Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
J Neurol Sci ; 455: 122806, 2023 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-38006829

RESUMEN

INTRODUCTION: Visual rating scales are increasingly utilized in clinical practice to assess atrophy in crucial brain regions among patients with cognitive disorders. However, their capacity to predict Alzheimer's disease (AD)-related pathology remains unexplored, particularly within a heterogeneous memory clinic population. This study aims to assess the accuracy of a novel visual rating assessment, the antero-posterior index (API) scale, in predicting amyloid-PET status. Furthermore, the study seeks to determine the optimal cohort-based cutoffs for the medial temporal atrophy (MTA) and parietal atrophy (PA) scales and to integrate the main visual rating scores into a predictive model. METHODS: We conducted a retrospective analysis of brain MRI and high-resolution TC scans from 153 patients with cognitive disorders who had undergone amyloid-PET assessments due to suspected AD pathology in a real-world memory clinic setting. RESULTS: The API scale (cutoff ≥1) exhibited the highest accuracy (AUC = 0.721) among the visual rating scales. The combination of the cohort-based MTA and PA threshold with the API yielded favorable accuracy (AUC = 0.787). Analyzing a cohort of MCI/Mild dementia patients below 75 years of age, the API scale and the predictive model improved their accuracy (AUC = 0.741 and 0.813, respectively), achieving excellent results in the early-onset population (AUC = 0.857 and 0.949, respectively). CONCLUSION: Our study emphasizes the significance of visual rating scales in predicting amyloid-PET positivity within a real-world memory clinic. Implementing the novel API scale, alongside our cohort-based MTA and PA thresholds, has the potential to substantially enhance diagnostic accuracy.


Asunto(s)
Enfermedad de Alzheimer , Disfunción Cognitiva , Humanos , Estudios Retrospectivos , Enfermedad de Alzheimer/diagnóstico , Disfunción Cognitiva/diagnóstico , Atrofia/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Tomografía de Emisión de Positrones
2.
Diagnostics (Basel) ; 13(19)2023 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-37835825

RESUMEN

In oligo-metastatic renal cell carcinoma (RCC), neither computed tomography (CT) nor bone scan is sensitive enough to detect small tumor deposits hampering early treatment and potential cure. Prostate-specific membrane antigen (PSMA) is a transmembrane glycoprotein expressed in the neo-vasculature of numerous malignant neoplasms, including RCC, that can be targeted by positron emission tomography (PET) using PSMA-targeting radioligands. Our aim was to investigate whether PSMA-expression patterns of renal cancer in the primary tumor or metastatic lesions on immunohistochemistry (IHC) are associated with PET/CT findings using [68Ga]-PSMA-HBED-CC (PSMA-PET/CT). We then analyzed the predictive and prognostic role of the PSMA-PET/CT signal. In this retrospective single-center study we included patients with renal cancer submitted to PSMA-PET/CT for staging or restaging, with tumor specimens available for PSMA-IHC. Clinical information (age, tumor type, and grade) and IHC results from the primary tumor or metastases were collected. The intensity of PSMA expression at IHC was scored into four categories: 0: none; 1: weak; 2: moderate; 3: strong. PSMA expression was also graded according to the proportion of vessels involved (PSMA%) into four categories: 0: none; 1: 1-25%; 2: 25-50%; 3: >50%. The intensity of PSMA expression and PSMA% were combined in a three-grade score: 0-2 absent or mildly positive, 3-4 moderately positive, and 5-6 strongly positive. PSMA scores were used for correlation with PSMA-PET/CT results. Results: IHC and PET scans were available for the analysis in 26 patients (22 ccRCC, 2 papillary RCC, 1 chromophobe, 1 "not otherwise specified" RCC). PSMA-PET/CT was positive in 17 (65%) and negative in 9 patients (35%). The mean and median SUVmax in the target lesion were 34.1 and 24.9, respectively. Reporter agreement was very high for both distant metastasis location and local recurrence (kappa 1, 100%). PSMA-PET detected more lesions than conventional imaging and revealed unknown metastases in 4 patients. Bone involvement, extension, and lesion number were greater than in the CT scan (median lesion number on PET/CT 3.5). The IHC PSMA score was concordant in primary tumors and metastases. All positive PSMA-PET/CT results (15/22 ccRCC, 1 papillary cancer type II, and 1 chromofobe type) were revealed in tumors with strong or moderate PSMA combined scores (3-4 and 5-6). In ccRCC tissue samples, PSMA expression was strong to moderate in 20/22 cases. The SUVmax values correlated to the intensity of PSMA expression which were assessed using IHC (p = 0.01), especially in the ccRCC subgroup (p = 0.009). Median survival was significantly higher in patients with negative PSMA-PET/CT (48 months) compared to patients with a positive scan (24 months, p= 0.001). SUVmax ≥ 7.4 provides discrimination of patients with a poor prognosis. Results of PSMA-PET/CT changed treatment planning. Conclusions: in renal cancer, positive PSMA-PET/CT is strongly correlated to the intensity of PSMA expression on immunohistochemistry in both ccRCC and chromophobe cancer. PSMA-PET/CT signal predicts a poor prognosis confirming its potential as an aggressiveness biomarker and providing paramount additional information influencing patient management.

3.
Chin Clin Oncol ; 12(3): 22, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37417288

RESUMEN

BACKGROUND: Prostate-specific membrane antigen (PSMA) positron emission tomography/computed tomography (PET/CT) is coming up as a superior imaging tool for prostate cancer (PCa). However, its use in primary staging is still debated. The aim of this study was to assess accuracy of 68Ga-PSMA PET/CT in staging patients with intermediate and high risk PCa candidates to radical prostatectomy managed in the Prostate Cancer Unit of our institution. METHODS: We retrospectively evaluated patients with biopsy-proven PCa staged through PSMA PET/CT before undergoing radical prostatectomy (RP) with extended pelvic lymph node dissection (ePLND). PET findings were categorized with respect to primary tumor (T), nodal (N) and distant metastasis (M). We analyzed the correspondence between PSMA PET/CT and final histopathological examination. RESULTS: We evaluated 42 men with high and intermediate risk PCa submitted to RP with ePLND. Mean age was 65.5 years (range, 49-76 years) and median preoperative prostate-specific antigen (PSA) was 13 ng/mL (IQR, 8.1-20 ng/mL). Patients in the high-risk group were 23 (54.7%), and the remainders were in the intermediate risk group. The mean risk of lymph node involvement (LNI) using the Memorial Sloan Kettering Cancer Center (MSKCC)-nomogram was 20%. The most common International Society of Urological Pathology (ISUP) grade was 3 (26.19%) after prostate biopsy. PSMA PET/CT showed focal prostatic uptake in 28 patients [mean value of maximum standardized uptake value (SUVmax) 18.5] and detected pelvic lymph node metastases in 6 cases (14.3%) with a median value of SUVmax 4.5 (IQR, 2-6.9). Histopathological examination detected lymph node metastases in seven patients (16.6%). In the only patient with negative PSMA PET/CT pathology revealed the presence of micrometastasis. After histopathological confirmation, sensitivity, specificity, positive and negative predictive values of pre-operative 68Ga-PSMA PET/CT were 85.7%, 100%, 100% and 97%, respectively. CONCLUSIONS: In our series, 68Ga-PSMA PET/CT holds high overall diagnostic value for lymph node staging in patients with intermediate and high risk PCa. Accuracy may depend on lymph node size.


Asunto(s)
Próstata , Neoplasias de la Próstata , Anciano , Humanos , Masculino , Ganglios Linfáticos/patología , Metástasis Linfática , Estadificación de Neoplasias , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Próstata/patología , Prostatectomía , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/cirugía , Neoplasias de la Próstata/patología , Estudios Retrospectivos , Persona de Mediana Edad
4.
Indian J Nucl Med ; 38(1): 1-7, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37180199

RESUMEN

Purpose of the Study: Ga-68-DOTA-peptides targeting somatostatin receptors have been assessed as a valuable tool in neuroendocrine tumors imaging using positron emission tomography (PET). A new selective and sensitive high-pressure liquid chromatography (HPLC) method was developed for determining chemical and radiochemical purity of Ga-68-DOTATATE (PET) tracer. The identification of peaks was achieved on a symmetry C18 column 3 µm 120Å (3.0 mm × 150 mm spherical particles) using (A) water + 0.1% trifluoroacetic acid (TFA) and (B) acetonitrile + 0.1% TFA, as the mobile phases at a flow rate of 0.600 mL/min and monitored at 220 nm. The run time was 16 min. Materials and Methods: The method was validated to fulfill International Conference on Harmonization requirements and EDQM guidelines, and it included specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, and precision. Results: The calibration curve was linear over the concentration range from 0.5 to 3 µg/ml, with a correlation coefficient (r2) equal to 0.999, average coefficient of variation (CV%) 2%, and average bias% did not deviate more than 5% for all concentrations. The LOD and LOQ for DOTATATE were 0.5 and 0.1 µg/mL, respectively. The method was considered precise, obtaining coefficients of variation between 0.22% and 0.52% for intraday and 0.20% and 0.61% for interday precision. Accuracy of method was confirmed with average bias% that did not deviate more than 5% for all concentrations. Conclusion: All results were acceptable and this confirmed that the method is suitable for its intended use in routine quality control of Ga-68-DOTATATE to guarantee the high quality of the finished product before release.

5.
Cancer Biother Radiopharm ; 38(4): 256-267, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37098169

RESUMEN

Aim: To assess the role of baseline 18F-fluorodeoxyglucose ([18F]FDG)-positron emission tomography/computed tomography (PET/CT) in predicting response to immunotherapy after 6 months and overall survival (OS) in patients with lung cancer (LC) or malignant melanoma (MM). Materials and Methods: Data from a multicenter, retrospective study conducted between March and November 2021 were analyzed. Patients >18 years old with a confirmed diagnosis of LC or MM, who underwent a baseline [18F]FDG-PET/CT within 1-2 months before starting immunotherapy and had a follow-up of at least 12 months were included. PET scans were examined visually and semiquantitatively by physicians at peripheral centers. The metabolic tumor burden (number of lesions with [18F]FDG-uptake) and other parameters were recorded. Clinical response was assessed at 3 and 6 months after starting immunotherapy, and OS was calculated as the time elapsing between the PET scan and death or latest follow-up. Results: The study concerned 177 patients with LC and 101 with MM. Baseline PET/CT was positive in primary or local recurrent lesions in 78.5% and 9.9% of cases, in local/distant lymph nodes in 71.8% and 36.6%, in distant metastases in 58.8% and 84%, respectively, in LC and in MM patients. Among patients with LC, [18F]FDG-uptake in primary/recurrent lung lesions was more often associated with no clinical response to immunotherapy after 6 months than in cases without any tracer uptake. After a mean 21 months, 46.5% of patients with LC and 37.1% with MM had died. A significant correlation emerged between the site/number of [18F]FDG foci and death among patients with LC, but not among those with MM. Conclusions: In patients with LC who are candidates for immunotherapy, baseline [18F]FDG-PET/CT can help to predict response to this therapy after 6 months, and to identify those with a poor prognosis based on their metabolic parameters. For patients with MM, there was only a weak correlation between baseline PET/CT parameters, response to therapy, and survival.


Asunto(s)
Neoplasias Pulmonares , Melanoma , Humanos , Adolescente , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Fluorodesoxiglucosa F18 , Estudios Retrospectivos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/terapia , Neoplasias Pulmonares/patología , Melanoma/diagnóstico por imagen , Melanoma/terapia , Inmunoterapia , Melanoma Cutáneo Maligno
6.
EJNMMI Radiopharm Chem ; 8(1): 3, 2023 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-36729317

RESUMEN

BACKGROUND: Recently it has been identified a short peptide that showed allosteric antagonism against C-C motif chemokine receptor 2 (CCR2) expressed on inflammatory monocyte and macrophages. A 7-D-amino acid peptidic CCR2 inhibitor called extracellular loop 1 inverso (ECL1i), d(LGTFLKC) has been identified and labeled to obtain a new probe for positron emission tomography in pulmonary fibrosis, heart injury, abdominal aortic aneurysm inflammation, atherosclerosis, head and neck cancer. Our goal was to develop, optimize and validate an automated synthesis method for [68Ga]68Ga-DOTA-ECL1i to make it available for a broader community. The synthesis of [68Ga]68Ga-DOTA-ECL1i was done using the Scintomics GRP® module with the already estabilished synthesis template for [68Ga]68Ga-DOTATOC/[68Ga]68Ga-PSMA. The radiopharmaceutical production was optimized scaling down the amount of DOTA-ECL1i (from 50 to 10 µg), evaluating synthesis efficiency and relevant quality control parameters in accordance with the European Pharmacopeia. RESULTS: Best results were yielded with 20 µg DOTA-ECL1i and then the process validation was carried out by producing three different batches on three different days obtaining an optimal radiochemical yield (66.69%) as well as radiochemical purity (100%) and molar activity (45.41 GBq/µmol). CONCLUSIONS: [68Ga]68Ga-DOTA-ECL1i was successfully synthesized and it is, thus, available for multi-dose application in clinical settings.

7.
Diagnostics (Basel) ; 12(10)2022 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-36291986

RESUMEN

Background: Titanium trabecular cages (TTCs) are emerging implants designed to achieve immediate and long-term spinal fixation with early osseointegration. However, a clear radiological and clinical demonstration of their efficacy has not yet been obtained. The purpose of this study was to evaluate the reactive bone activity of adjacent plates after insertion of custom-made titanium trabecular cages for the lumbar interbody with positron emission tomography (PET)/computed tomography (CT) 18F sodium fluoride (18F-NaF). Methods: This was an observational clinical study that included patients who underwent surgery for degenerative disease with lumbar interbody fusion performed with custom-made TTCs. Data related to the metabolic-reparative reaction following the surgery and its relationship with clinical follow-up from PET/CT performed at different weeks were evaluated. PET/CTs provided reliable data, such as areas showing abnormally high increases in uptake using a volumetric region of interest (VOI) comprising the upper (UP) and lower (DOWN) limits of the cage. Results: A total of 15 patients was selected for PET examination. Timing of PET/CTs ranged from one week to a maximum of 100 weeks after surgery. The analysis showed a negative correlation between the variables SUVmaxDOWN/time (r = -0.48, p = 0.04), ratio-DOWN/time (r = -0.53, p = 0.02), and ratio-MEAN/time (r = -0.5, p = 0.03). Shapiro-Wilk normality tests showed significant results for the variables ratio-DOWN (p = 0.002), ratio-UP (0.013), and ratio-MEAN (0.002). Conclusions: 18F-NaF PET/CT has proven to be a reliable tool for investigating the metabolic-reparative reaction following implantation of TTCs, demonstrating radiologically how this type of cage can induce reparative osteoblastic activity at the level of the vertebral endplate surface. This study further confirms how electron-beam melting (EBM)-molded titanium trabecular cages represent a promising material for reducing hardware complication rates and promoting fusion.

9.
Molecules ; 27(14)2022 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-35889351

RESUMEN

Background: Nowadays, in Nuclear Medicine, clinically applied radiopharmaceuticals must meet quality release criteria such as high radiochemical purity and radiochemical yield. Many radiopharmaceuticals do not have marketing authorization and have no dedicated monograph within European Pharmacopeia (Ph. Eur.); therefore, general monographs on quality controls (QCs) have to be applied for clinical application. These criteria require standardization and validation in labeling and preparation, including quality controls measurements, according to well defined standard operation procedures. However, QC measurements are often based on detection techniques that are specific to a certain chromatographic system. Several radiosyntheses of [68Ga]Ga-radiopharmaceuticals are more efficient and robust when they are performed with 2-[4-(2-hydroxyethyl)piperazin-1-yl] ethanesulfonic acid (HEPES) buffer, which is considered as an impurity to be assessed in the QC procedure, prior to clinical use. Thus, Ph. Eur. has introduced a thin-layer chromatography (TLC) method to quantify the HEPES amount that is present in [68Ga]Ga-radiopharmaceuticals. However, this is only qualitative and has proven to be unreliable. Here we develop and validate a new high-performance liquid chromatography (UV-Radio-HPLC) method to quantify the residual amount of HEPES in 68Ga-based radiopharmaceuticals. Method: To validate the proposed UV-Radio-HPLC method, a stepwise approach was used, as defined in the guidance document that was adopted by the European Medicines Agency (CMP/ICH/381/95 2014). The assessed parameters are specificity, linearity, precision (repeatability), accuracy, and limit of quantification. A range of concentrations of HEPES (100, 80, 60, 40, 20, 10, 5, 3 µg/mL) were analyzed. Moreover, to test the validity and pertinence of our new HPLC method, we analyzed samples of [68Ga]Ga-DOTATOC; [68Ga]Ga-PSMA; [68Ga]Ga-DOTATATE; [68Ga]Ga-Pentixafor; and [68Ga]Ga-NODAGA-Exendin-4 from different batches that were prepared for clinical use. Results: In the assessed samples, HEPES could not be detected by the TLC method that was described in Ph. Eur. within 4 min incubation in an iodine-saturated chamber. Our developed HPLC method showed excellent linearity between 3 and 100 µg/mL for HEPES, with a correlation coefficient (R2) for calibration curves that was equal to 0.999, coefficients of variation (CV%) < 2%, and percent deviation value of bias from 100% to 5%, in accordance with acceptance criteria. The intra-day and inter-day precision of our method was statistically confirmed and the limit-of-quantification (LOQ) was 3 µg/mL, confirming the high sensitivity of the method. The amount of HEPES that was detected with our developed HPLC method in the tested [68Ga]Ga-radiopharmaceuticals resulted well below the Ph. Eur. limit, especially for [68Ga]Ga-NODAGA-Exendin-4. Conclusions: The TLC method that is described in Ph. Eur. to assess residual HEPES in [68Ga]-based radiopharmaceuticals may not be sufficiently sensitive and thus unsuitable for QC release. Our new HPLC method was sensitive, quantitative, reproducible, and rapid for QCs, allowing us to exactly determine the residual HEPES amount in [68Ga]Ga-radiopharmaceuticals for safe patient administration.


Asunto(s)
Radioisótopos de Galio , Radiofármacos , Cromatografía Líquida de Alta Presión , Exenatida , Radioisótopos de Galio/química , HEPES , Tomografía de Emisión de Positrones , Cintigrafía , Radiofármacos/química
10.
Nucl Med Commun ; 43(5): 568-576, 2022 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-35190517

RESUMEN

BACKGROUND: Gallium-68 is a positron emitter for PET applications that can be produced without cyclotron by a germanium (Ge-68) chloride/gallium (Ga-68) chloride generator. Short half-life (67.71 min) of Ga-68, matching pharmacokinetic properties of small biomolecules, facilitates isotope utilization in compounding radiopharmaceuticals for PET imaging. The increasing cost of good manufacturing practice-compliant generators has strengthened the need for radionuclide efficient use by planning specific radiopharmaceutical sessions during the week, careful maintenance of the generator and achievement of high labeling yield and radiochemical purity (RCP) of the radiolabeled molecules. METHODS: The aim of this study was to evaluate the annual performance of five consecutive 68Ge/68Ga generators used for small-scale preparations of 68Ga-radiopharmaceuticals. To assess the long-term efficiency of isotope production we measured the weekly elution yield. To assess process efficiency we measured elution yield, labeling yield and RCP of four radiopharmaceutical preparations (68Ga-DOTATOC, 68Ga-PSMA-HBED-CC, 68Ga-PENTIXAFOR and 68Ga-DOTATATE). RESULTS: The annual mean elution yield of the generators was 74.7%, higher than that indicated by the manufacturer, and it never went below 65%. The Ge-68 level in the final products was under the detection limits in all the produced batches (mean value 0.0000048%). The RCP of radiopharmaceuticals determined by high-performance liquid chromatography was 98 ± 0.22%. The mean yield of radiolabelling was 64.68, 68.71, 57 and 63.68% for 68Ga-DOTATOC, 68Ga-PSMA-HBED-CC, 68GaPENTIXAFOR and 68Ga-DOTATATE. CONCLUSION: The ability to prepare in the hospital radiopharmacy high-purity and pharmaceutically acceptable 68Ga-radiolabeled probes on a routine basis facilitates patient access to precision imaging for clinical and research aims.


Asunto(s)
Radioisótopos de Galio , Radiofármacos , Cloruros , Isótopos de Galio , Radioisótopos de Galio/química , Humanos , Tomografía de Emisión de Positrones , Cintigrafía , Radiofármacos/química
11.
Molecules ; 27(2)2022 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-35056858

RESUMEN

Background: Glucagon-like peptide 1 receptor (GLP-1R) is preferentially expressed in pancreatic islets, especially in ß-cells, and highly expressed in human insulinomas and gastrinomas. In recent years several GLP-1R-avid radioligands have been developed to image insulin-secreting tumors or to provide a tentative quantitative in vivo biomarker of pancreatic ß-cell mass. Exendin-4, a 39-amino acid peptide with high binding affinity to GLP-1R, has been labeled with Ga-68 for imaging with positron emission tomography (PET). Preparation conditions may influence the quality and in vivo behavior of tracers. Starting from a published synthesis and quality controls (QCs) procedure, we have developed and validated a new rapid and simple UV-Radio-HPLC method to test the chemical and radiochemical purity of [68Ga]Ga-NODAGA-exendin-4, to be used in the clinical routine. Methods: Ga-68 was obtained from a 68Ge/68Ga Generator (GalliaPharma®) and purified using a cationic-exchange cartridge on an automated synthesis module (Scintomics GRP®). NODAGA-exendin-4 contained in the reactor (10 µg) was reconstituted with HEPES and ascorbic acid. The reaction mixture was incubated at 100 °C. The product was purified through HLB cartridge, diluted, and sterilized. To validate the proposed UV-Radio-HPLC method, a stepwise approach was used, as defined in the guidance document released by the International Conference on Harmonization of Technical Requirements of Pharmaceuticals for Human Use (ICH), adopted by the European Medicines Agency (CMP/ICH/381/95 2014). The assessed parameters are specificity, linearity, precision (repeatability), accuracy, and limit of quantification. Therefore, a range of concentrations of Ga-NODAGA-exendin-4, NODAGA-exendin-4 (5, 4, 3.125, 1.25, 1, and 0.75 µg/mL) and [68Ga]Ga-NODAGA-exendin-4 were analyzed. To validate the entire production process, three consecutive batches of [68Ga]Ga-NODAGA-exendin-4 were tested. Results: Excellent linearity was found between 5-0.75 µg/mL for both the analytes (NODAGA-exendin-4 and 68Ga-NODAGA-exendin-4), with a correlation coefficient (R2) for calibration curves equal to 0.999, average coefficients of variation (CV%) < 2% (0.45% and 0.39%) and average per cent deviation value of bias from 100%, of 0.06% and 0.04%, respectively. The calibration curve for the determination of [68Ga]Ga-NODAGA-exendin-4 was linear with a R2 of 0.993 and CV% < 2% (1.97%), in accordance to acceptance criteria. The intra-day and inter-day precision of our method was statistically confirmed using 10 µg of peptide. The mean radiochemical yield was 45 ± 2.4% in all the three validation batches of [68Ga]Ga-NODAGA-exendin-4. The radiochemical purity of [68Ga]Ga-NODAGA-exendin-4 was >95% (97.05%, 95.75% and 96.15%) in all the three batches. Conclusions: The developed UV-Radio-HPLC method to assess the radiochemical and chemical purity of [68Ga]Ga-NODAGA-exendin-4 is rapid, accurate and reproducible like its fully automated production. It allows the routine use of this PET tracer as a diagnostic tool for PET imaging of GLP-1R expression in vivo, ensuring patient safety.


Asunto(s)
Acetatos/química , Cromatografía Líquida de Alta Presión/métodos , Exenatida/química , Radioisótopos de Galio/química , Compuestos Heterocíclicos con 1 Anillo/química , Radiofármacos/análisis , Radiofármacos/química , Acetatos/análisis , Calibración , Cromatografía en Capa Delgada , Exenatida/análisis , Radioisótopos de Galio/análisis , Compuestos Heterocíclicos con 1 Anillo/análisis , Humanos , Insulinoma/diagnóstico , Tomografía de Emisión de Positrones/métodos , Radiofármacos/síntesis química , Rayos Ultravioleta
12.
Curr Radiopharm ; 15(1): 63-75, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-33687908

RESUMEN

BACKGROUND: Glucagon-like peptide 1 receptor (GLP-1R) is preferentially expressed in ß-cells, but it is highly expressed in human insulinomas and gastrinomas. Several GLP-1 receptor- avid radioligands have been developed to image insulin-secreting tumors or to provide a quantitative in vivo biomarker of pancreatic ß-cell mass. Exendin-4 is a high affinity ligand of the GLP1- R, which is a candidate for being labeled with a PET isotope and used for imaging purposes. OBJECTIVE: Here, we report the development and validation results of a semi-manual procedure to label [Lys40,Nle14(Ahx-NODAGA)NH2]exendin-4, with Ga-68. METHODS: A68Ge/68Ga Generator (GalliaPharma®, Eckert and Ziegler) was eluted with 0.1M HCl on an automated synthesis module (Scintomics GRP®). The peptide contained in the kit vial (Radioisotope Center POLATOM) in different amounts (10-20-30 µg) was reconstituted with 2-[4-(2-hydroxyethyl)piperazin-1-yl]ethansulfonic acid (HEPES) solution and 68GaCl3 (400-900 MBq), followed by 10 min incubation at 95°C. The reaction solution was then purified through an Oasis HLB column. The radiopharmaceutical product was tested for quality controls (CQs) in accordance with the European Pharmacopoeia standards. RESULTS: The synthesis of [68Ga]Ga-NODAGA-Exendin-4 provided optimal results with 10 µg of peptide, getting the best radiochemical yield (23.53 ± 2.4%), molar activity (100 GBq/µmol) and radiochemical purity (91.69%). CONCLUSION: The study developed an imaging tool [68Ga]Ga-NODAGA-Exendin-4, avoiding pharmacological effects of exendin-4, for the clinical community.


Asunto(s)
Radioisótopos de Galio , Neoplasias Pancreáticas , Acetatos , Exenatida , Estudios de Factibilidad , Receptor del Péptido 1 Similar al Glucagón , Compuestos Heterocíclicos con 1 Anillo , Hospitales , Humanos , Péptidos , Radiofármacos
13.
Am J Nucl Med Mol Imaging ; 11(4): 300-306, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34513283

RESUMEN

Coronavirus disease 2019 (COVID-19) pathology is associated with neoangiogenesis and interstitial pneumonia. 68Ga-PSMA-11-PET/CT is able to image in vivo PSMA (Prostate-Specific Membrane Antigen) expression on both prostate cancer (PCa) cells and neovasculature endothelial cells. The aim of the case series was to explore pulmonary PSMA expression not related to cancer in patients with PCa and concomitant COVID-19. In this retrospective, multicenter case series, patients who underwent 68Ga-PSMA-11-PET/CT for PCa and concomitant proven COVID-19 infection were analyzed. Patients were stratified according to 68Ga-PSMA-11 intensity of uptake in the lung (SUVmax). Low uptake: < blood pool; mild-to-moderate uptake: > blood pool and < liver; intense uptake: > liver. Potential correlation between pulmonary 68Ga-PSMA-11 uptake not related to PCa and CT patterns typical for COVID-19 was assessed. Nine patients were included, all of them presenting abnormal 68Ga-PSMA-11 uptake, at different grades: 2/9 low, 6/9 mild-to-moderate, 1/9 high. Uptake distribution was generally bilateral, peripheral and posterior, positively matching with ground-glass CT alterations in 7/9 (78%) patients, while mismatch was observed in 2/9 (22%). 1/9 patients presented PCa lung metastases at 68Ga-PSMA-11. 68Ga-PSMA-11-PET/CT detected increased PSMA uptake within the lung, not related to PCa, matching with CT typical COVID-19 patterns in almost all patients. Further studies are needed to evaluate the role of 68Ga-PSMA-11 PET in COVID-19 patients and the potential role of PSMA overexpression as a biomarker for neoangiogenesis, in both oncological and infective disorders.

14.
Clin Nucl Med ; 46(9): e458-e460, 2021 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-34374683

RESUMEN

ABSTRACT: Renal cell carcinoma (RCC) shows variable FDG uptake; recently, PET/CT with prostate-specific membrane antigen (PSMA)-target radiotracers was demonstrated to be a promising tool in staging and restaging of RCC patients. We describe the case of a 77-year-old man with a lung metastasis of papillary RCC missed by CT scan who successfully underwent [18F]FDG PET/CT restaging. Targeted therapy with sunitinib was administered. A [68Ga]PSMA PET/CT performed during follow-up demonstrated, among the already known lesions, also a bone marrow metastasis, missed by previous CT scans. This case demonstrates that PET/CT molecular imaging with [18F]FDG and [68Ga]PSMA is superior to conventional imaging in RCC restaging and in assessing therapy response.


Asunto(s)
Carcinoma de Células Renales , Neoplasias Renales , Anciano , Carcinoma de Células Renales/diagnóstico por imagen , Fluorodesoxiglucosa F18 , Humanos , Neoplasias Renales/diagnóstico por imagen , Masculino , Recurrencia Local de Neoplasia/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones , Próstata
16.
Curr Radiopharm ; 14(2): 121-130, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-32990551

RESUMEN

BACKGROUND: Due to its overexpression in a variety of tumor types, the chemokine receptor 4 (CXCR4) represents a highly relevant diagnostic and therapeutic target in nuclear oncology. Recently, [68Ga]Ga-DOTA-Pentixafor has emerged as an excellent imaging agent for positron emission tomography (PET) of CXCR4 expression in vivo. Preparation conditions may influence the quality and in vivo behaviour of this tracer and no standard procedure for the quality controls (QCs) is available. OBJECTIVE: The developed analytical test method was validated because a specific monograph in the Pharmacopoeia is not available for [68Ga]Ga-DOTA-Pentixafor. METHOD: A stepwise approach was used based on the quality by design (QbD) concept of the ICH Q2 (R1) and Q8 (Pharmaceutical Development) guidelines in accordance with the regulations and requirements of EANM, SNM, IAEA and WHO. RESULTS: The purity and quality of the radiopharmaceutical obtained according to the proposed method were found to be high enough to safely administrate it to patients. Excellent linearity was found between 0.5 and 4 µg/mL, with a correlation coefficient (r2) for calibration curves being equal to 0.999, the average coefficient of variation (CV%) < 2% and average bias% that did not deviate more than 5% for all concentrations. CONCLUSION: This study developed a new rapid and simple HPLC method of analysis for the routine QCs of [68Ga]Ga-DOTA-Pentixafor to guarantee the high quality of the finished product before release.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Complejos de Coordinación/química , Péptidos Cíclicos/química , Tomografía de Emisión de Positrones , Radiofármacos/química , Complejos de Coordinación/administración & dosificación , Radioisótopos de Galio/química , Humanos , Péptidos Cíclicos/administración & dosificación , Radioquímica , Radiofármacos/administración & dosificación , Receptores CXCR4
17.
BMC Geriatr ; 20(1): 337, 2020 09 09.
Artículo en Inglés | MEDLINE | ID: mdl-32907545

RESUMEN

BACKGROUND: The association between amyloid deposition and cognitive, behavioral and physical performance in mild cognitive impairment (MCI) due to Alzheimer's disease (AD) has been poorly investigated, especially in older persons. METHODS: We studied the in vivo correlation between the amyloid deposition at Positron Emission Tomography (amyloid-PET) and the presence of memory loss, reduced executive function, neuropsychiatric symptoms and physical performance in older persons with MCI. Amyloid-PET was performed with 18F-flutemetamol and quantitatively analyzed. RESULTS: We evaluated 48 subjects, 21 men and 27 women. We performed in each patient a comprehensive geriatric assessment (CGA) including Mini Mental State Examination (MMSE), Clock Drawing Test (CDT), Activity Daily Living (ADL), Instrumental Activity of Daily Living (IADL), Neuropsychiatric inventory (NPI) questionnaire, 15 Geriatric Depression Scale (GDS), Short Physical Performance Battery (SPPB) and Hand Grip strength. Then, each patient underwent amyloid-PET. Mean age of the enrolled subjects was 74.6 ± 7.8 years. All of these subjects showed preserved cognitive function at MMSE > 24, while 29 of 48 subjects (61.0%) had altered CDT. Mean NPI score was 6.9 ± 5.9. The mean value of SPPB score was 9.0 ± 2.6, while the average muscle strength of the upper extremities measured by hand grip was 25.6 ± 7.7 Kg. CT/MRI images showed cortical atrophic changes in 26 of the 48 examined subjects (54.0%), while cerebrovascular modifications were present in 31 subjects (64.5%). Pathological burden of amyloid deposits was detected in 25 of 48 (52.0%) patients with a mean value of global z-score of 2.8 (subjects defined as MCI due to AD). After stratifying subjects in subclasses of clinical alterations, more probability of pathological amyloid deposition was found in subjects with impaired CDT and higher NPI score (O.R. = 3.45 [1.01-11.2], p = 0.04), with both impaired CDT and low physical performance (O.R. = 5.80 [1.04-32.2], p = 0.04), with altered CDT and high NPI score (O.R. = 7.98 [1.38-46.0], p = 0.02), and finally in those subjects with altered CDT, high NPI and low physical performance (O.R. = 5.80 [1.05-32.2], p = 0.04). CONCLUSION: Our findings support the recent hypothesis that amyloid deposition could be associated with multiple cerebral dysfunction, mainly affecting executive, behavioral and motor abilities.


Asunto(s)
Enfermedad de Alzheimer , Disfunción Cognitiva , Anciano , Anciano de 80 o más Años , Disfunción Cognitiva/diagnóstico por imagen , Femenino , Evaluación Geriátrica , Fuerza de la Mano , Humanos , Masculino , Tomografía de Emisión de Positrones
18.
Tumori ; 106(4): 325-332, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32567505

RESUMEN

INTRODUCTION: In January 2020, the coronavirus disease 2019 (COVID-19) outbreak in Italy necessitated rigorous application of more restrictive safety procedures in the management and treatment of patients with cancer to ensure patient and staff protection. Identification of respiratory syndrome coronavirus 2 (SARS-CoV-2) infection was a challenge during the pandemic owing to a large number of asymptomatic or mildly symptomatic patients. METHODS: We report 5 patients with unknown SARS-CoV-2 infection undergoing positron emission tomography (PET)/computed tomography (CT) with radiopharmaceuticals targeting different tumor processes: 18F-FDG, 18F-choline (FCH), and 68Ga-PSMA. RESULTS: In all patients, PET/CT showed increased tracer uptake in the lungs corresponding to CT findings of SARS-CoV-2 pneumonia. Quantitative assessment of tracer uptake showed more elevated values for the glucose analogue 18F-FDG (mean SUVmax 5.4) than for the other tracers (mean SUVmax 3.5). CONCLUSIONS: Our findings suggest that PET/CT is a sensitive modality to hypothesize SARS-CoV-2 pneumonia in patients with cancer, even when asymptomatic. More data are needed to verify the correlation among immune response to SARS-CoV-2 infection, clinical evolution, and PET results. Under the strict safety measures implemented at the PET center, the number of potentially SARS-CoV-2-positive patients undergoing PET/CT was very low (1.6%), and no staff member has been diagnosed with infection as of April 30, 2020.


Asunto(s)
Infecciones por Coronavirus/diagnóstico , Neoplasias/diagnóstico , Neumonía Viral/diagnóstico , Neumonía/diagnóstico , Tomografía Computarizada por Tomografía de Emisión de Positrones , Betacoronavirus/patogenicidad , COVID-19 , Medios de Contraste/uso terapéutico , Infecciones por Coronavirus/complicaciones , Infecciones por Coronavirus/terapia , Infecciones por Coronavirus/virología , Brotes de Enfermedades , Femenino , Fluorodesoxiglucosa F18/uso terapéutico , Isótopos de Galio , Radioisótopos de Galio , Humanos , Italia/epidemiología , Pulmón/diagnóstico por imagen , Pulmón/patología , Masculino , Glicoproteínas de Membrana/uso terapéutico , Neoplasias/complicaciones , Neoplasias/terapia , Neoplasias/virología , Compuestos Organometálicos/uso terapéutico , Pandemias , Neumonía/complicaciones , Neumonía/terapia , Neumonía/virología , Neumonía Viral/complicaciones , Neumonía Viral/terapia , Neumonía Viral/virología , Radiofármacos/uso terapéutico , SARS-CoV-2
19.
Tumori ; : 300891620904404, 2020 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-32056506

RESUMEN

OBJECTIVE: To evaluate the prognostic role of maximum standardized uptake value (SUVmax), metabolic tumor volume (MTV), and total lesion glycolysis (TLG) measured by FDG-positron emission tomography (PET)/computed tomography (CT) in patients with primary lung adenocarcinoma undergoing surgical resection. METHODS: All consecutive patients undergoing curative surgery for primary lung adenocarcinoma at the Thoracic Surgery Unit of the University Hospital of Parma between January 2009 and December 2014 were retrospectively analyzed. The cutoff point of each continuous PET parameter was determined through receiver operating characteristic curve and Youden index, using overall survival (OS) as the classification status. Univariate and multivariate Cox proportional hazards models were applied to evaluate the association between OS and potential prognostic variables, including SUVmax, MTV, and TLG. RESULTS: A total of 193 patients were considered eligible for this study. The mean 5-year OS rate was 70.5 ± 3.5%. Acinar and lepidic patterns were more frequently associated with absent or low (<2.5) SUVmax values [18F]FDG uptake. At univariate analysis, male sex, advanced stage, micropapillary and solid pattern, lymphatic, blood vessels and pleural invasion, high SUVmax, MTV, and TLG were significantly associated with poorer OS. Multivariate analyses revealed that only sex, stage, and TLG were independent factors for OS, with male sex, stage 3+4, and high TLG value (p = 0.041) significantly associated with poorer OS. CONCLUSIONS: In this study, [18F]FDG PET/CT parameters SUVmax, MTV, and TLG were prognostic factors in patients with surgically resected lung adenocarcinoma, able to predict OS and helping to further stratify these patients into prognostic subsets. Elevated TLG was also an independent predictor for shorter OS.

20.
J Alzheimers Dis ; 73(4): 1647-1659, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31958094

RESUMEN

BACKGROUND: Free and Cued Selective Reminding Test (FCSRT) is a reliable cognitive marker for Alzheimer's disease (AD), and the identification of neuropsychological tests sensitive to the early signs of AD pathology is crucial both in research and clinical practice. OBJECTIVE: The study aimed to ascertain the ability of FCSRT in predicting the amyloid load as determined from amyloid PET imaging (Amy-PET) in patients with cognitive disorders. METHODS: For our purpose, 79 patients (71 MCI, 8 mild dementia) underwent a complete workup for dementia, including the FCSRT assessment and a [18F]florbetaben PET scan. FCSRT subitem scores were used as predictors in different binomial regression models. RESULTS: Immediate free recall and delayed free recall were the best predictors overall in the whole sample; whereas in patients <76 years, all models further improved with immediate total recall (ITR) and Index of Sensitivity of Cueing (ISC) resulting the most accurate in anticipating Amy-PET results, with a likelihood of being Amy-PET positive greater than 85% for ITR and ISC scores of less than 25 and 0.5, respectively. CONCLUSION: FCSRT proved itself to be a valid tool in dementia diagnosis, also being able to correlate with amyloid pathology. The possibility to predict Amy-PET results through a simple and reliable neuropsychological test might be helpful for clinicians in the dementia field, adding value to a paper and pencil tool compared to most costly biomarkers.


Asunto(s)
Compuestos de Anilina , Disfunción Cognitiva/diagnóstico por imagen , Disfunción Cognitiva/psicología , Señales (Psicología) , Demencia/diagnóstico por imagen , Demencia/psicología , Pruebas Neuropsicológicas , Tomografía de Emisión de Positrones/métodos , Radiofármacos , Estilbenos , Adulto , Anciano , Anciano de 80 o más Años , Carga Corporal (Radioterapia) , Angiopatía Amiloide Cerebral/diagnóstico por imagen , Angiopatía Amiloide Cerebral/psicología , Progresión de la Enfermedad , Femenino , Humanos , Masculino , Recuerdo Mental , Pruebas de Estado Mental y Demencia , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Desempeño Psicomotor , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...