Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Phys Rev Lett ; 130(2): 021801, 2023 Jan 13.
Artículo en Inglés | MEDLINE | ID: mdl-36706416

RESUMEN

We investigate the possible origins of the reactor antineutrino anomalies in norm and shape within the framework of a summation model where ß^{-} transitions are simulated by a phenomenological model of Gamow-Teller decay strength. The general trends of divergence from the Huber-Mueller model on the antineutrino side can be reproduced in both norm and shape. From the exact electron-antineutrino correspondence of the summation model, we predict similar distortions in the electron spectra, suggesting that biases on the reference spectra of fission electrons could be the cause of the anomalies.

2.
Phys Rev Lett ; 128(6): 061801, 2022 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-35213177

RESUMEN

Different extensions of the standard model of particle physics, such as braneworld or mirror matter models, predict the existence of a neutron sterile state, possibly as a dark matter candidate. This Letter reports a new experimental constraint on the probability p for neutron conversion into a hidden neutron, set by the STEREO experiment at the high flux reactor of the Institut Laue-Langevin. The limit is p<3.1×10^{-11} at 95% C.L. improving the previous limit by a factor of 13. This result demonstrates that short-baseline neutrino experiments can be used as competitive passing-through-walls neutron experiments to search for hidden neutrons.

3.
Phys Rev Lett ; 125(20): 201801, 2020 Nov 13.
Artículo en Inglés | MEDLINE | ID: mdl-33258621

RESUMEN

We report a measurement of the antineutrino rate from the fission of ^{235}U with the STEREO detector using 119 days of reactor turned on. In our analysis, we perform several detailed corrections and achieve the most precise single measurement at reactors with highly enriched ^{235}U fuel. We measure an IBD cross section per fission of σ_{f}=(6.34±0.06[stat]±0.15[sys]±0.15[model])×10^{-43} cm^{2}/fission and observe a rate deficit of (5.2±0.8[stat]±2.3[sys]±2.3[model])% compared to the model, consistent with the deficit of the world average. Testing ^{235}U as the sole source of the deficit, we find a tension between the results of lowly and highly enriched ^{235}U fuel of 2.1 standard deviations.

4.
Nanotechnology ; 20(41): 415303, 2009 Oct 14.
Artículo en Inglés | MEDLINE | ID: mdl-19762941

RESUMEN

A quantitative analysis of blurring and its dependence on the stencil-substrate gap and the deposition parameters in stencil lithography, a high resolution shadow mask technique, is presented. The blurring is manifested in two ways: first, the structure directly deposited on the substrate is larger than the stencil aperture due to geometrical factors, and second, a halo of material is formed surrounding the deposited structure, presumably due to surface diffusion. The blurring is studied as a function of the gap using dedicated stencils that allow a controlled variation of the gap. Our results show a linear relationship between the gap and the blurring of the directly deposited structure. In our configuration, with a material source of approximately 5 mm and a source-substrate distance of 1 m, we find that a gap size of approximately 10 microm enlarges the directly deposited structures by approximately 50 nm. The measured halo varies from 0.2 to 3 microm in width depending on the gap, the stencil aperture size and other deposition parameters. We also show that the blurring can be reduced by decreasing the nominal deposition thickness, the deposition rate and the substrate temperature.


Asunto(s)
Nanoestructuras/química , Nanotecnología/métodos , Nanocables/química , Microscopía Electrónica de Rastreo , Nanoestructuras/ultraestructura , Nanocables/ultraestructura
5.
Nano Lett ; 8(11): 3675-82, 2008 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-18817451

RESUMEN

Aluminum and gold nanowires were fabricated using 100 mm stencil wafers containing nanoslits fabricated with a focused ion beam. The stencils were aligned and the nanowires deposited on a substrate with predefined electrical pads. The morphology and resistivity of the wires were studied. Nanowires down to 70 nm wide and 5 mum long have been achieved showing a resistivity of 10 microOmegacm for Al and 5 microOmegacm for Au and maximum current density of approximately 10(8) A/cm(2). This proves the capability of stencil lithography for the fabrication of metallic nanowires on a full wafer scale.


Asunto(s)
Aluminio/química , Oro/química , Nanocables/química , Nanocables/ultraestructura , Microscopía de Fuerza Atómica , Silicio/química
6.
Phys Rev Lett ; 92(10): 102003, 2004 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-15089200

RESUMEN

We report on a new measurement of the parity-violating asymmetry in quasielastic electron scattering from the deuteron at backward angles at Q2=0.038 (GeV/c)2. This quantity provides a determination of the neutral weak axial vector form factor of the nucleon, which can potentially receive large electroweak corrections. The measured asymmetry A=-3.51+/-0.57 (stat)+/-0.58 (syst) ppm is consistent with theoretical predictions. We also report on updated results of the previous experiment at Q2=0.091 (GeV/c)2, which are also consistent with theoretical predictions.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA