Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
JACC Cardiovasc Interv ; 16(7): 783-794, 2023 04 10.
Artículo en Inglés | MEDLINE | ID: mdl-36898939

RESUMEN

BACKGROUND: Post-percutaneous coronary intervention (PCI) quantitative flow ratio (QFR) values ≥0.90 are associated with a low incidence of adverse events. OBJECTIVES: The AQVA (Angio-based Quantitative Flow Ratio Virtual PCI Versus Conventional Angio-guided PCI in the Achievement of an Optimal Post-PCI QFR) trial aims to test whether a QFR-based virtual percutaneous coronary intervention (PCI) is superior to a conventional angiography-based PCI at obtaining optimal post-PCI QFR results. METHODS: The AQVA trial is an investigator-initiated, randomized, controlled, parallel-group clinical trial. A total of 300 patients (356 study vessels) undergoing PCI were randomized 1:1 to receive either QFR-based virtual PCI or angiography-based PCI (standard of care). The primary outcome was the rate of study vessels with a suboptimal post-PCI QFR value, which was defined as <0.90. Secondary outcomes were procedure duration, stent length/lesion, and stent number/patient. RESULTS: Overall, 38 (10.7%) study vessels missed the prespecified optimal post-PCI QFR target. The primary outcome occurred significantly more frequently in the angiography-based group (n = 26, 15.1%) compared with the QFR-based virtual PCI group (n = 12 [6.6%]; absolute difference = 8.5%; relative difference = 57%; P = 0.009). The main cause of a suboptimal result in the angiography-based group is the underestimation of a diseased segment outside the stented one. There were no significant differences among secondary endpoints, although stent length/lesion and stent number/patient were numerically lower in the virtual PCI group (P = 0.06 and P = 0.08, respectively), whereas procedure length was higher in the virtual PCI group (P = 0.06). CONCLUSIONS: The AQVA trial demonstrated the superiority of QFR-based virtual PCI over angiography-based PCI with regard to post-PCI optimal physiological results. Future larger randomized clinical trials that demonstrate the superiority of this approach in terms of clinical outcomes are warranted. (Angio-based Quantitative Flow Ratio Virtual PCI Versus Conventional Angio-guided PCI in the Achievement of an Optimal Post-PCI QFR [AQVA]; NCT04664140).


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/etiología , Angiografía Coronaria/métodos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Vasos Coronarios/diagnóstico por imagen , Resultado del Tratamiento , Valor Predictivo de las Pruebas
2.
Int J Cardiovasc Imaging ; 38(12): 2819-2827, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36445673

RESUMEN

To test whether quantitative flow ratio (QFR)-based trans-stent gradient (TSG) is associated with adverse clinical events at follow-up. A post-hoc analysis of the multi-center HAWKEYE study was performed. Vessels post-PCI were divided into four groups (G) as follows: G1: QFR ≥ 0.90 TSG = 0 (n = 412, 54.8%); G2: QFR ≥ 0.90, TSG > 0 (n = 216, 28.7%); G3: QFR < 0.90, TSG = 0 (n = 37, 4.9%); G4: QFR < 0.90, TSG > 0 (n = 86, 11.4%). Cox proportional hazards regression model was used to analyze the effect of baseline and prognostic variables. The final reduced model was obtained by backward stepwise variable selection. Receiver operating characteristic (ROC) was plotted and area under the curve (AUC) was calculated and reported. Overall, 449 (59.8%) vessels had a TSG = 0 whereas (40.2%) had TSG > 0. Ten (2.2%) vessel-oriented composite endpoint (VOCE) occurred in vessels with TSG = 0, compared with 43 (14%) in vessels with TSG > 0 (p < 0.01). ROC analysis showed an AUC of 0.74 (95% CI: 0.67 to 0.80; p < 0.001). TSG > 0 was an independent predictor of the VOCE (HR 2.95 [95% CI 1.77-4.91]). The combination of higher TSG and lower final QFR (G4) showed the worst long-term outcome while low TSG and high QFR showed the best outcome (G1) while either high TSG or low QFR (G2, G3) showed intermediate and comparable outcomes. Higher trans-stent gradient was an independent predictor of adverse events and identified a subgroup of patients at higher risk for poor outcomes even when vessel QFR was optimal (> 0.90).


Asunto(s)
Intervención Coronaria Percutánea , Humanos , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Stents , Área Bajo la Curva , Curva ROC
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...