Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
Sci Rep ; 13(1): 17643, 2023 10 17.
Artículo en Inglés | MEDLINE | ID: mdl-37848443

RESUMEN

The purpose of this retrospective study was to evaluate the occurrence of infectious complications and inflammatory reactions after transabdominal lymphatic-interventions. 63 lymphatic-interventions were performed in 60 patients (male/female: 35/25; mean age 56 [9-85] years) [chylothorax n = 48, chylous ascites n = 7, combined chylothorax/chylous ascites n = 5]. Post-interventional clinical course and laboratory findings were analyzed in the whole cohort as well as subgroups without (group A; n = 35) and with peri-interventional antibiotics (group B; n = 25) (pneumonia n = 16, drainage-catheter inflammation n = 5, colitis n = 1, cystitis n = 1, transcolonic-access n = 2). No septic complications associated with the intervention occurred. Leucocytes increased significantly, peaking on post-interventional day-1 (8.6 ± 3.9 × 106 cells/mL vs. 9.8 ± 4.7 × 106 cells/mL; p = 0.009) and decreased thereafter (day-10: 7.3 ± 2.7 × 106 cells/mL, p = 0.005). CRP-values were pathological in 89.5% of patients already at baseline (40.1 ± 63.9 mg/L) and increased significant on day-3 (77.0 ± 78.8 mg/L, p < 0.001). Values decreased thereafter (day-15: 25.3 ± 34.4 mg/L, p = 0.04). In subgroup B, 13/25 patients had febrile episodes post-interventionally (pneumonia n = 11, cystitis n = 1, drainage-catheter inflammation n = 1). One patient developed biliary peritonitis despite continued antibiotics and underwent cholecystectomy. Baseline leucocytes and CRP-levels were higher in group B than A, but with comparable post-interventional profiles. Clinically relevant infectious complications associated with transabdominal lymphatic-interventions are rare irrespective of peri-interventional antibiotic use. Post-interventional elevation of leucocytes and CRP are observed with normalization over 10-15 days.


Asunto(s)
Quilotórax , Ascitis Quilosa , Cistitis , Neumonía , Humanos , Masculino , Femenino , Persona de Mediana Edad , Quilotórax/etiología , Ascitis Quilosa/etiología , Estudios Retrospectivos , Inflamación/complicaciones , Antibacterianos/uso terapéutico , Neumonía/complicaciones
2.
Laryngoscope Investig Otolaryngol ; 7(5): 1456-1464, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36258852

RESUMEN

Background: Idiopathic recurrent cervical swelling may be caused by lymphatic abnormalities. Methods: Ten patients (9 females, mean age 51.2 ± 7) with idiopathic recurrent cervical swelling underwent MR-lymphangiography (MRL). MR-lymphangiograms were evaluated regarding lymphatic anatomy and flow. Individualized treatment was recommended according to MRL-findings. Results: 8/10 patients presented with left-sided, 2/10 with right-sided swelling. Pathological lymph-flow was identified in all cases: thoracic duct dilatation in patients with left-sided and right lymphatic duct dilatation in right-sided swelling, accessory thoracic lymphatics in 7/10 and reflux in 8/10 cases. In two cases, a lymphatic thrombus was identified.After treatment, symptoms resolved completely in 6/10 cases and partially in 1/10 cases. The remaining three patients have intermittent swellings but have no treatment wish. Conclusion: Idiopathic recurrent cervical swelling can be caused by lymphatic anomalies. MRL displays impaired lymphatic drainage, lymphatic vessel dilatation, and chylolymphatic reflux as hallmarks of this condition and may aid in targeted treatment planning.

3.
Rofo ; 193(1): 68-76, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32516822

RESUMEN

PURPOSE: To investigate if T1 and T2 mapping is able to differentiate between diseased and healthy myocardium in patients with systemic sarcoidosis, and to compare the standard mapping measurement (measurement within the whole myocardium of the midventricular short axis slice, SAX) to a more standardized method measuring relaxation times within the midventricular septum (ConSept). MATERIALS AND METHODS: 24 patients with biopsy-proven extracardiac sarcoidosis and 17 healthy control subjects were prospectively enrolled in this study and underwent CMR imaging at 1.5 T including native T1 and T2 mapping. Patients were divided into patients with (LGE+) and without (LGE-) cardiac sarcoidosis. T1 and T2 relaxation times were compared between patients and controls. Furthermore, the SAX and the ConSept approach were compared regarding differentiation between healthy and diseased myocardium. RESULTS: T1 and T2 relaxation times were significantly longer in all patients compared with controls using both the SAX and the ConSept approach (p < 0.05). However, LGE+ and LGE- patients showed no significant differences in T1 and T2 relaxation times regardless of the measurement approach used (ConSept/SAX) (p > 0.05). Direct comparison of ConSept and SAX T1 mapping showed high conformity in the discrimination between healthy and diseased myocardium (Kappa = 0.844). CONCLUSION: T1 and T2 mapping may not only enable noninvasive recognition of cardiac involvement in patients with systemic sarcoidosis but may also serve as a marker for early cardiac involvement of the disease allowing for timely treatment. ConSept T1 mapping represents an equivalent method for tissue characterization in this population compared to the SAX approach. Further studies including follow-up examinations are necessary to confirm these preliminary results. KEY POINTS: · Mapping may enable noninvasive recognition of cardiac involvement in patients with systemic sarcoidosis. · Mapping may serve as a marker for early cardiac involvement in patients with systemic sarcoidosis. · The ConSept approach can be used as an alternative measuring method in sarcoidosis patients. CITATION FORMAT: · Dabir D, Luetkens J, Kuetting D et al. Myocardial Mapping in Systemic Sarcoidosis: A Comparison of Two Measurement Approaches. Fortschr Röntgenstr 2021; 193: 68 - 76.


Asunto(s)
Cardiomiopatías/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Sarcoidosis/diagnóstico por imagen , Adulto , Estudios de Casos y Controles , Medios de Contraste , Diagnóstico Diferencial , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Compuestos Organometálicos
4.
Radiother Oncol ; 146: 172-179, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32171945

RESUMEN

PURPOSE: Radiation dermatitis represents one of the most frequent side effects in breast cancer patients undergoing adjuvant whole-breast irradiation (WBI). Whether hypofractionated WBI induces comparable or less acute radiation-induced skin reactions than conventional WBI is still not fully clarified, as randomized evidence and objective assessments are limited. The aim of this study was to objectively determine frequency and severity of acute radiation-induced skin reactions during hypofractionated vs. conventionally fractionated adjuvant WBI. METHODS: In this randomized multicenter study, a total of 140 breast cancer patients underwent either hypofractionated or conventional WBI following breast-preserving surgery. Maximum radiation dermatitis severity was assessed at completion and during follow-up by physician-assessed CTCAE v4.03 and the patient-reported RISRAS scale. Additionally, photospectrometric skin readings were performed to objectify skin color differences between both treatment arms. RESULTS: Radiation dermatitis severity was significantly lower in patients receiving hypofractionation compared with conventional fractionation (mean 1.05 vs. 1.43, p = .024). Grade 0 radiation dermatitis occurred in 21.43% vs. 4.28%, grade ≥2 in 27.14% vs. 42.91% and grade ≥3 in 0% vs. 4.34% of patients following hypofractionated and conventional WBI, respectively. Objective photospectrometric measurements (n = 4200) showed both decreased erythema severity (p = .008) and hyperpigmentation (p = .002) in the hypofractionation arm. Patients allocated to hypofractionated WBI also reported less pain (p = .006), less hyperpigmentation (p = <0.001) and less limitations of day-to-day activities (p = <0.001). CONCLUSION: Physician and patient-assessed toxicity scorings as well as objective photospectrometric skin measurements revealed that hypofractionated WBI yielded lower rates and severity of acute radiation-induced skin toxicity.


Asunto(s)
Neoplasias de la Mama , Mastectomía Segmentaria , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/cirugía , Humanos , Hipofraccionamiento de la Dosis de Radiación , Radioterapia Adyuvante , Espectrofotometría
5.
J Vasc Interv Radiol ; 31(1): 74-79, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31771898

RESUMEN

PURPOSE: To determine how frequently and how severely intra-abdominal structures are affected by transabdominal thoracic duct embolization (TDE). MATERIALS AND METHODS: Thirty-five TDE procedures in 35 patients (22 male; mean age, 57 y; age range, 10-79 y) with therapy-refractory chylous effusions were evaluated in which radiopaque embolization material outlined the access route on postinterventional CT. CT data were analyzed by 2 TDE-experienced radiologists. Abdominal structures and organs transgressed by the access route were recorded, and findings were correlated with clinical postinterventional course with follow-up of at least 44 days. RESULTS: Intra-abdominal structures/organs transgressed most often by the access route were the liver (n = 28), crus of the diaphragm (n = 25), pancreas (n = 14), portal vein (n = 10), duodenum (n = 7), inferior vena cava (n = 5), colon (n = 3), left renal vein (n = 2), pleura (n = 2), pericardium (n = 2), and gastric sleeve (n = 2). Pancreatitis was observed in 1 of 14 patients after pancreatic transgression. One case of clinically occult pulmonary glue migration occurred on catheter pullback through the left renal vein. Biliary peritonitis was observed after gallbladder puncture, necessitating cholecystectomy in 1 of 2 transbiliary punctures. No other relevant procedure-related complications such as hemorrhages or infectious complications were observed. CONCLUSIONS: Despite transgression of intra-abdominal structures, puncture- and access-related complications of TDE are rare. Transpancreatic manipulations are reasonably well tolerated.


Asunto(s)
Quilotórax/terapia , Embolización Terapéutica , Conducto Torácico/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Adolescente , Adulto , Anciano , Enfermedades de los Conductos Biliares/diagnóstico por imagen , Enfermedades de los Conductos Biliares/etiología , Niño , Quilotórax/diagnóstico por imagen , Embolización Terapéutica/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pancreatitis/diagnóstico por imagen , Pancreatitis/etiología , Valor Predictivo de las Pruebas , Embolia Pulmonar/diagnóstico por imagen , Embolia Pulmonar/etiología , Punciones , Resultado del Tratamiento , Adulto Joven
6.
Strahlenther Onkol ; 195(7): 668-676, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30915490

RESUMEN

PURPOSE: A planning study was performed for helical tomotherapy treatment. We evaluated the maximum achievable protection of organs at risk (OARs) in patients with malignant pleural mesothelioma after pleurectomy with simultaneous optimal target coverage. MATERIALS AND METHODS: The datasets of 13 patients were included. The applied dose to the planning target volume (PTV) was 50.4 Gy with single doses of 1.8 Gy per fraction. Presuming optimal target coverage, we evaluated the applied dose to the OARs with special regard to the contralateral lung. RESULTS: For left-(lsRT)/right(rsRT)-sided radiotherapy, target coverage for the PTV showed a D98 (mean) of 49.37/49.71 Gy (98.0%/98.6%) and a D2 (mean) of 54.19/54.61 Gy (107.5%/108.3%). The beam-on time was kept below 15 min. The achieved mean dose (D50) to the contralateral lung was kept below 4 Gy for lsRT and rsRT. With regard to the other organs at risk the applied doses were as follows: mean dose (lsRT): ipsilateral kidney (Dmean) 13.03 (5.32-22.18) Gy, contralateral kidney (Dmean) <2.0 Gy, heart (Dmean) 22.23 (13.57-27.72) Gy, spinal cord D1

Asunto(s)
Neoplasias Pulmonares/radioterapia , Mesotelioma/radioterapia , Órganos en Riesgo/efectos de la radiación , Neoplasias Pleurales/radioterapia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada/métodos , Anciano , Terapia Combinada , Femenino , Humanos , Neoplasias Pulmonares/cirugía , Masculino , Mesotelioma/cirugía , Mesotelioma Maligno , Persona de Mediana Edad , Pleura/cirugía , Neoplasias Pleurales/cirugía , Radioterapia Adyuvante
7.
Zentralbl Chir ; 144(S 01): S24-S30, 2019 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-30795028

RESUMEN

Therapeutic options in management of chylothorax encompass conservative, surgical and also interventional measures. Despite the fact that interventions have been performed in substantial numbers of patients - particularly thoracic duct embolisations - general knowledge about this therapeutic option is still limited. Therefore, this article gives an overview of the state of the art for therapeutic options, also emphasising radiological/interventional procedures. At present, interventional treatment has lower morbidity and mortality, and is especially indicated after failed surgical therapy, or in inoperable patients.


Asunto(s)
Quilotórax , Embolización Terapéutica , Quilotórax/terapia , Humanos , Conducto Torácico
8.
Rofo ; 191(6): 553-559, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30562829

RESUMEN

PURPOSE: Percutaneous treatment of biliary leaks is frequently required, yet technically challenging and limited to smaller fistulas. This study sought to evaluate the off-the-shelf use of the ArtVentive EOS device for the occlusion of biliary or cystic stump leaks. MATERIALS AND METHODS: ePTFE-covered ArtVentive EOS devices were used to perform biliary leak embolization in 5 explanted porcine livers and in 3 explanted bovine livers. After establishing standard percutaneous transhepatic biliary drainage access, artificially created biliary leaks were occluded using 5 & 8 mm EOS devices. Using the 5 mm device, peripheral (n = 3), central (n = 1) and cystic duct leaks (n = 1) were occluded. Using the 8 mm device, peripheral (n = 1), central (n = 1), main (n = 1) and cystic duct leaks (n = 2) were occluded. Total leak occlusion was controlled by cholangiography. RESULTS: Selective deployment and occlusion of central biliary leaks (3/3) and cystic stump leaks (3/3) was successful in all cases. Peripheral leaks could not be selectively catheterized in 3 out of 4 cases, making device deployment several millimeters proximal to the leaks necessary. CONCLUSION: Selective occlusion of the cystic stump, central biliary, and larger peripheral biliary leaks using the EOS device is technically feasible ex-vivo in a single setting. KEY POINTS: · Due to the impermeable ePTFE membrane, one EOS suffices to completely occlude biliary leaks.. · The EOS enables selective occlusion of central and larger peripheral biliary leaks.. · Smaller biliary leaks cannot be treated selectively with the EOS.. CITATION FORMAT: · Kuetting D, Schild HH, Pieper CC. Ex Vivo Evaluation of the ArtVentive EOS Occlusion Device for the Management of Biliary Leaks. Fortschr Röntgenstr 2019; 191: 553 - 559.


Asunto(s)
Angioplastia/instrumentación , Fístula Biliar/terapia , Conducto Cístico , Diseño de Equipo , Animales , Bovinos , Técnicas In Vitro , Porcinos
9.
Acta Radiol ; 60(2): 168-176, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29792040

RESUMEN

BACKGROUND: There is increased interest in pulmonary magnetic resonance imaging (MRI) as a radiation-free alternative to computed tomography (CT) for lung cancer screening. PURPOSE: To analyze MRI characteristics of pulmonary nodules with different non-enhanced sequences. MATERIAL AND METHODS: Eighty-two participants of a lung cancer screening were included. MRI datasets of 32 individuals with 46 different nodules ≥ 6 mm were prospectively evaluated together with 50 controls by two readers. Acquired sequences were T2- short tau inversion recovery (STIR), T2, balanced steady-state free precession (bSSFP), 3D-T1, and diffusion-weighted imaging (DWI). Each sequence was randomly and separately viewed blinded to low-dose CT (LDCT). Size, shape, and contrast of nodules were evaluated on each sequence and then correlated with LDCT and histopathology. RESULTS: All eight carcinomas were detected by T2-STIR, T2, and bSSFP, and 7/8 by 3D-T1. Contrast was significantly higher for malignant nodules on all sequences. The highest contrast ratio between malignant and benign nodules was provided by T2-STIR. Of eight carcinomas, seven showed restricted diffusion. Size measurement correlated significantly between MRI and LDCT. Sensitivity/specificity for nodules ≥ 6 mm was 85-89%/92-94% for T2-STIR, 80-87%/93-96% for T2, 65-70%/96-98% for bSSFP, and 63-67%/96-100% for 3D-T1. Seven of eight subsolid nodules were visible on T2-sequences with significantly lower lesion contrast compared to solid nodules. Two of eight subsolid nodules were detected by bSFFP, none by 3D-T1. All three calcified nodules were detected by 3D-T1, one by bSSFP, and none by T2-sequences. CONCLUSION: Malignant as well as calcified and subsolid nodules seem to have distinctive characteristics on different MRI sequences. T2-imaging was most suitable for the detection of nodules ≥ 6 mm.


Asunto(s)
Adenocarcinoma/diagnóstico por imagen , Neoplasias Pulmonares/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Carcinoma Pulmonar de Células Pequeñas/diagnóstico por imagen , Adenocarcinoma/patología , Anciano , Biopsia , Estudios de Casos y Controles , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Neoplasias Pulmonares/patología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad , Carcinoma Pulmonar de Células Pequeñas/patología , Tomografía Computarizada por Rayos X
10.
Clin Neuroradiol ; 29(4): 623-630, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30014154

RESUMEN

PURPOSE: Limbic encephalitis (LE) is an immune-related disease with limbic symptoms, variable and asymmetric magnetic resonance imaging (MRI) aspects and antibody profiles. This study investigated the diagnostic value of quantitative relaxation times T2 (qT2) and MRI signal intensities (SI) in LE. METHODS: The prospective 3T-MRI study included 39 epilepsy patients with initially suspected LE and 20 healthy controls. Values and asymmetry indices of qT2, T2-weighted (T2-w) and proton density (PD)-w SI of manually delineated and automatically segmented amygdala and hippocampus were measured. Additionally, two raters made a blinded visual analysis on FLAIR (fluid attenuation inversion recovery) and T2-w images. RESULTS: According to diagnostic guidelines, 22 patients had probable LE and 17 patients had possible LE. The qT2 was higher (p < 0.01) in patients than in controls (mean ± SD, amygdala 98 ± 7 ms vs. 90 ± 5 ms, hippocampus 101 ± 7 ms vs. 92 ± 3 ms), but was not different between probable and possible LE or between sides (left and right). The PD-w SI and T2-w SI were lower in patients than in controls but were not different between patient subgroups or between sides. Diagnostic performance of visual analysis was relatively poor. CONCLUSIONS: Epilepsy patients with suspected LE had elevated qT2 in amygdala and hippocampus, whereas the expected T2-w SI increase was not found; however, the diagnostic value of qT2 remains questionable since it did not discriminate probable from possible LE.


Asunto(s)
Epilepsia/diagnóstico por imagen , Encefalitis Límbica/diagnóstico por imagen , Adolescente , Adulto , Anciano , Amígdala del Cerebelo/diagnóstico por imagen , Amígdala del Cerebelo/patología , Estudios de Casos y Controles , Niño , Epilepsia/etiología , Epilepsia/patología , Femenino , Hipocampo/diagnóstico por imagen , Hipocampo/patología , Humanos , Encefalitis Límbica/complicaciones , Encefalitis Límbica/patología , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Adulto Joven
11.
Eur Radiol ; 29(2): 898-905, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29992387

RESUMEN

PURPOSE: To evaluate MRI for lung cancer screening comparing LDCT- and MRI-derived Lung-RADS categories in the first two screening rounds. MATERIALS AND METHODS: 224 participants in a lung cancer screening study were examined with MRI and low-dose CT (LDCT). Acquired MRI sequences were T2, balanced, T1 and DWI. MRI was prospectively analysed regarding nodules. Minimum nodule size was 4 mm. Nodules were assigned a Lung-RADS score based on appearance and size at baseline and after 3, 6 and 12 months. MRI findings were correlated with LDCT. RESULTS: The early recall rate dropped from 13.8% at baseline to 1.9% in the second screening round with biopsy rates of 3.6% in the first round and 0.5% in the second round. Histology revealed lung cancer in 8/9 participants undergoing biopsy/surgery. All eight cancers were accurately depicted by MRI. The following categories were assigned on MRI (results of LDCT in parentheses): 4B/4X in 10 (10) cases, 4A in 16 (15) cases, 3 in 13 (12) cases, 2 in 77 (92) cases and 1 in 140 (126) cases. Lung-RADS scoring correlated significantly between MRI and CT. The score was overestimated by MRI in one case for category 4A, in two cases for category 3 and in five cases for category 2. MRI-based Lung-RADS score was underestimated for category 1 in 20 cases. CONCLUSION: Lung-RADS might be applied for lung cancer screening with MRI, since findings correlated with LDCT. Relevant findings with a Lung-RADS score of 3 and higher were never missed or underestimated by MRI KEY POINTS: • MRI performed comparably to low-dose CT in a lung cancer-screening programme. • Lung-RADS might be applied for lung cancer screening with MRI. • Lung-RADS findings score of 3 and higher were never missed by MRI.


Asunto(s)
Detección Precoz del Cáncer/métodos , Neoplasias Pulmonares/diagnóstico , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Tamizaje Masivo/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Biopsia , Femenino , Humanos , Masculino , Persona de Mediana Edad
12.
Polymers (Basel) ; 11(12)2019 Dec 16.
Artículo en Inglés | MEDLINE | ID: mdl-31888185

RESUMEN

Radiation-induced skin injury represents the most frequent side effect in breast cancer patients undergoing whole-breast irradiation (WBI). Numerous clinical studies on systemic and topical treatments for radiation dermatitis have failed to provide sustainable treatment strategies. While protective skin products such as dressings are undoubtedly the standard of care in wound care management, their utilization as preventive treatment in radiotherapy has been somewhat neglected in recent years. In this prospective, intra-patient randomized observational study, Hydrofilm polyurethane films were prophylactically applied to either the medial or lateral breast-half of 74 patients with breast cancer undergoing hypofractionated whole-breast irradiation following breast-preserving surgery. Maximum radiation dermatitis severity was assessed using Common Terminology Criteria for Adverse Events (CTCAE) v4.03 toxicity scores, photospectrometric erythema and pigmentation measurements and patient-assessed modified Radiation-Induced Skin Reaction Assessment Scale (RISRAS) scale. Phantom studies revealed a clinically negligible dose build-up of less than 0.1% with Hydrofilm. Compared to the control compartments physician-assessed radiation dermatitis severity was reduced in the hydrofilm compartments (mean 0.54 vs. 1.34; p = < 0.001). Objective photospectrometric skin measurements showed decreased erythema (p = 0.0001) and hyperpigmentation (p = 0.002) underneath Hydrofilm. Hydrofilm also completely prevented moist desquamation, and significantly reduced patients' treatment-related symptoms of itching, burning, pain, and limitations of day-to-day-activities. Significant beneficial effects were observed in terms of radiation dermatitis severity, erythema, hyperpigmentation as well as subjective treatment-related symptom experiences, while adverse reactions were rare and minor. Therefore, a prophylactic application of Hydrofilm polyurethane films can be suggested in hypofractionated WBI.

13.
Eur J Radiol ; 108: 59-65, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30396672

RESUMEN

OBJECTIVES: The aim of this prospective study was to evaluate the diagnostic performance of T2*-weighted magnetic resonance imaging (MRI) to differentiate between acute benign and neoplastic vertebral compression fractures (VCFs). MATERIALS AND METHODS: Thirty-seven consecutive patients with a total of 52 VCFs were prospectively enrolled in this IRB approved study. All VCFs were categorized as either benign or malignant according to direct bone biopsy and histopathologic confirmation. In addition to routine clinical spine MRI including at least sagittal T1-weighted, T2-weighted and T2 spectral attenuated inversion recovery (SPAIR)-weighted sequences, all patients underwent an additional sagittal six-echo modified Dixon gradient-echo sequence of the spine at 3.0-T. Intravertebral T2* and T2*ratio (fracture T2*/normal vertebrae T2*) for acute benign and malignant VCFs were calculated using region-of-interest analysis and compared between both groups. Additional receiver operating characteristic analyses were performed. Five healthy subjects were scanned three times to determine the short-term reproducibility of vertebral T2* measurements. RESULTS: There were 27 acute benign and 25 malignant VCFs. Both T2* and T2*ratio of malignant VCFs were significantly higher compared to acute benign VCFs (T2*, 30 ± 11 vs. 19 ± 11 ms [p = 0.001]; T2*ratio, 2.9 ± 1.6 vs. 1.2 ± 0.7 [p < 0.001]). The areas under the curve were 0.77 for T2* and 0.88 for T2*ratio, yielding an accuracy of 73% and 89% for distinguishing acute benign from malignant VCFs. The root mean square absolute precision error was 0.44 ms as a measure for the T2* short-term reproducibility. CONCLUSION: Quantitative assessment of vertebral bone marrow T2* relaxation times provides good diagnostic accuracy for the differentiation of acute benign and malignant VCFs.


Asunto(s)
Fracturas por Compresión/fisiopatología , Fracturas de la Columna Vertebral/fisiopatología , Adulto , Anciano , Anciano de 80 o más Años , Médula Ósea/patología , Médula Ósea/fisiología , Diagnóstico Diferencial , Femenino , Fracturas por Compresión/patología , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Curva ROC , Reproducibilidad de los Resultados , Enfermedades de la Columna Vertebral/patología , Enfermedades de la Columna Vertebral/fisiopatología , Fracturas de la Columna Vertebral/patología , Columna Vertebral/patología
14.
Eur Radiol ; 28(12): 5001-5009, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29858641

RESUMEN

OBJECTIVES: To evaluate the diagnostic performance of proton density fat fraction (PDFF) magnetic resonance imaging (MRI) to differentiate between acute benign and neoplastic vertebral compression fractures (VCFs). METHODS: Fifty-seven consecutive patients with 46 acute benign and 41 malignant VCFs were prospectively enrolled in this institutional review board approved study and underwent routine clinical MRI with an additional six-echo modified Dixon sequence of the spine at a clinical 3.0-T scanner. All fractures were categorised as benign or malignant according to either direct bone biopsy or 6-month follow-up MRI. Intravertebral PDFF and PDFFratio (fracture PDFF/normal vertebrae PDFF) for benign and malignant VCFs were calculated using region-of-interest analysis and compared between both groups. Additional receiver operating characteristic and binary logistic regression analyses were performed. RESULTS: Both PDFF and PDFFratio of malignant VCFs were significantly lower compared to acute benign VCFs [PDFF, 3.48 ± 3.30% vs 23.99 ± 11.86% (p < 0.001); PDFFratio, 0.09 ± 0.09 vs 0.49 ± 0.24 (p < 0.001)]. The areas under the curve were 0.98 for PDFF and 0.97 for PDFFratio, yielding an accuracy of 96% and 95% for differentiating between acute benign and malignant VCFs. PDFF remained as the only imaging-based variable to independently differentiate between acute benign and malignant VCFs on multivariate analysis (odds ratio, 0.454; p = 0.005). CONCLUSIONS: Quantitative assessment of PDFF derived from modified Dixon water-fat MRI has high diagnostic accuracy for the differentiation of acute benign and malignant vertebral compression fractures. KEY POINTS: • Chemical-shift-encoding based water-fat MRI can reliably assess vertebral bone marrow PDFF • PDFF is significantly higher in acute benign than in malignant VCFs • PDFF provides high accuracy for differentiating acute benign from malignant VCFs.


Asunto(s)
Fracturas por Compresión/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Fracturas de la Columna Vertebral/diagnóstico por imagen , Neoplasias de la Columna Vertebral/diagnóstico por imagen , Tejido Adiposo/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Enfermedades Óseas Metabólicas/patología , Médula Ósea/diagnóstico por imagen , Médula Ósea/patología , Diagnóstico Diferencial , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Estudios Prospectivos , Protones , Curva ROC , Adulto Joven
15.
Rofo ; 190(10): 938-945, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29665587

RESUMEN

PURPOSE: To describe a novel technique for transpedal magnetic resonance lymphangiography (tMRL) with interstitial injection of a standard gadolinium-based contrast agent, and to assess its ability to visualize the central lymphatic system (CLS) in patients with chylous effusions. MATERIALS AND METHODS: Experiences with tMRL were retrospectively reviewed in seven patients with chylous effusions. High-resolution three-dimensional multi-echo (mDIXON) images of the entire torso were obtained before and after interstitial injection of an extracellular gadolinium-based contrast agent. MR examinations were assessed qualitatively by two radiologists with respect to visualization of central lymphatics, delineation of their anatomy and presence of a lymphatic pathology (chylolymphatic leakage or reflux). RESULTS: Examination was technically successful in 6/7 patients. tMRL confirmed the location of chylolymphatic leakage in 3/7, demonstrated a lymphatic malformation in 1/7, chylolymphatic reflux in 1/7, and confirmed normal chylolymphatic flow in the central lymphatics in 1/7 patients. In one patient neither CLS enhancement nor leakage were detectable. tMRL findings were considered helpful in all technically successful cases, and considerably influenced further treatment in four patients. All examinations were well tolerated without complications. No general anesthesia or conscious sedation was necessary. CONCLUSION: Transpedal MR-lymphangiography with interstitial injection of a standard extracellular gadolinium-based contrast agent is feasible in clinical routine without general anesthesia and allows for assessment of pathologic conditions of central lymphatics. KEY POINTS: · Transpedal MR-lymphangiography of central lymphatics is technically feasible.. · A standard extracellular gadolinium-based contrast agent can be used for tMRL.. · tMRL allows for evaluation of anatomy and pathologies of central lymphatics.. · tMRL is a useful tool for treatment planning in chylous effusions.. CITATION FORMAT: · Pieper CC, Schild HH. Interstitial Transpedal MR-Lymphangiography of Central Lymphatics Using a Standard MR Contrast Agent: Feasibility and Initial Results in Patients with Chylous Effusions. Fortschr Röntgenstr 2018; 190: 938 - 945.


Asunto(s)
Quilotórax/diagnóstico por imagen , Ascitis Quilosa/diagnóstico por imagen , Imagen Eco-Planar/métodos , Imagenología Tridimensional/métodos , Sistema Linfático/diagnóstico por imagen , Linfografía/métodos , Adulto , Anciano , Femenino , Humanos , Inyecciones Intradérmicas , Sistema Linfático/anomalías , Masculino , Persona de Mediana Edad , Compuestos Organometálicos/administración & dosificación , Estudios Retrospectivos , Sensibilidad y Especificidad
16.
Acta Oncol ; 57(7): 908-915, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29463159

RESUMEN

PURPOSE: Radiation-induced skin injury represents one of the most common side effects in breast cancer patients receiving adjuvant whole-breast radiotherapy. Numerous systemic and topical treatments have been studied in the prevention and management of radiation-induced skin injury without providing sustainable treatment strategies. While superficial barrier-forming skin products such as dressings are the standard of care in wound care management, their utilization as preventive treatment approach in radiotherapy has barely attracted attention. METHODS: In this prospective, intra-patient randomized study, Hydrofilm polyurethane film dressings were applied prophylactically to either the medial or lateral breast half of 62 patients with breast cancer undergoing adjuvant radiation therapy following breast conserving surgery. The breast half contralateral to the film dressing was concurrently treated with 5% urea lotion as control skin care. Maximum severity of radiation dermatitis was assessed using RTOG/EORTC toxicity scores, photospectrometric erythema measurements and patient-assessed modified RISRAS scale. RESULTS: In the Hydrofilm compartments, mean maximum RTOG/EORTC radiation dermatitis severity grades were significantly reduced from 1.33 to 0.35 and photospectrometric measurements showed significantly reduced erythema severity, as compared to the control compartments, with an overall response rate of 89.3%. Hydrofilm completely prevented moist desquamation and significantly reduced patients' subjective experience of itching and pain. CONCLUSION: The obtained results along with a favorable cost-benefit ratio and an easy and quick application suggest a prophylactic application of Hydrofilm in adjuvant radiotherapy of breast cancer patients to reduce or even prevent radiation dermatitis.


Asunto(s)
Vendas Hidrocoloidales , Vendajes , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/cirugía , Poliuretanos/química , Profilaxis Pre-Exposición/métodos , Radiodermatitis/prevención & control , Administración Tópica , Adulto , Anciano , Anciano de 80 o más Años , Terapia Combinada , Femenino , Humanos , Mastectomía Segmentaria , Persona de Mediana Edad , Poliuretanos/administración & dosificación , Radioterapia Adyuvante/efectos adversos
17.
Eur Radiol ; 28(6): 2397-2405, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29313118

RESUMEN

OBJECTIVES: To investigate whether proton density fat fraction (PDFF) measurements using a six-echo modified Dixon sequence can help to differentiate between benign and malignant vertebral bone marrow lesions. METHODS: Sixty-six patients were prospectively enrolled in our study. In addition to conventional MRI at 3.0-Tesla including at least sagittal T2-weighted/spectral attenuated inversion recovery and T1-weighted sequences, all patients underwent a sagittal six-echo modified Dixon sequence of the spine. The mean PDFF was calculated using regions of interest and compared between vertebral lesions. A cut-off value of 6.40% in PDFF was determined by receiver operating characteristic curves and used to differentiate between malignant (< 6.40%) and benign (≥ 6.40%) vertebral lesions. RESULTS: There were 77 benign and 44 malignant lesions. The PDFF of malignant lesions was statistically significant lower in comparison with benign lesions (p < 0.001) and normal vertebral bone marrow (p < 0.001). The areas under the curves (AUC) were 0.97 for differentiating benign from malignant lesions (p < 0.001) and 0.95 for differentiating acute vertebral fractures from malignant lesions (p < 0.001). This yielded a diagnostic accuracy of 96% in the differentiation of both benign lesions and acute vertebral fractures from malignancy. CONCLUSION: PDFF derived from six-echo modified Dixon allows for differentiation between benign and malignant vertebral lesions with a high diagnostic accuracy. KEY POINTS: • Establishing a diagnosis of indeterminate vertebral lesions is a common clinical problem • Benign bone marrow processes may mimic the signal alterations observed in malignancy • PDFF differentiates between benign and malignant lesions with a high diagnostic accuracy • PDFF of non-neoplastic vertebral lesions is significantly higher than that of malignancy • PDFF from six-echo modified Dixon may help avoid potentially harmful bone biopsy.


Asunto(s)
Vértebras Cervicales/diagnóstico por imagen , Vértebras Lumbares/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Sacro/diagnóstico por imagen , Enfermedades de la Columna Vertebral/diagnóstico , Neoplasias de la Columna Vertebral/diagnóstico por imagen , Vértebras Torácicas/diagnóstico por imagen , Tejido Adiposo/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Protones , Curva ROC , Adulto Joven
18.
Strahlenther Onkol ; 194(5): 386-391, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29372290

RESUMEN

OBJECTIVE: To evaluate the interfractional variations of patient positioning during intensity-modulated radiotherapy (IMRT) with helical tomotherapy in head and neck cancer and to calculate the required safety margins (sm) for bony landmarks resulting from the necessary table adjustments. MATERIALS AND METHODS: In all, 15 patients with head and neck cancer were irradiated using the Hi-Art II tomotherapy system between April and September 2016. Before therapy sessions, patient position was frequently checked by megavolt computed tomography (MV-CT). Necessary table adjustments (ta) in the right-left (rl), superior-inferior (si) and anterior-posterior (ap) directions were recorded for four anatomical points: second, fourth and sixth cervical vertebral body (CVB), anterior nasal spine (ANS). Based upon these data sm were calculated for non-image-guided radiotherapy, image-guided radiotherapy (IGRT) and image guidance limited to a shortened area (CVB 2). RESULTS: Based upon planning CT the actual treatment required ta from -0.05 ± 1.31 mm for CVB 2 (ap) up to 2.63 ± 2.39 mm for ANS (rl). Considering the performed ta resulting from image control (MV-CT) we detected remaining ta from -0.10 ± 1.09 mm for CVB 4 (rl) up to 1.97 ± 1.64 mm for ANS (si). After theoretical adjustment of patients position to CVB 2 the resulting ta ranged from -0.11 ± 2.44 mm for CVB6 (ap) to 2.37 ± 2.17 mm for ANS (si). These data imply safety margins: uncorrected patient position: 3.63-9.95 mm, corrected positioning based upon the whole target volume (IGRT): 1.85-6.63 mm, corrected positioning based upon CVB 2 (IGRT): 3.13-6.66 mm. CONCLUSIONS: The calculated safety margins differ between anatomic regions. Repetitive and frequent image control of patient positioning is necessary that, however, possibly may be focussed on a limited region.


Asunto(s)
Adenocarcinoma/radioterapia , Carcinoma de Células Escamosas/radioterapia , Neoplasias de Oído, Nariz y Garganta/radioterapia , Posicionamiento del Paciente/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Adenocarcinoma/patología , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma de Células Escamosas/patología , Fraccionamiento de la Dosis de Radiación , Femenino , Humanos , Metástasis Linfática/patología , Metástasis Linfática/radioterapia , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Neoplasias de Oído, Nariz y Garganta/patología , Evaluación de Procesos y Resultados en Atención de Salud , Estudios Retrospectivos
20.
Eur Radiol ; 28(1): 24-30, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28687915

RESUMEN

PURPOSE: To evaluate revised PROPELLER (RevPROP) for T2-weighted imaging (T2WI) of the prostate as a substitute for turbo spin echo (TSE). MATERIALS AND METHODS: Three-Tesla MR images of 50 patients with 55 cancer-suspicious lesions were prospectively evaluated. Findings were correlated with histopathology after MRI-guided biopsy. T2 RevPROP, T2 TSE, diffusion-weighted imaging, dynamic contrast enhancement, and MR-spectroscopy were acquired. RevPROP was compared to TSE concerning PI-RADS scores, lesion size, lesion signal-intensity, lesion contrast, artefacts, and image quality. RESULTS: There were 41 carcinomas in 55 cancer-suspicious lesions. RevPROP detected 41 of 41 carcinomas (100%) and 54 of 55 lesions (98.2%). TSE detected 39 of 41 carcinomas (95.1%) and 51 of 55 lesions (92.7%). RevPROP showed fewer artefacts and higher image quality (each p < 0.001). No differences were observed between single and overall PI-RADS scores based on RevPROP or TSE (p = 0.106 and p = 0.107). Lesion size was not different (p = 0.105). T2-signal intensity of lesions was higher and T2-contrast of lesions was lower on RevPROP (each p < 0.001). CONCLUSION: For prostate cancer detection RevPROP is superior to TSE with respect to motion robustness, image quality and detection rates of lesions. Therefore, RevPROP might be used as a substitute for T2WI. KEY POINTS: • Revised PROPELLER can be used as a substitute for T2-weighted prostate imaging. • Revised PROPELLER detected more carcinomas and more suspicious lesions than TSE. • Revised PROPELLER showed fewer artefacts and better image quality compared to TSE. • There were no significant differences in PI-RADS scores between revised PROPELLER and TSE. • The lower T2-contrast of revised PROPELLER did not impair its diagnostic quality.


Asunto(s)
Artefactos , Imagen por Resonancia Magnética/métodos , Estadificación de Neoplasias/métodos , Próstata/diagnóstico por imagen , Neoplasias de la Próstata/diagnóstico , Anciano , Diagnóstico Diferencial , Humanos , Biopsia Guiada por Imagen , Masculino , Neoplasias de la Próstata/clasificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA