Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Anal Chem ; 95(37): 13932-13940, 2023 09 19.
Artículo en Inglés | MEDLINE | ID: mdl-37676066

RESUMEN

In environmental research, it is critical to understand how toxins impact invertebrate eggs and egg banks, which, due to their tiny size, are very challenging to study by conventional nuclear magnetic resonance (NMR) spectroscopy. Microcoil technology has been extensively utilized to enhance the mass-sensitivity of NMR. In a previous study, 5-axis computer numerical control (CNC) micromilling (shown to be a viable alternative to traditional microcoil production methods) was used to create a prototype copper slotted-tube resonator (STR). Despite the excellent limit of detection (LOD) of the resonator, the quality of the line shape was very poor due to the magnetic susceptibility of the copper resonator itself. This is best solved using magnetic susceptibility-matched materials. In this study, approaches are investigated that improve the susceptibility while retaining the versatility of coil milling. One method involves machining STRs from various copper/aluminum alloys, while the other involves machining ones from an aluminum 2011 alloy and electroplating them with copper. In all cases, combining copper and aluminum to produce resonators resulted in improved line shape and SNR compared to pure copper resonators due to their reduced magnetic susceptibility. However, the copper-plated aluminum resonators showed optimal performance from the devices tested. The enhanced LOD of these STRs allowed for the first 1H-13C heteronuclear multiple quantum coherence (HMQC) of a single intact 13C-labeled Daphnia magna egg (∼4 µg total biomass). This is a key step toward future screening programs that aim to elucidate the toxic processes in aquatic eggs.


Asunto(s)
Aluminio , Cobre , Animales , Aleaciones , Biomasa , Daphnia
2.
Anal Chem ; 95(14): 5858-5866, 2023 04 11.
Artículo en Inglés | MEDLINE | ID: mdl-36996326

RESUMEN

Toxicity testing is currently undergoing a paradigm shift from examining apical end points such as death, to monitoring sub-lethal toxicity in vivo. In vivo nuclear magnetic resonance (NMR) spectroscopy is a key platform in this endeavor. A proof-of-principle study is presented which directly interfaces NMR with digital microfluidics (DMF). DMF is a "lab on a chip" method allowing for the movement, mixing, splitting, and dispensing of µL-sized droplets. The goal is for DMF to supply oxygenated water to keep the organisms alive while NMR detects metabolomic changes. Here, both vertical and horizontal NMR coil configurations are compared. While a horizontal configuration is ideal for DMF, NMR performance was found to be sub-par and instead, a vertical-optimized single-sided stripline showed most promise. In this configuration, three organisms were monitored in vivo using 1H-13C 2D NMR. Without support from DMF droplet exchange, the organisms quickly showed signs of anoxic stress; however, with droplet exchange, this was completely suppressed. The results demonstrate that DMF can be used to maintain living organisms and holds potential for automated exposures in future. However, due to numerous limitations of vertically orientated DMF, along with space limitations in standard bore NMR spectrometers, we recommend future development be performed using a horizontal (MRI style) magnet which would eliminate practically all the drawbacks identified here.


Asunto(s)
Imagen por Resonancia Magnética , Microfluídica , Espectroscopía de Resonancia Magnética/métodos , Metabolómica/métodos , Dispositivos Laboratorio en un Chip
3.
Anal Chem ; 94(24): 8756-8765, 2022 06 21.
Artículo en Inglés | MEDLINE | ID: mdl-35675504

RESUMEN

Comprehensive multiphase-nuclear magnetic resonance (CMP-NMR) is a non-invasive approach designed to observe all phases (solutions, gels, and solids) in intact samples using a single NMR probe. Studies of dead and living organisms are important to understand processes ranging from biological growth to environmental stress. Historically, such studies have utilized 1H-based phase editing for the detection of soluble/swollen components and 1H-detected 2D NMR for metabolite assignments/screening. However, living organisms require slow spinning rates (∼500 Hz) to increase survivability, but at such low speeds, complications from water sidebands and spectral overlap from the modest chemical shift window (∼0-10 ppm) make 1H NMR challenging. Here, a novel 13C-optimized E-Free magic angle spinning CMP probe is applied to study all phases in ex vivo and in vivo samples. This probe consists of a two-coil design, with an inner single-tuned 13C coil providing a 113% increase in 13C sensitivity relative to a traditional multichannel single-CMP coil design. For organisms with a large biomass (∼0.1 g) like the Ganges River sprat (ex vivo), 13C-detected full spectral editing and 13C-detected heteronuclear correlation (HETCOR) can be performed at natural abundance. Unfortunately, for a single living shrimp (∼2 mg), 13C enrichment was still required, but 13C-detected HETCOR shows superior data relative to heteronuclear single-quantum coherence at low spinning speeds (due to complications from water sidebands in the latter). The probe is equipped with automatic-tuning-matching and is compatible with automated gradient shimming─a key step toward conducting multiphase screening of dead and living organisms under automation in the near future.


Asunto(s)
Carbono , Agua , Isótopos de Carbono , Espectroscopía de Resonancia Magnética
4.
Magn Reson Chem ; 60(3): 386-397, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34647646

RESUMEN

Microcoils provide a cost-effective approach to improve detection limits for mass-limited samples. Single-sided planar microcoils are advantageous in comparison to volume coils, in that the sample can simply be placed on top. However, the considerable drawback is that the RF field that is produced by the coil decreases with distance from the coil surface, which potentially limits more complex multi-pulse NMR pulse sequences. Unfortunately, 1 H NMR alone is not very informative for intact biological samples due to line broadening caused by magnetic susceptibility distortions, and 1 H-13 C 2D NMR correlations are required to provide the additional spectral dispersion for metabolic assignments in vivo or in situ. To our knowledge, double-tuned single-sided microcoils have not been applied for the 2D 1 H-13 C analysis of intact 13 C enriched biological samples. Questions include the following: Can 1 H-13 C 2D NMR be performed on single-sided planar microcoils? If so, do they still hold sensitivity advantages over conventional 5 mm NMR technology for mass limited samples? Here, 2D 1 H-13 C HSQC, HMQC, and HETCOR variants were compared and then applied to 13 C enriched broccoli seeds and Daphnia magna (water fleas). Compared to 5 mm NMR probes, the microcoils showed a sixfold improvement in mass sensitivity (albeit only for a small localized region) and allowed for the identification of metabolites in a single intact D. magna for the first time. Single-sided planar microcoils show practical benefit for 1 H-13 C NMR of intact biological samples, if localized information within ~0.7 mm of the 1 mm I.D. planar microcoil surface is of specific interest.


Asunto(s)
Daphnia , Imagen por Resonancia Magnética , Animales , Espectroscopía de Resonancia Magnética/métodos , Resonancia Magnética Nuclear Biomolecular
5.
Anal Chem ; 93(29): 10326-10333, 2021 07 27.
Artículo en Inglés | MEDLINE | ID: mdl-34259008

RESUMEN

Comprehensive multiphase (CMP) NMR, first described in 2012, combines all of the hardware components necessary to analyze all phases (solid, gel, and solution) in samples in their natural state. In combination with spectral editing experiments, it can fully differentiate phases and study the transfer of chemical species across and between phases, providing unprecedented molecular-level information in unaltered natural systems. However, many natural samples, such as swollen soils, plants, and small organisms, contain water, salts, and ionic compounds, making them electrically lossy and susceptible to RF heating, especially when using high-strength RF fields required to select the solid domains. While dedicated reduced-heating probes have been developed for solid-state NMR, to date, all CMP-NMR probes have been based on solenoid designs, which can lead to problematic sample heating. Here, a new prototype CMP probe was developed, incorporating a loop gap resonator (LGR) for decoupling. Temperature increases are monitored in salt solutions analogous to those in small aquatic organisms and then tested in vivo on Hyalella azteca (freshwater shrimp). In the standard CMP probe (solenoid), 80% of organisms died within 4 h under high-power decoupling, while in the LGR design, all organisms survived the entire test period of 12 h. The LGR design reduced heating by a factor of ∼3, which allowed 100 kHz decoupling to be applied to salty samples with generally ≤10 °C sample heating. In addition to expanding the potential for in vivo research, the ability to apply uncompromised high-power decoupling could be beneficial for multiphase samples containing true crystalline solids that require the strongest possible decoupling fields for optimal detection.


Asunto(s)
Calefacción , Calor , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Ondas de Radio
6.
Analyst ; 146(14): 4461-4472, 2021 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-34136891

RESUMEN

Comprehensive multiphase NMR combines the ability to study and differentiate all phases (solids, gels, and liquids) using a single NMR probe. The general goal of CMP-NMR is to study intact environmental and biological samples to better understand conformation, organization, association, and transfer between and across phases/interfaces that may be lost with conventional sample preparation such as drying or solubilization. To date, all CMP-NMR studies have used 4 mm probes and rotors. Here, a larger 7 mm probehead is introduced which provides ∼3 times the volume and ∼2.4 times the signal over a 4 mm version. This offers two main advantages: (1) the additional biomass reduces experiment time, making 13C detection at natural abundance more feasible; (2) it allows the analysis of larger samples that cannot fit within a 4 mm rotor. Chicken heart tissue and Hyalella azteca (freshwater shrimp) are used to demonstrate that phase-based spectral editing works with 7 mm rotors and that the additional biomass from the larger volumes allows detection with 13C at natural abundance. Additionally, a whole pomegranate seed berry (aril) and an intact softgel capsule of hydroxyzine hydrochloride are used to demonstrate the analysis of samples too large to fit inside a conventional 4 mm CMP probe. The 7 mm version introduced here extends the range of applications and sample types that can be studied and is recommended when 4 mm CMP probes cannot provide adequate signal-to-noise (S/N), or intact samples are simply too big for 4 mm rotors.


Asunto(s)
Imagen por Resonancia Magnética , Biomasa , Espectroscopía de Resonancia Magnética
7.
Anal Chem ; 92(23): 15454-15462, 2020 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-33170641

RESUMEN

The superior mass sensitivity of microcoil technology in nuclear magnetic resonance (NMR) spectroscopy provides potential for the analysis of extremely small-mass-limited samples such as eggs, cells, and tiny organisms. For optimal performance and efficiency, the size of the microcoil should be tailored to the size of the mass-limited sample of interest, which can be costly as mass-limited samples come in many shapes and sizes. Therefore, rapid and economic microcoil production methods are needed. One method with great potential is 5-axis computer numerical control (CNC) micromilling, commonly used in the jewelry industry. Most CNC milling machines are designed to process larger objects and commonly have a precision of >25 µm (making the machining of common spiral microcoils, for example, impossible). Here, a 5-axis MiRA6 CNC milling machine, specifically designed for the jewelry industry, with a 0.3 µm precision was used to produce working planar microcoils, microstrips, and novel microsensor designs, with some tested on the NMR in less than 24 h after the start of the design process. Sample wells could be built into the microsensor and could be machined at the same time as the sensors themselves, in some cases leaving a sheet of Teflon as thin as 10 µm between the sample and the sensor. This provides the freedom to produce a wide array of designs and demonstrates 5-axis CNC micromilling as a versatile tool for the rapid prototyping of NMR microsensors. This approach allowed the experimental optimization of a prototype microstrip for the analysis of two intact adult Daphnia magna organisms. In addition, a 3D volume slotted-tube resonator was produced that allowed for 2D 1H-13C NMR of D. magna neonates and exhibited 1H sensitivity (nLODω600 = 1.49 nmol s1/2) close to that of double strip lines, which themselves offer the best compromise between concentration and mass sensitivity published to date.


Asunto(s)
Costos y Análisis de Costo , Espectroscopía de Resonancia Magnética/economía , Espectroscopía de Resonancia Magnética/instrumentación , Microtecnología/instrumentación , Animales , Daphnia/química , Diseño de Equipo , Fenómenos Mecánicos , Factores de Tiempo
8.
Anal Chim Acta X ; 6: 100051, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33392494

RESUMEN

Nuclear Magnetic Resonance (NMR) spectroscopy is a non-invasive analytical technique which allows for the study of intact samples. Comprehensive Multiphase NMR (CMP-NMR) combines techniques and hardware from solution state and solid state NMR to allow for the holistic analysis of all phases (i.e. solutions, gels and solids) in unaltered samples. This study is the first to apply CMP-NMR to deceased, intact organisms and uses 13C enriched Daphnia magna (water fleas) as an example. D. magna are commonly used model organisms for environmental toxicology studies. As primary consumers, they are responsible for the transfer of nutrients across trophic levels, and a decline in their population can potentially impact the entire freshwater aquatic ecosystem. Though in vivo research is the ultimate tool to understand an organism's most biologically relevant state, studies are limited by conditions (i.e. oxygen requirements, limited experiment time and reduced spinning speed) required to keep the organisms alive, which can negatively impact the quality of the data collected. In comparison, ex vivo CMP-NMR is beneficial in that; organisms do not need oxygen (eliminating air holes in rotor caps and subsequent evaporation); samples can be spun faster, leading to improved spectral resolution; more biomass per sample can be analyzed; and experiments can be run for longer. In turn, higher quality ex vivo NMR, can provide more comprehensive NMR assignments, which in many cases could be transferred to better understand less resolved in vivo signals. This manuscript is divided into three sections: 1) multiphase spectral editing techniques, 2) detailed metabolic assignments of 2D NMR of 13C enriched D. magna and 3) multiphase biological changes over different life stages, ages and generations of D. magna. In summary, ex vivo CMP-NMR proves to be a very powerful approach to study whole organisms in a comprehensive manner and should provide very complementary information to in vivo based research.

9.
Angew Chem Int Ed Engl ; 58(43): 15372-15376, 2019 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-31449724

RESUMEN

Microcoil nuclear magnetic resonance (NMR) has been interfaced with digital microfluidics (DMF) and is applied to monitor organic reactions in organic solvents as a proof of concept. DMF permits droplets to be moved and mixed inside the NMR spectrometer to initiate reactions while using sub-microliter volumes of reagent, opening up the potential to follow the reactions of scarce or expensive reagents. By setting up the spectrometer shims on a reagent droplet, data acquisition can be started immediately upon droplet mixing and is only limited by the rate at which NMR data can be collected, allowing the monitoring of fast reactions. Here we report a cyclohexene carbonate hydrolysis in dimethylformamide and a Knoevenagel condensation in methanol/water. This is to our knowledge the first time rapid organic reactions in organic solvents have been monitored by high field DMF-NMR. The study represents a key first step towards larger DMF-NMR arrays that could in future serve as discovery platforms, where computer controlled DMF automates mixing/titration of chemical libraries and NMR is used to study the structures formed and kinetics in real time.

10.
Lab Chip ; 19(4): 641-653, 2019 02 12.
Artículo en Inglés | MEDLINE | ID: mdl-30648175

RESUMEN

In recent years microcoils and related structures have been developed to increase the mass sensitivity of nuclear magnetic resonance spectroscopy, allowing this extremely powerful analytical technique to be extended to small sample volumes (<5 µl). In general, microchannels have been used to deliver the samples of interest to these microcoils; however, these systems tend to have large dead volumes and require more complex fluidic connections. Here, we introduce a two-plate digital microfluidic (DMF) strategy to interface small-volume samples with NMR microcoils. In this system, a planar microcoil is surrounded by a copper plane that serves as the counter-electrode for the digital microfluidic device, allowing for precise control of droplet position and shape. This feature allows for the user-determination of the orientation of droplets relative to the main axes of the shim stack, permitting improved shimming and a more homogeneous magnetic field inside the droplet below the microcoil, which leads to improved spectral lineshape. This, along with high-fidelity droplet actuation, allows for rapid shimming strategies (developed over decades for vertically oriented NMR tubes) to be employed, permitting the determination of reaction-product diffusion coefficients as well as quantitative monitoring of reactive intermediates. We propose that this system paves the way for new and exciting applications for in situ analysis of small samples by NMR spectroscopy.

11.
MAGMA ; 24(3): 137-45, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21331647

RESUMEN

OBJECT: The aim of this study was to demonstrate the feasibility of MR microimaging on a conventional 9.4 T horizontal animal MRI system using commercial available microcoils in combination with only minor modifications to the system, thereby opening this field to a larger community. MATERIALS AND METHODS: Commercially available RF microcoils designed for high-resolution NMR spectrometers were used in combination with a custom-made probehead. For this purpose, changes within the transmit chain and modifications to the adjustment routines and image acquisition sequences were made, all without requiring expensive hardware. To investigate the extent to which routine operation and high-resolution imaging is possible, the quality of phantom images was analysed. Surface and solenoidal microcoils were characterized with regard to their sensitive volume and signal-to-noise ratio. In addition, the feasibility of using planar microcoils to achieve high-resolution images of living glioma cells labelled with MnCl(2) was investigated. RESULTS: The setup presented in this work allows routine acquisition of high-quality images with high SNR and isotropic resolutions up to 10 µm within an acceptable measurement time. CONCLUSION: This study demonstrates that MR microscopy can be applied at low cost on animal MR imaging systems, which are in widespread use. The successful imaging of living glioma cells indicates that the technique promises to be a useful tool in biomedical research.


Asunto(s)
Aumento de la Imagen/instrumentación , Imagen por Resonancia Magnética/instrumentación , Espectroscopía de Resonancia Magnética/instrumentación , Microscopía/instrumentación , Animales , Técnicas de Cultivo de Célula , Diseño de Equipo , Estudios de Factibilidad , Humanos , Espectroscopía de Resonancia Magnética/métodos , Fantasmas de Imagen
12.
Neuroimage ; 52(2): 556-61, 2010 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-20403443

RESUMEN

Magnetic resonance imaging techniques have literally revolutionized neuroimaging with an unprecedented ability to explore tissue structure and function. Over the last three decades, the sensitivity and array of imaging techniques available have improved providing ever finer structural information and more sensitive functional techniques. Among these methods, diffusion imaging techniques have facilitated the generation of fiber-tract maps of the brain enabling an examination of issues related to brain structure and neural connectivity. Despite the potential utility of the techniques described, validation has not yet been achieved on biological samples. Recently, using newly developed surface microcoils on small samples at high magnetic fields, we demonstrated the ability of MR microscopy to image individual neurons in mammalian brain tissue. In the present work, we combine MR microscopy with the highest resolution (15microm) fiber tracking yet reported and demonstrate the accuracy of the fiber tract maps with direct histological validation. Thus it becomes possible to delineate fiber structure in tissues at the cellular level. A semi-quantitative approach was used to estimate the cell overlap fraction (cOF) and fiber tract overlap fraction (tOF), with cOFs of 94%, 92% and 100%, and tOFs of 84%, 86% and 100%, in rat cervical, rat lumbar, and pig spinal cord tissue, respectively. These methods provide a way to directly validate fiber tracking techniques with histology so that contemporary tracking techniques may be compared and refined using the microstructural details of a biological template as a ground truth.


Asunto(s)
Imagen de Difusión Tensora/métodos , Microscopía/métodos , Neuronas/citología , Médula Espinal/citología , Animales , Vértebras Cervicales , Imagen de Difusión Tensora/instrumentación , Estudios de Factibilidad , Técnicas Histológicas , Procesamiento de Imagen Asistido por Computador , Técnicas In Vitro , Vértebras Lumbares , Microscopía/instrumentación , Vías Nerviosas/citología , Ratas , Porcinos
13.
Neuroimage ; 46(4): 1037-40, 2009 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-19286461

RESUMEN

Magnetic resonance imaging (MRI) is now a leading diagnostic technique. As technology has improved, so has the spatial resolution achievable. In 1986 MR microscopy (MRM) was demonstrated with resolutions in the tens of micrometers, and is now an established subset of MRI with broad utility in biological and non-biological applications. To date, only large cells from plants or aquatic animals have been imaged with MRM limiting its applicability. Using newly developed microsurface coils and an improved slice preparation technique for correlative histology, we report here for the first time direct visualization of single neurons in the mammalian central nervous system (CNS) using native MR signal at a resolution of 4-8 microm. Thus MRM has matured into a viable complementary cellular imaging technique in mammalian tissues.


Asunto(s)
Sistema Nervioso Central/citología , Imagenología Tridimensional/métodos , Microscopía/métodos , Neuronas/citología , Médula Espinal/citología , Animales , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Ratas , Ratas Sprague-Dawley
14.
MAGMA ; 22(3): 181-6, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19184152

RESUMEN

INTRODUCTION: Hair care for humans is a major world industry with specialised tools, chemicals and techniques. Studying the effect of hair care products has become a considerable field of research, and besides mechanical and optical testing numerous advanced analytical techniques have been employed in this area. In the present work, another means of studying the properties of hair is added by demonstrating the feasibility of magnetic resonance imaging (MRI) of the human hair. MATERIALS AND METHODS: Established dedicated nuclear magnetic resonance microscopy hardware (solenoidal radiofrequency microcoils and planar field gradients) and methods (constant time imaging) were adapted to the specific needs of hair MRI. RESULTS: Images were produced at a spatial resolution high enough to resolve the inner structure of the hair, showing contrast between cortex and medulla. Quantitative evaluation of a scan series with different echo times provided a T*(2) value of 2.6 ms for the cortex and a water content of about 90% for hairs saturated with water. CONCLUSION: The demonstration of the feasibility of hair MRI potentially adds a new tool to the large variety of analytical methods used nowadays in the development of hair care products.


Asunto(s)
Cabello/anatomía & histología , Humanos , Imagenología Tridimensional/instrumentación , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética , Microscopía/instrumentación , Microscopía/métodos
15.
Childs Nerv Syst ; 25(2): 161-4, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19057906

RESUMEN

BACKGROUND: Inadvertent adjustments and malfunctions of programmable valves have been reported in cases in which patients have encountered powerful electromagnetic fields such as those involved in magnetic resonance imaging, but the potential effects of magnetic toys on programmable valves are not well known. MATERIALS AND METHODS: The magnetic properties of nine toy magnets were examined. To calculate the effect of a single magnet over a distance, the magnetic flux density was directly measured using a calibrated Hall probe at seven different positions between 0 and 120 mm from the magnet. Strata II small (Medtronic Inc.), Codman Hakim (Codman & Shurtleff), and Polaris (Sophysa) programmable valves were then tested to determine the effects of the toy magnets on each valve type. RESULTS: The maximal flux density of different magnetic toys differed between 17 and 540 mT, inversely proportional to the distance between toy and measurement instrument. Alterations to Strata and Codman valve settings could be effected with all the magnetic toys. The distances that still led to an alteration of the valve settings differed from 10 to 50 mm (Strata), compared with 5 to 30 mm (Codman). Valve settings of Polaris could not be altered by any toy at any distance due to its architecture with two magnets adjusted in opposite directions. CONCLUSION: This is the first report describing changes in the pressure setting of some adjustable valves caused by magnetic toys in close contact. Parents, surgeons, neurologists, pediatric oncologists, and paramedics should be informed about the potential dangers of magnetic toys to prevent unwanted changes to pressure settings.


Asunto(s)
Campos Electromagnéticos/efectos adversos , Magnetismo/instrumentación , Juego e Implementos de Juego , Falla de Prótesis , Derivación Ventriculoperitoneal/instrumentación , Preescolar , Humanos , Magnetismo/estadística & datos numéricos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...