Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
RSC Adv ; 8(11): 6183-6191, 2018 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-35539593

RESUMEN

The performance of the high-field MegaOrbitrap Fourier transform mass spectrometer (FT-MS) with electrospray ionization (ESI) was evaluated to perform petroleum sample characterization via classical petroleomics approaches. Pertinent parameters that underpin the main figures of merit, that is, signal to noise ratios, dynamic range, spectral error, scan speed, mass accuracy and mass resolving power = R p, and provide subsidies to develop these analyzers were tested. Comparisons are made with data obtained using the most common petroleomics instrument, which is a Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS), that has been used in the last decade in our laboratory for crude oil analysis providing R p of 340 000 at m/z 400 with transients of 3 s duration, and has been extensively demonstrated to fulfill all major requirements for precise petroleomics investigations. The high-field compact MegaOrbitrap mass analyzer, when operated at an R p = 840 000 at m/z 400 (R p > 1 000 000 at m/z 200) with a detection time of 3 s, was found to be well suited for adequate characterization of crude oil. Accurate class classification and mass accuracy below 1 ppm was obtained leading to proper, comprehensive petroleomics characterization.

2.
Analyst ; 137(11): 2537-40, 2012 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-22349120

RESUMEN

An exceptionally easy to assemble source for ambient mass spectrometry is described. Based on Venturi easy ambient sonic-spray ionization (V-EASI), the source was further simplified by the use of a can of compressed air which simultaneously provides solution or solvent Venturi self-pumping and continuous, stable and abundant low-noise ion signal via voltage-free sonic-spraying. Further simplification was also attained by the use of inexpensive and readily commercially available parts: a surgical 2-way catheter, an aerosol can of compressed air, a 30 cm long fused-silica capillary and a hypodermic needle. This "Spartan" V-EASI source seems to offer one of the easiest and cheapest ways to make ions for ambient desorption/ionization mass spectrometry analysis of both liquid and solid samples.

3.
J Org Chem ; 76(24): 10140-7, 2011 Dec 16.
Artículo en Inglés | MEDLINE | ID: mdl-22029265

RESUMEN

An acetate anion bearing an imidazolium cation as its charge tag was reacted with M(OAc)(2) complexes (where M = Ni, Cu, and Pd; in situ reaction) to form members of a new class of charge-tagged metal complexes. The formation of these unprecedented precatalysts with potential for cross-coupling reactions was confirmed by electrospray ionization (and tandem) mass spectrometry. The catalytic performance of the palladium complex was tested in Heck and Suzuki cross-coupling reactions, often with superior activity and yields as compared with Pd(OAc)(2).

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...