Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Diabet Med ; 40(9): e15116, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37052409

RESUMEN

AIMS: To compare the time required for perioperative glucose management using fully automated closed-loop versus standard insulin therapy. METHODS: We performed a time-motion study to quantify the time requirements for perioperative glucose management with fully closed-loop (FCL) and standard insulin therapy applied to theoretical scenarios. Following an analysis of workflows in different periods of perioperative care in elective surgery patients receiving FCL or standard insulin therapy upon hospital admission (pre- and intra-operatively, at the intermediate care unit and general wards), the time of process-specific tasks was measured by shadowing hospital staff. Each task was measured 20 times and its average duration in combination with its frequency according to guidelines was used to calculate the cumulative staff time required for blood glucose management. Cumulative time was calculated for theoretical scenarios consisting of elective minor and major abdominal surgeries (pancreatic surgery and sleeve gastrectomy, respectively) to account for the different care settings and lengths of stay. RESULTS: The FCL insulin therapy reduced the time required for perioperative glucose management compared to standard insulin therapy, across all assessed care periods and for both perioperative pathways (range 2.1-4.5). For a major abdominal surgery, total time required was 248.5 min using FCL versus 753.9 min using standard insulin therapy. For a minor abdominal surgery, total time required was 68.6 min and 133.2 min for FCL and standard insulin therapy, respectively. CONCLUSIONS: The use of fully automated closed-loop insulin delivery for inpatient glucose management has the potential to alleviate the workload of diabetes management in an environment with adequately trained staff.


Asunto(s)
Diabetes Mellitus Tipo 1 , Insulina , Humanos , Insulina/uso terapéutico , Hipoglucemiantes/uso terapéutico , Glucemia/metabolismo , Glucosa , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/cirugía , Sistemas de Infusión de Insulina
2.
Diabetes Care ; 46(4): 864-867, 2023 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-36809308

RESUMEN

OBJECTIVE: Continuous glucose monitoring (CGM) may be challenged by extreme conditions during cardiac surgery using hypothermic extracorporeal circulation (ECC). RESEARCH DESIGN AND METHODS: We evaluated the Dexcom G6 sensor in 16 subjects undergoing cardiac surgery with hypothermic ECC, of whom 11 received deep hypothermic circulatory arrest (DHCA). Arterial blood glucose, quantified by the Accu-Chek Inform II meter, served as reference. RESULTS: Intrasurgery mean absolute relative difference (MARD) of 256 paired CGM/reference values was 23.8%. MARD was 29.1% during ECC (154 pairs) and 41.6% immediately after DHCA (10 pairs), with a negative bias (signed relative difference: -13.7%, -26.6%, and -41.6%). During surgery, 86.3% pairs were in Clarke error grid zones A or B and 41.0% of sensor readings fulfilled the International Organization for Standardization (ISO) 15197:2013 norm. Postsurgery, MARD was 15.0%. CONCLUSIONS: Cardiac surgery using hypothermic ECC challenges the accuracy of the Dexcom G6 CGM although recovery appears to occur thereafter.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Diabetes Mellitus Tipo 1 , Humanos , Glucemia , Automonitorización de la Glucosa Sanguínea , Reproducibilidad de los Resultados
3.
Diabetes Care ; 45(9): 2076-2083, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-35880252

RESUMEN

OBJECTIVE: Perioperative management of glucose levels remains challenging. We aimed to assess whether fully closed-loop subcutaneous insulin delivery would improve glycemic control compared with standard insulin therapy in insulin-requiring patients undergoing elective surgery. RESEARCH DESIGN AND METHODS: We performed a single-center, open-label, randomized controlled trial. Patients with diabetes (other than type 1) undergoing elective surgery were recruited from various surgical units and randomly assigned using a minimization schedule (stratified by HbA1c and daily insulin dose) to fully closed-loop insulin delivery with fast-acting insulin aspart (closed-loop group) or standard insulin therapy according to local clinical practice (control group). Study treatment was administered from hospital admission to discharge (for a maximum of 20 days). The primary end point was the proportion of time with sensor glucose in the target range (5.6-10.0 mmol/L). RESULTS: Forty-five patients were enrolled and assigned to the closed-loop (n = 23) or the control (n = 22) group. One patient (closed-loop group) withdrew from the study before surgery and was not analyzed. Participants underwent abdominal (57%), vascular (23%), orthopedic (9%), neuro (9%), or thoracic (2%) surgery. The mean proportion of time that sensor glucose was in the target range was 76.7 ± 10.1% in the closed-loop and 54.7 ± 20.8% in the control group (mean difference 22.0 percentage points [95% CI 11.9; 32.0%]; P < 0.001). No episodes of severe hypoglycemia (<3.0 mmol/L) or hyperglycemia with ketonemia or any study-related adverse events occurred in either group. CONCLUSIONS: In the context of mixed elective surgery, the use of fully closed-loop subcutaneous insulin delivery improves glucose control without a higher risk of hypoglycemia.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Glucemia , Estudios Cruzados , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Glucosa/uso terapéutico , Humanos , Hipoglucemia/inducido químicamente , Hipoglucemiantes/uso terapéutico , Insulina , Sistemas de Infusión de Insulina , Insulina Regular Humana/uso terapéutico , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...