Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Eur Radiol ; 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38480567

RESUMEN

OBJECTIVES: Aim of this study was to assess the value of virtual non-contrast (VNC) reconstructions in differentiating between adrenal adenomas and metastases on a photon-counting detector CT (PCD-CT). MATERIAL AND METHODS: Patients with adrenal masses and contrast-enhanced CT scans in portal venous phase were included. Image reconstructions were performed, including conventional VNC (VNCConv) and PureCalcium VNC (VNCPC), as well as virtual monochromatic images (VMI, 40-90 keV) and iodine maps. We analyzed images using semi-automatic segmentation of adrenal lesions and extracted quantitative data. Logistic regression models, non-parametric tests, Bland-Altman plots, and a random forest classifier were used for statistical analyses. RESULTS: The final study cohort consisted of 90 patients (36 female, mean age 67.8 years [range 39-87]) with adrenal lesions (45 adenomas, 45 metastases). Compared to metastases, adrenal adenomas showed significantly lower CT-values in VNCConv and VNCPC (p = 0.007). Mean difference between VNC and true non-contrast (TNC) was 17.67 for VNCConv and 14.85 for VNCPC. Random forest classifier and logistic regression models both identified VNCConv and VNCPC as the best discriminators. When using 26 HU as the threshold in VNCConv reconstructions, adenomas could be discriminated from metastases with a sensitivity of 86.7% and a specificity of 75.6%. CONCLUSION: VNC algorithms overestimate CT values compared to TNC in the assessment of adrenal lesions. However, they allow a reliable discrimination between adrenal adenomas and metastases and could be used in clinical routine in near future with an increased threshold (e.g., 26 HU). Further (multi-center) studies with larger patient cohorts and standardized protocols are required. CLINICAL RELEVANCE STATEMENT: VNC reconstructions overestimate CT values compared to TNC. Using a different threshold (e.g., 26 HU compared to the established 10 HU), VNC has a high diagnostic accuracy for the discrimination between adrenal adenomas and metastases. KEY POINTS: • Virtual non-contrast reconstructions may be promising tools to differentiate adrenal lesions and might save further diagnostic tests. • The conventional and a new calcium-preserving virtual non-contrast algorithm tend to systematically overestimate CT-values compared to true non-contrast images. • Therefore, increasing the established threshold for true non-contrast images (e.g., 10HU) may help to differentiate between adrenal adenomas and metastases on contrast-enhanced CT.

2.
Int J Cardiovasc Imaging ; 40(4): 723-732, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38175389

RESUMEN

The aim of our study was to evaluate two different virtual non-contrast (VNC) algorithms applied to photon counting detector (PCD)-CT data in terms of noise, effectiveness of contrast media subtraction and aortic valve calcium (AVC) scoring compared to reference true non-contrast (TNC)-based results. Consecutive patients underwent TAVR planning examination comprising a TNC scan, followed by a CTA of the heart. VNC series were reconstructed using a conventional (VNCconv) and a calcium-preserving (VNCpc) algorithm. Noise was analyzed by means of the standard deviation of CT-values within the left ventricle. To assess the effectiveness of contrast media removal, heart volumes were segmented and the proportion of their histograms > 130HU was taken. AVC was measured by Agatston and volume score. 41 patients were included. Comparable noise levels to TNC were achieved with all VNC reconstructions. Contrast media was effectively virtually removed (proportions > 130HU from 81% to < 1%). Median calcium scores derived from VNCconv underestimated TNC-based scores (up to 74%). Results with smallest absolute difference to TNC were obtained with VNCpc reconstructions (0.4 mm, Br36, QIR 4), but with persistent significant underestimation (median 29%). Both VNC algorithms showed near-perfect (r²>0.9) correlation with TNC. Thin-slice VNC reconstructions provide equivalent noise levels to standard thick-slice TNC series and effective virtual removal of iodinated contrast. AVC scoring was feasible on both VNC series, showing near-perfect correlation, but with significant underestimation. VNCpc with 0.4 mm slices and Br36 kernel at QIR 4 gave the most comparable results and, with further advances, could be a promising replacement for additional TNC.


Asunto(s)
Algoritmos , Estenosis de la Válvula Aórtica , Válvula Aórtica , Válvula Aórtica/patología , Calcinosis , Angiografía por Tomografía Computarizada , Tomografía Computarizada Multidetector , Valor Predictivo de las Pruebas , Interpretación de Imagen Radiográfica Asistida por Computador , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Femenino , Anciano , Masculino , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Reproducibilidad de los Resultados , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Calcinosis/diagnóstico por imagen , Medios de Contraste/administración & dosificación
3.
Abdom Radiol (NY) ; 49(1): 103-116, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37796327

RESUMEN

PURPOSE: To analyze the conspicuity of pancreatic ductal adenocarcinoma (PDAC) in virtual monoenergetic images (VMI) on a novel photon-counting detector CT (PCD-CT) in comparison to energy-integrating CT (EID-CT). METHODS: Inclusion criteria comprised initial diagnosis of PDAC (reference standard: histopathological analysis) and standardized contrast-enhanced CT imaging either on an EID-CT or a PCD-CT. Patients were excluded due to different histopathological diagnosis or missing tumor delineation on CT. On the PCD-CT, 40-190 keV VMI reconstructions were generated. Image noise, tumor-to-pancreas ratio (TPR) and contrast-to-noise ratio (CNR) were analyzed by ROI-based measurements in arterial and portal venous contrast phase. Two board-certified radiologist evaluated image quality and tumor delineation at both, EID-CT and PCD-CT (40 and 70 keV). RESULTS: Thirty-eight patients (mean age 70.4 years ± 10.3 [range 45-91], 27 males; PCD-CT: n=19, EID-CT: n=19) were retrospectively included. On the PCD-CT, tumor conspicuity (reflected by low TPR and high CNR) was significantly improved at low-energy VMI series (≤ 70 keV compared to > 70 keV), both in arterial and in portal venous contrast phase (P < 0.001), reaching the maximum at 40 keV. Comparison between PCD-CT and EID-CT showed significantly higher CNR on the PCD-CT in portal venous contrast phase at < 70 keV (P < 0.016). On the PCD-CT, tumor conspicuity was improved in portal venous contrast phase compared to arterial contrast phase especially at the lower end of the VMI spectrum (≤ 70 keV). Qualitative analysis revealed that tumor delineation is improved in 40 keV reconstructions compared to 70 keV reconstructions on a PCD-CT. CONCLUSION: PCD-CT VMI reconstructions (≤ 70 keV) showed significantly improved conspicuity of PDAC in quantitative and qualitative analysis in both, arterial and portal venous contrast phase, compared to EID-CT, which may be important for early detection of tumor tissue in clinical routine. Tumor delineation was superior in portal venous contrast phase compared to arterial contrast phase.


Asunto(s)
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Imagen Radiográfica por Emisión de Doble Fotón , Masculino , Humanos , Anciano , Estudios Retrospectivos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Relación Señal-Ruido , Tomografía Computarizada por Rayos X/métodos , Neoplasias Pancreáticas/diagnóstico por imagen , Carcinoma Ductal Pancreático/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
4.
Eur J Radiol ; 168: 111125, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37804649

RESUMEN

PURPOSE: Aim of this study was to determine which virtual non-contrast (VNC) reconstruction algorithm, applied to which contrast phase of computed tomography angiography, best matches true non-contrast (TNC) images in the assessment of active bleeding. METHOD: Patients who underwent a triphasic scan (pre-contrast, arterial, portal venous contrast) on a photon-counting detector CT (PCD-CT) (120 kV, image quality level 68) with suspected active (tumor, postoperative, spontaneous or other) bleeding were retrospectively included in this study. Conventional (VNCConv) and a calcium-preserving VNC algorithm (VNCPC) were derived from both arterial (art) and portal venous (pv) contrast scans, and analyzed quantitatively and qualitatively by two independent and blinded raters. RESULTS: 40 patients (22 female, mean age 76 years) were included. Measurements of CT values showed significant albeit small differences between TNC and VNC for most analyzed tissue regions without clear superiority of a VNC algorithm or contrast phase (e.g. ΔHU fat TNC to VNCPCpv 3.1 HU). However, qualitative analysis showed a preference to VNCPCpv in terms of image quality (on a 5-point Likert scale VNCConvart = 3.5 ± 0.8, VNCPCart = 3.7 ± 0.7, VNCConvpv = 3.7 ± 0.7, VNCPCpv = 3.8 ± 0.7) and residual calcium contrast (VNCConvart = 3.0 ± 0.8, VNCPCart = 3.5 ± 0.7, VNCConvpv = 3.6 ± 0.7, VNCPCpv = 3.9 ± 0.6). CONCLUSIONS: When multiple post-contrast phases are available, VNCPC series based on portal venous phase are the most suitable replacement for an additional pre-contrast scan, with the prospect of a significant reduction in patient radiation dose.


Asunto(s)
Calcio , Tomografía Computarizada por Rayos X , Humanos , Femenino , Anciano , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Angiografía por Tomografía Computarizada/métodos , Hemorragia , Algoritmos
5.
Cardiovasc Intervent Radiol ; 46(10): 1385-1393, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37700006

RESUMEN

PURPOSE: To investigate differences in thermal sensitivity of virtual monoenergetic imaging (VMI) series generated from photon-counting detector (PCD) CT data sets, regarding their use to improve discrimination of the ablation zone during percutaneous cryoablation. MATERIALS AND METHODS: CT-guided cryoablation was performed using an ex vivo model of porcine liver on a PCD-CT system. The ablation zone was imaged continuously for 8 min by acquiring a CT scan every 5 s. Tissue temperature was measured using fiberoptic temperature probes placed parallel to the cryoprobe. CT-values and noise were measured at the tip of the temperature probes on each scan and on VMI series from 40 to 130 keV. Correlation of CT-values and temperature was assessed using linear regression analyses. RESULTS: For the whole temperature range of [- 40, + 20] °C, we observed a linear correlation between CT-values and temperature in reference 70 keV images (R2 = 0.60, p < 0.001) with a thermal sensitivity of 1.4HU/°C. For the most dynamic range of [- 15, + 20] °C, the sensitivity increased to 2.4HU/°C (R2 = 0.50, p < 0.001). Using VMI reconstructions, the thermal sensitivity increased from 1.4 HU/°C at 70 keV to 1.5, 1.7 and 2.0HU/°C at 60, 50 and 40 keV, respectively (range [- 40, + 20] °C). For [- 15, + 20]°C, the thermal sensitivity increased from 2.4HU/°C at 70 keV to 2.5, 2.6 and 2.7HU/°C at 60, 50 and 40 keV, respectively. Both CT-values and noise also increased with decreasing VMI keV-levels. CONCLUSION: During CT-guided cryoablation of porcine liver, low-keV VMI reconstructions derived from PCD-CT data sets exhibit improved thermal sensitivity being highest between + 20 and - 15 °C.


Asunto(s)
Criocirugía , Porcinos , Animales , Relación Señal-Ruido , Tomografía Computarizada por Rayos X/métodos , Hígado/diagnóstico por imagen , Hígado/cirugía , Abdomen , Estudios Retrospectivos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
6.
BMC Gastroenterol ; 23(1): 300, 2023 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-37674195

RESUMEN

BACKGROUND: Aim of this study was to analyze long-term trends of hospitalizations, treatment regimen and in-hospital mortality of in-patients with acute mesenteric ischemia (AMI) over the past decade and effects of the SARS-CoV2-pandemic. METHODS: We analyzed fully anonymized data from the German Federal Statistical Office of patients with AMI between 2010 and 2020. Besides descriptive analyses of age, gender, in-hospital mortality, comorbidity burden and treatment regimen, multivariable logistic regression analyses were performed to identify independent variables associated with in-hospital mortality and different treatment. RESULTS: A total of 278,121 hospitalizations (120,667 male [43.4%], mean age 72.1 years) with AMI were included in this study. The total number of hospitalizations increased from 2010 (n = 24,172) to 2019 (n = 26,684) (relative increase 10.4%). In-hospital mortality decreased over the past decade from 36.6% to 2010 to 31.1% in 2019 (rel. decrease 15.2%). Independent risk factors for in-hospital mortality were older age (OR = 1.03 per year), higher comorbidity burden (OR = 1.06 per point in van Walraven score [vWs]), male gender (OR = 1.07), AMI as a secondary diagnosis (OR = 1.44), and the need for surgical (visceral surgery: OR = 1.38, vascular surgery: OR = 3.33) and endovascular treatment (OR = 1.21). We report a decline in hospitalizations during the first wave of infection in spring 2020 (rel. decrease 9.7%). CONCLUSION: In-hospital mortality rate has declined over the past decade, but remains high at above 30%. Older age, increased comorbidity and male gender are independent factors for in-hospital mortality. Hospitalizations requiring vascular surgery are associated with high in-hospital mortality, followed by visceral surgery and endovascular approaches. The first wave of the SARS-CoV2-pandemic in spring 2020 implied a decrease in hospital admissions.


Asunto(s)
COVID-19 , Isquemia Mesentérica , Humanos , Masculino , Anciano , Isquemia Mesentérica/epidemiología , Isquemia Mesentérica/cirugía , ARN Viral , COVID-19/epidemiología , SARS-CoV-2 , Mortalidad Hospitalaria
7.
CVIR Endovasc ; 6(1): 44, 2023 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-37642825

RESUMEN

PURPOSE: Aim of this study was to analyze hospitalizations due to ruptured and non-ruptured abdominal aortic aneurysms (rAAA, nrAAA) in Germany between 2005 and 2021 to determine long-term trends in treatment and the impact of the SARS-CoV-2 pandemic. MATERIALS AND METHODS: Fully anonymized data were available from the research data center (RDC) of the German Federal Statistical Office (Destatis). All German hospitalizations with the ICD-10 code "I71.3, rAAA" and "I71.4, nrAAA" in 2005 and 2010-2021 were analyzed. RESULTS: We report data of a total of 202,951 hospitalizations. The number of hospitalizations increased from 2005 to 2019 (14,075 to 16,051, + 14.0%). The rate of open repair (OR) constantly decreased, whereas the rate of endovascular aortic repair (EVAR) increased until 2019. During the pandemic, the number of hospitalizations due to nrAAA dropped from 13,887 (86.5%) in 2019 to 11,278 (85.0%) in 2021. The strongest decrease of hospitalizations for AAA was observed during the first wave of the SARS-CoV-2-pandemic in spring 2020 (-25.5%). CONCLUSION: Over the past decades, we observed an increasing number of hospitalizations due to AAA accompanied by a shift from OR to EVAR especially for nrAAA. During the lockdown measures due to the SARS-CoV-2-pandemic, a decrease in hospitalizations for nrAAA (but not for rAAA) was shown in 2020 and furthermore in 2021 with no rebound of treatment of nrAAA suggesting an accumulation of untreated AAA with a potentially increased risk of rupture.

8.
Eur J Radiol ; 165: 110946, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37399668

RESUMEN

PURPOSE: To investigate the usefulness of virtual monoenergetic image (VMI) reconstructions derived from scans on a novel photon-counting detector CT (PCD-CT) for artifact reduction in patients after posterior spinal fixation. METHODS: This retrospective cohort study included 23 patients status post posterior spinal fixation. Subjects were scanned on a novel PCD-CT (NAEOTOM Alpha, Siemens Healthineers, Erlangen, Germany) as part of routine clinical care. 14 sets of VMI reconstructions were derived in 10 keV increments for the interval 60-190 keV. The mean and the standard deviation (SD) of CT-values in 12 defined locations around a pair of pedicle screws on one vertebral level and the SD of homogenous fat were measured and used to calculate an artifact index (AIx). RESULTS: Averaged over all regions, the lowest AIx was observed at VMI levels of 110 keV (32.5 (27.8-37.9)) which was significantly different from those of VMIs ≤ 90 keV (p < 0.001) or ≥160 keV (p < 0.015), respectively. Overall AIx values increased in both lower- and higher-keV levels. Regarding individual locations, either a monotonous AIx-decrease for increasing keV values or an AIx-minimum in intermediate-keV levels (100-140 keV) was found. In locations adjacent to larger metal parts, the increase of AIx values at the high-end of the keV spectrum was mainly explained by a reappearance of streak artifacts. CONCLUSION: Our findings suggest that 110 keV is the optimal VMI setting for overall artifact suppression. In specific anatomical regions, however, slight adjustments towards higher-keV levels may provide better results.


Asunto(s)
Artefactos , Tomografía Computarizada por Rayos X , Humanos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Columna Vertebral/diagnóstico por imagen , Columna Vertebral/cirugía , Metales , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Relación Señal-Ruido
9.
Eur J Radiol ; 166: 110967, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37487433

RESUMEN

PURPOSE: To correlate CT values of the blood pool on VNC series with serum hemoglobin values for the detection of anemia in oncologic patients undergoing contrast-enhanced PCD-CT scans. METHODS: This prospective study (NCT04989192) included consecutive oncologic patients undergoing contrast-enhanced CT on a novel PCD-CT system between 08/2021 and 01/2022. The interval between complete blood count (CBC) and CT scan acquisition had to be no more than seven days. CT-values of the blood pool were measured on 70 keV VMI series (CT-values(BP)70keV) and on VNC series (CT-values(BP)VNC) at five anatomic positions (left atrium, left ventricle, main pulmonary artery, ascending and descending aorta) and averaged per patient. Pearson correlation analyses and ROC analyses were performed to identify relations between CT-values(BP)VNC, CBC parameters, and degrees of anemia as defined by the WHO (no anemia, mild, moderate, severe anemia). RESULTS: A total of 329 patients (age 68 ± 12 years; 200 men) were included. CT-values(BP)VNC showed a strong linear correlation to serum hemoglobin (r2 = 0.80, p <.001) and hematocrit (r2 = 0.76, p <.001) and were significantly different between anemia subgroups in both women and men (ΔHU: 3.5-11.4; all p <.01). ROC analyses yielded high diagnostic performance for the identification of patients without anemia, patients without and with mild anemia, and patients with severe anemia using gender-specific cutoffs for CT-value(BP)VNC (all AUC's > 0.90). CONCLUSIONS: The spectral information inherent in PCD-CT acquisitions allows the detection and quantification of anemia in contrast-enhanced CT acquisitions of oncologic patients with high diagnostic accuracy.


Asunto(s)
Interpretación de Imagen Radiográfica Asistida por Computador , Tomografía Computarizada por Rayos X , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Hemoglobinas , Estudios Prospectivos , Curva ROC , Prueba de Estudio Conceptual
10.
Cancers (Basel) ; 15(10)2023 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-37345128

RESUMEN

This study analyzes nationwide trends in HCC hospitalizations focusing on interventional liver-directed treatments and the influence of age and gender. Using data from the German Federal Statistical Office all hospitalizations for HCC between 2010 and 2020 were included. Uni- and multivariable logistic regression analyses were performed to identify variables independently associated with the use of liver-directed therapies. Due to the COVID-19 pandemic, data from 2020 were analyzed separately. A total of 134,713 hospitalizations (2010-2019) were included, increasing by 3.4% annually (12,707 to 13,143). The mean in-hospital stay (-15.0% [7.2 to 6.1 days]) and mortality (-23.2% [6.8 to 5.2%]) decreased while transarterial, surgical, and percutaneous ablative interventions increased by 38.6, 31.5, and 19.3%, respectively. In-hospital mortality was 7.7% in admissions with surgical treatment, while it was 0.6 and 0.5% for transarterial and percutaneous interventions. Mortality was higher in females (6.2 vs. 5.7%). Females (OR 0.89 [0.86,0.91], p < 0.001) and patients ≥80 years (OR 0.81 [0.79,0.84], p < 0.001) were less likely to receive liver-directed treatments. Liver-directed therapies were increasingly performed while in-hospital mortality and in-hospital stay decreased. Minimally invasive approaches showed lower mortality, shorter in-hospital stay, and lower costs compared to surgery. Proportionately, more women and older patients were hospitalized, receiving fewer liver-directed treatments while their mortality was higher.

11.
Diagn Interv Radiol ; 29(3): 492-499, 2023 05 31.
Artículo en Inglés | MEDLINE | ID: mdl-36993776

RESUMEN

PURPOSE: Re-entry devices contribute to the high success rate of subintimal recanalization of chronic total occlusions (CTO). However, to date, there are no studies comparing the available conventional re-entry devices concerning the impact of their technical success on economic aspects, as these devices differ greatly in their acquisition costs. This prospective observational study intends to contribute to this question. METHODS: Prior to the start of the prospective study, all previous applications of the Outback® in femoro-popliteal CTO since its introduction to our hospital were analyzed retrospectively (n = 31). From June 2018 until January 2020, all patients with femoro-popliteal CTO treated with clear subintimal recanalization were included (n = 109). In the case of failed spontaneous re-entry, either the OffRoad® (study arm I, n = 20) or the Enteer® catheter (study arm II, n = 20) was used. If assisted re-entry failed, the Outback® device was used as a bailout. Baseline demographic and clinical data, morphologic characteristics, and technical success were documented. Additional per-patient costs due to the use of re-entry devices were analyzed. RESULTS: A retrospective evaluation of all Outback® applications revealed a technical success rate of 97% (30/31). In the prospective study, 63% (68/109) were successfully treated without using re-entry devices. The overall procedural success was 95% (103/109). In study arm I, the OffRoad® achieved a success rate of 45% (9/20), with a subsequent successful application of the Outback® in 80% (8/10) of the failed cases. In study arm II, the Enteer® was successfully employed in 60% (12/20) of cases, and the Outback® was then used successfully in a further 62% (5/8) of cases. Too large a distance between the device and the target lumen was a knockout criterion for all tested devices, leading to a subgroup analysis with the exclusion of three cases, resulting in a success rate of 47% for the OffRoad® and 67% for the Enteer® device. Furthermore, in severe calcification, only the Outback® reliably enabled revascularization. Significant savings of almost €600 were only achieved in study arm II according to German prices. CONCLUSION: With proper patient selection, a gradual approach with the Enteer® as the primarily used device, with the Outback® used additionally in case of failure, leads to significant savings and can be recommended. In severe calcification, the Outback® should be used as the primary device.


Asunto(s)
Arteriopatías Oclusivas , Enfermedad Arterial Periférica , Humanos , Estudios Retrospectivos , Estudios Prospectivos , Resultado del Tratamiento , Arteria Femoral/cirugía , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/cirugía , Arteriopatías Oclusivas/terapia , Enfermedad Crónica
12.
Diagnostics (Basel) ; 13(6)2023 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-36980471

RESUMEN

PURPOSE: Coronary artery disease (CAD) and peripheral artery disease (PAD) are highly prevalent in society. This nationwide analysis aimed to evaluate the trends of in-hospital treatment of patients admitted due to PAD with and without concomitant CAD, to determine the prevalence and risk factors of concomitant CAD in patients with PAD. METHODS: Using data from the German Federal Statistical Office, we included all admissions for PAD (with and without concomitant CAD) in Germany between 2009 and 2018. Baseline patient characteristics, outcomes and comorbidities were analyzed. Elixhauser comorbidity groups and the linear van Walraven comorbidity score (vWs) were calculated to assess the comorbidity burden. RESULTS: Of all 1,793,517 patients hospitalized for PAD, a total of 21.8% (390,259) had concomitant CAD, increasing from 18.6% in 2009 to 24.4% in 2018. Patients with accompanying CAD showed higher in-hospital mortality (3.7 vs. 2.6%), more major amputations (9.0 vs. 7.7%) and more comorbidities (Elixhauser score: 4.2 vs. 3.2 and vWs: 9.1 vs. 6.1), resulting in higher costs (median: EUR 4541 vs. EUR 4268 per case). More advanced stages of PAD were associated with multi-vessel CAD (10% of all patients with PAD Fontaine IV showed 3-vessel CAD) and the prevalence of multi-vessel CAD increased predominantly in patients with advanced PAD. CONCLUSION: One in four patients hospitalized for PAD had concomitant CAD, showing an increase over time with an additional medical and economic burden for hospitals compared with patients without CAD.

13.
Invest Radiol ; 58(9): 691-696, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-36897803

RESUMEN

OBJECTIVE: The aim of this study was to compare the effectiveness of common strategies for artifact reduction of dental material in photon-counting detector computed tomography data sets. MATERIALS AND METHODS: Patients with dental material who underwent clinically indicated CT of the neck were enrolled. Image series were reconstructed using a standard and sharp kernel, with and without iterative metal artifact reduction (IMAR) (Qr40, Qr40 IMAR , Qr60, Qr60 IMAR ) at different virtual monoenergetic imaging (VMI) levels (40-190 keV). On representative slice positions with and without dental artifacts, mean and standard deviation of CT values were measured in all series at identical locations. The mean absolute error of CT values ( ) and the artifact index (AIX) were calculated and analyzed focusing on 3 main comparisons: ( a ) different VMI levels versus 70 keV, ( b ) standard versus sharp kernel, and ( c ) nonuse or use of IMAR reconstruction. The Wilcoxon test was used to assess differences for nonparametric data. RESULTS: The final cohort comprised 50 patients. Artifact measures decreased for VMI levels >70 keV, yet only significantly so for reconstructions using IMAR (maximum reduction, 25%). The higher image noise of the sharp versus standard kernel is reflected in higher AIX values and is more pronounced in IMAR series (maximum increase, 38%). The most profound artifact reduction was observed for IMAR reconstructions (maximum reduction : 84%; AIX: 90%). CONCLUSIONS: Metal artifacts caused by large amounts of dental material can be substantially reduced by IMAR, regardless of kernel choice or VMI settings. Increasing the keV level of VMI series, on the other hand, only slightly reduces dental artifacts; this effect, however, is additive to the benefit conferred by IMAR reconstructions.


Asunto(s)
Artefactos , Metales , Humanos , Tomografía Computarizada por Rayos X/métodos , Cuello , Materiales Dentales , Algoritmos
14.
Eur Radiol ; 33(4): 2450-2460, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36462042

RESUMEN

OBJECTIVES: To assess epicardial adipose tissue (EAT) volume and attenuation of different virtual non-contrast (VNC) reconstructions derived from coronary CTA (CCTA) datasets of a photon-counting detector (PCD) CT-system to replace true non-contrast (TNC) series. METHODS: Consecutive patients (n = 42) with clinically indicated CCTA and coronary TNC were included. Two VNC series were reconstructed, using a conventional (VNCConv) and a novel calcium-preserving (VNCPC) algorithm. EAT was segmented on TNC, VNCConv, VNCPC, and CCTA (CTA-30) series using thresholds of -190 to -30 HU and an additional segmentation on the CCTA series with an upper threshold of 0 HU (CTA0). EAT volumes and their histograms were assessed for each series. Linear regression was used to correlate EAT volumes and the Euclidian distance for histograms. The paired t-test and the Wilcoxon signed-rank test were used to assess differences for parametric and non-parametric data. RESULTS: EAT volumes from VNC and CCTA series showed significant differences compared to TNC (all p < .05), but excellent correlation (all R2 > 0.9). Measurements on the novel VNCPC series showed the best correlation (R2 = 0.99) and only minor absolute differences compared to TNC values. Mean volume differences were -12%, -3%, -13%, and +10% for VNCConv, VNCPC, CTA-30, and CTA0 compared to TNC. Distribution of CT values on VNCPC showed less difference to TNC than on VNCConv (mean attenuation difference +7% vs. +2%; Euclidean distance of histograms 0.029 vs. 0.016). CONCLUSIONS: VNCPC-reconstructions of PCD-CCTA datasets can be used to reliably assess EAT volume with a high accuracy and only minor differences in CT values compared to TNC. Substitution of TNC would significantly decrease patient's radiation dose. KEY POINTS: • Measurement of epicardial adipose tissue (EAT) volume and attenuation are feasible on virtual non-contrast (VNC) series with excellent correlation to true non-contrast series (all R2>0.9). • Differences in VNC algorithms have a significant impact on EAT volume and CT attenuation values. • A novel VNC algorithm (VNCPC) enables reliable assessment of EAT volume and attenuation with superior accuracy compared to measurements on conventional VNC- and CCTA-series.


Asunto(s)
Angiografía , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Reproducibilidad de los Resultados , Fotones , Tejido Adiposo/diagnóstico por imagen , Estudios Retrospectivos
15.
Vascular ; : 17085381221135704, 2022 Nov 17.
Artículo en Inglés | MEDLINE | ID: mdl-36384358

RESUMEN

OBJECTIVES: An aberrant right subclavian artery (ARSA) is one of the most common anatomic variants of the aortic arch. The combination of an ARSA and a transection is naturally rare. METHODS: This case report describes the treatment of a transection in the presence of an ARSA and the follow-up of two years. RESULTS: We successfully treated the contained rupture with a stentgraft. Both subclavian arteries had to be covered in the emergency setting. At the two-year follow-up, the patient did not suffer from any neurological impairment. CONCLUSIONS: In emergency settings, primary cover of both subclavian arteries with a stentgraft can be performed in individual cases after risk assessment. Severe complications such as development of upper limb ischaemia, ASAS or reduced perfusion of the posterior cerebral circulation should be considered in treatment planning.

17.
Dtsch Arztebl Int ; 119(37): 611-618, 2022 09 16.
Artículo en Inglés | MEDLINE | ID: mdl-35734915

RESUMEN

BACKGROUND: Studies from Denmark and the USA have shown differences in treatment outcomes for patients with peripheral arterial occlusive disease (PAOD) between hospitals of different size and certification status. For Germany, it is not known whether certification as a specialist center for vascular diseases or hospital size is associated with differences in the primary treatment outcome. METHODS: Using data from the German Federal Statistical Office, all hospitalizations due to PAOD of Fontaine stage IIb or higher were included in our study and the hospitals were classified according to their size and certification status. PAOD stage, age, sex, and comorbidities were documented for each hospitalization. Univariate and multivariate logistic regressions were performed to identify independent variables that predict various treatment endpoints. RESULTS: A total of 558 785 hospitalizations were included for analysis, of which 29% were in hospitals with certified vascular centers. In multivariate analysis, admissions to certified hospitals were associated with lower rates of major amputation (odds ratio [OR] 0.95, 95% confidence interval [0.92; 0.98], p = 0.003) and higher rates of minor amputation (OR 1.04 [1.01; 1.06], p = 0.004) with no difference observed in mortality (OR 0.99 [0.96; 1.03], p = 0.791). Admissions to larger hospitals were associated with more comorbidities, longer hospital stays, and higher rates of mortality and amputations. CONCLUSION: Treatments in certified hospitals are associated with fewer major and more minor amputations. This may reflect intensification of therapy targeting preservation of functional limbs.


Asunto(s)
Arteriopatías Oclusivas , Enfermedad Arterial Periférica , Humanos , Arteriopatías Oclusivas/epidemiología , Arteriopatías Oclusivas/terapia , Arteriopatías Oclusivas/complicaciones , Enfermedad Arterial Periférica/epidemiología , Enfermedad Arterial Periférica/terapia , Amputación Quirúrgica , Resultado del Tratamiento , Hospitales , Estudios Retrospectivos , Factores de Riesgo
18.
Diagnostics (Basel) ; 12(6)2022 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-35741276

RESUMEN

Artificial intelligence is gaining increasing relevance in the field of radiology. This study retrospectively evaluates how a commercially available deep learning algorithm can detect pneumonia in chest radiographs (CR) in emergency departments. The chest radiographs of 948 patients with dyspnea between 3 February and 8 May 2020, as well as 15 October and 15 December 2020, were used. A deep learning algorithm was used to identify opacifications associated with pneumonia, and the performance was evaluated by using ROC analysis, sensitivity, specificity, PPV and NPV. Two radiologists assessed all enrolled images for pulmonal infection patterns as the reference standard. If consolidations or opacifications were present, the radiologists classified the pulmonal findings regarding a possible COVID-19 infection because of the ongoing pandemic. The AUROC value of the deep learning algorithm reached 0.923 when detecting pneumonia in chest radiographs with a sensitivity of 95.4%, specificity of 66.0%, PPV of 80.2% and NPV of 90.8%. The detection of COVID-19 pneumonia in CR by radiologists was achieved with a sensitivity of 50.6% and a specificity of 73%. The deep learning algorithm proved to be an excellent tool for detecting pneumonia in chest radiographs. Thus, the assessment of suspicious chest radiographs can be purposefully supported, shortening the turnaround time for reporting relevant findings and aiding early triage.

19.
Diagnostics (Basel) ; 12(5)2022 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-35626387

RESUMEN

In dual-energy CT datasets, the conspicuity of liver metastases can be enhanced by virtual monoenergetic imaging (VMI) reconstructions at low keV levels. Our study investigated whether this effect can be reproduced in photon-counting detector CT (PCD-CT) datasets. We analyzed 100 patients with liver metastases who had undergone contrast-enhanced CT of the abdomen on a PCD-CT (n = 50) or energy-integrating detector CT (EID-CT, single-energy mode, n = 50). PCD-VMI-reconstructions were performed at various keV levels. Identical regions of interest were positioned in metastases, normal liver, and other defined locations assessing image noise, tumor-to-liver ratio (TLR), and contrast-to-noise ratio (CNR). Patients were compared inter-individually. Subgroup analyses were performed according to BMI. On the PCD-CT, noise and CNR peaked at the low end of the keV spectrum. In comparison with the EID-CT, PCD-VMI-reconstructions exhibited lower image noise (at 70 keV) but higher CNR (for ≤70 keV), despite similar CTDIs. Comparing high- and low-BMI patients, CTDI-upregulation was more modest for the PCD-CT but still resulted in similar noise levels and preserved CNR, unlike the EID-CT. In conclusion, PCD-CT VMIs in oncologic patients demonstrated reduced image noise-compared to a standard EID-CT-and improved conspicuity of hypovascularized liver metastases at low keV values. Patients with higher BMIs especially benefited from constant image noise and preservation of lesion conspicuity, despite a more moderate upregulation of CTDI.

20.
Eur J Trauma Emerg Surg ; 48(5): 4169-4179, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35359157

RESUMEN

PURPOSE: Intraoperative injury to the popliteal artery is a rare complication of orthopedic surgery, however, it can have serious consequences, including major amputation. Recommendations for a standard approach are lacking. The aim of this study was to develop an interdisciplinary therapeutic algorithm to assist in complication management. METHODS: From 01/11 to 12/20, 16 arterial injuries after knee surgery were analyzed in a retrospective single-center study. Four cases involved recurrent orthopedic surgery. Procedures performed included eleven total knee arthoplasties (TKA), two TKA replacements, one arthroscopy, and two high tibial osteotomies. Clinical presentation of patients was hemorrhage (n = 2), ischemia (n = 7), the combination of both (n = 4), or pseudoaneurysm formation (n = 3). RESULTS: Ten patients underwent endovascular treatment, some as combined procedures: (stent)-PTA (n = 6), aspiration thrombectomy (n = 5), thrombin injection (n = 1), and embolization (n = 1). Six patients were treated surgically: four with bypass/interposition and one with a patch plasty and one as a hybrid procedure, respectively. Only autologous great saphenous vein was used. All extremities could be preserved. Functional impairment remained in six cases. CONCLUSION: Both endovascular and surgical procedures can be used to treat arterial injuries after knee surgery. Efficient standardized diagnosis and the involvement of vascular expertise are essential to prevent functional impairment or limb loss, as suggested in the algorithms.


Asunto(s)
Arteria Poplítea , Lesiones del Sistema Vascular , Algoritmos , Amputación Quirúrgica , Humanos , Enfermedad Iatrogénica , Extremidad Inferior , Arteria Poplítea/cirugía , Estudios Retrospectivos , Trombina , Resultado del Tratamiento , Lesiones del Sistema Vascular/diagnóstico por imagen , Lesiones del Sistema Vascular/etiología , Lesiones del Sistema Vascular/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...