Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Otol Neurotol ; 45(6): 635-642, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38769110

RESUMEN

OBJECTIVE: To investigate if cartilage conduction (CC) rerouting devices are noninferior to air-conduction (AC) rerouting devices for single-sided deafness (SSD) patients by measuring objective and subjective performance using speech-in-noise tests that resemble a realistic hearing environment, sound localization tests, and standardized questionnaires. STUDY DESIGN: Prospective, single-subject randomized, crossover study. SETTING: Anechoic room inside a university. PATIENTS: Nine adults between 21 and 58 years of age with severe or profound unilateral sensorineural hearing loss. INTERVENTIONS: Patients' baseline hearing was assessed; they then used both the cartilage conduction contralateral routing of signals device (CC-CROS) and an air-conduction CROS hearing aid (AC-CROS). Patients wore each device for 2 weeks in a randomly assigned order. MAIN OUTCOME MEASURES: Three main outcome measures were 1) speech-in-noise tests, measuring speech reception thresholds; 2) proportion of correct sound localization responses; and 3) scores on the questionnaires, "Abbreviated Profile of Hearing Aid Benefit" (APHAB) and "Speech, Spatial, and Qualities of Hearing Scale" with 12 questions (SSQ-12). RESULTS: Speech reception threshold improved significantly when noise was ambient, and speech was presented from the front or the poor-ear side with both CC-CROS and AC-CROS. When speech was delivered from the better-ear side, AC-CROS significantly improved performance, whereas CC-CROS had no significant effect. Both devices mainly worsened sound localization, whereas the APHAB and SSQ-12 scores showed benefits. CONCLUSION: CC-CROS has noninferior hearing-in-noise performance except when the speech was presented to the better ear under ambient noise. Subjective measures showed that the patients realized the effectiveness of both devices.


Asunto(s)
Conducción Ósea , Estudios Cruzados , Audífonos , Pérdida Auditiva Sensorineural , Localización de Sonidos , Percepción del Habla , Humanos , Adulto , Persona de Mediana Edad , Masculino , Femenino , Localización de Sonidos/fisiología , Conducción Ósea/fisiología , Pérdida Auditiva Sensorineural/fisiopatología , Pérdida Auditiva Sensorineural/rehabilitación , Percepción del Habla/fisiología , Encuestas y Cuestionarios , Estudios Prospectivos , Pérdida Auditiva Unilateral/fisiopatología , Pérdida Auditiva Unilateral/rehabilitación , Adulto Joven , Ruido , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...