Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
BMC Cancer ; 24(1): 482, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38627648

RESUMEN

BACKGROUND: Therapies for metastatic castration-resistant prostate cancer (mCRPC) include targeting the androgen receptor (AR) with androgen receptor inhibitors (ARIs) and prostate-specific membrane antigen (PSMA). Having the ability to detect AR, AR splice variant 7 (AR-V7), or PSMA in circulating tumor cells (CTCs) or circulating exosomal cell-free RNA (cfRNA) could be helpful to guide selection of the appropriate therapy for each individual patient. The Vortex Biosciences VTX-1 system is a label-free CTC isolation system that enables the detection of the expression of multiple genes in both CTCs and exosomal cfRNA from the same blood sample in patients with mCRPC. Detection of both AR-V7 and PSMA gene expression in both CTCs and cfRNA simultaneously has not yet been reported. METHODS: To characterize the combined VTX-1-AdnaDetect workflow, 22Rv1 cancer cells were spiked into blood from healthy donors and processed with the VTX-1 to mimic patient samples and assess performances (capture efficiency, purity, AR and AR-V7 expression). Then, we collected 19 blood samples from 16 patients with mCRPC and therapeutic resistance to androgen receptor inhibitors (ARIs). Plasma was separated and the plasma-depleted blood was processed further with the VTX-1 to collect CTCs. Both plasma exosomal cfRNA and CTCs were subsequently analyzed for AR, AR-V7, PSMA, and prostate-specific antigen (PSA) mRNA expression using the AdnaTest ProstateCancerPanel AR-V7 assay. RESULTS: AR-V7 expression could be detected in 22Rv1 cells spiked into blood from healthy volunteers as well as in CTCs and plasma-derived exosomal cfRNA from patients with mCRPC by processing blood with the VTX-1 CTC isolation system followed by the AdnaTest ProstateCancerPanel AR-V7 assay. 94.7% of patient blood samples (18/19) had detectable AR expression in either CTCs or exosomal cfRNA (16 in CTCs, 12 in cfRNA). 15.8% of the 19 patient blood samples (3/19) were found to have AR-V7-positive (AR-V7+) CTCs, one of which was also AR-V7+ in the exosomal cfRNA analysis. 42.1% of patient blood samples (8/19) were found to be PSMA positive (PSMA+): 26.3% (5/19) were PSMA+ in the CTC analysis and 31.6% (6/19) were PSMA+ in the exosomal cfRNA analysis. Of those 8 PSMA+ samples, 2 had detectable PSMA only in CTCs, and 3 had detectable PSMA only in exosomal cfRNA. CONCLUSION: VTX-1 enables isolation of CTCs and plasma exosomes from a single blood draw and can be used for detecting AR-V7 and PSMA mRNA in both CTCs and cfRNA in patients with mCRPC and resistance to ARIs. This technology facilitates combining RNA measurements in CTCs and exosomal cfRNA for future studies to develop potentially clinically relevant cancer biomarker detection in blood.


Asunto(s)
Ácidos Nucleicos Libres de Células , Exosomas , Células Neoplásicas Circulantes , Neoplasias de la Próstata Resistentes a la Castración , Humanos , Masculino , Antagonistas de Receptores Androgénicos/farmacología , Antagonistas de Receptores Androgénicos/uso terapéutico , Biomarcadores de Tumor/genética , Ácidos Nucleicos Libres de Células/genética , Ácidos Nucleicos Libres de Células/metabolismo , Exosomas/genética , Exosomas/metabolismo , Células Neoplásicas Circulantes/patología , Próstata/patología , Antígeno Prostático Específico , Neoplasias de la Próstata Resistentes a la Castración/tratamiento farmacológico , Isoformas de Proteínas/genética , Receptores Androgénicos/genética , Receptores Androgénicos/metabolismo , ARN Mensajero/genética
2.
Cancers (Basel) ; 12(5)2020 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-32380788

RESUMEN

BACKGROUND: Among emerging circulating biomarkers, miRNA has the potential to detect lung cancer and follow the course of the disease. However, miRNA analysis deserves further standardization before implementation into clinical trials or practice. Here, we performed international ring experiments to explore (pre)-analytical factors relevant to the outcome of miRNA blood tests in the context of the EU network CANCER-ID. METHODS: Cell-free (cfmiRNA) and extracellular vesicle-derived miRNA (EVmiRNA) were extracted using the miRNeasy Serum/Plasma Advanced, and the ExoRNeasy Maxi kit, respectively, in a plasma cohort of 27 NSCLC patients and 20 healthy individuals. Extracted miRNA was investigated using small RNA sequencing and hybridization platforms. Validation of the identified miRNA candidates was performed using quantitative PCR. RESULTS: We demonstrate the highest read counts in healthy individuals and NSCLC patients using QIAseq. Moreover, QIAseq showed 15.9% and 162.9% more cfmiRNA and EVmiRNA miRNA counts, respectively, in NSCLC patients compared to healthy control samples. However, a systematic comparison of selected miRNAs revealed little agreement between high-throughput platforms, thus some miRNAs are detected with one technology, but not with the other. Adding to this, 35% (9 of 26) of selected miRNAs in the cfmiRNA and 42% (11 of 26) in the EVmiRNA fraction were differentially expressed by at least one qPCR platform; about half of the miRNAs (54%) were concordant for both platforms. CONCLUSIONS: Changing of (pre)-analytical methods of miRNA analysis has a significant impact on blood test results and is therefore a major confounding factor. In addition, to confirm miRNA biomarker candidates screening studies should be followed by targeted validation using an independent platform or technology.

3.
Clin Chem ; 66(1): 149-160, 2020 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-31628139

RESUMEN

BACKGROUND: In cancer patients, circulating cell-free DNA (ccfDNA) can contain tumor-derived DNA (ctDNA), which enables noninvasive diagnosis, real-time monitoring, and treatment susceptibility testing. However, ctDNA fractions are highly variable, which challenges downstream applications. Therefore, established preanalytical work flows in combination with cost-efficient and reproducible reference materials for ccfDNA analyses are crucial for analytical validity and subsequently for clinical decision-making. METHODS: We describe the efforts of the Innovative Medicines Initiative consortium CANCER-ID (http://www.cancer-id.eu) for comparing different technologies for ccfDNA purification, quantification, and characterization in a multicenter setting. To this end, in-house generated mononucleosomal DNA (mnDNA) from lung cancer cell lines carrying known TP53 mutations was spiked in pools of plasma from healthy donors generated from 2 different blood collection tubes (BCTs). ccfDNA extraction was performed at 15 partner sites according to their respective routine practice. Downstream analysis of ccfDNA with respect to recovery, integrity, and mutation analysis was performed centralized at 4 different sites. RESULTS: We demonstrate suitability of mnDNA as a surrogate for ccfDNA as a process quality control from nucleic acid extraction to mutation detection. Although automated extraction protocols and quantitative PCR-based quantification methods yielded the most consistent and precise results, some kits preferentially recovered spiked mnDNA over endogenous ccfDNA. Mutated TP53 fragments derived from mnDNA were consistently detected using both next-generation sequencing-based deep sequencing and droplet digital PCR independently of BCT. CONCLUSIONS: This comprehensive multicenter comparison of ccfDNA preanalytical and analytical work flows is an important contribution to establishing evidence-based guidelines for clinically feasible (pre)analytical work flows.


Asunto(s)
Ácidos Nucleicos Libres de Células/metabolismo , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Recolección de Muestras de Sangre , Línea Celular Tumoral , Ácidos Nucleicos Libres de Células/química , Ácidos Nucleicos Libres de Células/normas , ADN Tumoral Circulante/sangre , Análisis Mutacional de ADN , Secuenciación de Nucleótidos de Alto Rendimiento/normas , Humanos , Neoplasias/genética , Neoplasias/patología , Nucleosomas/genética , Polimorfismo de Nucleótido Simple , Fase Preanalítica , Reacción en Cadena en Tiempo Real de la Polimerasa/normas , Estándares de Referencia , Proteína p53 Supresora de Tumor/genética
4.
Clin Chem ; 65(9): 1132-1140, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31235535

RESUMEN

BACKGROUND: In human body fluids, microRNA (miRNA) can be found as circulating cell-free miRNA (cfmiRNA), as well as secreted into extracellular vesicles (EVmiRNA). miRNAs are being intensively evaluated as minimally invasive liquid biopsy biomarkers in patients with cancer. The growing interest in developing clinical assays for circulating miRNA necessitates careful consideration of confounding effects of preanalytical and analytical parameters. METHODS: By using reverse transcription quantitative real-time PCR and next-generation sequencing (NGS), we compared extraction efficiencies of 5 different protocols for cfmiRNA and 2 protocols for EVmiRNA isolation in a multicentric manner. The efficiency of the different extraction methods was evaluated by measuring exogenously spiked cel-miR-39 and 6 targeted miRNAs in plasma from 20 healthy individuals. RESULTS: There were significant differences between the tested methods. Although column-based extraction methods were highly effective for the isolation of endogenous miRNA, phenol extraction combined with column-based miRNA purification and ultracentrifugation resulted in lower quality and quantity of isolated miRNA. Among all extraction methods, the ubiquitously expressed miR-16 was represented with high abundance when compared with other targeted miRNAs. In addition, the use of miR-16 as an endogenous control for normalization of quantification cycle values resulted in a decreased variability of column-based cfmiRNA extraction methods. Cluster analysis of normalized NGS counts clearly indicated a method-dependent bias. CONCLUSIONS: The choice of plasma miRNA extraction methods affects the selection of potential miRNA marker candidates and mechanistic interpretation of results, which should be done with caution, particularly across studies using different protocols.


Asunto(s)
MicroARN Circulante/sangre , MicroARN Circulante/aislamiento & purificación , Anciano , Animales , Biomarcadores de Tumor/sangre , Biomarcadores de Tumor/aislamiento & purificación , Caenorhabditis elegans/química , Fraccionamiento Químico/métodos , Vesículas Extracelulares/química , Femenino , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Humanos , Masculino , Persona de Mediana Edad , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos
5.
Curr Pathobiol Rep ; 6(4): 275-286, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30595972

RESUMEN

PURPOSE OF REVIEW: Liquid biopsy analyses based on circulating cell-free nucleic acids, circulating tumor cells or other diseased cells from organs, and exosomes or other microvesicles in blood offer new means for non-invasive diagnostic applications. The main goal of this review is to explain the importance of preserving whole blood specimens after blood draw for use as liquid biopsies, and to summarize preservation solutions that are currently available. RECENT FINDINGS: Despite the great potential of liquid biopsies for diagnostics and disease management, besides non-invasive prenatal testing (NIPT), only a few liquid biopsy applications are fully implemented for routine in vitro diagnostic testing. One major barrier is the lack of standardized pre-analytical workflows, including the collection of consistent quality blood specimens and the generation of good-quality plasma samples therefrom. Broader use of liquid biopsies in clinical routine applications therefore requires improved pre-analytical procedures to enable high-quality specimens to obtain unbiased analyte profiles (DNA, RNA, proteins, etc.) as they are in the patient's body. SUMMARY: A growing number of stabilizing reagents and dedicated blood collection tubes are available for the post-collection preservation of circulating cell-free DNA (ccfDNA) profiles in whole blood. In contrast, solutions for the preservation of circulating tumor cells (CTC) that enable both, enumeration and molecular analyses are rare. Solutions for extracellular vesicle (EV) populations, including exosomes, do not yet exist.

6.
PLoS One ; 10(8): e0136133, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26317354

RESUMEN

Exosomes and other extracellular vesicles (commonly referred to as EVs) have generated a lot of attention for their potential applications in both diagnostics and therapeutics. The contents of these vesicles are the subject of intense research, and the relatively recent discovery of RNA inside EVs has raised interest in the biological function of these RNAs as well as their potential as biomarkers for cancer and other diseases. Traditional ultracentrifugation-based protocols to isolate EVs are labor-intensive and subject to significant variability. Various attempts to develop methods with robust, reproducible performance have not yet been completely successful. Here, we report the development and characterization of a spin column-based method for the isolation of total RNA from EVs in serum and plasma. This method isolates highly pure RNA of equal or higher quantity compared to ultracentrifugation, with high specificity for vesicular over non-vesicular RNA. The spin columns have a capacity to handle up to 4 mL sample volume, enabling detection of low-abundance transcripts in serum and plasma. We conclude that the method is an improvement over traditional methods in providing a faster, more standardized way to achieve reliable high quality RNA preparations from EVs in biofluids such as serum and plasma. The first kit utilizing this new method has recently been made available by Qiagen as "exoRNeasy Serum/Plasma Maxi Kit".


Asunto(s)
Micropartículas Derivadas de Células/química , Exosomas/química , ARN/aislamiento & purificación , Micropartículas Derivadas de Células/metabolismo , Exosomas/metabolismo , Femenino , Humanos , Masculino , ARN/sangre , Juego de Reactivos para Diagnóstico , Ultracentrifugación/métodos
7.
Curr Protoc Mol Biol ; Chapter 4: Unit 4.19, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23821444

RESUMEN

Ribosomal RNA (rRNA) is the most highly abundant component of RNA, comprising the majority (>80% to 90%) of the molecules present in a total RNA sample. Depletion of this rRNA fraction is desirable prior to performing an RNA-seq reaction, so that sequencing capacity can be focused on more informative parts of the transcriptome. This unit describes an rRNA depletion method based on selective hybridization of oligonucleotides to rRNA, recognition with a hybrid-specific antibody, and removal of the antibody-hybrid complex on magnetic beads.


Asunto(s)
Secuenciación de Nucleótidos de Alto Rendimiento/métodos , ARN Ribosómico/aislamiento & purificación , ARN/genética , ARN/aislamiento & purificación , Manejo de Especímenes/métodos , Anticuerpos/metabolismo , Hibridación de Ácido Nucleico/métodos , Oligonucleótidos/genética , Oligonucleótidos/metabolismo , ARN Ribosómico/genética , ARN Ribosómico/metabolismo
8.
PLoS One ; 2(12): e1261, 2007 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-18060057

RESUMEN

The large archives of formalin-fixed paraffin-embedded (FFPE) tissue specimens that exist are a highly valuable source of sample material for molecular biological analysis, including gene expression profiling. However, current data on adverse effects of standard pathological practice on the usefulness of biomolecular analytes obtained from such archived specimens is largely anecdotal. Here, we present a systematic examination of the most relevant parameters for integrity and useability of RNA obtained from FFPE samples, including storage time and conditions, fixation time, and specimen size. The results are particularly relevant for any application relying on cDNA synthesis as an initial step of the procedure, such as RT-PCR, and microarray analysis.


Asunto(s)
ARN/normas , Animales , Formaldehído , Adhesión en Parafina , ARN/aislamiento & purificación , Ratas , Ratas Wistar , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Manejo de Especímenes , Fijación del Tejido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...