G Ital Cardiol (Rome) ; 23(2): 128-132, 2022 Feb.
Artículo en Italiano | MEDLINE | ID: mdl-35343517

RESUMEN

Rotational atherectomy represents an option to improve the treatment of calcified/undilatable coronary stenoses, but its use in ST-elevation myocardial infarction (STEMI) is controversial. We report the case of a patient with an occlusive and calcified coronary stenosis and its management not previously described. A 67-year-old man with STEMI was referred to our cath-lab. Coronary angiography showed a complex calcified and thrombotic occlusion of the right coronary artery. Vessel patency was obtained with balloon dilation, achieving clinical stability. The patient started dual antiplatelet therapy and was scheduled for a staged procedure using rotational atherectomy ("Rota-staged PCI"), performed 6 days later reaching optimal angiographic and clinical results. Our purpose was to manage this STEMI patient with an occluded and heavily calcified coronary artery in two times: a primary coronary angioplasty to quickly reopen the artery and an early staged PCI using rotational atherectomy to optimize the intervention (coronary dilation and stent deployment) minimizing the risk of stent underexpansion or acute complications.


Asunto(s)
Angioplastia Coronaria con Balón , Infarto de la Pared Anterior del Miocardio , Aterectomía Coronaria , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Anciano , Angioplastia Coronaria con Balón/métodos , Aterectomía Coronaria/métodos , Humanos , Masculino , Infarto del Miocardio con Elevación del ST/cirugía
2.
Am J Cardiol ; 124(10): 1518-1527, 2019 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-31547997

RESUMEN

Patients with diabetes mellitus (DM) have worse outcomes after percutaneous coronary intervention (PCI). Recent evidences suggest a differential impact of insulin-treated and noninsulin-treated DM on prognosis. We evaluated the clinical outcome of diabetic patients after PCI with polymer-free biolimus-eluting stent from the RUDI-FREE Registry, investigating a possible different prognostic impact of insulin-treated and noninsulin-treated DM. A total of 1,104 consecutive patients who underwent PCI with polymer-free biolimus-eluting stent, enrolled in the RUDI-FREE observational, multicenter, single-arm registry, were stratified by diabetic status; diabetic population was further divided on the basis of insulin treatment. Primary end points of the study were target lesion failure (TLF; composite of cardiac death, target vessel myocardial infarction, target lesion revascularization) and major adverse cardiac and cerebrovascular events (composite of cardiac death, stroke, and myocardial infarction). Multiple ischemic adverse events were also single-handedly considered as secondary end points. At 1 year, TLF was significantly higher in the diabetic cohort, as compared with nondiabetic patients (6.0% vs 3.1%, p 0.022). None of the end points resulted significantly different between nondiabetics and noninsulin-treated diabetic patients. Divergently, compared with nondiabetic, insulin-treated diabetic patients faced significant higher rates of TLF (10.8% vs 3.1%, p 0.003), major adverse cardiac and cerebrovascular events (10.8% vs 3.4%, p 0.004), and of most of the analyzed adverse events. In conclusion, patients with DM had a higher risk of TLF compared with nondiabetics; nonetheless, the worse outcome of the diabetic population seems to be driven by the insulin-treated diabetic subpopulation. This finding suggests a different risk profile of insulin-treated and noninsulin-treated diabetic patients in the modern era of PCI.


Asunto(s)
Enfermedad de la Arteria Coronaria/cirugía , Diabetes Mellitus/tratamiento farmacológico , Stents Liberadores de Fármacos , Insulina/uso terapéutico , Intervención Coronaria Percutánea/métodos , Sistema de Registros , Sirolimus/análogos & derivados , Anciano , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico , Femenino , Estudios de Seguimiento , Humanos , Hipoglucemiantes/uso terapéutico , Inmunosupresores/farmacología , Masculino , Polímeros , Pronóstico , Estudios Prospectivos , Diseño de Prótesis , Sirolimus/farmacología
3.
EuroIntervention ; 14(7): 772-779, 2018 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-29784631

RESUMEN

AIMS: Polymer-free biolimus-eluting stents (PF-BES) have been shown to be superior to bare metal stents in high bleeding risk (HBR) patients treated with one-month dual antiplatelet therapy (DAPT). However, limited evidence is available on PF-BES in non-HBR patients. We aimed to evaluate the safety and efficacy of PF-BES in all-comer patients undergoing percutaneous coronary intervention (PCI). METHODS AND RESULTS: Patients with stable coronary artery disease or acute coronary syndromes (ACS) undergoing PCI with PF-BES in routine clinical practice were included in a multicentre, prospective registry. DAPT duration was left to the discretion of the operator. The primary endpoint was the composite of cardiovascular death, myocardial infarction (MI), and definite/probable stent thrombosis (ST) at one year. Overall, 1,104 consecutive patients treated with PF-BES were included at 16 Italian centres. Mean age was 68.7±11.2 years, 77.2% of patients were male, 30% had diabetes, 15.1% had chronic kidney disease, and 40.5% had ACS at baseline. Mean CRUSADE score was 24.1±13.1, and 83.7% of patients did not have high bleeding risk features. At one year, the primary endpoint occurred in 4.1% of patients, cardiovascular death in 2.4%, MI in 1.8%, and definite/probable ST in 1.1%. With respect to efficacy, target lesion revascularisation occurred in 1.2% of patients. CONCLUSIONS: This is the first study providing clinical evidence on the use of PF-BES in all-comer patients irrespective of HBR status. Our findings suggest that PF-BES has a favourable safety and efficacy profile in a real-world clinical setting. Further investigation in randomised clinical trials against new-generation DES is warranted.


Asunto(s)
Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Polímeros , Estudios Prospectivos , Diseño de Prótesis , Sirolimus , Resultado del Tratamiento
4.
Catheter Cardiovasc Interv ; 74(4): 607-14, 2009 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-19360875

RESUMEN

BACKGROUND: Percutaneous closure of patent foramen ovale (PFO) is routinely performed with nonbiological devices, characterized by a persistent low-grade inflammatory response. We report our experience about PFO closure with a bioabsorbable device, BioSTAR (NMT Inc, USA). METHODS: From September 2007 to September 2008, 14 patients with migraine (eight with aura) and cerebral magnetic resonance positive for silent ischemia and nine patients with prior cardiovascular accident (CVA) underwent closure of PFO using BioSTAR. One patient had heterozygosis for sickle-cell-anaemia. Nickel allergy was present in eight patients. Echocardiogram was performed at 24 hr, one and 6 months. At 6 and 12 months a contrast-transcranial-doppler (c-TCD) and a trans-oesophageal echocardiogram (TOE) were scheduled, respectively. RESULTS: BioSTAR was successfully implanted in 22 patients (96%). The mean procedural time and the mean fluoroscopy time were 22 +/- 6 and 4 +/- 2 minutes, respectively. The mean in-hospital stay was 3 +/- 0.5 days. After a mean follow-up of 7.8 +/- 3.5 months there was an hemorrhagic stroke related to double antiaggregation. No other CVA or allergic reactions were registered. There were two cases of atrial arrhythmia. Fifteen patients had not residual shunts at c-TCD, while in four patients we observed a trivial microbubbles passage. The TOE, achieved in nine patients without contrast, showed the device well positioned, with a low profile and without thrombus. CONCLUSIONS: In our experience PFO closure with BioSTAR is safe and efficacious in preventing recurrent CVA. Its use could be advantageous in patients with nickel allergy and haematological disorders. The potential benefits of this device need to be certified in a larger cohort of patients with a longer follow-up.


Asunto(s)
Implantes Absorbibles , Cateterismo Cardíaco/instrumentación , Foramen Oval Permeable/terapia , Ataque Isquémico Transitorio/terapia , Trastornos Migrañosos/terapia , Dispositivo Oclusor Septal , Accidente Cerebrovascular/terapia , Adulto , Arritmias Cardíacas/etiología , Cateterismo Cardíaco/efectos adversos , Ecocardiografía Doppler en Color , Ecocardiografía Transesofágica , Femenino , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/diagnóstico , Humanos , Ataque Isquémico Transitorio/diagnóstico , Ataque Isquémico Transitorio/etiología , Tiempo de Internación , Masculino , Persona de Mediana Edad , Trastornos Migrañosos/diagnóstico , Trastornos Migrañosos/etiología , Diseño de Prótesis , Prevención Secundaria , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/etiología , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Doppler Transcraneal
5.
Catheter Cardiovasc Interv ; 73(2): 243-8, 2009 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-19156896

RESUMEN

OBJECTIVES: We sought to evaluate the safety and performance of the Janus Tacrolimus-Eluting stent (TES) in an unselected population of patients, without application of restrictive clinical or angiographic criteria. BACKGROUND: Continued attention to the safety, efficacy, and deliverability of first-generation drug eluting stents has led to the development of new antiproliferative agents with alternative stent platforms and different drug carrier vehicles. METHODS: The TEST (Tacrolimus Eluting STent) registry is a prospective, nonrandomized single-center registry in which 140 consecutive patients who underwent single- or multi-vessel percutaneous coronary intervention between February 2005 and August 2005 were enrolled. RESULTS: The composite rate of major adverse cardiac events (MACE) at 22 months clinical follow-up was 40.9%. The rate of mortality, myocardial infarction, and target lesion revascularization (TLR) were 5.5%, 11%, and 31.5%, respectively. Angiographic follow-up at 8 months was achieved in 74% of patients; binary restenosis occurred in 39.4% of lesions. Most restenosis lesions (94.6%) had a diffuse pattern, while focal restenosis was observed in 5.4% of cases. Definite or probable stent thrombosis was observed in 2.4% of patients. CONCLUSIONS: The present prospective, nonrandomized, TEST registry indicated high MACE and restenosis rates, and thereby rather discouraging long-term outcomes with use of the Janus TES in an unselected "real world" population of patients who underwent single- or multi-vessel percutaneous coronary intervention.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Angiografía Coronaria , Reestenosis Coronaria/prevención & control , Estenosis Coronaria/terapia , Stents Liberadores de Fármacos , Infarto del Miocardio/prevención & control , Tacrolimus/administración & dosificación , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Reestenosis Coronaria/mortalidad , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/mortalidad , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/etiología , Infarto del Miocardio/mortalidad , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Medición de Riesgo , Factores de Tiempo , Resultado del Tratamiento