1.
Med Phys ; 48(7): 3425-3437, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33959977

RESUMEN

BACKGROUND: The large fractional doses, steep dose gradients, and small targets found in intracranial radiosurgery require extremely low beam delivery uncertainty. In the case of Gamma Knife radiosurgery (GKRS), this includes minimizing patient positioning system (PPS) positioning uncertainty. Existing QA techniques are recipe based, and feature point in time pass/fail tolerances. However, modern treatment machines, including the Gamma Knife Perfexion/Icon systems, record extensive internal data in treatment logs. These data can be analyzed through statistical process control (SPC) methods which are designed to detect changes in process behavior. The purpose of this study was to characterize the long-term (8+ year) performance of a Perfexion/Icon unit and use SPC methods to determine if performance changes could be detected at levels lower than existing QA and internal manufacturer performance tolerances. METHODS: In-house software was developed to parse Perfexion/Icon log-files and store relevant information on shot delivery in a relational database. A last-in, first-out (LIFO) queuing algorithm was created to heuristically match messages associated with a given delivered shot. Filtering criteria were developed to filter QA and uncompleted shots. The resulting matched shots were extracted. Achieved versus planned PPS position was determined for each PPS motor as well as for the vector magnitude difference in PPS position. Exponentially weighted moving average (EWMA) control charts were plotted to determine when process behavior changed over time. RESULTS: 53833 shots were delivered over an 8+ year span in the study. The mean vector magnitude PPS difference was 32.7 µm, with 97.5% of all shots within 70.1 µm. Several changes in PPS positioning behavior were observed over time, corresponding with control system faults on several occasions requiring PPS recalibration. EWMA control charts clearly demonstrate that these faults could be identified and possibly predicted as many as 3 years before there were faults beyond control system tolerance. CONCLUSION: The PPS of Gamma Knife Perfexion/Icon systems has extremely low positioning uncertainties. EWMA control chart method can be utilized to track PPS performance over time and can potentially detect changes in performance that may indicate a component requiring maintenance. This would allow planned service visits to mitigate problems and prevent unplanned downtime.


Asunto(s)
Radiocirugia , Humanos , Posicionamiento del Paciente , Programas Informáticos
2.
J Radiosurg SBRT ; 5(4): 315-322, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30538892

RESUMEN

BACKGROUND: Cone beam CT (CBCT) imaging has been integrated into the most recent version of the Leksell Gamma Knife for the primary purpose to facilitate fractionated therapy. CASE DESCRIPTION: This case study presents three patients where the CBCT system of the Gamma Knife Icon discovered potentially clinically significant frame shifts. In each case, patients were imaged with volumetric MR prior to stereotactic frame placement. Immediately following frame placement, diagnostic stereotactic CT imaging was acquired with a stereotactic indicator box attached to the frame. Following treatment planning and immediately before radiosurgery, a CBCT was acquired using the on-board imaging functionality of the Gamma Knife Icon, which provides a registration of the patient's anatomy to stereotactic space independent of that provided by the stereotactic frame/fiducials. Co-registration of the CT and CBCT provides an estimate of the difference between these two estimates of stereotactic coordinates. The vector magnitudes of the differences measured at the center of stereotactic space were 0.93mm, 2.64mm and 2.18 mm for Case 1, Case 2 and Case 3 respectively. CONCLUSIONS: Use of the CBCT functionality of the Gamma Knife Icon to verify the consistency of frame placement can prevent clinically significant targeting errors due to frame slippage or frame adapter mounting errors, and allows any required adjustments to be made without interrupting the overall treatment workflow.

3.
J Neurosurg ; 125(Suppl 1): 114-122, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27903195

RESUMEN

OBJECTIVE Patients with arteriovenous malformations (AVMs) treated with Gamma Knife radiosurgery (GKRS) subsequent to embolization suffer from elevated local failure rates and differences in adverse radiation effects. Onyx is a common embolic material for AVMs. Onyx is formulated with tantalum, a high atomic number (Z = 73) element that has been investigated as a source of dosimetric uncertainty contributing to the less favorable clinical results. However, prior studies have not modeled the complicated anatomical and beam geometries characteristic of GKRS. This study investigated the magnitude of dose perturbation that can occur due to Onyx embolization using clinically realistic anatomical and Gamma Knife beam models. METHODS Leksell GammaPlan (LGP) was used to segment the AVM nidus and areas of Onyx from postcontrast stereotactic MRI for 7 patients treated with GKRS postembolization. The resulting contours, skull surface, and clinically selected dose distributions were exported from LGP in DICOM-RT (Digital Imaging and Communications in Medicine-radiotherapy) format. Isocenter locations and dwell times were recorded from the LGP database. Contours were converted into 3D mesh representations using commercial and in-house mesh-editing software. The resulting data were imported into a Monte Carlo (MC) dose calculation engine (Pegasos, Elekta Instruments AB) with a beam geometry for the Gamma Knife Perfexion. The MC-predicted dose distributions were calculated with Onyx assigned manufacturer-reported physical constants (MC-Onyx), and then compared with corresponding distributions in which Onyx was reassigned constants for water (MC-water). Differences in dose metrics were determined, including minimum, maximum, and mean dose to the AVM nidus; selectivity index; and target coverage. Combined differences in dose magnitude and distance to agreement were calculated as 3D Gamma analysis passing rates using tolerance criteria of 0.5%/0.5 mm, 1.0%/1.0 mm, and 3.0%/3.0 mm. RESULTS Overall, the mean percentage differences in dose metrics for MC-Onyx relative to MC-water were as follows; all data are reported as mean (SD): minimum dose to AVM = -0.7% (1.4%), mean dose to AVM = 0.1% (0.2%), maximum dose to AVM = 2.9% (5.0%), selectivity = 0.1% (0.2%), and coverage = -0.0% (0.2%). The mean percentage of voxels passing at each Gamma tolerance were as follows: 99.7% (0.1%) for 3.0%/3.0 mm, 98.2% (0.7%) for 1.0%/1.0 mm, and 52.1% (4.4%) for 0.5%/0.5 mm. CONCLUSIONS Onyx embolization appears to have a detectable effect on the delivered dose distribution. However, the small changes in dose metrics and high Gamma passing rates at 1.0%/1.0 mm tolerance suggest that these changes are unlikely to be clinically significant. Additional sources of delivery and biological uncertainty should be investigated to determine the root cause of the observed less favorable postembolization GKRS outcomes.


Asunto(s)
Embolización Terapéutica/métodos , Malformaciones Arteriovenosas Intracraneales/terapia , Radiocirugia , Tantalio , Terapia Combinada , Humanos , Dosificación Radioterapéutica
4.
Radiat Oncol ; 11: 57, 2016 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-27089966

RESUMEN

BACKGROUND: The aim of this study was to quantify the variability in spinal radiosurgery (SRS) planning practices between five international institutions, all member of the Elekta Spine Radiosurgery Research Consortium. METHODS: Four institutions provided one representative patient case each consisting of the medical history, CT and MR imaging. A step-wise planning approach was used where, after each planning step a consensus was generated that formed the basis for the next planning step. This allowed independent analysis of all planning steps of CT-MR image registration, GTV definition, CTV definition, PTV definition and SRS treatment planning. In addition, each institution generated one additional SRS plan for each case based on intra-institutional image registration and contouring, independent of consensus results. RESULTS: Averaged over the four cases, image registration variability ranged between translational 1.1 mm and 2.4 mm and rotational 1.1° and 2.0° in all three directions. GTV delineation variability was 1.5 mm in axial and 1.6 mm in longitudinal direction averaged for the four cases. CTV delineation variability was 0.8 mm in axial and 1.2 mm in longitudinal direction. CTV-to-PTV margins ranged between 0 mm and 2 mm according to institutional protocol. Delineation variability was 1 mm in axial directions for the spinal cord. Average PTV coverage for a single fraction18 Gy prescription was 87 ± 5 %; Dmin to the PTV was 7.5 ± 1.8 Gy averaged over all cases and institutions. Average Dmax to the PRV_SC (spinal cord + 1 mm) was 10.5 ± 1.6 Gy and the average Paddick conformity index was 0.69 ± 0.06. CONCLUSIONS: Results of this study reflect the variability in current practice of spine radiosurgery in large and highly experienced academic centers. Despite close methodical agreement in the daily workflow, clinically significant variability in all steps of the treatment planning process was demonstrated. This may translate into differences in patient clinical outcome and highlights the need for consensus and established delineation and planning criteria.


Asunto(s)
Radiocirugia/métodos , Neoplasias de la Columna Vertebral/radioterapia , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Cooperación Internacional , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Imagen Multimodal , Órganos en Riesgo , Radiometría/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Reproducibilidad de los Resultados , Médula Espinal/efectos de la radiación , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
5.
Pract Radiat Oncol ; 5(2): 106-12, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25413416

RESUMEN

PURPOSE: The clinical challenge of radiation therapy (RT) for painful bone metastases requires clinicians to consider both treatment efficacy and patient prognosis when selecting a radiation therapy regimen. The traditional RT workflow requires several weeks for common palliative RT schedules of 30 Gy in 10 fractions or 20 Gy in 5 fractions. At our institution, we have created a new RT workflow termed "STAT RAD" that allows clinicians to perform computed tomographic (CT) simulation, planning, and highly conformal single fraction treatment delivery within 2 hours. In this study, we evaluate the safety and feasibility of the STAT RAD workflow. METHODS AND MATERIALS: A failure mode and effects analysis (FMEA) was performed on the STAT RAD workflow, including development of a process map, identification of potential failure modes, description of the cause and effect, temporal occurrence, and team member involvement in each failure mode, and examination of existing safety controls. A risk probability number (RPN) was calculated for each failure mode. As necessary, workflow adjustments were then made to safeguard failure modes of significant RPN values. After workflow alterations, RPN numbers were again recomputed. RESULTS: A total of 72 potential failure modes were identified in the pre-FMEA STAT RAD workflow, of which 22 met the RPN threshold for clinical significance. Workflow adjustments included the addition of a team member checklist, changing simulation from megavoltage CT to kilovoltage CT, alteration of patient-specific quality assurance testing, and allocating increased time for critical workflow steps. After these modifications, only 1 failure mode maintained RPN significance; patient motion after alignment or during treatment. CONCLUSIONS: Performing the FMEA for the STAT RAD workflow before clinical implementation has significantly strengthened the safety and feasibility of STAT RAD. The FMEA proved a valuable evaluation tool, identifying potential problem areas so that we could create a safer workflow.


Asunto(s)
Neoplasias Óseas/radioterapia , Neoplasias Óseas/secundario , Planificación de la Radioterapia Asistida por Computador/métodos , Simulación por Computador , Humanos , Seguridad del Paciente , Medición de Riesgo , Gestión de Riesgos , Tomografía Computarizada por Rayos X/métodos , Flujo de Trabajo
6.
J Neurosurg ; 116(6): 1304-10, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22424563

RESUMEN

OBJECT: Gamma Knife surgery (GKS) has become a significant component of neurosurgical treatment for recurrent secretory and nonsecretory pituitary adenomas. Although the long-term risks of visual dysfunction following microsurgical resection of pituitary adenomas has been well studied, the comparable risk following radiosurgery is not well defined. This study evaluates the long-term risks of ophthalmological dysfunction following GKS for recurrent pituitary adenomas. METHODS: An analysis of 217 patients with recurrent secretory (n = 131) and nonsecretory (n = 86) pituitary adenomas was performed to determine the incidence of and risk factors for subsequent development of visual dysfunction. Patients underwent ophthalmological evaluation as part of post-GKS follow-up to assess for new or worsened cranial nerve II, III, IV, or VI palsies. The median follow-up duration was 32 months. The median maximal dose was 50 Gy, and the median peripheral dose was 23 Gy. A univariate analysis was performed to assess for risk factors of visual dysfunction post-GKS. RESULTS: Nine patients (4%) developed new visual dysfunctions, and these occurred within 6 hours to 34 months following radiosurgery. None of these 9 patients had tumor growth on post-GKS neuroimaging studies. Three of these patients had permanent deficits whereas in 6 the deficits resolved. Five of the 9 patients had prior GKS or radiotherapy, which resulted in a significant increase in the incidence of cranial nerve dysfunction (p = 0.0008). An increased number of isocenters (7.1 vs 5.0, p = 0.048) was statistically related to the development of visual dysfunction. Maximal dose, margin dose, optic apparatus dose, tumor volume, cavernous sinus involvement, and suprasellar extension were not significantly related to visual dysfunction (p >0.05). CONCLUSIONS: Neurological and ophthalmological assessment in addition to routine neuroimaging and endocrinological follow-up are important to perform following GKS. Patients with a history of radiosurgery or radiation therapy are at higher risk of cranial nerve deficits. Also, a reduction in the number of isocenters delivered, along with volume treated, particularly in the patients with secretory tumors, appears to be the most reasonable strategy to minimize the risk to the visual system when treating recurrent pituitary adenomas with stereotactic radiosurgery.


Asunto(s)
Adenoma/cirugía , Enfermedades de los Nervios Craneales/diagnóstico , Enfermedades de los Nervios Craneales/epidemiología , Traumatismos del Nervio Craneal/diagnóstico , Traumatismos del Nervio Craneal/epidemiología , Recurrencia Local de Neoplasia/cirugía , Neoplasias Hipofisarias/cirugía , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/epidemiología , Radiocirugia/efectos adversos , Trastornos de la Visión/diagnóstico , Trastornos de la Visión/epidemiología , Estudios Transversales , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Reoperación , Estudios Retrospectivos , Factores de Riesgo
7.
World Neurosurg ; 75(5-6): 665-72, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21704934

RESUMEN

OBJECTIVE: To present our initial experience with the Elekta eXtend System, a relocatable frame system for multiple-fraction or serial multiple-session radiosurgery. METHODS: The eXtend System comprises a carbon-fiber frame system known as the eXtend Frame, a vacuum cushion, and a vacuum pump/vacuum surveillance system. The eXtend Frame comprises a carbon-fiber frame, a mouthpiece with dental impression, and a configurable front-piece that accepts the mouthpiece and rigidly attaches to the carbon-fiber frame. Treatment preparation involves creating a dental impression, fitting the patient to the frame system at the Gamma Knife, acquiring a stereotactic computed tomography (CT) scan, and co-registering a volumetric magnetic resonance image. Measurements taken at the time of CT imaging using high-precision electronic probes locate the patient's head within the eXtend frame. These measurements are compared to measurements taken at the time of treatment to ensure the patient is in proper treatment position. Vacuum surveillance interlocks pause the treatment if the patient moves within the eXtend frame. RESULTS: As of June 2010, we have treated four patients at the University of Virginia with the eXtend System. In all cases treated to date, we were able to complete all fractions of the prescribed treatments. In addition, while in some cases repositioning before a given fraction required several attempts, we were able to achieve a radial repositioning error of less than 1 mm without taking new reference measurements and repeating patient setup and imaging. CONCLUSIONS: Gamma Knife radiosurgery (GKRS) has traditionally been a single-fraction treatment modality. The eXtend System expands the range of indications for GKRS to those that may benefit from multi-fraction or serial multi-session techniques. The relocatable eXtend frame can provide non-invasive head fixation while maintaining a high accuracy, high dose, and the steep gradients associated with GKRS.


Asunto(s)
Radiocirugia/instrumentación , Calibración , Técnica de Impresión Dental , Diseño de Equipo , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Planificación de Atención al Paciente , Postura , Garantía de la Calidad de Atención de Salud , Radiocirugia/métodos , Programas Informáticos , Técnicas Estereotáxicas , Tomografía Computarizada por Rayos X
8.
J Neurosurg ; 114(3): 763-8, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20225924

RESUMEN

OBJECT: Stereotactic radiosurgery has been shown to afford a reasonable chance of local tumor control. However, new brain metastasis can arise following successful local tumor control from radiosurgery. This study evaluates the timing, number, and risk factors for development of subsequent new brain metastasis in a group of patients treated with stereotactic radiosurgery alone. METHODS: One hundred seventeen patients with histologically confirmed metastatic cancer underwent Gamma Knife surgery (GKS) to treat all brain metastases demonstrable on MR imaging. Patients were followed clinically and radiologically at approximately 3-month intervals for a median of 14.4 months (range 0.37-51.8 months). Follow-up MR images were evaluated for evidence of new brain metastasis formation. Statistical analyses were performed to determine the timing, number, and risk factors for development of new brain metastases. RESULTS: The median time to development of a new brain metastasis was 8.8 months. Patients with 3 or more metastases at the time of initial radiosurgery or those with cancer histologies other than non-small cell lung carcinoma were found to be at increased risk for early formation of new brain metastasis (p < 0.05). The mean number of new metastases per patient was 1.6 (range 0-11). Those with a higher Karnofsky Performance Scale score at the time of initial GKS were significantly more likely to develop a greater number of brain metastases by the last follow-up evaluation. CONCLUSIONS: The timing and number of new brain metastases developing in patients treated with GKS alone is not inconsequential. Those with 3 or more metastases at the time of radiosurgery and those with cancer histology other than non-small cell lung carcinoma were at greater risk of early formation of new brain metastasis. Frequent follow-up evaluations, such as at 3-month intervals, appears appropriate in this patient population, particularly in high-risk patients. When detected early, salvage treatments including repeat radiosurgery can be used to treat new brain metastasis.


Asunto(s)
Neoplasias Encefálicas/epidemiología , Neoplasias Encefálicas/secundario , Procedimientos Neuroquirúrgicos , Radiocirugia , Neoplasias Encefálicas/cirugía , Carcinoma de Pulmón de Células no Pequeñas/patología , Carcinoma de Células Renales/patología , Femenino , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Estado de Ejecución de Karnofsky , Neoplasias Renales/patología , Neoplasias Pulmonares/patología , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Análisis de Regresión , Factores de Riesgo , Análisis de Supervivencia , Factores de Tiempo
9.
Cancer ; 117(2): 414-20, 2011 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-20830691

RESUMEN

BACKGROUND: Circadian cell-cycle progression causes fluctuating radiosensitivity in many tissues, which could affect clinical outcomes. The purpose of this study was to determine whether outcomes of single-session gamma knife radiosurgery (GKRS) for metastatic nonsmall cell lung cancer (NSCLC) differ based on treatment time. METHODS: Fifty-eight patients received GKRS between 10:00 am and 12:30 pm and 39 patients received GKRS between 12:30 pm and 3:00 pm. The mean peripheral dose was 18.6 Gy. The mean tumor size was 7.3 cm³. Magnetic resonance imaging was used to score local control at 3 months. Cause of death (COD) was categorized as central nervous system (CNS)-related or systemic. RESULTS: Demographic and disease characteristics of the 2 groups were similar. Local control at 3 months was achieved in 97% (35/36) of patients who underwent GKRS early in the day versus 67% (8/12) of patients who underwent GKRS later in the day (chi-square, P = .014). Early GKRS was associated with better survival (median 9.5 months) than late GKRS (median 5 months) (Kaplan-Meier log-rank test, P = .025). Factors contributing to better survival in a Cox regression model included early treatment time (P = .004) and recursive partition analysis class (P < .001). Cause of death in the early treatment group was CNS-related in 6% (3/47) of patients versus 24% (8/34) of patients in the late treatment group (chi-square test, P = .026). CONCLUSIONS: GKRS for metastatic NSCLC had better local control, better survival, and a lower rate of CNS-related cause of death when given earlier in the day versus later in the day. These retrospective data should encourage future study in brain radiosurgery and non-CNS stereotactic body radiotherapy series.


Asunto(s)
Neoplasias Encefálicas/secundario , Neoplasias Encefálicas/cirugía , Carcinoma de Pulmón de Células no Pequeñas/patología , Neoplasias Pulmonares/patología , Radiocirugia/métodos , Neoplasias Encefálicas/mortalidad , Neoplasias Encefálicas/patología , Ritmo Circadiano , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
10.
J Neurosurg ; 113 Suppl: 144-8, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21121796

RESUMEN

OBJECT: Treatment planning for Gamma Knife surgery has traditionally been a forward planning (FP)-only approach with results that depend significantly on the experience of the user. Leksell GammaPlan version 10.0, currently in beta testing, introduces a new inverse planning (IP) engine that may allow more reproducible results across dosimetrists and individual institutions. In this study the authors compared the FP and IP approaches to Gamma Knife surgery. METHODS: Forty-three patients with pituitary adenomas were evaluated after dose planning was performed using FP and IP treatment approaches. Treatment plans were compared for target coverage, target selectivity, Paddick gradient index, number of isocenters, optic pathways dose, and treatment time. Differences between the forward and inverse treatment plans were evaluated in a statistical fashion. RESULTS: The IP software generated a dose plan within approximately 10 minutes. The FP approach delivered the prescribed isodose to a larger treatment volume than the IP system (p < 0.001). The mean (± SD) FP and IP coverage indices were 0.85 ± 0.23 and 0.85 ± 0.13, respectively (no significant difference). The mean FP and IP gradient indices were 2.78 ± 0.20 and 3.08 ± 0.37, respectively (p < 0.001). The number of isocenters did not appreciably differ between approaches. The maximum doses directed to the optic apparatus for the FP and IP methods were 8.67 ± 1.97 Gy and 12.33 ± 5.86 Gy, respectively (p < 0.001). CONCLUSIONS: The Leksell GammaPlan IP system was easy to operate and provided a reasonable, first approximation dose plan. Particularly in cases in which there are eloquent structures at risk, experience and user-based optimization will be required to achieve an acceptable Gamma Knife dose plan.


Asunto(s)
Neoplasias Hipofisarias/cirugía , Radiocirugia/instrumentación , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/instrumentación , Algoritmos , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Programas Informáticos
11.
J Neurosurg Pediatr ; 6(5): 426-34, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21039165

RESUMEN

OBJECT: The aim of this study was to evaluate the long-term imaging and clinical outcomes of intracranial arteriovenous malformations (AVMs) in children treated with Gamma Knife surgery (GKS). METHODS: Between 1989 and 2007, 200 patients with AVMs who were 18 years of age or younger were treated at the University of Virginia Health System. Excluding 14 patients who had not reached 2-year follow-up, 186 patients comprised this study. Hemorrhage was the most common presenting symptom leading to the diagnosis of AVMs (71.5%). The mean nidus volume was 3.2 cm(3) at the time of GKS, and a mean prescription dose of 21.9 Gy was used. RESULTS: After initial GKS, 49.5% of patients achieved total angiographic obliteration. Forty-one patients whose AVM nidi remained patent underwent additional GKS. The obliteration rate increased to 58.6% after a second or multiple GKS. Subtotal obliteration was achieved in 9 patients (4.8%). Forty-nine patients (26.3%) still had a patent residual nidus. In 19 patients (10.2%), obliteration was confirmed on MR imaging only. Ten patients had 17 hemorrhages during the follow-up period. The hemorrhage rate was 5.4% within 2 years after GKS and 0.8% between 2 and 5 years. Six patients developed neurological deficits along with the radiation-induced changes. Two patients developed asymptomatic meningiomas 10 and 12 years after GKS. After a mean clinical follow-up of 98 months, less than 4% of patients had difficulty attending school or developing a career. CONCLUSIONS: Gamma Knife surgery offers a reasonable chance of obliteration of an AVM in pediatric patients. The incidence of symptomatic radiation-induced changes is relatively low; however, long-term clinical and imaging follow-up is required to identify delayed cyst formation and secondary tumors.


Asunto(s)
Malformaciones Arteriovenosas Intracraneales/cirugía , Radiocirugia/métodos , Adolescente , Daño Encefálico Crónico/etiología , Angiografía Cerebral , Hemorragia Cerebral/etiología , Niño , Preescolar , Femenino , Estudios de Seguimiento , Humanos , Malformaciones Arteriovenosas Intracraneales/diagnóstico , Malformaciones Arteriovenosas Intracraneales/diagnóstico por imagen , Discapacidades para el Aprendizaje/etiología , Masculino , Neoplasias Meníngeas/etiología , Meningioma/etiología , Complicaciones Posoperatorias/etiología , Reoperación
12.
Med Phys ; 37(8): 4078-101, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20879569

RESUMEN

Task Group 101 of the AAPM has prepared this report for medical physicists, clinicians, and therapists in order to outline the best practice guidelines for the external-beam radiation therapy technique referred to as stereotactic body radiation therapy (SBRT). The task group report includes a review of the literature to identify reported clinical findings and expected outcomes for this treatment modality. Information is provided for establishing a SBRT program, including protocols, equipment, resources, and QA procedures. Additionally, suggestions for developing consistent documentation for prescribing, reporting, and recording SBRT treatment delivery is provided.


Asunto(s)
Guías de Práctica Clínica como Asunto , Radiocirugia/normas , Estados Unidos
13.
Cancer ; 116(2): 514-9, 2010 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-19937955

RESUMEN

BACKGROUND: Patients with human papillomavirus (HPV)-positive oropharyngeal carcinoma (OC) have better prognosis than patients with HPV-negative OC. The objective of the current study was to assess how different practices across the United States treat patients with OC with respect to screening for HPV DNA or p16. METHODS: Five hundred forty-two randomly selected radiation oncologists were sent an 11-question survey by email regarding the use of HPV/p16 screening in OC. The questionnaire addressed demographics of the practice, intensity-modulated radiotherapy (IMRT) use, screening practices for HPV DNA or p16, which year this began, the use of HPV or p16 data to direct patient care, and future plans for its use if it had not already been instituted. RESULTS: One hundred ninety-two responses (39.6%) were received. Thirty-five percent of respondents (67 of 188) reported screening for HPV DNA routinely, whereas 4.8% of respondents (9 of 188) reported screening for p16. Of the physicians who did not use screening techniques, 37.2% (44 of 118 respondents) reported future plans to institute these screening techniques, 20% (9 of 45 respondents) stated plans to institute these techniques in the next 6 months, 55.5% (25 of 45 respondents) stated plans to institute these techniques within 6 months to 1 year, and 22.2% (10 of 45 respondents) stated plans to institute these techniques within 1 to 2 years. Academic physicians were more likely to use screening techniques (62.7%; P < .001) compared with private practitioners (31.4%). Only 12.4% of respondents reported using HPV or p16 data to direct care. CONCLUSIONS: Approximately 40.4% of radiation oncology practices that responded to a survey in the United States screened for HPV DNA or p16 in OC, whereas only 12.4% used it to further direct care. This number appears to be growing rapidly. Clinical trials to further elucidate how HPV or p16 status should direct care in OC are warranted.


Asunto(s)
Inhibidor p16 de la Quinasa Dependiente de Ciclina/análisis , ADN Viral/análisis , Neoplasias Orofaríngeas/virología , Papillomaviridae/aislamiento & purificación , Pautas de la Práctica en Medicina , Encuestas de Atención de la Salud , Humanos , Papillomaviridae/genética , Oncología por Radiación , Encuestas y Cuestionarios
14.
Med Phys ; 36(8): 3413-9, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19746774

RESUMEN

Cardiac-synchronized brain motion is well documented, but the accurate measurement of such motion on the pixel-by-pixel basis has been hampered by the lack of proper imaging technique. In this article, the authors present the implementation of an autotracking spiral cine displacement-encoded stimulation echo (DENSE) magnetic resonance imaging (MRI) technique for the measurement of pulsatile brain motion during the cardiac cycle. Displacement-encoded dynamic MR images of three healthy volunteers were acquired throughout the cardiac cycle using the spiral cine-DENSE pulse sequence gated to the R wave of an electrocardiogram. Pixelwise Lagrangian displacement maps were computed, and 2D displacement as a function of time was determined for selected regions of interests. Different intracranial structures exhibited characteristic motion amplitude, direction, and pattern throughout the cardiac cycle. Time-resolved displacement curves revealed the pathway of pulsatile motion from brain stem to peripheral brain lobes. These preliminary results demonstrated that the spiral cine-DENSE MRI technique can be used to measure cardiac-synchronized pulsatile brain motion on the pixel-by-pixel basis with high temporal/spatial resolution and sensitivity.


Asunto(s)
Encéfalo/fisiología , Corazón/fisiología , Imagen por Resonancia Cinemagnética/métodos , Movimiento , Adulto , Algoritmos , Estudios de Factibilidad , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Factores de Tiempo
15.
J Neurosurg ; 111(3): 423-30, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19722810

RESUMEN

OBJECT: Brain metastases from gastrointestinal cancers are rare. However, the incidence is increasing because patients with gastrointestinal carcinoma tend to live longer due to earlier diagnosis and more effective treatment of systemic disease. The purpose of this study was to evaluate the efficacy of Gamma Knife surgery (GKS) for the treatment of brain metastases from gastrointestinal cancers. METHODS: The authors performed a retrospective review of 40 patients (18 women and 22 men) who had undergone GKS to treat a total of 118 metastases from gastrointestinal cancers between January 1996 and December 2006. The mean patient age was 58.7 years, and the mean Karnofsky Performance Scale (KPS) score was 70. There were 7 patients with esophageal cancer, 25 with colon cancer, 5 with rectal cancer, 2 with pancreatic cancer, and 1 with gastric cancer. Nineteen patients were treated with whole-brain radiotherapy and/or local brain radiotherapy before GKS. Twenty-four patients had extracranial metastases, and 3 had an additional primary cancer. The mean metastatic brain tumor volume was 4.3 cm3, and the mean maximum tumor dose varied from 17.1 to 76.7 Gy (mean 41.8 Gy). RESULTS: Follow-up imaging studies were available in 25 patients with a total of 90 treated metastases. The results demonstrate a tumor control rate of 91%. The median survival time was 6.7 months, and the 6-month and 1-year survival rates were 55 and 25%, respectively. A univariate analysis revealed that the KPS score (or=80) was significant (p=0.018) for improved survival. CONCLUSIONS: Results in this series suggest that GKS can be an effective tool for the treatment of brain metastases from gastrointestinal cancer.


Asunto(s)
Neoplasias Encefálicas/secundario , Neoplasias Encefálicas/cirugía , Neoplasias Gastrointestinales/patología , Radiocirugia , Adulto , Anciano , Neoplasias Encefálicas/mortalidad , Neoplasias del Colon/patología , Neoplasias Esofágicas/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neoplasias Pancreáticas/patología , Neoplasias del Recto/patología , Estudios Retrospectivos , Neoplasias Gástricas/patología
16.
Med Phys ; 35(9): 4262-77, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18841876

RESUMEN

This article is a tribute to the pioneering medical physicists over the last 50 years who have participated in the research, development, and commercialization of stereotactic radiosurgery (SRS) and stereotactic radiotherapy utilizing a wide range of technology. The authors have described the evolution of SRS through the eyes of physicists from its beginnings with the Gamma Knife in 1951 to proton and charged particle therapy; modification of commercial linacs to accommodate high precision SRS setups; the multitude of accessories that have enabled fine tuning patients for relocalization, immobilization, and repositioning with submillimeter accuracy; and finally the emerging technology of SBRT. A major theme of the article is the expanding role of the medical physicist from that of advisor to the neurosurgeon to the current role as a primary driver of new technology that has already led to an adaptation of cranial SRS to other sites in the body, including, spine, liver, and lung. SRS continues to be at the forefront of the impetus to provide technological precision for radiation therapy and has demonstrated a host of downstream benefits in improving delivery strategies for conventional therapy as well. While this is not intended to be a comprehensive history, and the authors could not delineate every contribution by all of those working in the pursuit of SRS development, including physicians, engineers, radiobiologists, and the rest of the therapy and dosimetry staff in this important and dynamic radiation therapy modality, it is clear that physicists have had a substantial role in the development of SRS and theyincreasingly play a leading role in furthering SRS technology.


Asunto(s)
Física Sanitaria/tendencias , Radiocirugia/tendencias , Humanos
17.
FEMS Microbiol Lett ; 274(2): 342-7, 2007 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17645526

RESUMEN

It has been shown previously that the RecA protein of Deinococcus radiodurans plays a unique role in the repair of DNA damage in this highly DNA damage-resistant organism. Despite the high level of amino-acid identity, previous work has shown that Escherichia coli RecA does not complement D. radiodurans RecA mutants, further suggesting the uniqueness of D. radiodurans RecA. The work presented here shows that E. coli RecA does in fact provide partial complementation to a D. radiodurans RecA null mutant, suggesting that the RecA protein from D. radiodurans may not be as unique as believed previously.


Asunto(s)
Daño del ADN/fisiología , Reparación del ADN/genética , Deinococcus/genética , Genes Bacterianos/genética , Rec A Recombinasas/fisiología , Daño del ADN/genética , Reparación del ADN/fisiología , ADN Bacteriano , Escherichia coli/genética , Regulación Bacteriana de la Expresión Génica , Tolerancia a Radiación , Rec A Recombinasas/genética
18.
Appl Environ Microbiol ; 73(13): 4226-33, 2007 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-17483268

RESUMEN

A previous survey of Bacteroides isolates suggested that the ermB gene entered Bacteroides spp. recently. Previously, ermB had been found almost exclusively in gram-positive bacteria. In one Bacteroides strain, ermB was located on 100-kb conjugative transposon (CTn) CTnBST. To assess the possible origin of this CTn, we obtained the full DNA sequence of CTnBST and used this information to investigate its possible origins. Over one-half of CTnBST had high sequence identity to a putative CTn found in the genome of Bacteroides fragilis YCH46. This included the ends of the CTn and genes involved in integration, transfer, and excision. However, the region around the ermB gene contained genes that appeared to originate from gram-positive organisms. In particular, a 7-kb segment containing the ermB gene was 100% identical to an ermB region found in the genome of the gram-positive bacterium Arcanobacterium pyogenes. A screen of Bacteroides isolates whose DNA cross-hybridized with a CTnBST probe revealed that several isolates did not carry the 7-kb region, implying that the acquisition of this region may be more recent than the acquisition of the entire CTnBST element by Bacteroides spp. We have also identified other Bacteroides isolates that carry a slightly modified 7-kb region but have no other traces of CTnBST. Thus, it is possible that this 7-kb region could itself be part of a mobile element that has inserted in a Bacteroides CTn. Our results show that CTnBST is a hybrid element which has acquired a portion of its coding region from gram-positive bacteria but which may originally have come from Bacteroides spp. or some related species.


Asunto(s)
Bacteroides/genética , Elementos Transponibles de ADN/genética , Actinomycetaceae/genética , Bacteroides/efectos de los fármacos , Bacteroides/aislamiento & purificación , Composición de Base , Secuencia de Bases , Colon/microbiología , Conjugación Genética , Cartilla de ADN/genética , ADN Bacteriano/química , ADN Bacteriano/genética , Farmacorresistencia Microbiana/genética , Eritromicina/farmacología , Genes Bacterianos , Bacterias Grampositivas/genética , Humanos , Datos de Secuencia Molecular , Sistemas de Lectura Abierta , Especificidad de la Especie