were investigated by combining in vitro and in silico approaches. Among the primary metabolites, only 4-MEHTM (4-mono-(2-ethylhexyl) trimellitate) showed agonist activities on ERs and TRs, while three diesters were TR antagonists at non-cytotoxic concentrations. These results were completed by docking experiments which specified the ER and TR isoforms involved. A mixture of 2/1-MEHTM significantly increased the estradiol level and reduced the testosterone level in H295R cell culture supernatants. The oxidized secondary metabolites of TEHTM had no effect on ER, AR, TR receptors or on steroid hormone synthesis. Among the fourteen metabolites, these data showed that two of them (4-MEHTM and 2/1-MEHTM) induced effect on hormonal activities in vitro. However, by comparing the concentrations of the primary metabolites found in human urine with the active concentrations determined in bioassays, it can be suggested that the metabolites will not be active with regard to estrogen, androgen, thyroid receptors and steroidogenesis-mediated effects.


Asunto(s)
Benzoatos/toxicidad , Disruptores Endocrinos/toxicidad , Plastificantes/toxicidad , Benzoatos/metabolismo , Línea Celular Tumoral , Simulación por Computador , Disruptores Endocrinos/metabolismo , Estradiol/metabolismo , Humanos , Simulación del Acoplamiento Molecular , Plastificantes/metabolismo , Receptores Androgénicos/efectos de los fármacos , Receptores Androgénicos/metabolismo , Receptores de Estrógenos/efectos de los fármacos , Receptores de Estrógenos/metabolismo , Receptores de Hormona Tiroidea/efectos de los fármacos , Receptores de Hormona Tiroidea/metabolismo , Testosterona/metabolismo
15.
Int J Mol Sci ; 22(19)2021 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-34638878

RESUMEN

Ceftazidime (CZ) and vancomycin (VA) are two antibiotics used to treat bacterial keratitis. Due to their physical incompatibility (formation of a precipitate), it is not currently possible to associate both molecules in a single container for ophthalmic administration. We firstly characterized the incompatibility then investigated if 2-hydroxypropyl-beta (HPßCD) and 2-hydroxypropyl-gamma cyclodextrins (HPγCD) could prevent this incompatibility. The impact of pH on the precipitation phenomena was investigated by analysing the supernatant solution of the mixture using high performance liquid chromatography. A characterization of the inclusion of CZ with HPγCD using 1H nuclear magnetic resonance (NMR), and VA with HPßCD using 1H-NMR and a solubility diagram was performed. A design of experiment was built to determine the optimal conditions to obtain a formulation that had the lowest turbidity and particle count. Our results showed that VA and CZ form an equimolar precipitate below pH 7.3. The best formulation obtained underwent an in-vitro evaluation of its antibacterial activity. The impact of HPCDs on incompatibility has been demonstrated through the inclusion of antibiotics and especially VA. The formulation has been shown to be able to inhibit the incompatibility for pH higher than 7.3 and to possess unaltered antibacterial activity.


Asunto(s)
Antibacterianos/química , Ceftazidima/química , Composición de Medicamentos , Infecciones Bacterianas del Ojo/tratamiento farmacológico , Queratitis/tratamiento farmacológico , Vancomicina/química , gamma-Ciclodextrinas/química , Antibacterianos/farmacología , Ceftazidima/farmacología , Humanos , Queratitis/microbiología , Vancomicina/farmacología
16.
Pharmaceutics ; 13(10)2021 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-34684002

RESUMEN

Silicone and polyurethane are biocompatible materials used for the manufacture of implantable catheters, but are known to induce drug loss by sorption, causing potentially important clinical consequences. Despite this, their impact on the drugs infused through them is rarely studied, or they are studied individually and not part of a complete infusion setup. The aim of this work was to experimentally investigate the drug loss that these devices can cause, on their own and within a complete infusion setup. Paracetamol, diazepam, and insulin were chosen as models to assess drug sorption. Four commonly used silicone and polyurethane catheters were studied independently and as part of two different setups composed of a syringe, an extension set, and silicone or polyurethane implantable catheter. Simulated infusion through the catheter alone or through the complete setup were tested, at flowrates of 1 mL/h and 10 mL/h. Drug concentrations were monitored by liquid chromatography, and the silicone and polyurethane materials were characterized by ATR-IR spectroscopy and Zeta surface potential measurements. The losses observed with the complete setups followed the same trend as the losses induced individually by the most sorptive device of the setup. With the complete setups, no loss of paracetamol was observed, but diazepam and insulin maximum losses were respectively of 96.4 ± 0.9% and 54.0 ± 5.6%, when using a polyurethane catheter. Overall, catheters were shown to be the cause of some extremely high drug losses that could not be countered by optimizing the extension set in the setup.

18.
Front Bioeng Biotechnol ; 9: 657875, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34178958

RESUMEN

INTRODUCTION: Although deep brain stimulation is nowadays performed worldwide, the biomechanical aspects of electrode implantation received little attention, mainly as physicians focused on the medical aspects, such as the optimal indication of the surgical procedure, the positive and adverse effects, and the long-term follow-up. We aimed to describe electrode deformations and brain shift immediately after implantation, as it may highlight our comprehension of intracranial and intracerebral mechanics. MATERIALS AND METHODS: Sixty electrodes of 30 patients suffering from severe symptoms of Parkinson's disease and essential tremor were studied. They consisted of 30 non-directional electrodes and 30 directional electrodes, implanted 42 times in the subthalamus and 18 times in the ventrolateral thalamus. We computed the x (transversal), y (anteroposterior), z (depth), torsion, and curvature deformations, along the electrodes from the entrance point in the braincase. The electrodes were modelized from the immediate postoperative CT scan using automatic voxel thresholding segmentation, manual subtraction of artifacts, and automatic skeletonization. The deformation parameters were computed from the curve of electrodes using a third-order polynomial regression. We studied these deformations according to the type of electrodes, the clinical parameters, the surgical-related accuracy, the brain shift, the hemisphere and three tissue layers, the gyration layer, the white matter stem layer, and the deep brain layer (type I error set at 5%). RESULTS: We found that the implanted first hemisphere coupled to the brain shift and the stiffness of the type of electrode impacted on the electrode deformations. The deformations were also different according to the tissue layers, to the electrode type, and to the first-hemisphere-brain-shift effect. CONCLUSION: Our findings provide information on the intracranial and brain biomechanics and should help further developments on intracerebral electrode design and surgical issues.

19.
Metabolites ; 11(4)2021 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-33921860

RESUMEN

Care management of newborns in the neonatal intensive care unit (NICU) requires numerous PVC (PolyVinyl Chloride) medical devices (MD) containing plasticizers that can migrate and contaminate the patient. We measured the magnitude of neonates' exposure to plasticizers (di-ethylhexylphthalate (DEHP) and alternatives) in relation to urinary concentrations of their metabolites. Plasticizers' exposure was evaluated (1) by calculating the amounts of plasticizers prone to be released from each MD used for care management, and (2) by measuring the patients' urinary levels of each plasticizers' metabolites. 104 neonates were enrolled. They were exposed to di-isononylphthalate (DINP), especially via transfusion and infusion MD, and to DEHP via ECMO (Extra Corporeal Membrane Oxygenation) and respiratory assistance MD. Mean exposure doses exceeded the derived no-effect level of DINP and DEHP by a 10-fold and a 1000-fold factor. No PVC MD were plasticized with di-isononylcyclohexane-1,2-dicarboxylate (DINCH). High urinary concentrations of DEHP metabolites were directly correlated with DEHP exposure through ECMO MD. Urinary concentrations of DINP metabolites in transfused patients were also high. DINCH metabolites were found in urine, suggesting another route of exposure. Neonates in NICU are considerably exposed to plasticizers, with magnitudes varying with the type of MD used. The high exposure to DEHP and DINP leads to a risk of their metabolites' toxicity.

20.
ACS Appl Mater Interfaces ; 13(16): 18594-18603, 2021 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-33861563

RESUMEN

Characterizing the sorption of drugs onto polyvinylchloride (PVC) and polyethylene (PE) materials in terms of thermodynamic adsorption properties and atomistic details (local arrangements, orientation, and diffusion) is fundamental for the development of alternative materials that would limit drug sorption phenomena and plasticizer release. Here, a combination of experiments and sophisticated calculations of potential of mean forces are carried out to investigate the sorption of paracetamol and diazepam to PE and PVC surfaces. The simulated Gibbs free energies of adsorption are in line with the experimental interpretations. The polymer-drug-water interface is then characterized at the molecular scale by an in-depth investigation of local properties such as density, orientation, and diffusion.


Asunto(s)
Polietileno/química , Cloruro de Polivinilo/química , Acetaminofén/química , Diazepam/química , Difusión , Propiedades de Superficie , Termodinámica , Agua/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...