Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
J Vasc Interv Radiol ; 31(12): 2122-2131, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33012647

RESUMEN

PURPOSE: To evaluate the accuracy of cone-beam computed tomography (CT)-based augmented fluoroscopy (AF) image guidance for endobronchial navigation to peripheral lung targets. METHODS: Prototypic endobronchial navigation AF software that superimposed segmented airways, targets, and pathways based on cone-beam CT onto fluoroscopy images was evaluated ex vivo in fixed swine lungs and in vivo in healthy swine (n = 4) without a bronchoscope. Ex vivo and in vivo (n = 3) phase 1 experiments used guide catheters and AF software version 1, whereas in vivo phase 2 (n = 1) experiments also used an endovascular steerable guiding sheath, upgraded AF software version 2, and lung-specific low-radiation-dose protocols. First-pass navigation success was defined as catheter delivery into a targeted airway segment solely using AF, with second-pass success defined as reaching the targeted segment by using updated AF image guidance based on confirmatory cone-beam CT. Secondary outcomes were navigation error, navigation time, radiation exposure, and preliminary safety. RESULTS: First-pass success was 100% (10/10) ex vivo and 19/24 (79%) and 11/15 (73%) for in vivo phases 1 and 2, respectively. Phase 2 second-pass success was 4/4 (100%). Navigation errors were 2.2 ± 1.2 mm ex vivo and 4.9 ± 3.2 mm and 4.0 ± 2.6 mm for in vivo phases 1 and 2, respectively. No major device-related complications were observed in the in vivo experiments. CONCLUSIONS: Endobronchial navigation is feasible and accurate with cone-beam CT-based AF image guidance. AF can guide endobronchial navigation with endovascular catheters and steerable guiding sheaths to peripheral lung targets, potentially overcoming limitations associated with bronchoscopy.


Asunto(s)
Cateterismo/instrumentación , Catéteres , Tomografía Computarizada de Haz Cónico/instrumentación , Pulmón/diagnóstico por imagen , Fantasmas de Imagen , Radiografía Intervencional/instrumentación , Animales , Estudios de Factibilidad , Fluoroscopía/instrumentación , Masculino , Modelos Animales , Interpretación de Imagen Radiográfica Asistida por Computador , Sus scrofa
3.
Innovations (Phila) ; 14(5): 463-467, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31343900

RESUMEN

The Hybrid Operating Room allows the thoracic surgeon to image, biopsy, diagnose, and operate in the same setting. With this streamlined model, time from referral to diagnosis to treatment is reduced. Increased efficiency allows for diagnosis and definitive surgical therapy sooner, thereby improving patient outcomes. A team-based approach is required for this one-stop-shop model of thoracic surgical practice to succeed. We present a series of prospective registry chart reviews demonstrating the utility of same-day diagnosis for thoracic oncology patient outcomes. Of the 21 patients presented, we were able to successfully obtain a diagnosis in 20 patients, resulting in a >95% single-session diagnostic rate.


Asunto(s)
Neoplasias Pulmonares/cirugía , Quirófanos/organización & administración , Adenocarcinoma/diagnóstico , Adenocarcinoma/diagnóstico por imagen , Adenocarcinoma/patología , Adenocarcinoma/cirugía , Broncoscopía/métodos , Carcinoma de Células Escamosas/diagnóstico , Carcinoma de Células Escamosas/diagnóstico por imagen , Carcinoma de Células Escamosas/patología , Carcinoma de Células Escamosas/cirugía , Tomografía Computarizada de Haz Cónico , Femenino , Costos de Hospital , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Masculino , Persona de Mediana Edad , Quirófanos/economía , Quirófanos/métodos , Estudios Prospectivos , Radiografía Intervencional , Factores de Tiempo
5.
J Bronchology Interv Pulmonol ; 25(4): 274-282, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30179922

RESUMEN

BACKGROUND: Electromagnetic navigation bronchoscopy (ENB) has been widely adopted as a guidance technique for biopsy of peripheral lung nodules. However, ENB is limited by the lack of real-time confirmation of the biopsy devices. Intraprocedural cone-beam computed tomography (CBCT) imaging can be utilized to assess or confirm the location of biopsy devices. The aim of this study is to determine the safety and diagnostic yield (DY) of image fusion of intraprocedural CBCT data with live fluoroscopy (augmented fluoroscopy) during ENB-guided biopsy of peripheral lung nodules. METHODS: Data from 75 consecutive patients who underwent biopsy with ENB was collected retrospectively. Patients underwent CBCT imaging while temporarily suspending mechanical ventilation. CBCT data were acquired and 3-dimensional segmentation of nodules was performed using commercially available software (OncoSuite). During ENB, the segmented lesions were projected and fused with live fluoroscopy enabling real-time 3-dimensional guidance. RESULTS: A total of 93 lesions with a median size of 16.0 mm were biopsied in 75 consecutive patients. The overall DY by lesion was 83.7% (95% confidence interval, 74.8%-89.9%). Multivariate regression analysis showed no independent correlation between lesion size, lesion location, lesion visibility under standard fluoroscopy, and the presence of a bronchus sign with DY. Pneumothorax occurred in 3 patients (4%). CONCLUSION: Intraprocedural CBCT imaging with augmented fluoroscopy is feasible and effective and is associated with high DY during ENB-guided biopsies.


Asunto(s)
Broncoscopía/métodos , Tomografía Computarizada de Haz Cónico/métodos , Fluoroscopía/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Anciano , Fenómenos Electromagnéticos , Estudios de Factibilidad , Femenino , Humanos , Pulmón/citología , Pulmón/diagnóstico por imagen , Pulmón/patología , Neoplasias Pulmonares/patología , Masculino , Nódulos Pulmonares Múltiples/diagnóstico por imagen , Nódulos Pulmonares Múltiples/patología , Estadificación de Neoplasias/estadística & datos numéricos , Neoplasias/epidemiología , Neumotórax/complicaciones , Prevalencia , Estudios Retrospectivos , Programas Informáticos
6.
Innovations (Phila) ; 13(5): 372-377, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30119053

RESUMEN

We describe the integration of the hybrid operation room cone-beam computed tomography (CT) scan technology into the practice of general thoracic surgery. The combination of the following three techniques: (1) cone-beam CT scan augmented navigational bronchoscopy, (2) cone-beam CT-guided percutaneous biopsy and/or fiducial placement, and (3) fiducial or image-guided video-assisted thoracic surgery resection, into a single-stage, single-provider procedure allows for diagnosis and treatment in one setting. Rapid on-site evaluation of cytological or pathology specimens is key to this "all-in-one" approach. The time from diagnosis to curative treatment can significantly be reduced using the hybrid operation room technology, leading to decreased upstaging, increased survival and facilitating the otherwise difficult intraoperative detection and resection of small and deeper lesions. Not only does this benefit the overall thoracic healthcare of the community but also provides a cost-effective paradigm for the institution.


Asunto(s)
Broncoscopía , Tomografía Computarizada de Haz Cónico , Biopsia Guiada por Imagen , Quirófanos , Cirugía Torácica Asistida por Video , Análisis Costo-Beneficio , Eficiencia Organizacional , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad
7.
Radiol Med ; 121(8): 675-80, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27138011

RESUMEN

AIM: The aim of the study was to establish if a novel tablet ultrasound (US) may replace a high-end US machine during routine interventional radiology activities. MATERIALS AND METHODS: Thirty consecutive patients were evaluated by two operators comparing the performance of the new US tablet system (VISIQ, Philips Healthcare) against a high-end US system (iU22, Philips Healthcare) using a curved probe (C5-2). A structured questionnaire was used to rank on a 4-point scale the ability of each system to locate a target as detected by previous examinations and visualize needles and path during an interventional procedure. Necessity for conversion from the tablet US to the high-end US system was registered; body mass index (BMI) was annotated for each patient. RESULTS: Agreement between the operators was found for every patient. Mean patient BMI was 25 (range 17-34). Image quality of the tablet US was considered insufficient in 1 case to visualize the target and in another case to visualize the needle. Mean target image quality was superior with the high-end US system, while needle visibility scored higher with the tablet US. Conversion to the high-end system was registered in 40 % of cases: in most cases (66.6 %) the decision was due to the absence of a dedicated needle guide for the tablet US. CONCLUSIONS: The novel tablet US was found to provide sufficient image quality for the majority of routine interventional procedures. Dedicated accessories and additional experience with this new generation US device may be needed to replace bulky high-end US systems.


Asunto(s)
Ultrasonografía Intervencional/instrumentación , Biopsia con Aguja/instrumentación , Índice de Masa Corporal , Ablación por Catéter , Drenaje , Femenino , Humanos , Biopsia Guiada por Imagen/instrumentación , Masculino , Encuestas y Cuestionarios
8.
Artif Organs ; 39(11): 931-8, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25940920

RESUMEN

The blood pressure changes induced by the intra-aortic balloon pump (IABP) are expected to create clinical improvement in terms of coronary perfusion and myocardial oxygen consumption. However, the measured effects reported in literature are inconsistent. The aim of this study was to investigate the influence of ischemia on IABP efficacy in healthy hearts and in shock. Twelve slaughterhouse porcine hearts (hearts 1-12) were connected to an external circulatory system, while physiologic cardiac performance was restored. Different clinical scenarios, ranging from healthy to cardiogenic shock, were simulated by step-wise administration of negative inotropic drugs. In hearts 7-12, severe global myocardial ischemia superimposed upon the decreased contractile states was created. IABP support was applied in all hearts under all conditions. Without ischemia, the IABP induced a mild increase in coronary blood flow and cardiac output. These effects were strongly augmented in the presence of persisting ischemia, where coronary blood flow increased by 49 ± 24% (P < 0.01) and cardiac output by 17 ± 6% (P < 0.01) in case of severe pump failure. As expected, myocardial oxygen consumption increased in case of ischemia (21 ± 17%; P < 0.01), while it slightly decreased without (-3 ± 6%; P < 0.01). In case of progressive pump failure due to persistent myocardial ischemia, the IABP increased hyperemic coronary blood flow and cardiac output significantly, and reversed the progressive hemodynamic deterioration within minutes. This suggests that IABP therapy in acute myocardial infarction is most effective in patients with viable myocardium, suffering from persistent myocardial ischemia, despite adequate epicardial reperfusion.


Asunto(s)
Corazón/fisiología , Contrapulsador Intraaórtico/métodos , Isquemia Miocárdica/fisiopatología , Animales , Presión Sanguínea/fisiología , Circulación Coronaria/fisiología , Falla de Equipo , Hemodinámica/fisiología , Miocardio/metabolismo , Consumo de Oxígeno , Porcinos
9.
EuroIntervention ; 11(8): 905-13, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25136887

RESUMEN

AIMS: The aim of this study was to compare the hyperaemic effect of a single bolus regadenoson injection to a central venous adenosine infusion for inducing hyperaemia in the measurement of fractional flow reserve (FFR). METHODS AND RESULTS: One hundred patients scheduled for FFR measurement were enrolled. FFR was first measured by IV adenosine (140 µg/kg/min), thereafter by IV bolus regadenoson injection (400 µg), followed by another measurement by IV adenosine and bolus injection of regadenoson. The regadenoson injections were randomised to central or peripheral intravenous. Hyperaemic response and duration of steady state maximum hyperaemia were studied, central versus peripheral venous regadenoson injections were compared, and safety and reproducibility of repeated injections were investigated. Mean age was 66±8 years, 75% of the patients were male. The target stenosis was located in the LM, LAD, LCX, and RCA in 7%, 54%, 20% and 19%, respectively. There was no difference in FFR measured by adenosine or by regadenoson (ΔFFR=0.00±0.01, r=0.994, p<0.001). Duration of maximum hyperaemia after regadenoson was variable (10-600 s). No serious side effects of either drug were observed. CONCLUSIONS: Maximum coronary hyperaemia can be achieved easily, rapidly, and safely by one single intravenous bolus of regadenoson administered either centrally or peripherally. Repeated regadenoson injections are safe. The hyperaemic plateau is variable. Clinical Trial Registration: http://clinicaltrials.gov/ct2/ show/study/NCT01809743?term=NCT01809743&rank=1 (ClinicalTrials.gov Identifier: NCT01809743).


Asunto(s)
Cateterismo Cardíaco , Estenosis Coronaria/diagnóstico , Reserva del Flujo Fraccional Miocárdico , Hiperemia/fisiopatología , Purinas/administración & dosificación , Pirazoles/administración & dosificación , Vasodilatadores/administración & dosificación , Anciano , Cateterismo Venoso Central , Cateterismo Periférico , Angiografía Coronaria , Estenosis Coronaria/fisiopatología , Femenino , Humanos , Infusiones Intravenosas , Inyecciones Intravenosas , Masculino , Persona de Mediana Edad , Países Bajos , Valor Predictivo de las Pruebas , Purinas/efectos adversos , Pirazoles/efectos adversos , Reproducibilidad de los Resultados , Vasodilatadores/efectos adversos
10.
EuroIntervention ; 11(3): 286-92, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25254356

RESUMEN

AIMS: This substudy investigated IABP support in large STEMI complicated by persistent ischaemia within the original CRISP-AMI trial. METHODS AND RESULTS: Patients were included if the ECG at admission showed summed ST deviation (ST-D) ≥15 mm and the ECG post PCI showed poor ST resolution (<50%). Endpoints evaluated were all-cause mortality at six months and the composite endpoint of death, cardiogenic shock or new or worsening heart failure at six months. One hundred and forty-nine patients had ST-D ≥15 mm (mean ST-D 24±8 mm). Of these patients, 36 (24%) showed poor ST resolution (15 patients in the IABP group; 21 patients in the control group). Mean age was 55±11 years, 89% were male. Mean systolic and diastolic blood pressures were 135±31 mmHg and 83±22 mmHg, respectively. The left anterior descending coronary artery was the infarct-related artery in all cases, primary PCI was successful in 94%. At six months, zero patients in the IABP group died versus five patients in the control group (0% versus 24%; p=0.046). There was a trend towards statistical significance in the composite endpoint (one patient [7%] versus seven patients [33%]; p=0.06). CONCLUSIONS: In this substudy, use of IABP was associated with decreased six-month mortality in large STEMI complicated by persistent ischaemia after PCI.


Asunto(s)
Contrapulsador Intraaórtico , Isquemia/mortalidad , Infarto del Miocardio/mortalidad , Infarto del Miocardio/cirugía , Choque Cardiogénico/mortalidad , Choque Cardiogénico/cirugía , Adulto , Anciano , Aorta , Femenino , Humanos , Isquemia/complicaciones , Isquemia/terapia , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Riesgo , Choque Cardiogénico/complicaciones , Resultado del Tratamiento
11.
Med Eng Phys ; 36(10): 1288-95, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25066581

RESUMEN

Continuous flow left ventricular assist devices (CF-LVADs) reduce arterial pulsatility, which may cause long-term complications in the cardiovascular system. The aim of this study is to improve the pulsatility by driving a CF-LVAD at a varying speed, synchronous with the cardiac cycle in an ex-vivo experiment. A Micromed DeBakey pump was used as CF-LVAD. The heart was paced at 140 bpm to obtain a constant cardiac cycle for each heartbeat. First, the CF-LVAD was operated at a constant speed. At varying-speed CF-LVAD assistance, the pump was driven such that the same mean pump output was generated. For synchronization purposes, an algorithm was developed to trigger the CF-LVAD each heartbeat. The pump flow rate was selected as the control variable and a reference model was used for regulating the CF-LVAD speed. Continuous and varying-speed CF-LVAD assistance provided the same mean arterial pressure and flow rate, while the index of pulsatility doubled in both arterial pressure and pump flow rate signals under pulsatile pump speed support. This study shows the possibility of improving the pulsatility in CF-LVAD support by regulating pump speed over a cardiac cycle without compromising the overall level of support.


Asunto(s)
Arterias/fisiología , Retroalimentación , Corazón Auxiliar , Flujo Pulsátil , Algoritmos , Aorta/fisiología , Presión Sanguínea , Frecuencia Cardíaca
12.
Artif Organs ; 37(8): 724-30, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23489228

RESUMEN

The isolated beating pig heart model is an accessible platform to investigate the coronary circulation in its truly morphological and physiological state, whereas its use is beneficial from a time, cost, and ethical perspective. However, whether the coronary autoregulation is still intact is not known. Here, we study the autoregulation of coronary blood flow in the working isolated pig heart in response to brief occlusions of the coronary artery, to step-wise changes in left ventricular loading conditions and contractile states, and to pharmacologic vasodilating stimuli. Six slaughterhouse pig hearts (473 ± 40 g) were isolated, prepared, and connected to an external circulatory system. Through coronary reperfusion and controlled cardiac loading, physiological cardiac performance was achieved. After release of a coronary occlusion, coronary blood flow rose rapidly to an equal (maximum) level as the flow during control beats, independent of the duration of occlusion. Moreover, a linear relation was found between coronary blood flow and coronary driving pressure for a wide variation of preload, afterload, and contractility. In addition, intracoronary administration of papaverine did not yield a transient increase in blood flow indicating the presence of maximum coronary hyperemia. Together, this indicates that the coronary circulation in the isolated beating pig heart is in a permanent state of maximum hyperemia. This makes the model excellently suitable for testing and validating cardiovascular devices (i.e., heart valves, stent grafts, and ventricular assist devices) under well-controlled circumstances, whereas it decreases the necessity of sacrificing large mammalians for performing classical animal experiments.


Asunto(s)
Circulación Coronaria , Vasos Coronarios/fisiología , Corazón/fisiología , Homeostasis , Animales , Hemodinámica , Porcinos
13.
ASAIO J ; 59(1): 30-6, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23263334

RESUMEN

Because of the large number of interaction factors involved, the effects of the intra-aortic balloon pump (IABP) have not been investigated deeply. To enhance its clinical efficiency and to better define indications for use, advanced models are required to test the interaction between the IABP and the cardiovascular system. A patient with mild blood pressure depression and a lowered cardiac output is modeled in a lumped parameter computational model, developed with physiologically representative elements for relevant components of circulation and device. IABP support is applied, and the moments of balloon inflation and deflation are varied around their conventional timing modes. For validation purposes, timing is adapted within acceptable ranges in ten patients undergoing IABP therapy for typical clinical indications. In both model and patients, the IABP induces a diastolic blood pressure augmentation as well as a systolic reduction in afterload. The support capabilities of the IABP benefit the most when the balloon is deflated simultaneously with ventricular contraction, whereas inflation before onset of diastole unconditionally interferes with ejection. The physiologic response makes the model an excellent tool for testing the interaction between the IABP and the cardiovascular system, and how alterations of specific IABP parameters (i.e., timing) affect this coupling.


Asunto(s)
Sistema Cardiovascular/fisiopatología , Contrapulsador Intraaórtico/instrumentación , Modelos Cardiovasculares , Adulto , Anciano , Anciano de 80 o más Años , Simulación por Computador , Femenino , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Contracción Miocárdica
14.
Artif Organs ; 35(9): 893-901, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21819436

RESUMEN

The Impella 2.5 left percutaneous (LP), a relatively new transvalvular assist device, challenges the position of the intra-aortic balloon pump (IABP), which has a long record in supporting patients after myocardial infarction and cardiac surgery. However, while more costly and more demanding in management, the advantages of the Impella 2.5 LP are yet to be established. The aim of this study was to evaluate the benefits of the 40 cc IABP and the Impella 2.5 LP operating at 47,000 rpm in vitro, and compare their circulatory support capabilities in terms of cardiac output, coronary flow, cardiac stroke work, and arterial blood pressure. Clinical scenarios of cardiogenic preshock and cardiogenic shock (CS), with blood pressure depression, lowered cardiac output, and constant heart rate of 80 bpm, were modeled in a model-controlled mock circulation, featuring a systemic, pulmonary, and coronary vascular bed. The ventricles, represented by servomotor-operated piston pumps, included the Frank-Starling mechanism. The systemic circulation was modeled with a flexible tube having close-to-human aortic dimensions and compliance properties. Proximally, it featured a branch mimicking the brachiocephalic arteries and a physiological correct coronary flow model. The rest of the systemic and pulmonary impedance was modeled by four-element Windkessel models. In this system, the enhancement of coronary flow and blood pressure was tested with both support systems under healthy and pathological conditions. Hemodynamic differences between the IABP and the Impella 2.5 LP were small. In our laboratory model, both systems approximately yielded a 10% cardiac output increase and a 10% coronary flow increase. However, since the Impella 2.5 LP provided significantly better left ventricular unloading, the circulatory support capabilities were slightly in favor of the Impella 2.5 LP. On the other hand, pulsatility was enhanced with the IABP and lowered with the Impella 2.5 LP. The support capabilities of both the IABP and the Impella 2.5 LP strongly depended on the simulated hemodynamic conditions. Maximum hemodynamic benefits were achieved when mechanical circulatory support was applied on a simulated scenario of deep CS.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Corazón Auxiliar , Contrapulsador Intraaórtico , Choque Cardiogénico/cirugía , Gasto Cardíaco , Hemodinámica , Humanos , Modelos Biológicos , Choque Cardiogénico/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...