Phys Med Biol ; 67(8)2022 04 04.
Artículo en Inglés | MEDLINE | ID: mdl-35263722

RESUMEN

Objective. To investigate the feasibility to train artificial neural networks (NN) to recover lateral dose profiles from detector measurements in a magnetic field.Approach. A novel framework based on a mathematical convolution model has been proposed to generate measurement-less training dataset. 2D dose deposition kernels and detector lateral fluence response functions of two air-filled ionization chambers and two diode-type detectors have been simulated without magnetic field and for magnetic fieldB = 0.35 and 1.5 T. Using these convolution kernels, training dataset consisting pairs of dose profilesDx,yand signal profilesMx,ywere computed for a total of 108 2D photon fluence profilesψ(x,y)(80% training/20% validation). The NN were tested using three independent datasets, where the second test dataset has been obtained from simulations using realistic phase space files of clinical linear accelerator and the third test dataset was measured at a conventional linac equipped with electromagnets. Mainresults. The convolution kernels show magnetic field dependence due to the influence of the Lorentz force on the electron transport in the water phantom and detectors. The NN show good performance during training and validation with mean square error reaching a value of 1e-6 or smaller. The corresponding correlation coefficientsRreached the value of 1 for all models indicating an excellent agreement between expectedDx,yand predictedDpredx,y.The comparisons betweenDx,yandDpredx,yusing the three test datasets resulted in gamma indices (1 mm/1% global) <1 for all evaluated data points.Significance. Two verification approaches have been proposed to warrant the mathematical consistencies of the NN outputs. Besides offering a correction strategy not existed so far for relative dosimetry in a magnetic field, this work could help to raise awareness and to improve understanding on the distortion of detector's signal profiles by a magnetic field.


Asunto(s)
Fotones , Radiometría , Aprendizaje Automático , Campos Magnéticos , Método de Montecarlo , Aceleradores de Partículas , Radiometría/métodos
3.
Phys Med Biol ; 67(4)2022 02 09.
Artículo en Inglés | MEDLINE | ID: mdl-35016163

RESUMEN

Objective.This study investigates the perturbation correction factors of air-filled ionization chambers regarding their depth and magnetic field dependence. Focus has been placed on the displacement or gradient correction factorPgr.Additionally, the shift of the effective point of measurementPeffthat can be applied to account for the gradient effect has been compared between the cases with and without magnetic field.Approach.The perturbation correction factors have been simulated by stepwise modifications of the models of three ionization chambers (Farmer 30013, Semiflex 3D 31021 and PinPoint 3D 31022, all from PTW Freiburg). A 10 cm × 10 cm 6 MV photon beam perpendicular to the chamber's axis was used. A 1.5 T magnetic field was aligned parallel to the chamber's axis. The correction factors were determined between 0.4 and 20 cm depth. The shift ofPefffrom the chamber's reference pointPref,Δz,was determined by minimizing the variation of the ratio between dose-to-waterDwzref+Δzand the dose-to-airD¯airzrefalong the depth.Main Results.The perturbation correction factors with and without magnetic field are depth dependent in the build-up region but can be considered as constant beyond the depth of dose maximum. Additionally, the correction factors are modified by the magnetic field.Pgrat the reference depth is found to be larger in 1.5 T magnetic field than in the magnetic field free case, where an increase of up to 1% is observed for the largest chamber (Farmer 30013). The magnitude ofΔzfor all chambers decreases by 40% in a 1.5 T magnetic field with the sign ofΔzremains negative.Significance.In reference dosimetry, the change ofPgrin a magnetic field can be corrected by applying the magnetic field correction factorkQmsrBwhen the chamber is positioned with itsPrefat the depth of measurement. However, due to the depth dependence of the perturbation factors, it is more convenient to apply theΔz-shift during chamber positioning in relative dosimetry.


Asunto(s)
Campos Magnéticos , Radiometría , Método de Montecarlo , Fotones
4.
J Appl Clin Med Phys ; 22(12): 64-71, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34633745

RESUMEN

The purpose of this work is to study the feasibility of photon beam profile deconvolution using a feedforward neural network (NN) in very small fields (down to 0.56 × 0.56 cm2 ). The method's independence of the delivery and scanning system is also investigated. Lateral beam profiles of photon fields between 0.56 × 0.56 cm2 and 4.03 × 4.03 cm2 were collected on a Siemens Artiste linear accelerator. Three scanning ionization chambers (SNC 125c, PTW 31021, and PTW 31022) of sensitive volumes ranging from 0.016 cm3 to 0.108 cm3 were used with a PTW MP3 water phantom. A reference dataset was also collected with a PTW 60019 microDiamond detector to train and test individual NNs for each ionization chamber. Further testing of the trained NNs was performed with additional test data collected on an Elekta Synergy linear accelerator using a Sun Nuclear 3D Scanner. The results were evaluated with a 1D gamma analysis (0.5 mm/0.5%). After the deconvolution, the gamma passing rates increased from 54.79% to 99.58% for the SNC 125c, from 57.09% to 99.83% for the PTW 31021, and from 91.03% to 96.36% for the PTW 31022. The delivery system, the scanning system, the scanning mode (continuous vs. step-by-step), and the electrometer had no significant influence on the results. This study successfully demonstrated the feasibility of using NN to correct the beam profiles of very small photon fields collected with ionization chambers of various sizes. Its independence of the delivery and scanning system was also shown.


Asunto(s)
Aceleradores de Partículas , Radiometría , Humanos , Redes Neurales de la Computación , Fantasmas de Imagen , Fotones
5.
Phys Med Biol ; 66(15)2021 07 19.
Artículo en Inglés | MEDLINE | ID: mdl-34181591

RESUMEN

The aim of the present work is to investigate the behavior of two diode-type detectors (PTW microDiamond 60019 and PTW microSilicon 60023) in transverse magnetic field under small field conditions. A formalism based on TRS 483 has been proposed serving as the framework for the application of these high-resolution detectors under these conditions. Measurements were performed at the National Metrology Institute of Germany (PTB, Braunschweig) using a research clinical linear accelerator facility. Quadratic fields corresponding to equivalent square field sizesSbetween 0.63 and 4.27 cm at the depth of measurement were used. The magnetic field strength was varied up to 1.4 T. Experimental results have been complemented with Monte Carlo simulations up to 1.5 T. Detailed simulations were performed to quantify the small field perturbation effects and the influence of detector components on the dose response. The does response of both detectors decreases by up to 10% at 1.5 T in the largest field size investigated. InS = 0.63 cm, this reduction at 1.5 T is only about half of that observed in field sizesS > 2 cm for both detectors. The results of the Monte Carlo simulations show agreement better than 1% for all investigated conditions. Due to normalization at the machine specific reference field, the resulting small field output correction factors for both detectors in magnetic fieldkQclin,QmsrBare smaller than those in the magnetic field-free case, where correction up to 6.2% at 1.5 T is required for the microSilicon in the smallest field size investigated. The volume-averaging effect of both detectors was shown to be nearly independent of the magnetic field. The influence of the enhanced-density components within the detectors has been identified as the major contributors to their behaviors in magnetic field. Nevertheless, the effect becomes weaker with decreasing field size that may be partially attributed to the deficiency of low energy secondary electrons originated from distant locations in small fields.


Asunto(s)
Fotones , Radiometría , Campos Magnéticos , Método de Montecarlo , Aceleradores de Partículas
6.
Med Phys ; 48(8): 4572-4585, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34032298

RESUMEN

PURPOSE: The magnetic-field correction factors k B , Q of compact air-filled ionization chambers have been investigated experimentally and using Monte Carlo simulations up to 1.5 T. The role of the nonsensitive region within the air cavity and influence of the chamber construction on its dose response have been elucidated. MATERIALS AND METHODS: The PTW Semiflex 3D 31021, PinPoint 3D 31022, and Sun Nuclear Cooperation SNC125c chambers were studied. The k B , Q factors were measured at the experimental facility of the German National Metrology Institute (PTB) up to 1.4 T using a 6 MV photon beam. The chambers were positioned with the chamber axis perpendicular to the beam axis (radial); and parallel to the beam axis (axial). In both cases, the magnetic field was directed perpendicular to both the beam axis and chamber axis. Additionally, the sensitive volumes of these chambers have been experimentally determined using a focused proton microbeam and finite element method. Beside the simulations of k B , Q factors, detailed Monte Carlo technique has been applied to analyse the secondary electron fluence within the air cavity, that is, the number of secondary electrons and the average path length as a function of the magnetic field strength. RESULTS: A nonsensitive volume within the air cavity adjacent to the chamber stem for the PTW chambers has been identified from the microbeam measurements and FEM calculations. The dose response of the three investigated ionization chambers does not deviate by more than 4% from the field-free case within the range of magnetic fields studied in this work for both the radial and axial orientations. The simulated k B , Q for the fully guarded PTW chambers deviate by up to 6% if their sensitive volumes are not correctly considered during the simulations. After the implementation of the sensitive volume derived from the microbeam measurements, an agreement of better than 1% between the experimental and Monte Carlo k B , Q factors for all three chambers can be achieved. Detailed analysis reveals that the stem of the PTW chambers could give rise to a shielding effect reducing the number of secondary electrons entering the air cavity in the presence of magnetic field. However, the magnetic field dependence of their path length within the air cavity is shown to be weaker than for the SNC125c chamber, where the length of the air cavity is larger than its diameter. For this chamber it is shown that the number of electrons and their path lengths in the cavity depend stronger on the magnetic field. DISCUSSION AND CONCLUSION: For clinical measurements up to 1.5 T, the required k B , Q corrections of the three chambers could be kept within 3% in both the investigated chamber orientations. The results reiterate the importance of considering the sensitive volume of fully guarded chambers, even for the investigated compact chambers, in the Monte Carlo simulations of chamber response in magnetic field. The resulting magnetic field-dependent dose response has been demonstrated to depend on the chamber construction, such as the ratio between length and the diameter of the air cavity as well as the design of the chamber stem.


Asunto(s)
Campos Magnéticos , Radiometría , Electrones , Humanos , Método de Montecarlo , Fotones , Protones
7.
Med Phys ; 47(12): 6509-6518, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33074591

RESUMEN

PURPOSE: This study aims to investigate the dose response of diode-type detectors in the presence of strong magnetic field and to understand the underlying mechanisms leading to the observed magnetic field dependence by close examinations on the role of the detector's design. MATERIALS AND METHODS: Three clinical diode-type detectors (PTW microSilicon type 60023, PTW microDiamond type 60019, and IBA Razor diode) have been studied. Measurements were performed at the linear accelerator experimental facility of the German National Metrology Institute (PTB, Braunschweig) with electromagnets up to 1.4 T to obtain the magnetic field correction factors k B , Q . The experimental results were compared to Monte Carlo simulations. Stepwise modifications of the detectors' models were performed to characterize the contributions of the structural components toward the magnetic field-dependent dose response. Additionally, systematic Monte Carlo study was conducted to elucidate the influence of the structural layers with varying density located above and beneath the detector's sensitive volume. RESULTS: The dose response of all investigated detectors decreases with magnetic field. As a result, the associated k B , Q factors increase by approximately 10% for the PTW detectors, and by 5% for the IBA Razor diode at 1.5 T. The sensitive volume itself was shown to cause negligible effect but the diode substrate with enhanced density situated directly below the sensitive volume contributes strongest to the observed magnetic field dependence. Systematic simulations revealed that k B , Q increases with magnetic field if the density of the structural layer located beneath the sensitive volume is higher than that of normal water (>1 g/cm3 ). In the case where the layer consists of low-density water (1.2 mg/cm3 ), k B , Q decreases with the magnetic field strength. On the contrary , if the structural layer with varying density is situated above the sensitive volume, the reversed effect could be observed. DISCUSSION AND CONCLUSION: The experimental and Monte Carlo results demonstrated that the dose response of the investigated diode-type detectors decreases in magnetic field. This observation can be generally attributed to the common construction of diode-type detectors, where structural components with enhanced density, for example the diode substrate, are situated below the sensitive volume. The results provide deeper insights into the behavior of clinical diode detectors when used in strong magnetic field.


Asunto(s)
Aceleradores de Partículas , Radiometría , Campos Magnéticos , Método de Montecarlo , Fotones
8.
Z Med Phys ; 30(4): 300-304, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32278506

RESUMEN

Accurate ionization chamber measurements of the absorbed dose to water require the correction of incomplete collection of charges created within the chamber volume. According to current dosimetry protocols such as the TRS-398 or the DIN 6800-2, incomplete charge collection is accounted for by the correction factor ks, which can be determined numerically or experimentally. The method proposed by Burns & McEwen (Phys. Med. Biol., 1998) was used in this study to determine the coefficients γ and δ used for the calculation of the correction factor ks of three ionization chambers, the SNC 125c, the SNC 600c and the SNC 350p (all Sun Nuclear Corp., Melbourne, Florida) for an absorbed dose to water range of 0.2mGy to 1.6mGy per pulse in pulsed photon beams. The shift of the effective point of measurement from the reference point Δz and the correction factor kr were determined for the SNC 350p according to the draft DIN 6800-2:2019-07.


Asunto(s)
Fotones , Radiometría/instrumentación , Aceleradores de Partículas , Agua
9.
Med Phys ; 46(9): 4257-4262, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31309594

RESUMEN

PURPOSE: Dosimetric properties of the new microSilicon diode detector (60023) have been studied with focus on application in small-field dosimetry. The influences of the dimensions of the sensitive volume and the density of the epoxy layer surrounding the silicon chip of microSilicon have been quantified and compared to its predecessor (Diode E 60017) and the microDiamond (60019, all PTW-Freiburg, Germany). METHODS: Dose linearity has been studied in the range from 0.01 to 8.55 Gy and dose-per-pulse dependence from 0.13 to 0.86 mGy/pulse. The effective point of measurement (EPOM) was determined by comparing measured percentage depth dose curves with a reference curve (Roos chamber). Output ratios were measured for nominal field sizes from 0.5 × 0.5  cm2 to 4 × 4 cm2 . The corresponding small-field output correction factors, k, were derived with a plastic scintillation detector as reference. The lateral dose-response function, K(x), was determined using a slit beam geometry. RESULTS: MicroSilicon shows linear dose response (R2  = 1.000) in both low and high dose range up to 8.55 Gy with deviations of only up to 1% within the dose-per-pulse values investigated. The EPOM was found to lie (0.7 ± 0.2) mm below the front detector's surface. The derived k for microSilicon (0.960 at seff  = 0.55 cm) is similar to that of microDiamond (0.956), while Diode E requires larger corrections (0.929). This improved behavior of microSilicon in small-fields is reflected in the slightly wider K(x) compared to Diode E. Furthermore, the amplitude of the negative values in K(x) at the borders of the sensitive volume has been reduced. CONCLUSIONS: Compared to its predecessor, microSilicon shows improved dosimetric behavior with higher sensitivity and smaller dose-per-pulse dependence. Profile measurements demonstrated that microSilicon causes less perturbation in off-axis measurements. It is especially suitable for the applications in small-field output factors and profile measurements.


Asunto(s)
Equipos y Suministros Eléctricos , Radiometría/instrumentación , Silicio , Modelos Lineales