Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
AJNR Am J Neuroradiol ; 43(2): 251-257, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-35027348

RESUMEN

BACKGROUND AND PURPOSE: Aspiration thrombectomy has become a preferred approach to recanalize large-vessel occlusion in stroke with a growing trend toward using larger-bore catheters and stronger vacuum pumps. However, the mechanical response of the delicate cerebral arteries to aspiration force has not been evaluated. Here, we provide preclinical and clinical evidence of intracranial arterial collapse in aspiration thrombectomy. MATERIALS AND METHODS: We presented a clinical case of arterial collapse with previously implanted flow diverters. We then evaluated the effect of vacuum with conventional aspiration catheters (with and without stent retrievers) in a rabbit model (n = 3) using fluoroscopy and intravascular optical coherence tomography. Then, in a validated human cadaveric brain model, we conducted 168 tests of direct aspiration thrombectomy following an experimental design modifying the catheter inner diameter (0.064 inch, 0.068 inch, and 0.070 inch), cerebral perfusion pressures (mean around 60 and 90 mm Hg), and anterior-versus-posterior circulation. Arterial wall response was recorded and graded via direct transluminal observation. RESULTS: Arterial collapse was observed in both the patient and preclinical experimental models. In the human brain model, arterial collapse was observed in 98% of cases in the M2 and in all the cases with complete proximal flow arrest. A larger bore size of the aspiration catheter, a lower cerebral perfusion pressure, and the posterior circulation in comparison with the anterior circulation were associated with a higher probability of arterial collapse. CONCLUSIONS: Arterial collapse does occur during aspiration thrombectomy and is more likely to happen with larger catheters, lower perfusion pressure, and smaller arteries.


Asunto(s)
Accidente Cerebrovascular , Trombectomía , Animales , Encéfalo/diagnóstico por imagen , Encéfalo/cirugía , Catéteres , Arterias Cerebrales/diagnóstico por imagen , Arterias Cerebrales/cirugía , Humanos , Conejos , Stents , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/cirugía , Trombectomía/métodos , Resultado del Tratamiento
2.
AJNR Am J Neuroradiol ; 43(4): 517-525, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35086801

RESUMEN

CSF-venous fistula is a relatively novel entity that is increasingly being recognized as a cause for spontaneous intracranial hypotension. Recently, our group published the first series of transvenous embolization of CSF-venous fistulas in this journal. Having now performed the procedure in 60 patients, we have garnered increasing familiarity with the anatomy and how to navigate our way through the venous system to any intervertebral foramen in the cervical, thoracic, and lumbar spine. The first part of this review summarizes the organization of spinal venous drainage as described in classic anatomy and interventional radiology texts, the same works that we studied when attempting our first cases. In the second part, we draw mostly on our own experience to provide a practical roadmap from the puncture site to the foramen. On the basis of these 2 parts, we hope this article will serve to collate the relevant anatomic knowledge and give confidence to colleagues who wish to embark on transvenous spinal procedures.


Asunto(s)
Embolización Terapéutica , Hipotensión Intracraneal , Drenaje/efectos adversos , Embolización Terapéutica/efectos adversos , Humanos , Hipotensión Intracraneal/etiología , Punción Espinal/efectos adversos , Columna Vertebral
3.
AJNR Am J Neuroradiol ; 43(2): 258-264, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34916206

RESUMEN

Endovascular treatment of aneurysms with flow diverters or coiling is sometimes complicated by intraprocedural or postprocedural thrombosis along or within the devices. Thrombus composition and structure associated with such complications may provide insights into mechanisms of thrombus formation and clinical strategies to remove the thrombus. We present a retrospective histopathologic study of 4 patients who underwent mechanical thrombectomy due to acute occlusion of either implanted flow diverter devices or along coils during the treatment of intracranial aneurysm.


Asunto(s)
Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Trombosis , Embolización Terapéutica/efectos adversos , Procedimientos Endovasculares/efectos adversos , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Estudios Retrospectivos , Stents/efectos adversos , Trombosis/diagnóstico por imagen , Trombosis/etiología , Resultado del Tratamiento
4.
AJNR Am J Neuroradiol ; 42(11): 1968-1972, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34556479

RESUMEN

BACKGROUND AND PURPOSE: The persistent challenges in thrombectomy for large-vessel occlusion, such as suboptimal complete recanalization and first-pass effect imply an insufficient understanding of the artery-clot-device interaction. In this study, we present a thrombectomy model using fresh human brains, which can capture the artery-clot-device interaction through concurrent transmural and angiographic visualizations. MATERIALS AND METHODS: Fresh nonfrozen whole adult human brains were collected and connected to a customized pump system tuned to deliver saline flow at a physiologic flow rate and pressure. Angiography was performed to verify the flow in the anterior-posterior and vertebrobasilar circulations and collaterals. Large-vessel occlusion was simulated by embolizing a radiopaque clot analog. Thrombectomy was tested, and the artery-clot-device interactions were recorded by transmural and angiographic videos. RESULTS: Baseline cerebral angiography revealed excellent penetration of contrast in the anterior-posterior and vertebrobasilar circulations without notable arterial cutoffs and with robust collaterals. Small branches (<0.5 mm) and perforating arteries were consistently opacified with good patency. Three device passes were performed to achieve recanalization, with failure modes including elongation, fragmentation, and distal embolization. CONCLUSIONS: This model enables concurrent transmural and angiographic analysis of artery-clot-device interaction in a human brain and provides critical insights into the action mechanism and failure modes of current and upcoming thrombectomy devices.


Asunto(s)
Embolización Terapéutica , Accidente Cerebrovascular , Trombosis , Encéfalo/diagnóstico por imagen , Encéfalo/cirugía , Humanos , Accidente Cerebrovascular/terapia , Trombectomía , Resultado del Tratamiento
5.
AJNR Am J Neuroradiol ; 42(7): 1239-1249, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-34255735

RESUMEN

BACKGROUND AND PURPOSE: Hydrophilic polymers and polytetrafluoroethylene liners, commonly used in the construction of endovascular devices, occasionally separate from devices with subsequent embolization. We determined the frequency of such materials in thrombus specimens retrieved by mechanical thrombectomy in patients with stroke. MATERIALS AND METHODS: We retrospectively reviewed H&E-stained thrombus sections for presence and types of foreign materials. We identified 4 types of foreign materials-Type I: material was light green with refraction and had a homogeneous texture; type II: material was light gray and/or dark gray, thin, and loose or attenuated in texture; type III: material was light green with refraction, solitary in texture, irregular in shape, and was often associated with round or oval bubblelike particles and/or diffuse black particles; and type IV: material had homogeneous texture and was light pink or red. In addition, polymer materials from different layers of used mechanical thrombectomy catheters were compared with the foreign materials found in thrombus specimens. RESULTS: A total of 101 thrombi were evaluated. Foreign materials were found in 53 (52.5%) thrombus samples. The most common type was type I (92%), followed by type II (30%). The histopathologic features of the polymer materials from mechanical thrombectomy catheters were similar to the foreign materials found in thrombus specimens. The inner polytetrafluoroethylene liner and coating layer of catheters resembled type I and type II of the foreign materials, respectively. CONCLUSIONS: Foreign polymer materials are present in approximately half of retrieved thrombi, most commonly polytetrafluoroethylene from catheter liners and less from hydrophilic coatings.


Asunto(s)
Cuerpos Extraños , Accidente Cerebrovascular , Trombectomía , Trombosis , Materiales Biocompatibles , Cuerpos Extraños/patología , Humanos , Enfermedad Iatrogénica , Polímeros , Estudios Retrospectivos , Accidente Cerebrovascular/cirugía , Trombectomía/instrumentación , Trombosis/patología
6.
AJNR Am J Neuroradiol ; 42(5): 882-887, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33541895

RESUMEN

We report a consecutive case series of patients who underwent transvenous embolization of the paraspinal vein, which was draining the CSF-venous fistula, for treatment of spontaneous intracranial hypotension. These are the first-ever reported cases of this treatment for CSF-venous fistulas. All patients underwent spinal venography following catheterization of the azygous vein and then selective catheterization of the paraspinal vein followed by embolization of the vein with Onyx. All patients had improvement of clinical and radiologic findings with 4 patients having complete resolution of headaches and 1 patient having 50% reduction in headache symptoms. Pachymeningeal enhancement resolved in 4 patients and improved but did not resolve in 1 patient. Brain sag resolved in 4 patients and improved but did not resolve in 1 patient. There were no cases of permanent neurologic complications. All patients were discharged home on the day of the procedure.


Asunto(s)
Venas Cerebrales , Presión del Líquido Cefalorraquídeo , Embolización Terapéutica/métodos , Fístula/diagnóstico por imagen , Hipotensión Intracraneal/diagnóstico por imagen , Adulto , Anciano , Dimetilsulfóxido , Embolización Terapéutica/efectos adversos , Femenino , Fístula/complicaciones , Fístula/terapia , Cefalea/etiología , Cefalea/terapia , Humanos , Hipotensión Intracraneal/etiología , Hipotensión Intracraneal/terapia , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Polivinilos , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA