Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Cardiovasc Intervent Radiol ; 26(3): 283-9, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-14562980

RESUMEN

PURPOSE: To investigate pressure and maximum rate of rise of systolic pressure (peak dP/dt) in completely excluded aneurysms and endoleaks to determine the hemodynamic impact of endoleaks. METHODS: In mongrel dogs (n = 36) experimental aneurysms were created by insertion of a patch (portion of rectus abdominis muscle sheath) into the infrarenal aorta. In group I (n = 18), all aortic branches of the aneurysm were ligated and all aneurysms were completely excluded by stent grafts. Group II (n = 18) consisted of aneurysms with patent aortic side branches that represented sources of endoleaks. One week (n = 12), six weeks (n = 12), and six months (n = 12) after stent grafting, hemodynamic measurements were obtained in thrombosed aneurysms and proved endoleaks. Systemic blood pressure and intraaneurysmal pressure were simultaneously measured and the respective peak dP/dt were computed. RESULTS: At the six-month follow-up, the systolic-pressure ratio (intraaneurysmatic pressure: systemic pressure) was significantly increased in endoleaks compared to non-perfused areas (0.879 +/- 0.042 versus 0.438 +/- 0.176, p < 0.01, group II) or completely excluded aneurysms (0.385 +/- 0.221, group I). Peak dP/dt ratio (intraaneurysmal peak dP/dt: systemic peak dP/dt) was 0.922 +/- 0.154 in endoleaks, compared to 0.084 +/- 0.080 in non-perfused areas (group II, p < 0.01), and was 0.146 +/- 0.121 in completely excluded aneurysms (group I). The diastolic-pressure ratio was also increased in endoleaks compared to non-perfused areas (0.929 +/- 0.088 versus 0.655 +/- 0.231, p < 0.01, group II) or completely excluded aneurysms (0.641 +/- 0.278, group I). In excluded aneurysms, pressure exposure declined as the length of the follow-up period increased. CONCLUSION: Type II endoleaks transmit pulsatile pressure of near systemic level and indicate insufficient treatment result. In contrast, complete endovascular exclusion of aneurysms results in significantly reduced pressure exposure.


Asunto(s)
Aneurisma de la Aorta Abdominal/etiología , Aneurisma de la Aorta Abdominal/fisiopatología , Presión Sanguínea/fisiología , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/fisiopatología , Flujo Pulsátil/fisiología , Stents , Animales , Aorta Abdominal/diagnóstico por imagen , Aorta Abdominal/fisiopatología , Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico , Implantación de Prótesis Vascular , Circulación Colateral/fisiología , Diástole/fisiología , Modelos Animales de Enfermedad , Perros , Estudios de Seguimiento , Modelos Cardiovasculares , Complicaciones Posoperatorias/diagnóstico , Sístole/fisiología , Factores de Tiempo , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...