Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Arch Cardiovasc Dis ; 117(4): 249-254, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38494400

RESUMEN

BACKGROUND: Pulsed field ablation has recently emerged as an interesting non-thermal energy for atrial fibrillation ablation. At a time of rapid spread of this technology, there is still a lack of prospective real-life data. AIM: To describe multicentre prospective safety and 1-year efficacy data in three of the first French centres to use pulsed field ablation. METHODS: All consecutive patients undergoing a first pulsed field ablation were included prospectively. The primary outcome was freedom from documented atrial arrhythmia. The safety endpoint was a composite of major adverse events. Univariate and multivariable analyses, including patient and procedural characteristics, were performed to identify factors predictive of recurrence. RESULTS: Between May 2021 and June 2022, 311 patients were included (paroxysmal atrial fibrillation in 53%, persistent atrial fibrillation in 35% and long-standing persistent atrial fibrillation in 11%). Additional non-pulmonary vein pulsed field ablation applications were performed in 104/311 patients. One-year freedom from arrhythmia recurrence was 77.6% in the overall population and was significantly higher in patients with paroxysmal atrial fibrillation (88.4%) compared with patients with persistent atrial fibrillation (69.7%; P<0.001) and those with long-standing persistent atrial fibrillation (49.0%; P<0.001). The major complication rate was 2.6% (tamponade in four patients, stroke in two patients and coronary spasm in one patient). Besides the usual predictors of recurrences (left atrium size, CHA2DS2-VASc score, type of atrial fibrillation), the presence of atrial fibrillation at procedure start was independently associated with arrhythmia recurrence (hazard ratio: 2.04, 95% confidence interval: 1.10-3.77). CONCLUSION: In this prospective multicentre real-world study, pulsed field ablation for atrial fibrillation ablation seems to be associated with a good safety profile and rather favourable acute and 1-year success rates.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Estudios Prospectivos , Resultado del Tratamiento , Catéteres , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
2.
J Am Heart Assoc ; 13(6): e033146, 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38471838

RESUMEN

BACKGROUND: Cryoballoon ablation is currently the gold standard technique for single-shot pulmonary vein isolation (PVI). Pulsed field ablation (PFA) has recently emerged as an interesting nonthermal alternative energy for PVI. The purpose of our study was to evaluate the safety and long-term efficacy of PVI using the pentaspline PFA catheter in comparison to cryoballoon ablation. METHODS AND RESULTS: Between January 2021 and December 2022, we included all consecutive patients of our center in whom a first PVI-only procedure was performed using PFA or cryoballoon. The choice of the energy was based on patients' preference between general anesthesia (PFA) and local anesthesia (cryoballoon). The primary end point was freedom from documented atrial arrhythmia recurrence after a 3-month blanking period. A total of 301 patients (paroxysmal atrial fibrillation in 220 patients) underwent a first PVI procedure performed using PFA (n=151) or cryoballoon (n=150). Complete short-term PVI was obtained in 144 of 150 patients (96%) in the cryoballoon group and in all patients of the PFA group (P=0.01). Procedure duration was significantly longer in the cryoballoon group. Transient and persistent phrenic nerve injuries were observed in the cryoballoon group only (13/150 and 2/150, respectively). One-year freedom from atrial arrhythmia was significantly higher in the PFA group compared with the cryoballoon group (87.9% versus 77.7%; adjusted hazard ratio, 0.53 [95% CI, 0.30-0.96]; P=0.037). CONCLUSIONS: This prospective, comparative, real-life study suggested that PFA could overcome safety limitations of cryoballoon with optimal effectiveness. Randomized controlled studies are required to further investigate the potential superiority of PFA over cryoballoon.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Estudios Prospectivos , Resultado del Tratamiento , Criocirugía/efectos adversos , Criocirugía/métodos , Catéteres , Venas Pulmonares/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
3.
Eur J Neurosci ; 57(11): 1892-1912, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37066486

RESUMEN

Cardiac arrest survivors develop a variety of neuropsychological impairments and neuroanatomical lesions. The goal of this study is to evaluate if brain voxel-based morphometry and lesional Magnetic Resonance Imaging (MRI) analyses performed in the acute phase of an Out-of-Hospital Cardiac Arrest (OHCA) can be sensitive enough to predict the persistence of neuropsychological disorders beyond 3 months. Survivors underwent a prospective brain MRI during the first month after an OHCA and performed neuropsychological assessments at 1 and 3 months. According to the second neuropsychological assessment, survivors were separated into two subgroups, a deficit subgroup with persistent memory, executive functions, attention and/or praxis disorders (n = 11) and a preserved subgroup, disorders free (n = 14). Brain vascular lesion images were investigated, and volumetric changes were compared with healthy controls. Correlations were discussed between brain MRI results, OHCA data and the second neuropsychological assessment. Analyses of acute ischemic lesions did not reveal significant differences between the two subgroups (p = .35), and correlations with cognitive impairments could not be assessed. voxel-based morphometry analyses revealed a global cerebral volume reduction for the two subgroups and a clear decrease of the right thalamic volume for the deficit subgroup. It was associated with a cognitive dysexecutive syndrome represented by four executive indexes according to the 'Groupe de Réflexion pour l'Evaluation des Fonctions EXécutives' criteria. The right thalamus atrophy seems to be more predictive than the vascular lesions and more specific than a global cerebral volume reduction of post-OHCA neuropsychological executive disorders.


Asunto(s)
Disfunción Cognitiva , Paro Cardíaco Extrahospitalario , Humanos , Paro Cardíaco Extrahospitalario/diagnóstico por imagen , Paro Cardíaco Extrahospitalario/complicaciones , Paro Cardíaco Extrahospitalario/patología , Estudios Prospectivos , Disfunción Cognitiva/diagnóstico por imagen , Disfunción Cognitiva/etiología , Pruebas Neuropsicológicas , Imagen por Resonancia Magnética , Tálamo/diagnóstico por imagen , Tálamo/patología , Cognición
4.
Front Cardiovasc Med ; 10: 1132503, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37020516

RESUMEN

CD19-specific chimeric antigen receptor T (CAR-T) cell therapy has recently been shown to improve the prognosis of refractory diffuse large B-cell lymphoma (DLBCL). However, CAR-T cells may induce numerous adverse events, in particular cytokine release syndrome (CRS) which is frequently associated with cardiovascular manifestations. Among the latter, acute pericardial effusion represents less than 1% of cases and cardiac tamponade has only been reported once. The management and outcome of these severe complications are not well established. We report here, a case of cardiac tamponade associated with CRS in a context of CAR-T cell therapy, which required urgent pericardiocentesis. Case summary: A 65-year-old man with refractory DLBCL was treated with CAR-T cell therapy. He had a history of dilated cardiomyopathy with preserved ejection fraction and transient atrial fibrillation. A pericardial localization of the lymphoma was observed on the second relapse. One day after CAR-T cell infusion the patient was diagnosed with grade 1 CRS. Due to hypotension, he was treated with tocilizumab and dexamethasone, and then transferred to intensive care unit (ICU). Echocardiography performed at ICU admission showed acute pericardial effusion with signs of right ventricular heart failure due to cardiac tamponade. It was decided to perform pericardiocentesis despite grade IV thrombocytopenia in a context of aplasia. Analysis of pericardial fluid showed a large number of lymphoma cells and 73% of CAR-T cells amongst lymphocytes, a level that was similar in blood. Hemodynamic status improved after pericardiocentesis, and no recurrence of pericardial effusion was observed. The presence of a high count of activated CAR-T cells in the pericardial fluid as well as the short interval between CAR-T cells injection and the symptoms appear as potential arguments for a direct action of CAR-T cells in the mechanism of this adverse event. The patient was discharged from ICU after two days and initially exhibited a good response to DLBCL treatment. Unfortunately, he died fifty days after starting CAR-T cell therapy due to a new DLBCL relapse. Conclusion: Patients with a pericardial localization of DLBCL should be assessed for a risk of cardiac tamponade if receiving CAR-T cell therapy and presenting CRS. In this case, cardiac tamponade seems directly related to CAR-T cell expansion. Pericardiocentesis should be considered as a feasible and effective treatment if the risk of bleeding is well controlled, in association with anti-IL6 and corticosteroids.

5.
ESC Heart Fail ; 10(3): 2120-2126, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36940720

RESUMEN

AIMS: There are currently limited therapeutic approaches for patients with heart failure with preserved ejection fraction (HFpEF) who have developed permanent atrial fibrillation (AF). We aimed to analyse the impact of ventricular irregularity on heart failure rehospitalization in patients with permanent AF and HFpEF. METHODS AND RESULTS: All 24 h ambulatory Holter monitoring performed in our centre within a month after a first heart failure hospitalization were screened. Patients with HFpEF and permanent AF were included in the retrospective analysis. The following parameters of ventricular irregularity were calculated over the 24 h recording period: standard deviation of all RR intervals (SDNN), coefficient of variation of SDNN (CV-SDNN = SDNN/mean RR), root of the mean squared differences of successive RR intervals (RMSSD), and percentage of consecutive RR intervals with difference over 50 ms (pNN50). The primary endpoint was rehospitalization for acute heart failure (HFrH). From 2010 to 2021, 51/216 screened patients were included. During a median follow-up of 3.13 years, 29/51 patients reached the primary endpoint. HFrH patients had higher SDNN (205 ± 65 vs. 154 ± 46 ms; P < 0.01), CV-SDNN (26 ± 8% vs. 19 ± 5%, P < 0.01), RMSSD (182 ± 47 vs. 138 ± 65 ms, P = 0.013), and pNN50 (76 ± 9 vs. 58 ± 26, P < 0.001) when compared with patients with no HFrH. In multivariate analysis, all those parameters remained significantly associated with HFrH. CONCLUSIONS: In this pilot study, we found some evidences for a deleterious impact of excessive ventricular irregularity on HFrH in AF patients with HFpEF. Those new findings could pave the way for new prognosis and therapeutic approaches in this patients' population.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/terapia , Fibrilación Atrial/epidemiología , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/terapia , Volumen Sistólico , Readmisión del Paciente , Frecuencia Cardíaca , Estudios Retrospectivos , Proyectos Piloto
6.
Arch Cardiovasc Dis ; 116(2): 62-68, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36604192

RESUMEN

BACKGROUND: Catheter ablation is a first-line treatment for symptomatic right ventricular outflow tract (RVOT) premature ventricular complexes (PVCs). There is evidence of displacement of the ablation target site during PVCs relative to the location in sinus rhythm (SR). AIM: To analyse the extent of displacement induced by RVOT PVCs and its effect on the ablation sites and the mid-term efficacy of ablation. METHODS: In this multicentre French study, we retrospectively included 18 consecutive adults referred for ablation of RVOT PVCs using a three-dimensional (3D) mapping system. PVC activation maps were performed conventionally (initial map), then each PVC activation point was manually reannotated considering the 3D location on a previous SR beat (corrected map). The ablation-site locations on the initial or the corrected area, including the 10 best activation points, were analysed. Mid-term efficacy was evaluated. RESULTS: The direction of map shift during PVCs relative to the map in SR occurred along a vertical axis in 16 of 18 patients. The mean activation-point displacement for each of the 18 mapped chambers was 5.6±2.2mm. Mid-term recurrence of RVOT PVCs occurred in 5 (28%) patients. In all patients with recurrences, no significant ablation lesion was located on the corrected (true) site of origin. CONCLUSIONS: RVOT PVCs induce a vertical anatomical shift that can mislead physicians about the true location of the arrhythmia's site of origin. Our study highlights the association between mid-term PVC recurrence and the absence of spatial overlap between ablation points and the corrected site of origin.


Asunto(s)
Ablación por Catéter , Complejos Prematuros Ventriculares , Adulto , Humanos , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/etiología , Complejos Prematuros Ventriculares/cirugía , Estudios Retrospectivos , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Resultado del Tratamiento
7.
Europace ; 25(2): 526-535, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36480437

RESUMEN

AIMS: Left bundle branch area pacing (LBBAP) is a recent technique aiming at preservation of physiological ventricular electrical activation. Our goal was to assess mechanical synchrony parameters in relation to electrocardiographic features during LBBAP performed in routine practice. METHODS AND RESULTS: From June 2020 to August 2021, all patients of our institution with permanent pacemaker implantation indication were eligible for LBBAP. A 'qR' pattern in V1 and a delay from pacing spike to the peak of the R-wave in V6 < 80 ms defined a successful LBBAP. Electrocardiogram and echocardiography were performed during spontaneous rhythm and LBBAP: left ventricular mechanical synchrony (LVMS) parameters using 2D Speckle tracking and interventricular mechanical delay (IVMD) were collected. LBBAP was attempted with success in 134/163 patients (82.2%). During LBBAP, the mean QRS width was 104 ± 12 ms. In patients with left bundle branch block (n = 47), LBBAP provided a significant decrease of QRS width from 139 ± 16 to 105 ± 12 ms (P < 0.001) with reduction of LVMS (53 ± 21 vs. 90 ± 46 ms, P = 0.009), and IVMD (14 ± 13 vs. 49 ± 18 ms, P < 0.001). In patients with right bundle branch block (n = 38), LBBAP led to a significant decrease of QRS width from 134 ± 14 to 106 ± 13 ms (P < 0.001) with no effect on LVMS and a reduction of IVMD (17 ± 14 vs. 50 ± 16 ms, P < 0.001). CONCLUSION: LBBAP in routine practice preserved intra-ventricular mechanical synchrony in patients with narrow and RBBB QRS and improved asynchrony parameters in patients with LBBB.


Asunto(s)
Bloqueo de Rama , Estimulación Cardíaca Artificial , Humanos , Bloqueo de Rama/diagnóstico por imagen , Bloqueo de Rama/terapia , Estimulación Cardíaca Artificial/métodos , Sistema de Conducción Cardíaco , Electrocardiografía/métodos , Ecocardiografía/métodos , Arritmias Cardíacas , Fascículo Atrioventricular
8.
Heart Rhythm ; 20(4): 530-536, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36549630

RESUMEN

BACKGROUND: His-bundle pacing (HBP) is an appealing alternative to right ventricular pacing in patients referred for permanent ventricular pacing and atrioventricular nodal ablation (AVNA) because it preserves physiological ventricular activation. Only limited data regarding HBP combined with AVNA are available in the literature. OBJECTIVE: The purpose of this study was to provide further evidence on the feasibility and efficacy of this therapeutic approach in patients with uncontrolled atrial arrhythmia. METHODS: We prospectively included all patients who had undergone AVNA after HBP in 3 different hospitals between 2017 and 2022. RESULTS: AVNA following HBP lead implantation was performed in 75 patients. Complete atrioventricular (AV) block was obtained in 58 patients (77%), and significant modulation of AV nodal conduction (heart rate <60 bpm) was obtained in 12 patients (16%). AVNA failure was observed in 5 patients (7%). Recording of an atrial signal by the HBP lead was more frequently observed in patients with AVNA modulation/failure than in patients with complete AV block (11/17 vs 5/58; P <.001). No lead dislodgment occurred during the AVNA procedures. Acute His-bundle (HB) capture threshold increase >1 V occurred in 11 patients (15%), with return to baseline value on day 1 in 9 patients. New York Heart Association functional class and left ventricular ejection fraction significantly improved from baseline to last follow-up (3.0 ± 0.7 vs 1.6 ± 0.5; P <.001; and 47% ± 14% vs 60% ± 9%; P <.0001, respectively). CONCLUSION: AVNA combined with HBP for noncontrolled atrial arrhythmia was feasible and clinically efficient. Implanting the HB lead on the ventricular aspect of the tricuspid annulus avoiding atrial signal recording can facilitate AVNA.


Asunto(s)
Fibrilación Atrial , Bloqueo Atrioventricular , Humanos , Fibrilación Atrial/cirugía , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda , Estimulación Cardíaca Artificial/métodos , Fascículo Atrioventricular
9.
Europace ; 24(8): 1256-1266, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-35647644

RESUMEN

AIMS: Pulsed field ablation (PFA) is a novel atrial fibrillation (AF) ablation modality that has demonstrated preferential tissue ablation, including no oesophageal damage, in first-in-human clinical trials. In the MANIFEST-PF survey, we investigated the 'real world' performance of the only approved PFA catheter, including acute effectiveness and safety-in particular, rare oesophageal effects and other unforeseen PFA-related complications. METHODS AND RESULTS: This retrospective survey included all 24 clinical centres using the pentaspline PFA catheter after regulatory approval. Institution-level data were obtained on patient characteristics, procedure parameters, acute efficacy, and adverse events. With an average of 73 patients treated per centre (range 7-291), full cohort included 1758 patients: mean age 61.6 years (range 19-92), female 34%, first-time ablation 94%, paroxysmal/persistent AF 58/35%. Most procedures employed deep sedation without intubation (82.1%), and 15.1% were discharged same day. Pulmonary vein isolation (PVI) was successful in 99.9% (range 98.9-100%). Procedure time was 65 min (38-215). There were no oesophageal complications or phrenic nerve injuries persisting past hospital discharge. Major complications (1.6%) were pericardial tamponade (0.97%) and stroke (0.4%); one stroke resulted in death (0.06%). Minor complications (3.9%) were primarily vascular (3.3%), but also included transient phrenic nerve paresis (0.46%), and TIA (0.11%). Rare complications included coronary artery spasm, haemoptysis, and dry cough persistent for 6 weeks (0.06% each). CONCLUSION: In a large cohort of unselected patients, PFA was efficacious for PVI, and expressed a safety profile consistent with preferential tissue ablation. However, the frequency of 'generic' catheter complications (tamponade, stroke) underscores the need for improvement.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Accidente Cerebrovascular , Adulto , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Femenino , Humanos , Persona de Mediana Edad , Venas Pulmonares/cirugía , Estudios Retrospectivos , Accidente Cerebrovascular/etiología , Resultado del Tratamiento , Adulto Joven
10.
Heart ; 108(21): 1729-1736, 2022 10 13.
Artículo en Inglés | MEDLINE | ID: mdl-35641178

RESUMEN

AIMS: Purpose of this study is to compare the clinical course and outcome of patients with recurrent versus first-episode infective endocarditis (IE). METHODS: Patients with recurrent and first-episode IE enrolled in the EUROpean ENDOcarditis (EURO-ENDO) registry including 156 centres were identified and compared using propensity score matching. Recurrent IE was classified as relapse when IE occurred ≤6 months after a previous episode or reinfection when IE occurred >6 months after the prior episode. RESULTS: 3106 patients were enrolled: 2839 (91.4%) patients with first-episode IE (mean age 59.4 (±18.1); 68.3% male) and 267 (8.6%) patients with recurrent IE (mean age 58.1 (±17.7); 74.9% male). Among patients with recurrent IE, 13.2% were intravenous drug users (IVDUs), 66.4% had a repaired or replaced valve with the tricuspid valve being more frequently involved compared with patients with first-episode IE (20.3% vs 14.1%; p=0.012). In patients with a first episode of IE, the aortic valve was more frequently involved (45.6% vs 39.5%; p=0.061). Recurrent relapse and reinfection were 20.6% and 79.4%, respectively. Staphylococcus aureus was the microorganism most frequently observed in both groups (p=0.207). There were no differences in in-hospital and post-hospitalisation mortality between recurrent and first-episode IE. In patients with recurrent IE, in-hospital mortality was higher in IVDU patients. Independent predictors of poorer in-hospital and 1-year outcome, including the occurrence of cardiogenic and septic shock, valvular disease severity and failure to undertake surgery when indicated, were similar for recurrent and first-episode IE. CONCLUSIONS: In-hospital and 1-year mortality was similar in patients with recurrent and first-episode IE who shared similar predictors of poor outcome.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Infecciones Estafilocócicas , Endocarditis/diagnóstico , Endocarditis/cirugía , Endocarditis Bacteriana/diagnóstico , Endocarditis Bacteriana/cirugía , Femenino , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Reinfección , Estudios Retrospectivos , Infecciones Estafilocócicas/diagnóstico , Infecciones Estafilocócicas/cirugía
11.
J Arrhythm ; 37(5): 1303-1310, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34621429

RESUMEN

BACKGROUND: Although less common, typical atrial flutter shares similar pathophysiological roots with atrial fibrillation. Following successful cavo-tricuspid isthmus ablation using radiofrequency, many patients, however, develop atrial fibrillation in the mid-to-long-term. This study sought to assess whether pulmonary vein isolation conducted at the same time as cavo-tricuspid isthmus ablation would significantly modify the atrial fibrillation burden upon follow-up in patients suffering from typical atrial flutter. METHODS: This was a multicenter randomized controlled study involving typical atrial flutter patients with history of non-predominant atrial fibrillation (1 atrial fibrillation episode only, in 67% of population) who were scheduled for cavo-tricuspid isthmus radiofrequency ablation. Patients were randomly assigned to either undergo cavo-tricuspid isthmus ablation alone or cavo-tricuspid isthmus plus pulmonary vein isolation (CTI+). Pulmonary vein isolation was performed using cryoballoon technology. An outpatient consultation with ECG and 1-week Holter monitoring was performed at 3, 6 months, 1 year, and 2 years postprocedure. The primary endpoint was atrial fibrillation recurrences lasting more than 30 s at 2 years postablation. RESULTS: Of the patients enrolled, 36 were included in each group. At 2-year follow-up, the atrial fibrillation recurrence rate was significantly higher in the CTI vs CTI+group (25/36, 69% vs. 12/36, 33% respectively; P < .001), with similar typical atrial flutter recurrence rates. There were no differences in undesirable events, except for transient phrenic nerve palsy reported from three CTI+patients (8.3%). CONCLUSION: Pulmonary vein isolation using cryoballoon technology was proven to significantly reduce the atrial fibrillation incidence at 2 years postcavo-tricuspid isthmus ablation.

12.
Semin Arthritis Rheum ; 51(6): 1274-1281, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34465446

RESUMEN

BACKGROUND: Native joint and bone infections (NJBI) are associated with infective endocarditis (IE) in 15% of cases. There are no studies analyzing the use of cardiac imaging in cases of NJBI. The objective of this study was to identify factors associated with echocardiography suggestive of IE in patients with NJBI. METHODS: This medical records review was conducted in patients hospitalized for NJBI between 2007 and 2017 in Rheumatology and Infectious Diseases departments of 2 university hospitals. Patients included had a microbiologically proven NJBI during their hospitalization. RESULTS: In this cohort of 546 patients, median age 66 years, echocardiography was suggestive of IE in 66 (12%). In multivariate analysis, factors associated with echocardiography suggestive of IE were 2 or more positive blood cultures (OR 11.55 (CI95% 3.24-74.20)), cardiac conditions with a high risk of IE (OR 7.34 (CI95% 2.95-18.61)), unknown heart murmur (OR 4.59 (CI95% 1.79-11.74)), multifocal infection (OR 2.26 (CI95% 1.21-4.23)) and an infection due to S. bovis (OR 3.52 (CI95% 1.26-9.79)). The factor associated with the absence of an echocardiography evocative of IE was infection due to unconventional bacteria for IE (OR 0.13 (CI95% 0.01-0.76)). According to the factors associated with echocardiography evocative of IE, we propose the Normandy score based on three kinds of data: cardiac condition, bacterial strain and NJBI mechanism. Echocardiography should be realized when this score, whose negative predictive value is 100% CI95% (98-100%) for prescription of echocardiography, is more than zero. CONCLUSIONS: A score based on valvular condition, bacterial strain and NJBI mechanism could guide clinicians in prescribing echocardiography during NJBI with an excellent negative predictive value.


Asunto(s)
Artritis Infecciosa , Endocarditis Bacteriana , Anciano , Artritis Infecciosa/complicaciones , Estudios de Cohortes , Ecocardiografía/métodos , Endocarditis Bacteriana/complicaciones , Humanos , Estudios Retrospectivos , Factores de Riesgo
13.
Europace ; 23(11): 1860-1866, 2021 11 08.
Artículo en Inglés | MEDLINE | ID: mdl-33975338

RESUMEN

AIMS: Although cryoenergy safety profile is appropriate for the ablation of arrhythmogenic foci near the conduction system, mapping using the cryoablation catheter is of limited precision. Combining the safety of cryoenergy and the high precision of a 3D mapping system therefore appears the most appropriate set-up for ablation in the vicinity of the His bundle. METHODS AND RESULTS: A 29-year-old woman with a 3-year history of increasing shortness of breath and palpitations refractory to medical treatment was sent to the electrophysiology (EP) laboratory for catheter ablation. Surface electrocardiogram showed sinus rhythm and frequent ectopic beats with narrow QRS complexes similar to those of the sinus beats. The left ventricular ejection fraction was impaired (38%) with no other aetiology found, apart from frequent ectopies. Detailed intracardiac mapping, using a 3D electroanatomical system, revealed that the ectopy originated from the distal His bundle, which was indicated by both antegrade and reversed His bundle activation sequence during ectopy compared to that during sinus rhythm. Due to the proximity of the conduction system, cryoenergy rather than radiofrequency was chosen to target this Hisian ectopy. A special set-up was made in order to allow the cryoablation catheter to be visualized into the 3D mapping system. Cryoenergy delivered to the site of earliest Hisian ectopy activation completely abolished it. CONCLUSION: Such a combined approach may help to improve the therapeutic strategy for ablation procedures with a high risk of injury to the conduction system. It could notably be extended to the ablation of para-Hisian ectopy or accessory pathways.


Asunto(s)
Fascículo Atrioventricular Accesorio , Ablación por Catéter , Adulto , Fascículo Atrioventricular/cirugía , Ablación por Catéter/métodos , Electrocardiografía , Femenino , Humanos , Volumen Sistólico , Taquicardia , Función Ventricular Izquierda
14.
J Cardiovasc Electrophysiol ; 32(2): 417-427, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33373093

RESUMEN

BACKGROUND: Right ventricular pacing (RVP) induces ventricular asynchrony in patients with normal QRS and increases the risk of heart failure and atrial fibrillation in long term. His bundle pacing (HBP) is a physiological alternative to RVP, and could overcome its drawbacks. Recent studies assessed the feasibility and safety of HBP in expert centers with a vast experience of this technique. These results may not apply to less experienced centers. We aim to evaluate the feasibility and safety of permanent HBP performed by physicians who are new to this technique. METHODS: We included all patients who underwent pacemaker implantation with attempt of HBP in three hospitals between September 2017 and January 2020. Indication for HBP was left to operators' discretion. All the operators were new for HBP. His bundle (HB) electrical parameters were recorded at implant, 3- and 12-month follow-up. RESULTS: HBP was successful in 141 of 170 patients (82.9%); selective HBP was obtained in 96 patients and nonselective HBP in 45. The mean procedure and fluoroscopy durations were 67.0 ± 28.8 min, and 7.3 ± 8.1 min (3.1 ± 4.1 Gy·cm2 ), respectively. The mean HB paced QRS duration was 106 ± 18 ms. The mean HB capture threshold was 1.29 ± 0.77 V and did not increase at 3- and 12-month follow-up. The ventricular lead revision was required in five patients. Our results showed a rapid technical learning allowing a high procedure success rate (89.8%) after 15 procedures. CONCLUSION: HBP performed by operators new to this technique appeared feasible and safe. This should encourage HBP to be performed in patients expected to experience high RVP burden.


Asunto(s)
Fibrilación Atrial , Fascículo Atrioventricular , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Estimulación Cardíaca Artificial , Electrocardiografía , Humanos , Sistema de Registros , Resultado del Tratamiento
15.
Arch Cardiovasc Dis ; 114(2): 105-114, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33129697

RESUMEN

BACKGROUND: Cryoballoon ablation is an effective procedure to treat atrial fibrillation (AF). However, AF recurrence rate at 1-year follow-up is approximately 20% despite improvements in ablation technique. AIM: To find factors predictive of AF recurrence following a first pulmonary vein isolation procedure using a second-generation cryoballoon (PVI-2CB). METHODS: This was an observational, retrospective, single-centre study. From June 2012 to April 2017, all patients who had a PVI-2CB procedure and a scheduled follow-up at Rouen University Hospital were included. The primary endpoint was atrial arrhythmia (AA) recurrence (e.g. AF, flutter or tachycardia), considering a blanking period of 2 months following the procedure. Secondary endpoints were procedural variables for each pulmonary vein (successful isolation, time to disconnection, total cryoballoon application time, number of cryoballoon applications, level of occlusion during cryoballoon application leading to successful disconnection and lowest temperature reached during successful cryoballoon application), occurrence of redo procedures, use of antiarrhythmic drugs and adverse events. RESULTS: The initial population consisted of 239 patients; six were excluded for lack of procedural variable data, giving an analysed population of 233 patients. The AA recurrence rate was 36.9% (mean follow-up 25±14 months). Mean time to AA recurrence was 10±12 months. No procedural variable was found to be predictive of AA recurrence. Only major left atrial enlargement (defined as diameter>50mm or left atrial area>30cm2 or left atrial volume>50mL/m2) was predictive (odds ratio 2.70, 95% confidence interval 1.54-4.72; P=0.001). Forty-one patients had redo procedures (17.6% of analysed population); in this subgroup, 75.6% had at least one pulmonary vein reconnected, mainly the right inferior pulmonary vein. CONCLUSIONS: At long-term follow-up, up to one-third of patients had AA recurrence after PVI-2CB. Important atrial remodelling was the only factor predictive of AA recurrence, whereas no procedural variable was found to be predictive.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía/efectos adversos , Venas Pulmonares/cirugía , Potenciales de Acción , Anciano , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Aleteo Atrial/etiología , Aleteo Atrial/cirugía , Femenino , Francia , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/fisiopatología , Recurrencia , Reoperación , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Taquicardia Supraventricular/etiología , Taquicardia Supraventricular/cirugía , Factores de Tiempo , Resultado del Tratamiento
16.
J Cardiovasc Electrophysiol ; 31(12): 3215-3222, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33079433

RESUMEN

INTRODUCTION: Either cryoenergy or radiofrequency can be used during atrioventricular nodal reentrant tachycardia (AVNRT) ablation. There are still limited data comparing their respective long-term efficacy (>1 year). This study sought to compare the very long-term outcomes of AVNRT ablation using radiofrequency or cryotherapy. METHODS: We retrospectively included all patients who had undergone a first AVNRT ablation in our institution between January 2010 and December 2017. The primary endpoint was recurrence of documented AVNRT. RESULTS: The study population consisted of 409 patients (274 females; mean age, 49.9 years). Ablation was performed using cryoenergy in 260 patients and radiofrequency in 149. High acute procedural success rate (>98%) was obtained and no permanent AV block was observed using both techniques. During a mean follow-up of 3.3 ± 2.3 years, documented AVNRT recurrence occurred in 24 (9.2%) and 4 patients (2.7%) in the cryoablation (CA) and radiofrequency (RF) group, respectively. The risk of AVNRT recurrence was significantly higher in the CA group as compared with the RF group (hazard ratio [HR] = 3.7; 95% confidence interval [CI], 1.3-5.9). Most of the recurrences after CA occurred between 1- and 6-year follow-up (14/24; 58.3%), with one-third of late recurrences after 3-year follow-up. In multivariable analysis, only Koch's triangle anatomical variant was associated with AVNRT recurrence after CA (HR = 6.7; 95% CI, 2.7-16.3). CONCLUSION: While AVNRT recurrence rates were similar at 1 year of follow-up regardless of the energy used, long-term efficacy appeared higher after radiofrequency ablation. Strikingly, recurrences occured much later after cryotherapy compared with radiofrequency ablation.


Asunto(s)
Ablación por Catéter , Criocirugía , Taquicardia por Reentrada en el Nodo Atrioventricular , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Femenino , Humanos , Persona de Mediana Edad , Recurrencia , Estudios Retrospectivos , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Resultado del Tratamiento
17.
J Cardiovasc Electrophysiol ; 31(9): 2344-2351, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32562446

RESUMEN

BACKGROUND: The coronary sinus (CS) is surrounded by a myocardial coat with extensive connections to the left and right atria that contributes to the interatrial electrical connection. Whereas epicardial connections between CS musculature and the left atrium have largely been demonstrated, clinically relevant epicardial connections from the CS musculature toward the low right atrium (LRA) and epicardial connections between two regions of the right atrium remain questionable. METHODS: Five patients underwent electrophysiology (EP) study for typical atrial flutter (AFl) using either conventional multipolar catheters (four patients) or three-dimensional high-density mapping system (one patient). RESULTS: All five patients had a similar sequence of events during the EP studies. After several cavotricuspid isthmus (CTI) radiofrequency (RF) applications, double potentials were recorded along the ablation line while tachycardia persisted. The right atrial activation pattern strongly suggested the presence of a complete endocardial CTI line of the block. Based on the detailed conventional atrial mapping, RF applications at the middle cardiac vein/CS ostium allowed sinus rhythm restoration in four patients. High-density mapping showed an early breakthrough site at the septal side of the ablation line, close to the CS ostium during counterclockwise AFl, in the fifth patient. RF applications at this site resulted in tachycardia termination. CONCLUSION: Our observations suggested the existence of epicardial fibers connecting the LRA with either the CS musculature or a remote right atrial region. When AFl ablation fails whereas evidence for the local endocardial block is observed, the operators should integrate this finding in the diagnosis and ablation strategy.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Seno Coronario , Aleteo Atrial/diagnóstico por imagen , Aleteo Atrial/cirugía , Seno Coronario/diagnóstico por imagen , Seno Coronario/cirugía , Técnicas Electroquímicas , Endocardio , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Humanos
18.
JACC Clin Electrophysiol ; 5(8): 944-954, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31439296

RESUMEN

OBJECTIVES: This study aimed to evaluate incidence, clinical significance, and predictors of early ventricular arrhythmias (VAs) in left ventricular assist device (LVAD) recipients. BACKGROUND: LVAD implantation is increasingly used in patients with end-stage heart failure. Early VAs may occur during the 30-day post-operative period, but many questions remain unanswered regarding their incidence and clinical impact. METHODS: This observational study was conducted in 19 centers between 2006 and 2016. Early VAs were defined as sustained ventricular tachycardia and/or ventricular fibrillation occurring <30 days post-LVAD implantation and requiring appropriate implantable cardioverter-defibrillator therapy, external electrical shock, or medical therapy. RESULTS: A total of 652 patients (median age: 59.8 years; left ventricular ejection fraction: 20.7 ± 7.4%; HeartMate 2: 72.8%; HeartWare: 19.5%; Jarvik 2000: 7.7%) were included in the analysis. Early VAs occurred in 162 patients (24.8%), most frequently during the first week after LVAD implantation. Multivariable analysis identified history of VAs prior to LVAD and any combined surgery with LVAD as 2 predictors of early VAs. The occurrence of early VAs with electrical storm was the strongest predictor of 30-day post-operative mortality, associated with a 7-fold increase of 30-day mortality. However, in patients discharged alive from hospital, occurrence of early VAs did not influence long-term survival. CONCLUSIONS: Early VAs are common after LVAD implantation and increase 30-day post-operative mortality, without affecting long-term survival. Further studies will be needed to analyze whether pre- or pre-operative ablation of VAs may improve post-operative outcomes. (Determination of Risk Factors of Ventricular Arrhythmias After Implantation of Continuous Flow Left Ventricular Assist Device With Continuous Flow Left Ventricular Assist Device [ASSIST-ICD]; NCT02873169).


Asunto(s)
Arritmias Cardíacas , Ventrículos Cardíacos/fisiopatología , Corazón Auxiliar , Complicaciones Posoperatorias , Anciano , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/mortalidad , Femenino , Insuficiencia Cardíaca/terapia , Corazón Auxiliar/efectos adversos , Corazón Auxiliar/estadística & datos numéricos , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/mortalidad , Estudios Retrospectivos
19.
Am Heart J ; 214: 69-76, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31174053

RESUMEN

BACKGROUND: Left ventricular assist device (LVAD)-associated infections may be life-threatening and impact patients' outcome. We aimed to identify the characteristics, risk factors, and prognosis of LVAD-associated infections. METHODS: Patients included in the ASSIST-ICD study (19 centers) were enrolled. The main outcome was the occurrence of LVAD-associated infection (driveline infection, pocket infection, or pump/cannula infection) during follow-up. RESULTS: Of the 652 patients enrolled, 201 (30.1%) presented a total of 248 LVAD infections diagnosed 6.5 months after implantation, including 171 (26.2%), 51 (7.8%), and 26 (4.0%) percutaneous driveline infection, pocket infection, or pump/cannula infection, respectively. Patients with infections were aged 58.7 years, and most received HeartMate II (82.1%) or HeartWare (13.4%). Most patients (62%) had implantable cardioverter-defibrillators (ICDs) before LVAD, and 104 (16.0%) had ICD implantation, extraction, or replacement after the LVAD surgery. Main pathogens found among the 248 infections were Staphylococcus aureus (n = 113' 45.4%), Enterobacteriaceae (n = 61; 24.6%), Pseudomonas aeruginosa (n = 34; 13.7%), coagulase-negative staphylococci (n = 13; 5.2%), and Candida species (n = 13; 5.2%). In multivariable analysis, HeartMate II (subhazard ratio, 1.56; 95% CI, 1.03 to 2.36; P = .031) and ICD-related procedures post-LVAD (subhazard ratio, 1.43; 95% CI, 1.03-1.98; P = .031) were significantly associated with LVAD infections. Infections had no detrimental impact on survival. CONCLUSIONS: Left ventricular assist device-associated infections affect one-third of LVAD recipients, mostly related to skin pathogens and gram-negative bacilli, with increased risk with HeartMate II as compared with HeartWare, and in patients who required ICD-related procedures post-LVAD. This is a plea to better select patients needing ICD implantation/replacement after LVAD implantation.


Asunto(s)
Infecciones Relacionadas con Catéteres/etiología , Corazón Auxiliar/efectos adversos , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Catéteres/epidemiología , Infecciones Relacionadas con Catéteres/microbiología , Infecciones Relacionadas con Catéteres/mortalidad , Desfibriladores Implantables/estadística & datos numéricos , Remoción de Dispositivos/estadística & datos numéricos , Femenino , Francia/epidemiología , Ventrículos Cardíacos , Corazón Auxiliar/estadística & datos numéricos , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Pronóstico , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/mortalidad , Estudios Retrospectivos , Factores de Riesgo
20.
Neurocase ; 25(1-2): 34-38, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31020910

RESUMEN

The delay between cardiac arrest and brain MRI is usually extremely different in the few cerebral imaging studies assessing the affected brain areas. We report an unusual case of loss of psychic self-activation appeared immediately after a cardiac arrest in a middle age patient. The first brain MRI, one month after the vascular event, did not show the classical lesions typically reported, such as lesion of the caudate nucleus or the globus pallidus. Two years later, although the cognitive performances of our patient were improved, a second brain MRI demonstrated bilateral pallidal lesions, suggesting a possible mechanism with delayed hypoxic lesions.


Asunto(s)
Apatía , Trastornos del Conocimiento/etiología , Globo Pálido/patología , Paro Cardíaco Extrahospitalario/complicaciones , Globo Pálido/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...