Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Front Cardiovasc Med ; 11: 1362903, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38628316

RESUMEN

Background: Obesity is a risk factor for atrial fibrillation (AF). Data regarding left atrial (LA) remodeling in obese patients are scarce. Whether obesity favors AF recurrence after catheter ablation (CA) is still controversial. We assessed the distribution of epicardial atrial fat on computed tomography (CT), LA bipolar voltage, low-voltage zone (LVZ) extent, and the outcome of voltage-guided ablation of persistent AF in obese and non-obese patients. Methods: A total of 139 patients with persistent AF undergoing a first voltage-guided ablation were enrolled and divided into two groups: 74 were non-obese and 65 were obese. Epicardial adipose tissue (EAT) was assessed on a CT scanner. LA endocardial voltage maps were obtained using a 3D mapping system in sinus rhythm. LVZ was defined as a bipolar peak-to-peak voltage amplitude <0.5 mV. Results: LA volume, voltage, and EAT amount were similar in the two groups. LVZ was less frequent in obese patients [12 (18.8%) vs. 26 (35.1%), p = 0.05], particularly on the anterior wall. The posterior and lateral EATs were correlated with posterior and lateral LVZ extent, respectively, in obese patients. After 36 months of follow-up, the AF-free survival rate was similar. Lateral EAT [odds ratio (OR) 1.21, 95% confidence interval (CI) 1-1.4, p = 0.04] and P-wave duration (OR 1.03, 95% CI 1-1.05, p = 0.03), but not body mass index (BMI), were predictors of AF recurrence after CA. Conclusion: In obese patients, LVZ was less marked than in non-obese patients with similar LA volumes, voltage, and EAT amounts. In obese patients, posterior and lateral EATs were correlated with posterior and lateral LVZ extents. Obese patients had a similar and favorable 36-month outcome after AF ablation. BMI was not predictive of AF recurrence.

2.
Front Cardiovasc Med ; 10: 1229345, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37692044

RESUMEN

Background: Gender-related differences have been reported in atrial fibrotic remodeling and prognosis of atrial fibrillation (AF) patients after ablation. We assessed in persistent AF the regional distribution of left atrial (LA) bipolar voltage and the extent of low-voltage zones (LVZ) according to gender as well as the results of a voltage-guided substrate ablation. Methods: Consecutive patients who underwent a voltage-guided AF ablation were enrolled. LA endocardial voltage maps were obtained using a 3D electro-anatomical mapping system in sinus rhythm. LVZ was defined as <0.5 mV. Results: A total of 115 patients were enrolled (74 men, 41 women). The LA bipolar voltage amplitude was twice lower in the whole LA (p < 0.01) and in each atrial region in women compared with men, whereas the LA indexed volume was similar. LVZ were found in 56.1% of women and 16.2% of men (p < 0.01). LVZ were also more extensive in women (p = 0.01), especially in the anterior LA. Atrial voltage alteration occurred earlier in women than in men. In a multivariate analysis, the female sex (OR 12.99; 95% CI, 3.23-51.63, p = 0.0001) and LA indexed volume (OR 1.09; 95% CI, 1.04-1.16, p = 0.001) were predictive of LVZ. Atrial arrhythmia-free survival was similar in men and women 36 months after a single ablation procedure. Conclusion: The study reports a strong relationship between the female gender and atrial substrate remodeling. The female gender was significantly associated with higher incidence, earlier occurrence, and greater extent of LVZ compared with men. Despite the female-specific characteristics in atrial remodeling, LVZ-guided ablation may improve the AF ablation outcome in women.

3.
J Am Coll Cardiol ; 82(7): 590-599, 2023 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-37558371

RESUMEN

BACKGROUND: Very few data have been published on the use of subcutaneous implantable cardioverter-defibrillators (S-ICDs) in patients with congenital heart disease (CHD). OBJECTIVES: The aim of this study was to analyze outcomes associated with S-ICDs in patients with CHD. METHODS: This nationwide French cohort including all patients with an S-ICD was initiated in 2020 by the French Institute of Health and Medical Research. Characteristics at implantation and outcomes were analyzed in patients with CHD. RESULTS: From October 12, 2012, to December 31, 2019, among 4,924 patients receiving an S-ICD implant in 150 centers, 101 (2.1%) had CHD. Tetralogy of Fallot, univentricular heart, and dextro-transposition of the great arteries represented almost one-half of the population. Patients with CHD were significantly younger (age 37.1 ± 15.4 years vs 50.1 ± 14.9 years; P < 0.001), more frequently female (37.6% vs 23.0%; P < 0.001), more likely to receive an S-ICD for secondary prevention (72.3% vs 35.9%; P < 0.001), and less likely to have severe systolic dysfunction of the systemic ventricle (28.1% vs 53.1%; P < 0.001). Over a mean follow-up period of 1.9 years, 16 (15.8%) patients with CHD received at least 1 appropriate shock, with all shocks successfully terminating the ventricular arrhythmia. The crude risk of appropriate S-ICD shock was twice as high in patients with CHD compared with non-CHD patients (annual incidences of 9.0% vs 4.4%; HR: 2.1; 95% CI: 1.3-3.4); however, this association was no longer significant after propensity matching (especially considering S-ICD indication, P = 0.12). The burden of all complications (HR: 1.2; 95% CI: 0.7-2.1; P = 0.4) and inappropriate shocks (HR: 0.9; 95% CI: 0.4-2.0; P = 0.9) was comparable in both groups. CONCLUSIONS: In this nationwide study, patients with CHD represented 2% of all S-ICD implantations. Our findings emphasize the effectiveness and safety of S-ICD in this particularly high-risk population. (S-ICD French Cohort Study [HONEST]; NCT05302115).


Asunto(s)
Desfibriladores Implantables , Cardiopatías Congénitas , Transposición de los Grandes Vasos , Humanos , Femenino , Adulto Joven , Adulto , Persona de Mediana Edad , Desfibriladores Implantables/efectos adversos , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/etiología , Estudios de Cohortes , Resultado del Tratamiento , Estudios Retrospectivos , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/terapia
4.
J Cardiovasc Electrophysiol ; 33(4): 731-737, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35138039

RESUMEN

INTRODUCTION: The aim of this study was to assess the safety and efficacy of the TightRail™ sheath for pacemaker/defibrillator transvenous lead extraction (TLE). METHODS: Multicenter observational study including patients who underwent a TLE with the TightRail™ sheath in five French university hospitals from September 2014 to January 2020. RESULTS: Two hundred and twenty-five patients (76% males, 71 ± 12 years) underwent a TLE procedure with the TightRail™. A total of 438 leads were extracted using the TightRail™, and the mean age of the extracted leads was 128 ± 85 months; of these, 344 (79%) were pacing leads and 94 (21%) were implantable cardioverter defibrillator leads. The overall clinical success of the extraction procedures was 93%. Overall, 410 of the 438 leads (95%) were extracted (complete or incomplete removal). After multilevel mixed-effects logistic regression model, we found that lead age (odds ratio [OR], 95% confidence interval [CI] for a 1 year increase: 1.11 [1.07-1.15], p < .001) and number of leads extracted (OR, 95% CI: 2.09 [1.50-2.96], p < .001) were the two independent factors associated with complete lead removal failure. Finally, there were 7 (3%) cases of major complications but no per-procedural death. CONCLUSION: This is the first large-scale survey assessing the efficacy and safety profile of the Tightrail™ mechanical sheath. The clinical success rate was 93%, and the lead removal failure was dependent on the age and number of leads. We show a satisfactory safety profile in this cohort of patients from primarily low-volume centers with older leads.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Remoción de Dispositivos/efectos adversos , Femenino , Humanos , Masculino , Estudios Retrospectivos , Resultado del Tratamiento
5.
Eur Heart J Case Rep ; 4(6): 1-4, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33447717

RESUMEN

BACKGROUND: Since the onset of the COVID-19 pandemic, several cardiovascular manifestations have been described. Among them, venous thromboembolism (VTE) seems to be one of the most frequent, particularly in intensive care unit patients. We report two cases of COVID-19 patients developing acute pulmonary embolism (PE) after discharge from a first hospitalization for pneumonia of moderate severity. CASE SUMMARY: Two patients with positive RT-PCR test were initially hospitalized for non-severe COVID-19. Both received standard thromboprophylaxis during the index hospitalization and had no strong predisposing risk factors for VTE. Few days after discharge, they were both readmitted for worsening dyspnoea due to PE. One patient was positive for lupus anticoagulant. DISCUSSION: Worsening respiratory status in COVID-19 patients must encourage physicians to search for PE since SARS-CoV-2 infection may act as a precipitant risk factor for VTE. Patients may thus require more aggressive and longer thromboprophylaxis after COVID-19 related hospitalization.